    							5. SYSTEM MODE  EO18-33012A 
     
    5.7 SENSOR ADJUSTMENT
     
    5-52 
    NOTES: 1.  Perform a sensor threshold setting after changing the media to a different type. 
     
    2.  An error related to the print position may be caused by the  improperly set sensor 
    threshold.  In this case please perform a threshold setting in this mode.  In case further 
    adjustment is required, refer to Section 5.5 Printer Parameter Fine Adjustment to make 
    the threshold fine adjustment.
     
     
    3.  When pressing the [FEED] and [RESTART] keys at the same time in the Sensor 
    Adjustment menu, the display returns to “SENSOR ADJ.”.
     
     
    4.  The sensor status is checked every 200 msec.  Therefore,  the display may change 
    according to the status.
     
     
     
    While pressing the [FEED]
     and [PAUSE]
     keys at the same time, turn on the printer.  Hold both keys 
    until the “DIAG. Vx.x” Message appears. 
     
     
    Press the [FEED]
     key 4 times.  The printer is at the start of the Sensor Adjustment menu. 
     
     
     
     
     5.7.1  Sensor Status Display 
     When “SENSOR ADJ.” appears, press the [PAUSE]
     key to display the following.
     
     
     
     
      
      
      
      
     
     Pressing the [PAUSE]
     key again shows the following display: 
     
     
     
     
     
     
     Press the [PAUSE] 
    key to show the current black mark sensor status. 
     
     
    !,$* 9[[
    !6(1625 $-
    !6(1625 $-
    >6@°&
    Heat Sink Temperature Sensor Status 
      25°C, 80°C, 90°C, 99°C 
    !6(1625 $-
    >+@°& >$@°&
    Print Head Temperature Thermistor Status 
      0 to 86 °C Environmental Temperature Thermistor Status 
      0 to 86 °C  
    						
    							5. SYSTEM MODE  EO18-33012A 
     
    5.7 SENSOR ADJUSTMENT
     
    5-53 
     5.7.2  Black Mark Sensor Adjustment 
     
     
     
     
     
     
     Follow the Black mark sensor adjustment procedure below. 
     (1)
     Load a tag stock in the B-SX series printer so that the Black Mark Sensor detects a print 
    area (no black mark). 
     (2)
     Press and hold the [RESTART]
     or [FEED]
     key for more than 3 seconds. 
     
     
     
     
     (3)
     Remove the tag stock from the printer.
     
     (4)
     Press the [PAUSE]
     key to show the current Feed Gap Sensor status.
     
     
     
     5.7.3  Feed Gap Sensor Adjustment 
     
     
     
      
      
     
     Follow the Feed Gap Sensor adjustment procedure below. 
     (1)
     Place the backing paper (labels are removed) in the B- SX series printer so that the Feed 
    gap Sensor detects it. 
     (2)
     Press and hold the [RESTART]
     or [FEED]
     key for more than 3 seconds. 
     
     
     
     
     (3)
     Remove the backing paper from the printer.
     
     (4)
     Press the [PAUSE]
     key to show the current status of the Black Mark Sensor and the Feed 
    Gap Sensor with no paper. 
     
     
    !6(1625 $-
    >5()/(&7@ 9
    W hen the adjustment is completed, “*” appears. 
    !6(1625 $-
    >5()/(&7@ 9
    The status detected by the Black Mark Sensor 
      0.0V to 5.0V 
    !6(1625 $-
    >75$16@ 9
    Status detected by the Feed Gap Sensor 
      0.0V to 5.0V 
    !6(1625 $-
    >75$16@ 9
    W hen the adjustment is completed, “*” appears.  
    						
    							5. SYSTEM MODE  EO18-33012A 
     
    5.7 SENSOR ADJUSTMENT
     
    5-54 
     5.7.4  Black Mark Sensor and Feed Gap Sensor Adjustment (No Paper) 
     
     
     
      
      
     
     
     Follow the Black Mark Sensor (no paper)/Feed Gap Sensor (no paper) adjustment procedure 
    below. 
     (1)
     Remove 
    any paper from the detecting area of the Black Mark Sensor and the Feed Gap 
    Sensor. 
     (2)
     Press and hold the [RESTART]
     or [FEED]
     key for more than 3 seconds. 
     
     
     
     
     
     (3)  Press the [PAUSE]
     key to show the current Ribbon End Sensor status. 
     
     
     5.7.5  Ribbon End Sensor Adjustment 
     
     
     
     
     
     Follow the Ribbon End Sensor adjustment procedure below. 
     (1)
     Place the ribbon in the B-SX series printer so that the Ribbon End Sensor detects it. 
     (2)
     Press and hold the [RESTART]
     or [FEED]
     key for more than 3 seconds. 
     
     
     
     
     
     (3)
     Press the [PAUSE]
     key to return to “SENSOR ADJ.” display. 
     
     
    !6(1625 $-
    >3(@5979
    W hen the adjustment is completed, “*” appears. 
    !6(1625 $-
    >5,%%21@ 9
    Status detected by the Ribbon End Sensor 
    !6(1625 $-
    >5,%%21@ 9
    W hen the adjustment is completed, “*” appears. 
    !6(1625 $-
    >3(@5979
    Status detected by the Black Mark Sensor (No paper)  Status detected by the Feed Gap Sensor (No paper)  
    						
    							5. SYSTEM MODE  EO18-33012A 
     
    5.8 RAM CLEAR
     
    5-55 
    5.8 RAM CLEAR 
    „Outline of RAM Clear 
    In the RAM Clear mode, clearing the Maintenance Counter and initializing the Parameters are 
    possible.  After replacing the print head, ribbon motor, or platen, perform a maintenance clear. 
     
    The RAM Clear
     menu contains the following: 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    While pressing the [FEED]
     and [PAUSE]
     keys at the same time, turn on the printer.  Hold both keys 
    until the “DIAG. Vx.x” Message appears. 
     
     
    Press the [FEED]
     key 5 times.  The printer is at the start of the RAM Clear menu. 
     
     
     
     
     
    5.8.1  RAM Clear Menu Selection 
     When “RAM CLEAR” appears, press the [PAUSE]
     key.
     
     Select the RAM Clear menu among “No RAM Clear”, “Maintenance Counter Clear”, or 
    “Parameter Clear”.  
     
     
     
     
     
     
     
    NOTES: 1.  To exit the RAM clear menu selection, press the [FEED] and [RESTART] keys at 
    the same.  The display returns to “RAM CLEAR”.
     
     
    2.  After RAM clear, the following items are still stored: Label distance covered, 
    Sensor adjustment value, IP address, Language for the LCD message, data in the 
    flash memory, and data in the ATA card. 
     
    !,$* 9[[
    !5$0 &/($5
    12 5$0 &/($5
    0$,17(&17 &/($5[RESTART] 
    [FEED] 
    3$5$0(7(5 &/($5RAM Clear is not performed.  
    Clears the Maintenance Counter. 
    Clears the Parameter. 
    !5$0 &/($5
    12 5$0 &/($5
    !5$0 &/($5
    0$,17(&17 &/($5
    !5$0 &/($5
    3$5$0(7(5 &/($5
    !5$0 &/($5
    No RAM Clear 
    [PAUSE] 
    [FEED] 
    [FEED] 
    [FEED] 
    Maintenance Counter Clear 
    Parameter Clear 
    [RESTART] 
    [RESTART] 
    [RESTART]  
    						
    							5. SYSTEM MODE EO18-33012A
     
     
    5.8 RAM CLEAR
     
    5-56 
      5.8.2  No RAM Clear 
     
     
     Press the [PAUSE]
     key.  No RAM Clear operation is performed and the display returns to 
    “RAM CLEAR”. 
     
      Pressing the [PAUSE]
     key again causes the display to return to “NO RAM CLEAR”. 
     
     
     5.8.3  Maintenance Counter Clear 
     
     
     Press the [PAUSE]
     key to perform the Maintenance Counter Clear. 
     When the Maintenance Counter Clear is completed, the following message appears. 
     
     
     Turn off the printer to exit this mode. 
    „Initial values after clearing the maintenance counter (MANTE.CNT CLEAR) 
    Item  Initial Value 
    Label distance covered 0 km 
    Print distance  0 km 
    Cut count  0 time 
    Head up/down count  0 time 
    Ribbon motor drive time  0 hour 
    Solenoid drive time  0 hour 
    RS-232C hardware error count  0 time 
    System error count  0 time 
    Momentary power failure count  0 time 
     
     
     
    5.8.4  Printer Parameter Clear 
     
     
     Press the [PAUSE] key to show the destination code selection display. 
     
     
     
     
     
     
     
     Select the destination code of the printer being used, and press the [PAUSE] key to perform a 
    Printer Parameter Clear. 
     When the Printer Parameter Clear is completed, the following message appears. 
     
     
     Turn off the printer to exit this mode.
     
    0$,17(&17 &/($5
    
    
    
     &203/(7( 
    
    
    3$5$0(7(5 &/($5
    
    
    
     &203/(7( 
    
    
    12 5$0 &/($5
    [RESTART] 
    [FEED] 
    
    
    
    43 7
    						
    							5. SYSTEM MODE EO18-33012A
     
     
    5.8 RAM CLEAR
     
    5-57 
    „Initial values after clearing the parameters (PARAMETER CLEAR) 
    Item  Initial Value 
    Feed length fine adjustment (PC), (KEY)  0 mm 
    Cut (Strip) position fine adjustment (PC), (KEY)  0 mm 
    Back feed length fine adjustment (PC), (KEY)  0 mm 
    Print tone fine adjustment (Thermal transfer), (PC), (KEY)  0 
    Print tone fine adjustment (Thermal direct), (PC), (KEY)  0 
    Ribbon take-up motor driving voltage fine adjustment  
    (PC), (KEY) 0 
    Ribbon feed motor driving voltage fine adjustment (PC), (KEY)  0 
    Threshold manual fine adjustment for the black mark sensor  1.0V 
    Threshold manual fine adjustment for the feed gap sensor  1.4V 
    X axis fine adjustment  0 mm 
    Character code and zero font code  PC-850,  “0” (without slash) 
    Control code AUTO 
    Baud rate  9600 bps 
    Data length  QP/JA: 8 bits,  QQ: 7 bits 
    Stop bit  1 bit 
    Parity  QP: None,  QQ/JA: EVEN 
    Transmission control code  QP/JA/: XON+READY AUTO 
    QQ: READY/BUSY 
    Forward wait   OFF 
    Feed key function  FEED 
    Kanji code type  TYPE1 
    Euro code  B0H 
    Auto print head check  OFF 
    W eb printer function  OFF 
    Status response  ON 
    Label pitch   76.2 mm 
    Effective print length  74.2 mm 
    Effective print width  104.0 mm (B-SX4T), 128.0 mm (B-SX5T) 
    Printing mode  Thermal transfer 
    Sensor type  Feed gap sensor 
    Print speed  6”/sec. (B-SX4T), 5”/sec. (B-SX5T) 
    Issue mode  Batch print 
    PC save automatic calling  ON 
    (Save No. on the Main PCB (ID No.): 
    01) 
    ACK/BUSY timing  TYPE 1 
    LCD message language  QQ/QP: English 
    JA: Japanese 
    Head up in cut mode/Rewinder selection  Head up: OFF, Rewinder: OFF 
    Ribbon saving module  QQ/QP: OFF  JA: ON 
    Strip wait status  OFF 
    Input prime (Reset operation when INIT signal is ON.)  ON: Available 
    Ribbon near end detect  OFF: No detection 
    Expansion I/O mode  TYPE1: Standard mode 
    Centronics I/O mode  SPP: Compatible mode 
    Plug & Play  OFF 
    Print processing at the label end detection  TYPE1: Printing is paused while the 
    label is issued. 
    Pre strip  OFF: Unavailable 
    Back feed speed  STD: 3 inches/second 
    Basic interpreter  OFF: Unavailable 
    Basic interpreter trace  OFF: Unavailable 
    DHCP function  OFF: Unavailable 
     
     
    NOTE: The initial values of Data length, Parity, Control code, LCD message language are 
    different according to the destination code.
      
    						
    							5. SYSTEM MODE EO18-33012A
     
     
    5.9 IP ADDRESS SETTING
     
    5-58 
    5.9  IP ADDRESS SETTING 
    „Outline of the IP Address Setting
     
    In the IP Address Setting mode, you can set the IP Address, Gateway Address, Subnet Mask, DHCP, 
    and DHCP ID which are necessary for a network communication.  Since each setting value is different 
    depending on your operating environment. 
     
    The
     IP Address Setting menu contains the following: 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    While pressing the 
    [FEED] and 
    [PAUSE] keys at the same time, turn on the printer.  Hold both keys 
    until the “DIAG. Vx.x” Message appears. 
     
     
    Press the 
    [FEED] key 6 times. 
    The printer is at the start of the IP Address Setting menu. 
     
     
    When “IP ADDRESS” appears, press the 
    [PAUSE] key. 
    Select the IP Address menu among “Printer IP Address”, “Socket Port”, “Gateway IP Address”, “Subnet 
    Mask”, “DHCP”, or “DHCP Client ID”. 
     
     
     
     
     
     
     
    !,$* 9[[
    !,3 $5(66
    Printer IP Address Setting 
    Gateway IP Address Setting 
    Subnet Mask Setting 
    Socket Port Setting 
    DHCP Setting 
    [PAUSE] 
    !,3 $5(66
    35,17(5 ,3 $5(6
    !,3 $5(66
    *$7(:$< ,3 $5(6
    !,3 $5(66
    68%1(7 0$6.
    !,3 $5(66
    62&.(7 3257
    !,3 $5(66
    +&3
    !,3 $5(66
    [RESTART] [FEED] 
    [RESTART] [FEED] 
    [RESTART] [FEED] 
    [RESTART] [FEED] 
    [RESTART] [FEED] 
    DHCP ID Setting !,3 $5(66
    +&3 &/,(17 ,
    [RESTART] [FEED] 
    [RESTART] 
    [FEED] 
    35,17(5 ,3 $5(6
    68%1(7 0$6.
    62&.(7 3257
    *$7(:$< ,3 $5(6
    +&3
    +&3 &/,(17 , 
    						
    							5. SYSTEM MODE EO18-33012A
     
     
    5.9 IP ADDRESS SETTING
     
    5-59 
    (1) Printer IP Address, Gateway IP Address, and Subnet Mask Settings 
    After selecting the menu set the IP address using the following procedure. 
     
     
    Set the first 3 digit value with the 
    [FEED] or 
    [RESTART] key.
     
     
    Press the 
    [PAUSE] key to move the cursor to the next 3 digit value. 
    Set the next values in the same way. 
     
     
     
    NOTES: 1. Pressing the [FEED] key one time causes a –1 change.  Pressing the [RESTART] key 
    one time causes a +1 change.
     
     
    2.  If holding the [FEED] or [RESTART] key for 0.5 seconds or longer in the parameter 
    setting, the key is entered continuously.
     
     
    After the last 3 digit value is set, press the 
    [PAUSE] key.  The display will show “GATEWAY IP 
    ADDRESS”.  Set the values for the Gateway IP Address and Subnet Mask, respectively. 
     
    (2) Socket Port Setting 
    To set the socket port number, follow the procedure below.  
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    
     
    3257 21 
    
    !,3 $5(66
    3257 2)) 
    3257 21 
    3257 21
    
    3257 21 
    
    62&.(7 3257
    Select “PORT ON” or “PORT OFF” with the [RESTART] 
    or [FEED] key.  When “PORT ON” is selected, a port 
    number is displayed.  Pressing the [PAUSE] key allows 
    the port number setting.  
    [PAUSE] 
    [PAUSE] 
    [PAUSE] 
    [PAUSE] 
    Enter the 5th digit of the port number with the 
    [RESTART] or [FEED] key.  Pressing the 
    [PAUSE] key allows the 4th digit setting. 
    Repeat this procedure until the 1
    st digit setting has 
    been completed.  
    Enter each digit of the port 
    number with the [RESTART] 
    or [FEED] 
    key.  
    [PAUSE] 
    [RESTART] 
    [FEED] 
    [RESTART] 
    [FEED] 
    3257 21 
    3257 21 
    3257 21 
    3257 21 
    3257 2))  
    						
    							5. SYSTEM MODE EO18-33012A
     
     
    5.9 IP ADDRESS SETTING
     
    5-60 
    (3) DHCP and DHCP ID Settings 
    To set the DHCP and the DHCP ID, follow the procedure below.  
     
     
     
     
    !,3 $5(66
    +&3 21
    !,3 $5(66
    +&3 &/,(17 ,
    02( $6&,,
    +&3 &/,(17 ,
    02( +(;
    +&3 &/,(17 ,
    ))))))))))))))))
    ))))))))))))))))
    !,3 $5(66
    [PAUSE] 
    [PAUSE] 
    [PAUSE] 
    [PAUSE] 
    After the 16th byte value is set, the 
    display returns to “IP ADDRESS”. 
    !,3 $5(66
    +&3
    !,3 $5(66
    +&3 2))
    [PAUSE] 
    Select ON or OFF with the [FEED] or 
    [RESTART] key. 
    Select ASCII or HEX with the 
    [FEED] or [RESTART] key. 
    Enter the numeric values for each byte 
    (1st byte to 16th byte) with the [FEED] or 
    [RESTART] key. 
    [PAUSE] 
    Repeat entering the values 
    until the 16th byte value is 
    entered. 
    [RESTART] 
    [FEED] +&3 21
    +&3 2))
    DHCP is available.  DHCP is unavailable. 
    DHCP setting 
    Select “DHCP ON” or “DHCP OFF” with the [FEED]
     
    or [RESTART]
     key. 
    [RESTART] 
    [FEED] 02( +(;
    02( $6&,,
    DHCP ID entering mode setting 
    Select “ASCII” or “HEX” with the [FEED] or [RESTART] key. 
    DHCP ID setting 
    Set the ID from 1st byte to 16th byte. 
    NOTE:  HEX mode is used here.  For ASCII mode, data of 
    each byte will be showed in ASCII characters. 
     FF FF FF FF FF FF FF FF  (1st byte)  (2nd byte) (3rd byte)  (4th byte)  (5th byte)  (6th byte)  (7th byte)  (8th byte) 
     FF FF FF FF FF FF FF FF (9th byte)(10th byte)(11th byte)(12th byte)(13th byte)(14th byte)(15th byte)(16th byte) 
    ))))))))))))))))
    ))))))))))))))))
    [RESTART] 
    ))))))))))))))
    ))))))))))))))))
    [PAUSE] 
    [FEED] 
    [FEED] 
    )))))))))))))
    ))))))))))))))))
    Example 
    [RESTART] 
    [FEED] 
    FF 
    FE 
    FD 
     
     
    A0 
    9F 
    9E 
     
     
    03 
    02 
    01  
    						
    							5. SYSTEM MODE EO18-33012A
     
     
    5.10 BASIC SETTING
     
    5-61 
    5.10 BASIC SETTING 
    „Outline of Basic Setting 
    Setting the BASIC specification and Trace specification to be enabled/disabled, and displaying the 
    program file, data file, and area file are available in this mode. 
    The Basic Setting menu contains the following.  
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    While pressing the 
    [FEED] and 
    [PAUSE] keys at the same time, turn on the printer.  Hold both keys 
    until the “DIAG. Vx.x” Message appears.  
     
     
    Press the 
    [FEED] key 8 times. 
    The printer is at the start of the BASIC setting menu. 
     
     
    When “BASIC” appears, press the 
    [PAUSE] key. 
     
     
      5.10.1  Basic Specification Selection Mode 
      Select whether the Basic specification is enable or not.  
     
     
     
     
     
     
     
     
     
     
     
     
    !,$* 9[[
    !%$6,&
    %$6,& (1$%/(
    [PAUSE] 
    %$6,& 2))
    %$6,& 21
    ),/( 0$,17(1$1&(
    [PAUSE] 
    [RESTART] [FEED] 
    “BASIC ON” or “BASIC OFF” is selected each time the 
    [RESTART]
     or [FEED]
     key is pressed. 
     
    Basic specification selection is completed by pressing the 
    [PAUSE] 
    key.  
    BASIC Specification Selection Mode 
    BASIC File Browser 
    BASIC Trace Selection Mode 
    [PAUSE] 
    !%$6,&
    %$6,& (1$%/(
    !%$6,&
    ),/( 0$,17(1$1&(
    !%$6,&
    %$6,& 75$&(
    !%$6,&
    [RESTART] [FEED] 
    [RESTART] [FEED] 
    [RESTART] [FEED]  
    						
    All Toshiba manuals Comments (0)

    Related Manuals for Toshiba Bsx4t Manual