Strata DK I&M 5/995-1 DK424 Installation DK424 Installation5 This chapter explains how to install the Strata DK424 system. It includes information on site requirements and provides installation instructions for various cabinet configurations. It also explains how to install ground wiring, AC power cabling, reserve power (Battery Backup) cabling, and Printed Circuit Board (PCB) cabling. Inspection When the system is received, examine all packages carefully and note any visible damage. If any damage is...
Page 152
DK424 Installation Site Requirements 5-2Strata DK I&M 5/99 Site Requirements Input Power The DK424 requires an input power source of 115VAC ± 10 VAC, 50/60 Hz, 17.5 amps. The system requires one or two AC outlets that must be dedicated to system use, fused, and grounded. See “Power Supply Installation” on Page 5-8 for complete AC power cabling, ground wiring and battery installation instructions.) CAUTION!To avoid accidental power turn-off, it is recommended that an ON/OFF wall switch not be used...
Page 153
DK424 Installation Site Requirements Strata DK I&M 5/995-3 DK424 Installation 24 24 78 6 14.5 23.6 11.75 13.5 Wall Floor Front View Top View 23.6 Cabinets9.75 36 Minimum Clearance Requirements (Wall Mounting) 24 24 75 3 Wall Floor Wall Wall Front View Top View 23.6 Cabinets 36 23.6 Minimum Clearance Requirements (Floor Mounting) 3 Floor Mount Stands (RFMF) 2 Brackets (RWBF) 1451 Expansion Cabinet Expansion Cabinet Expansion Cabinet Expansion Cabinet Expansion Cabinet Expansion CabinetBase Cabinet...
Page 154
DK424 Installation Site Requirements 5-4Strata DK I&M 5/99 Electrical/Environmental Requirements and Characteristics See Table 5-1 for the DK424 electrical/environmental requirements and characteristics. Table 5-1 Summary of Electrical/Environmental Characteristics DK424 Primary Power Input AC AC amps for seven-cabinet system AC frequency Watts per cabinet (continuous) Watts for six cabinet system (continuous)115VAC ± 10VAC 20 amp circuit 50/60 Hz 180 845 DK424 Maximum Peak AC Input Current 1...
Page 155
DK424 Installation Site Requirements Strata DK I&M 5/995-5 DK424 Installation Cable Lengths The Base and optional Expansion Cabinets must be placed within the allowed maximum distance of each other as designated by Ta b l e 5 - 2. Table 5-2 Station Loop Requirements DeviceInterface PCB CircuitsNo. of Wire Pairs (use 24 AWG twisted pair)Max Loop Resistance (including device) Maximum Distance from Cabinet to Device Digital telephones 1 1. Two-pair wiring or optional telephone power supply is...
Page 156
DK424 Installation Site Requirements 5-6Strata DK I&M 5/99 Network Requirements The system network requirements are provided in Table 5-3. Table 5-3 DK424 Network Requirements PCB/InterfaceFacility Interface CodeNetwork JackRinger EquivalenceUniversal Service Order Code PESU/RSTU2/RDSU1 (Off-premises Station) 1. Only PESU circuits 1 and 2, and RDSU circuits 1~4 provide Off-premises Station (OPS) capability. PESU must use OL13A or equivalent line conditioning for OPS connection. RDSU must use OL13A...
Page 157
DK424 Installation Cabinet Installation Considerations Strata DK I&M 5/995-7 DK424 Installation Cabinet Installation Considerations The Base (DKSUB424) and Expansion Cabinets (DKSUE424) can be wall or floor mounted. To make it easier to add cabinets (after the initial installation) when a customer needs to expand, install the Base Cabinet on top for wall-mount installations and on the bottom for floor-mount installations. The dimensions of the Base and Expansion Cabinets are: Height: Base Cabinet: 11...
Page 158
DK424 Installation Power Supply Installation 5-8Strata DK I&M 5/99 Power Supply Installation The Base and Expansion Cabinets are shipped from the factory without the power supply installed. The DK424 cabinets use the same power supply (RPSU280 and/or RPSU424) as the DK280. NoteRPSU280 and RPSU424 are fit, form, and functionally the same. They can be interchanged and mixed in DK280 and DK424 systems. ä To install power supplies in cabinets of new or installed systems 1. Remove the power supply from...
Page 159
DK424 Installation Power Supply Installation Strata DK I&M 5/995-9 DK424 Installation Right Front Right Side Cover Top Cover (Base Cabinet Only) Front Cover Remove this screw to remove the front cover Loosen three screws to remove front coverLoosen two screws to remove the side covers (right and left side covers) Loosen four screws to remove the top cover: Note: Do not remove the top cover if the Base Cabinet is the top cabinet. Shift cover left to remove front cover. Intercabinet Power Supply...
Page 160
DK424 Installation Power Supply Installation 5-10Strata DK I&M 5/99 1 2 3-24VPOWER +5V -5V AC INFGDC OUT + BATT- ON OFF FG Wire and Spade Lug (Functional Ground) DC Out Connector FG Wire Holder –24V Circuit Breakers Power Indicator LEDs (Green) FG Screw (3) R11 PCTU S11 S12 S13 S14 S15 S16 R11 S11RCTU S12 S13 S14 S15 S16 Bottom (2) Mounting Holes Top (2) Mounting Holes Jumper with wire must be installed only in base cabinet power supply using this connector Jumper with no wire must be installed in...