5. SYSTEM MODE EO18-33012A 5.7 SENSOR ADJUSTMENT 5-52 NOTES: 1. Perform a sensor threshold setting after changing the media to a different type. 2. An error related to the print position may be caused by the improperly set sensor threshold. In this case please perform a threshold setting in this mode. In case further adjustment is required, refer to Section 5.5 Printer Parameter Fine Adjustment to make the threshold fine adjustment. 3. When pressing the [FEED] and [RESTART] keys at the same time in the Sensor Adjustment menu, the display returns to “SENSOR ADJ.”. 4. The sensor status is checked every 200 msec. Therefore, the display may change according to the status. While pressing the [FEED] and [PAUSE] keys at the same time, turn on the printer. Hold both keys until the “DIAG. Vx.x” Message appears. Press the [FEED] key 4 times. The printer is at the start of the Sensor Adjustment menu. 5.7.1 Sensor Status Display When “SENSOR ADJ.” appears, press the [PAUSE] key to display the following. Pressing the [PAUSE] key again shows the following display: Press the [PAUSE] key to show the current black mark sensor status. !,$* 9[[ !6(1625 $- !6(1625 $- >6@°& Heat Sink Temperature Sensor Status 25°C, 80°C, 90°C, 99°C !6(1625 $- >+@°& >$@°& Print Head Temperature Thermistor Status 0 to 86 °C Environmental Temperature Thermistor Status 0 to 86 °C
5. SYSTEM MODE EO18-33012A 5.7 SENSOR ADJUSTMENT 5-53 5.7.2 Black Mark Sensor Adjustment Follow the Black mark sensor adjustment procedure below. (1) Load a tag stock in the B-SX series printer so that the Black Mark Sensor detects a print area (no black mark). (2) Press and hold the [RESTART] or [FEED] key for more than 3 seconds. (3) Remove the tag stock from the printer. (4) Press the [PAUSE] key to show the current Feed Gap Sensor status. 5.7.3 Feed Gap Sensor Adjustment Follow the Feed Gap Sensor adjustment procedure below. (1) Place the backing paper (labels are removed) in the B- SX series printer so that the Feed gap Sensor detects it. (2) Press and hold the [RESTART] or [FEED] key for more than 3 seconds. (3) Remove the backing paper from the printer. (4) Press the [PAUSE] key to show the current status of the Black Mark Sensor and the Feed Gap Sensor with no paper. !6(1625 $- >5()/(&7@ 9 W hen the adjustment is completed, “*” appears. !6(1625 $- >5()/(&7@ 9 The status detected by the Black Mark Sensor 0.0V to 5.0V !6(1625 $- >75$16@ 9 Status detected by the Feed Gap Sensor 0.0V to 5.0V !6(1625 $- >75$16@ 9 W hen the adjustment is completed, “*” appears.
5. SYSTEM MODE EO18-33012A 5.7 SENSOR ADJUSTMENT 5-54 5.7.4 Black Mark Sensor and Feed Gap Sensor Adjustment (No Paper) Follow the Black Mark Sensor (no paper)/Feed Gap Sensor (no paper) adjustment procedure below. (1) Remove any paper from the detecting area of the Black Mark Sensor and the Feed Gap Sensor. (2) Press and hold the [RESTART] or [FEED] key for more than 3 seconds. (3) Press the [PAUSE] key to show the current Ribbon End Sensor status. 5.7.5 Ribbon End Sensor Adjustment Follow the Ribbon End Sensor adjustment procedure below. (1) Place the ribbon in the B-SX series printer so that the Ribbon End Sensor detects it. (2) Press and hold the [RESTART] or [FEED] key for more than 3 seconds. (3) Press the [PAUSE] key to return to “SENSOR ADJ.” display. !6(1625 $- >3(@5979 W hen the adjustment is completed, “*” appears. !6(1625 $- >5,%%21@ 9 Status detected by the Ribbon End Sensor !6(1625 $- >5,%%21@ 9 W hen the adjustment is completed, “*” appears. !6(1625 $- >3(@5979 Status detected by the Black Mark Sensor (No paper) Status detected by the Feed Gap Sensor (No paper)
5. SYSTEM MODE EO18-33012A 5.8 RAM CLEAR 5-55 5.8 RAM CLEAR „Outline of RAM Clear In the RAM Clear mode, clearing the Maintenance Counter and initializing the Parameters are possible. After replacing the print head, ribbon motor, or platen, perform a maintenance clear. The RAM Clear menu contains the following: While pressing the [FEED] and [PAUSE] keys at the same time, turn on the printer. Hold both keys until the “DIAG. Vx.x” Message appears. Press the [FEED] key 5 times. The printer is at the start of the RAM Clear menu. 5.8.1 RAM Clear Menu Selection When “RAM CLEAR” appears, press the [PAUSE] key. Select the RAM Clear menu among “No RAM Clear”, “Maintenance Counter Clear”, or “Parameter Clear”. NOTES: 1. To exit the RAM clear menu selection, press the [FEED] and [RESTART] keys at the same. The display returns to “RAM CLEAR”. 2. After RAM clear, the following items are still stored: Label distance covered, Sensor adjustment value, IP address, Language for the LCD message, data in the flash memory, and data in the ATA card. !,$* 9[[ !5$0 &/($5 12 5$0 &/($5 0$,17(&17 &/($5[RESTART] [FEED] 3$5$0(7(5 &/($5RAM Clear is not performed. Clears the Maintenance Counter. Clears the Parameter. !5$0 &/($5 12 5$0 &/($5 !5$0 &/($5 0$,17(&17 &/($5 !5$0 &/($5 3$5$0(7(5 &/($5 !5$0 &/($5 No RAM Clear [PAUSE] [FEED] [FEED] [FEED] Maintenance Counter Clear Parameter Clear [RESTART] [RESTART] [RESTART]
5. SYSTEM MODE EO18-33012A 5.8 RAM CLEAR 5-56 5.8.2 No RAM Clear Press the [PAUSE] key. No RAM Clear operation is performed and the display returns to “RAM CLEAR”. Pressing the [PAUSE] key again causes the display to return to “NO RAM CLEAR”. 5.8.3 Maintenance Counter Clear Press the [PAUSE] key to perform the Maintenance Counter Clear. When the Maintenance Counter Clear is completed, the following message appears. Turn off the printer to exit this mode. „Initial values after clearing the maintenance counter (MANTE.CNT CLEAR) Item Initial Value Label distance covered 0 km Print distance 0 km Cut count 0 time Head up/down count 0 time Ribbon motor drive time 0 hour Solenoid drive time 0 hour RS-232C hardware error count 0 time System error count 0 time Momentary power failure count 0 time 5.8.4 Printer Parameter Clear Press the [PAUSE] key to show the destination code selection display. Select the destination code of the printer being used, and press the [PAUSE] key to perform a Printer Parameter Clear. When the Printer Parameter Clear is completed, the following message appears. Turn off the printer to exit this mode. 0$,17(&17 &/($5 &203/(7( 3$5$0(7(5 &/($5 &203/(7( 12 5$0 &/($5 [RESTART] [FEED] 43 7
5. SYSTEM MODE EO18-33012A 5.8 RAM CLEAR 5-57 „Initial values after clearing the parameters (PARAMETER CLEAR) Item Initial Value Feed length fine adjustment (PC), (KEY) 0 mm Cut (Strip) position fine adjustment (PC), (KEY) 0 mm Back feed length fine adjustment (PC), (KEY) 0 mm Print tone fine adjustment (Thermal transfer), (PC), (KEY) 0 Print tone fine adjustment (Thermal direct), (PC), (KEY) 0 Ribbon take-up motor driving voltage fine adjustment (PC), (KEY) 0 Ribbon feed motor driving voltage fine adjustment (PC), (KEY) 0 Threshold manual fine adjustment for the black mark sensor 1.0V Threshold manual fine adjustment for the feed gap sensor 1.4V X axis fine adjustment 0 mm Character code and zero font code PC-850, “0” (without slash) Control code AUTO Baud rate 9600 bps Data length QP/JA: 8 bits, QQ: 7 bits Stop bit 1 bit Parity QP: None, QQ/JA: EVEN Transmission control code QP/JA/: XON+READY AUTO QQ: READY/BUSY Forward wait OFF Feed key function FEED Kanji code type TYPE1 Euro code B0H Auto print head check OFF W eb printer function OFF Status response ON Label pitch 76.2 mm Effective print length 74.2 mm Effective print width 104.0 mm (B-SX4T), 128.0 mm (B-SX5T) Printing mode Thermal transfer Sensor type Feed gap sensor Print speed 6”/sec. (B-SX4T), 5”/sec. (B-SX5T) Issue mode Batch print PC save automatic calling ON (Save No. on the Main PCB (ID No.): 01) ACK/BUSY timing TYPE 1 LCD message language QQ/QP: English JA: Japanese Head up in cut mode/Rewinder selection Head up: OFF, Rewinder: OFF Ribbon saving module QQ/QP: OFF JA: ON Strip wait status OFF Input prime (Reset operation when INIT signal is ON.) ON: Available Ribbon near end detect OFF: No detection Expansion I/O mode TYPE1: Standard mode Centronics I/O mode SPP: Compatible mode Plug & Play OFF Print processing at the label end detection TYPE1: Printing is paused while the label is issued. Pre strip OFF: Unavailable Back feed speed STD: 3 inches/second Basic interpreter OFF: Unavailable Basic interpreter trace OFF: Unavailable DHCP function OFF: Unavailable NOTE: The initial values of Data length, Parity, Control code, LCD message language are different according to the destination code.
5. SYSTEM MODE EO18-33012A 5.9 IP ADDRESS SETTING 5-58 5.9 IP ADDRESS SETTING „Outline of the IP Address Setting In the IP Address Setting mode, you can set the IP Address, Gateway Address, Subnet Mask, DHCP, and DHCP ID which are necessary for a network communication. Since each setting value is different depending on your operating environment. The IP Address Setting menu contains the following: While pressing the [FEED] and [PAUSE] keys at the same time, turn on the printer. Hold both keys until the “DIAG. Vx.x” Message appears. Press the [FEED] key 6 times. The printer is at the start of the IP Address Setting menu. When “IP ADDRESS” appears, press the [PAUSE] key. Select the IP Address menu among “Printer IP Address”, “Socket Port”, “Gateway IP Address”, “Subnet Mask”, “DHCP”, or “DHCP Client ID”. !,$* 9[[ !,3 $5(66 Printer IP Address Setting Gateway IP Address Setting Subnet Mask Setting Socket Port Setting DHCP Setting [PAUSE] !,3 $5(66 35,17(5 ,3 $5(6 !,3 $5(66 *$7(:$< ,3 $5(6 !,3 $5(66 68%1(7 0$6. !,3 $5(66 62&.(7 3257 !,3 $5(66 +&3 !,3 $5(66 [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] DHCP ID Setting !,3 $5(66 +&3 &/,(17 , [RESTART] [FEED] [RESTART] [FEED] 35,17(5 ,3 $5(6 68%1(7 0$6. 62&.(7 3257 *$7(:$< ,3 $5(6 +&3 +&3 &/,(17 ,
5. SYSTEM MODE EO18-33012A 5.9 IP ADDRESS SETTING 5-59 (1) Printer IP Address, Gateway IP Address, and Subnet Mask Settings After selecting the menu set the IP address using the following procedure. Set the first 3 digit value with the [FEED] or [RESTART] key. Press the [PAUSE] key to move the cursor to the next 3 digit value. Set the next values in the same way. NOTES: 1. Pressing the [FEED] key one time causes a –1 change. Pressing the [RESTART] key one time causes a +1 change. 2. If holding the [FEED] or [RESTART] key for 0.5 seconds or longer in the parameter setting, the key is entered continuously. After the last 3 digit value is set, press the [PAUSE] key. The display will show “GATEWAY IP ADDRESS”. Set the values for the Gateway IP Address and Subnet Mask, respectively. (2) Socket Port Setting To set the socket port number, follow the procedure below. 3257 21 !,3 $5(66 3257 2)) 3257 21 3257 21 3257 21 62&.(7 3257 Select “PORT ON” or “PORT OFF” with the [RESTART] or [FEED] key. When “PORT ON” is selected, a port number is displayed. Pressing the [PAUSE] key allows the port number setting. [PAUSE] [PAUSE] [PAUSE] [PAUSE] Enter the 5th digit of the port number with the [RESTART] or [FEED] key. Pressing the [PAUSE] key allows the 4th digit setting. Repeat this procedure until the 1 st digit setting has been completed. Enter each digit of the port number with the [RESTART] or [FEED] key. [PAUSE] [RESTART] [FEED] [RESTART] [FEED] 3257 21 3257 21 3257 21 3257 21 3257 2))
5. SYSTEM MODE EO18-33012A 5.9 IP ADDRESS SETTING 5-60 (3) DHCP and DHCP ID Settings To set the DHCP and the DHCP ID, follow the procedure below. !,3 $5(66 +&3 21 !,3 $5(66 +&3 &/,(17 , 02( $6&,, +&3 &/,(17 , 02( +(; +&3 &/,(17 , )))))))))))))))) )))))))))))))))) !,3 $5(66 [PAUSE] [PAUSE] [PAUSE] [PAUSE] After the 16th byte value is set, the display returns to “IP ADDRESS”. !,3 $5(66 +&3 !,3 $5(66 +&3 2)) [PAUSE] Select ON or OFF with the [FEED] or [RESTART] key. Select ASCII or HEX with the [FEED] or [RESTART] key. Enter the numeric values for each byte (1st byte to 16th byte) with the [FEED] or [RESTART] key. [PAUSE] Repeat entering the values until the 16th byte value is entered. [RESTART] [FEED] +&3 21 +&3 2)) DHCP is available. DHCP is unavailable. DHCP setting Select “DHCP ON” or “DHCP OFF” with the [FEED] or [RESTART] key. [RESTART] [FEED] 02( +(; 02( $6&,, DHCP ID entering mode setting Select “ASCII” or “HEX” with the [FEED] or [RESTART] key. DHCP ID setting Set the ID from 1st byte to 16th byte. NOTE: HEX mode is used here. For ASCII mode, data of each byte will be showed in ASCII characters. FF FF FF FF FF FF FF FF (1st byte) (2nd byte) (3rd byte) (4th byte) (5th byte) (6th byte) (7th byte) (8th byte) FF FF FF FF FF FF FF FF (9th byte)(10th byte)(11th byte)(12th byte)(13th byte)(14th byte)(15th byte)(16th byte) )))))))))))))))) )))))))))))))))) [RESTART] )))))))))))))) )))))))))))))))) [PAUSE] [FEED] [FEED] ))))))))))))) )))))))))))))))) Example [RESTART] [FEED] FF FE FD A0 9F 9E 03 02 01
5. SYSTEM MODE EO18-33012A 5.10 BASIC SETTING 5-61 5.10 BASIC SETTING „Outline of Basic Setting Setting the BASIC specification and Trace specification to be enabled/disabled, and displaying the program file, data file, and area file are available in this mode. The Basic Setting menu contains the following. While pressing the [FEED] and [PAUSE] keys at the same time, turn on the printer. Hold both keys until the “DIAG. Vx.x” Message appears. Press the [FEED] key 8 times. The printer is at the start of the BASIC setting menu. When “BASIC” appears, press the [PAUSE] key. 5.10.1 Basic Specification Selection Mode Select whether the Basic specification is enable or not. !,$* 9[[ !%$6,& %$6,& (1$%/( [PAUSE] %$6,& 2)) %$6,& 21 ),/( 0$,17(1$1&( [PAUSE] [RESTART] [FEED] “BASIC ON” or “BASIC OFF” is selected each time the [RESTART] or [FEED] key is pressed. Basic specification selection is completed by pressing the [PAUSE] key. BASIC Specification Selection Mode BASIC File Browser BASIC Trace Selection Mode [PAUSE] !%$6,& %$6,& (1$%/( !%$6,& ),/( 0$,17(1$1&( !%$6,& %$6,& 75$&( !%$6,& [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED]