5. SYSTEM MODE EO18-33012A 5.3 SELF-DIAGNOSTIC TEST 5- 12 (6) PC Card Slot Check CARD SLOT 1 ATA SLOT 2 LAN (7) Sensor 1 Check The status of the Strip Sensor, Ribbon Feed Motor Sensor, Ribbon Take-up Motor Sensor, Rewinder Overflow Sensor, Cutter Home Position Sensor, Print Head Up Sensor, and Print Block Open Sensor are printed. SENSOR1 00000000 , 0 1 1 1 0 0 1 1 ATA: ATA Card is inserted. LAN: LAN card is inserted. FSH: Flash memory card is inserted. NO: Unformatted ATA card/Flash memory card or no card is inserted. Slot PCMCIA Card Printer block open sensor status 1: Print head close Cutter home position sensor status 0: Home position 1: Other position Rewinder overflow sensor status 0: Normal 1: Overflow Ribbon take-up motor sensor status 0: The detecting point is positioned outside the slit. 1: The detecting point is positioned inside the slit. Fixed to 0. Ribbon feed motor sensor status 0: The detecting point is positioned outside the slit. 1: The detecting point is positioned inside the slit. Fixed to 0. Strip sensor status 0: The label is not detected. 1: The label is detected. Printer head up sensor status 1: Head down
5. SYSTEM MODE EO18-33012A 5.3 SELF-DIAGNOSTIC TEST 5- 13 Sensor/Switch Print status content description Printer block open sensor Detects the Open or Close status of the printer block. W hen the printer block is closed, printing is performed. Print head up sensor Detects the Up or Down status of the print head. W hen the print head is down, printing is performed. Cutter home position sensor Indicates whether or not the cutter is at the home position. Rewinder overflow sensor Detects the amount of the rewound backing paper in strip printing mode. If the amount overflows the capacity, printing cannot be performed. Ribbon take-up motor sensor Ribbon feed motor sensor Controls ribbon motor rotation by detecting the slit on the ribbon take-up motor and the ribbon feed motor. Indicates the position of the slit sensor. Strip sensor Detects whether or not the label is at the paper outlet in strip printing mode. W hen the label is not detected, the printer feeds the label at the print start position. (8) Sensor 2 Check The status of the Print Head Thermistor, Environmental Temperature Thermistor, Heat Sink Thermistor, Black Mark Sensor, Feed Gap Sensor, and Ribbon End Sensor are printed. SENSOR2 [H]20 °C [A]22 °C [S]25 °C [R]4.2V [T]2.5V [E]2.7V [RANK] 7 Ribbon end sensor status: 0.0 – 5.0V Heat sink thermistor status: 25° C, 80° C, 90° C Feed gap sensor status: 0.0 – 5.0V Black mark sensor status: 0.0 – 5.0V Print head thermistor status: 0° C - 86° C Environmental temperature thermistor status: 0 - 86° C If it is undetectable, “--° C “ is printed. Print head resistance rank: 0 – 15 B-SX4T B-SX5T Print Head Resistance Rank Average Resistance (ohm) Average Resistance (ohm) 0 748 ~ 758 1100~ 1116 1 759 ~ 770 1117 ~ 1133 2 771 ~ 782 1134 ~ 1150 3 783 ~ 794 1151 ~ 1168 4 795 ~ 806 1169 ~ 1185 5 807 ~ 818 1186 ~ 1203 6 819 ~ 831 1204 ~ 1222 7 832 ~ 843 1223 ~ 1240 8 844 ~ 856 1241 ~ 1259 9 857 ~ 869 1260 ~ 1279 10 870 ~ 883 1280 ~ 1298 11 884 ~ 896 1299 ~ 1318 12 897 ~ 910 1319 ~ 1338 13 911 ~ 924 1339 ~ 1358 14 925 ~ 938 1359 ~ 1379 15 939 ~ 952 1380 ~ 1400
5. SYSTEM MODE EO18-33012A 5.3 SELF-DIAGNOSTIC TEST 5- 14 (9) Expansion I/O Interface Check EXP.I/O OK Connect the jig like below to the Expansion I/O PC board’s connector and perform a loop back check. (10) Internal Serial Interface Check EX.232C NG Connect the jig like below to the serial interface connector and perform a loop back check. Loopback test OK: The circuit has no problem. NG: The circuit has a problem or loopback jig is not attached. Expansion I/O PC board OK: The circuit has no problem. NG: The circuit has a problem or loopback jig is not attached. Internal Serial Interface R R R R R R R Vcc LED R = 300 ohms Connector: FCN-781P024-G/PGND 121110987645312 242322212019181617151314
5. SYSTEM MODE EO18-33012A 5.3 SELF-DIAGNOSTIC TEST 5- 15 5.3.5 Print Head Element Check When the Self-Diagnostic Test result is printed, the message returns to “DIAG. Vx.x”. Press the [PAUSE] key three times and [FEED] key twice. The printer is ready to check the print head to see if there is any problem with the print head. Press the [PAUSE] key to start. The printer starts checking the print head. If there is no problem with the print head, the print head check is complete. Press the [PAUSE] key to return to “DIAG. Vx.x”. If there is a problem with the print head, the following message is displayed. Press the [PAUSE] key to return to “DIAG. Vx.x”. NOTES: 1. Make sure that the Top Cover is closed before starting the print head check. 2. If “HEAD ERROR” appears, the print head element may be damaged. Replace the print head. 3. The print head element check can be performed at the power on time. For selecting this function, refer to Section 5.4 Parameter Setting. !,$* 9[[ +($ &+(&. !,$* 9[[ &+(&.,1* !,$* 9[[ 1250$/ (1 !,$* 9[[ +($ (5525
5. SYSTEM MODE EO18-33012A 5.4 PARAMETER SETTING 5-16 5.4 PARAMETER SETTING „Outline of Parameter Setting In the Parameter Setting mode, various kinds of parameters, such as communication, key, LCD, etc. can be set. This will allow the use of the printer to comply with your operating conditions. The Parameter Setting menu contains the following: Character code selection Zero font code selection Baud rate selection Data length selection Stop bit selection Parity selection Transmision control code selection LCD message selection Auto forward wait selection Head up cut/rewinder selection Ribbon save function selection Control code selection Strip wait status selection [FEED] key selection [PAUSE] !3$5$0(7(5 6(7 )217 &2( 3& !3$5$0(7(5 6(7 =(52 )217 !3$5$0(7(5 6(7 63(( ESV !3$5$0(7(5 6(7 $7$ /(1* ELWV !3$5$0(7(5 6(7 6723 %,7 ELW !3$5$0(7(5 6(7 3$5,7< (9(1 !3$5$0(7(5 6(7 ;215($< $872 !3$5$0(7(5 6(7 /& (1*/,6+ !3$5$0(7(5 6(7 )25:$5 :$,7 2)) !3$5$0(7(5 6(7 +8 &875: 2)) !3$5$0(7(5 6(7 5,%%21 6$9( 21 !3$5$0(7(5 6(7 &2( (6&/)18/ !3$5$0(7(5 6(7 3((/ 2)) 676 2)) !3$5$0(7(5 6(7 )(( .(< )(( !3$5$0(7(5 6(7 .$1-, &2( 7
5. SYSTEM MODE EO18-33012A 5.4 PARAMETER SETTING 5-17 NOTE: Baud rate, Data length, Parity, and Transmission control code should be set to the same values as those of the host computer. Failure to do this causes improper operation. While pressing the [FEED] and the [PAUSE] keys at the same time, turn on the printer. Hold both keys until the “DIAG. Vx.x” message appears. Press the [FEED] key. The printer is at the start of the Parameter Setting menu. 5.4.1 Character Code Selection With this parameter you can select a character font code. When “PARAMETER SET” appears, press the [PAUSE] key. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. After selecting the character code, press the [PAUSE] key. NOTES: 1. When pressing the [FEED] and [RESTART] keys at the same time in the parameter setting, the message returns to “PARAMETER SET”. 2. If holding the [FEED] or [RESTART] key for 0.5 seconds or longer in the parameter setting the key is entered continuously. 3. A changed parameter becomes enabled by pressing the [PAUSE]. !3$5$0(7(5 6(7 )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( $UDELF )217 &2( /$7,1 )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( 3& )217 &2( 3& [RESTART] [FEED] !,$* 9[[ !3$5$0(7(5 6(7
5. SYSTEM MODE EO18-33012A 5.4 PARAMETER SETTING 5-18 Example: Character code table Printable characters depend on the fonts. The fonts of the following characters are Times New Roman, Helvetica, Letter Gothic, Prestige Elite, Courier, and Gothic 725 Black PC-850 PC-8 PC-852 PC-857 B-851 B-855
5. SYSTEM MODE EO18-33012A 5.4 PARAMETER SETTING 5-19 PC-1250 PC-1251 PC-1252 PC-1253 PC-1254 PC-1257
5. SYSTEM MODE EO18-33012A 5.4 PARAMETER SETTING 5-20 LATIN9 Arabic NOTE: Euro font codes are changeable. For details, refer to Euro Code Selection of Section 5.4 Parameter Setting. 5.4.2 Zero Font Code Selection With this parameter you can select the way to indicate zero between “0” and “ Ø”. When “PARAMETER SET” appears, press the [PAUSE] key and the [FEED] key. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. After selecting the zero font code, press the [PAUSE] key. NOTE: The following fonts do not support a zero with slash. Bit Map Font: OCR-A, OCR-B, GOTHIC 725 Black Outline Font: Price Font 1, Price Font 2, Price Font 3, DUTCH 801 Bold, BRUSH 738 Regular, GOTHIC 725 Black, True Type Font !3$5$0(7(5 6(7 =(52 )217 =(52 )217 =(52 )217Ø [RESTART] [FEED] (W ithout slash) (W ith slash)
5. SYSTEM MODE EO18-33012A 5.4 PARAMETER SETTING 5-21 5.4.3 Baud Rate Selection With this parameter you can select the baud rate of the RS-232C interface. When “PARAMETER SET” appears, press the [PAUSE] key and the [FEED] key twice. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. After selecting the baud rate, press the [PAUSE] key. 5.4.4 Data Length Selection With this parameter you can select the communication data length of the RS-232C interface. When “PARAMETER SET” appears, press the [PAUSE] key and the [FEED] key 3 times. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. After selecting the data length, press the [PAUSE] key. 5.4.5 Stop Bit Selection With this parameter you can select the stop bit of the RS-232C interface. When “PARAMETER SET” appears, press the [PAUSE] key and the [FEED] key 4 times. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. After selecting the stop bit, press the [PAUSE] key. $7$ /(1* ELWV $7$ /(1* ELWV !3$5$0(7(5 6(7 $7$ /(1* ELWV [RESTART] [FEED] 6723 %,7 ELW 6723 %,7 ELWV !3$5$0(7(5 6(7 6723 %,7 ELW [RESTART] [FEED] !3$5$0(7(5 6(7 63(( ESV [RESTART] [FEED] 63(( ESV 63(( ESV 63(( ESV 63(( ESV 63(( ESV 63(( ESV