June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 61
5
5.1.14 Finisher related service call
[CB10] Transport motor abnormality
MJ-1025
Is the stack feed roller (upper) home position senso r (PI12) working properly?
NO 
 Replace the sensor.
YES 
Is the wiring between the finisher controller PC bo ard and feed motor (M1) correct?
NO 
 Correct the wiring.
YES 
Try turning the stack feed roller (upper) shaft by  hand. Does the stack feed roller (upper) 
move up/down normally?
NO...

Page 492

e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTINGJune 2004 © TOSHIBA TEC
5 - 62
[CB20] Delivery motor abnormality
MJ-1022
Rotate the delivery roller by hand. Does it rotate  smoothly?
NO 
 Fix the mechanism.
YES 
Is the wiring between the finisher controller PC bo ard and delivery motor (M1) correct?
NO 
 Correct the wiring.
YES 
Is the delivery motor clock sensor (S1) working prop erly?
NO 
 Replace the sensor.
YES 
1) Replace the delivery motor (M1). 
2) Replace the finisher controller PC board....

Page 493

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 63
5
[CB30] Tray lift motor abnormality
MJ-1025
[Procedure 1] 
Is the paper surface sensor (PI9) working properly?
NO 
 Replace the sensor.
YES 
Is the tray up/down mechanism working properly?
 NO 
 Fix the mechanism.
YES 
Is 24 VDC supplied from the finisher controller PC  board to the shift motor as soon as the 
tray is driven?
NO 
 Replace the finisher controller PC board.
YES 
Is the wiring between the finisher controller PC...

Page 494

e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTINGJune 2004 © TOSHIBA TEC
5 - 64
[Procedure 3] 
Does the tray go up?
l ll l l l ll l ll l

YES NO 
 Is 24 VDC supplied from the finisher controller PCB  to the shift motor as 
soon as the tray is driven?
 NO 
 Replace the finisher controller PC board.
YES 
Is there any problem with the tray up/down mechanism ?
 YES 
Fix the lift mechanism.
NO
Replace the shift motor.
Is the shift motor clock sensor (PI7) working prope rly?
YES 
Replace the finisher...

Page 495

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 65
5
[Procedure 2] 
Is the staple/fold motor clock sensor (PI14) workin g properly?
NO 
 Replace the sensor.
YES 
Does the staple/fold motor operate at the appropria te timing?
YES 
Replace the finisher controller PC board.
NO 
Is the stapler unit drive mechanism working properl y?
NO 
 Fix the mechanism.
YES 
Try replacing the staple/fold motor (M7). Is the pr oblem corrected?
YES 
End.
NO 
Replace the finisher controller PC...

Page 496

e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTINGJune 2004 © TOSHIBA TEC
5 - 66
[Procedure 4] 
Is the staple/fold motor clock sensor (PI14) workin g properly?
NO 
 Replace the sensor.
YES 
Does the staple/fold motor operate at the appropria te timing?
YES 
Replace the finisher controller PC board.
NO 
Is the saddle stitch unit drive mechanism working p roperly?
NO 
 Fix the mechanism.
YES 
Try replacing the staple/fold motor (M7). Is the pr oblem corrected?
YES 
End.
NO 
Replace the finisher controller...

Page 497

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 67
5
[CB80] Backup RAM data abnormality
MJ-1025
Is the problem solved by turning the power of the e quipment OFF and ON?
YES 
End.
NO 
1) Replace the finisher controller PC board. 
2) Replace the punch controller PC board.
[CC30] Stack processing motor abnormality/Paddle mot or abnormality
MJ-1022 (Stack processing motor abnormality)
[Procedure 1] 
Is the tension of the drive belt normal?
 NO 
 Loosen the adjustment screw to...

Page 498

e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTINGJune 2004 © TOSHIBA TEC
5 - 68
[Procedure 2] 
Does the bushing attached to the returning roller s haft smoothly move up and down?
l
 NO 
 Apply grease on the cut-out part of the front side  frame where the bush-
ing contacts.
YES 
Is the spring of the returning roller detached?
 YES 
Attach the spring.
NO 
Is the tension of the stack processing motor drive  belt normal?
NO 
 Loosen the adjustment screw to adjust its tension.
YES 
Is the returning roller...

Page 499

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 69
5
[CC50] Horizontal registration motor abnormality MJ-1025
Is the horizontal registration home position sensor  (PI2P) working properly?
NO 
 Replace the sensor.
YES 
Is the wiring between the finisher controller PC bo ard and the horizontal registration home 
position sensor (PI2P) correct?
NO 
 Correct the wiring.
YES 
Is there any problem with the horizontal registrati on mechanism?
YES 
Fix the mechanism.
NO 
Replace the...

Page 500

e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTINGJune 2004 © TOSHIBA TEC
5 - 70
[CC80] Front jogging plate motor abnormality/Alignme nt motor (front) abnormality
MJ-1022 (Front jogging plate motor abnormality)
Is the front jogging plate home position sensor (S6 ) working properly?
NO 
 Replace the sensor.
YES 
Is the wiring between the finisher controller PC bo ard and front jogging motor (M3) correct?
NO 
 Correct the wiring.
YES 
Has the rack run over the stopper of the roll?
 YES 
Fix it.
NO 
1)...