5. SYSTEM MODE EO18-33012A 5.4 PARAMETER SETTING 5-32 5.4.26 Pre-Strip Selection With this parameter you can select whether or not the Pre Strip function is activated. When “PARAMETER SET” appears, press the [PAUSE] key and the [FEED] key 25 times. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. After selecting the Pre Strip, press the [PAUSE] key. NOTE: When the print speed is set to 10”/sec., the pre-strip function will be activated regardless of this parameter setting. 5.4.27 Back Feed Speed Selection With this parameter you can select the speed of back feed. When “PARAMETER SET” appears, press the [PAUSE] key and the [FEED] key 26 times. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. After selecting the Back Feed Speed, press the [PAUSE] key. !3$5$0(7(5 6(7 35( 3((/ 2)) 2)) 35( 3((/ 2)) 2)) 35( 3((/ 2)) 21 [RESTART] [FEED] Unavailable Available !3$5$0(7(5 6(7 %$&. 63(( 67 %$&. 63(( 67 %$&. 63(( /2: [RESTART] [FEED] STD: 3 inch/second LOW : 2 inch/second
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-33 5.5 PRINTER PARAMETER FINE ADJUSTMENT „Outline of Printer Parameter Fine Adjustment In the Printer Parameter Fine Adjustment mode, you can fine adjust each parameter, such as Print tone, Print start position, Threshold, etc. which are set by the PC command. This is useful when using several types of media by turns or when the print start position or cut/strip position is required to be fine adjusted. The Printer Parameter Fine Adjustment menu contains the following. Feed Length Fine Adjustment Cut/Strip Position Fine Adjustment Back Feed Length Fine Adjustment X Axis Fine Adjustment Print Tone Fine Adjustment (Thermal Transfer) Print Tone Fine Adjustment (Thermal Direct) Ribbon Motor Drive Voltage Fine Adjustment (Take-up Motor) Ribbon Motor Drive Voltage Fine Adjustment (Feed Motor) Threshold Fine Adjustment (Black Mark Sensor) Threshold Fine Adjustment (Feed Gap Sensor) [PAUSE] !$-867 6(7 )(( $-PP !$-867 6(7 &87 $- PP !$-867 6(7 %$&. $- PP !$-867 6(7 ; $-867 PP !$-867 6(7 721( $-7! !$-867 6(7 721( $-! !$-867 6(7 5%1 $- ):! !$-867 6(7 5%1 $- %.! !$-867 6(7 7+5(6+2/5!9 !$-867 6(7 7+5(6+2/7!9 !$-867 6(7 [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART] [FEED] [RESTART]
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-34 While pressing the [FEED] and [PAUSE] keys at the same time, turn on the printer. Hold both keys until the “DIAG. Vx.x” Message appears. Press the [FEED] key twice. The printer is at the start of the Printer Parameter Fine Adjustment menu. NOTES: 1. When pressing the [FEED] and [RESTART] keys at the same time in the parameter setting, the message returns to “ADJUST SET”. 2. If holding the [FEED] or [RESTART] key for 0.5 seconds or longer in the Printer Parameter Fine Adjustment, the key is entered continuously. 3. A changed parameter becomes enabled by pressing the [PAUSE]. 4. Use the [FEED] or [RESTART] key to select a desired value or option. 5.5.1 Feed Length Fine Adjustment With this parameter you can fine adjust the feed length. When “ADJUST SET” appears, press the [PAUSE] key. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. [FEED] key: Pressing the [FEED] key one time causes a –0.5mm change, up to –50.0 mm. [RESTART] key: Pressing the [RESTART] key one time causes a +0.5mm change, up to +50.0 mm. After completing the fine adjustment, press the [PAUSE] key. !,$* 9[[ !$-867 6(7 !$-867 6(7 )(( $- PP [RESTART] [FEED] )(( $-PP )(( $-PP )(( $-PP )(( $-PP )(( $-PP )(( $-PP )(( $-PP
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-35 · Feed Length Fine Adjustment (Example) NOTE: The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this parameter. The maximum feed length fine adjustment value is ±50.0mm. When the value reached the maximum, the value remains unchanged even if the subsequent fine adjustment is performed. 5.5.2 Cut/Strip Position Fine Adjustment With this parameter you can fine adjust the cut or strip position. When “ADJUST SET” appears, press the [PAUSE] key and the [FEED] key. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. [FEED] key: Pressing the [FEED] key one time causes a –0.5mm change, up to –50.0 mm. [RESTART] key: Pressing the [RESTART] key one time causes a +0.5mm change, up to +50.0 mm. After completing the fine adjustment, press the [PAUSE] key. !$-867 6(7 &87 $- PP [RESTART] [FEED] &87 $-PP &87 $-PP &87 $-PP &87 $-PP &87 $-PP &87 $-PP &87 $-PP
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-36 · Cut Position Fine Adjustment (Example) NOTES: 1. Cut issue is available only when the optional cutter unit (B-7208-QM) is installed. 2. The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this parameter. The maximum cut position fine adjustment value is ±50.0mm. When the value reached the maximum, the value remains unchanged even if the subsequent fine adjustment is performed. · Strip Position Fine Adjustment (Example) NOTE: The print stop position when printing the label in strip mode varies according to label length as the strip mode printing stops so that the edge of the strip shaft is 4 mm from the middle of the gap. This is because the gap length is programmed as 2 mm. When the gap length is 5 mm or more, the effective print length should be set to the value obtained by subtracting 2mm from the label pitch, that is, set the gap length to 2 mm. If the print format hangs over the gap as a result, correct the print start position.
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-37 5.5.3 Back Feed Length Fine Adjustment With this parameter you can fine adjust the Back Feed Length. When “ADJUST SET” appears, press the [PAUSE] key and the [FEED] key twice. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. [FEED] key: Pressing the [FEED] key one time causes a –0.5mm change, up to –9.5 mm. [RESTART] key: Pressing the [RESTART] key one time causes a +0.5mm change, up to +9.5 mm. After completing the fine adjustment, press the [PAUSE] key. · Back Feed Length Fine Adjustment (Example) NOTE: The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this parameter. The maximum back feed length fine adjustment value is ±9.5mm. When the value reached the maximum, the value remains unchanged even if the subsequent fine adjustment is performed. !$-867 6(7 %$&. $- PP [RESTART] [FEED] %$&. $-PP %$&. $-PP %$&. $-PP %$&. $-PP %$&. $-PP %$&. $-PP %$&. $-PP
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-38 5.5.4 X Axis Fine Adjustment With this parameter you can fine adjust the print position on X Axis. When “ADJUST SET” appears, press the [PAUSE] key and the [FEED] key 3 times. Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option. [FEED] key: Pressing the [FEED] key one time causes a –0.5mm change, up to –99.5 mm. [RESTART] key: Pressing the [RESTART] key one time causes a +0.5mm change, up to +99.5 mm. After completing the fine adjustment, press the [PAUSE] key. · X-Axis Fine Adjustment (Example) !$-867 6(7 ; $-867 PP [RESTART] [FEED] ; $-867 PP ; $-867 PP ; $-867 PP ; $-867 PP ; $-867 PP ; $-867 PP ; $-867 PP
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-39 NOTES: 1. The X Axis fine adjustment is performed to fine adjust the print position in horizontal direction (left or right). 2. Adjust the X axis within the effective print range. After the value reaches the coordinate 0, the value remains unchanged even if the subsequent fine adjustment is performed in the negative direction. 3. This adjustment cannot be used in the Self Test mode or Test print. 4. The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this parameter. The maximum X axis fine adjustment value is ±99.5mm. When the value reached the maximum, the value remains unchanged even if the subsequent fine adjustment is performed. 5.5.5 Print Tone Fine Adjustment (Thermal Transfer/Thermal Direct Print) With this parameter you can fine adjust the Print Tone. When “ADJUST SET” appears, press the [PAUSE] key and the [FEED] key 4 times to enter the Print Tone Fine Adjustment (Thermal transfer print) menu. To change the screen to the Print Tone Fine Adjustment (Thermal direct print), press the [FEED] key again. When the LCD display shows “TONE ADJ.” or “TONE ADJ.”, press the [PAUSE] key to start. And then, use the [FEED] or [RESTART] key to select a desired option. [FEED] key: Pressing the [FEED] key one time causes a –1 tone change, up to –10 tones. [RESTART] key: Pressing the [RESTART] key one time causes a +1 tone change, up to +10 tones. After completing the fine adjustment, press the [PAUSE] key. NOTES: 1. The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this parameter. The maximum print tone fine adjustment value is ±10 (thermal transfer print) or +7/-10 (thermal direct print). When the value reached the maximum, the value remains unchanged even if the subsequent fine adjustment is performed. 2. This is useful when print tone is required to be fine adjusted e.g.) When the ribbon is changed to different type. !$-867 6(7 721( $-! !$-867 6(7 721( $-7! Thermal Transfer Thermal Direct [RESTART] [FEED] 721( $-7! 721( $-7! 721( $-7! 721( $-7! 721( $-7! 721( $-! 721( $-! 721( $-! 721( $-! 721( $-! Darker Lighter Thermal Transfer Print Thermal Direct Print Standard
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-40 5.5.6 Ribbon Motor Voltage Fine Adjustment (Feed/Take-up Motor) With this parameter you can fine adjust the Ribbon Motor Voltage (Torque). When “ADJUST SET” appears, press the [PAUSE] key and the [FEED] key 6 times to enter the Ribbon Motor Voltage Fine Adjustment (Take-up Motor) menu. To change the screen to the Ribbon Motor Voltage Fine Adjustment (Feed Motor), press the [FEED] key again. When the LCD display shows “RBN ADJ” or “RBN ADJ”, press the [PAUSE] key to start. And then, use the [FEED] or [RESTART] key to select a desired option. [FEED] key: Pressing the [FEED] key one time causes a –1 step change, up to –15 steps. [RESTART] key: Pressing the [RESTART] key one time causes a +1 step change, up to +0 steps. After completing the fine adjustment, press the [PAUSE] key. NOTES: 1. The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this parameter. The maximum ribbon motor voltage fine adjustment value is -15. When the value reached the maximum, the value remains unchanged even if the subsequent fine adjustment is performed. 2. One step corresponds to 5% of the standard voltage and up to 75% of the voltage can be decreased. 3. Please make this adjustment if a ribbon error occurs though the ribbon is proper. !$-867 6(7 5%1 $-%.! !$-867 6(7 5%1 $-):! Take-up Motor Feed Motor [RESTART] [FEED] 5%1 $-):! 5%1 $-):! 5%1 $-):! 5%1 $-):! 5%1 $-):! 5%1 $-%.! 5%1 $-%.! 5%1 $-%.! 5%1 $-%.! 5%1 $-%.! Take-up Motor Feed Motor
5. SYSTEM MODE EO18-33012A 5.5 PRINTER PARAMETER FINE ADJUSTMENT 5-41 5.5.7 Threshold Manual Fine Adjustment (Black Mark/Feed Gap Sensor) With this parameter you can fine adjust the Threshold of the Black Mark and Feed Gap Sensors. When “ADJUST SET” appears, press the [PAUSE] key and the [FEED] key 8 times to enter the Threshold Manual Fine Adjustment (Black Mark Sensor) menu. To change the screen to the Threshold Manual Fine Adjustment (Feed Gap Sensor), press the [FEED] key again. When the LCD display shows “THRESHOLD” or “THRESHOLD”, press the [PAUSE] key to start. And then, use the [FEED] or [RESTART] key to select a desired option. [FEED] key: Pressing the [FEED] key one time causes a –0.1V change, up to 0.0V. [RESTART] key: Pressing the [RESTART] key one time causes a +0.1V change, up to +4.0V. After completing the fine adjustment, press the [PAUSE] key. NOTE: This is useful to fine adjust the threshold when the media issue is improper even after the sensor threshold setting is performed. (See Section 6.1 Threshold Setting.) !$-867 6(7 7+5(6+2/7!9 !$-867 6(7 7+5(6+2/5!9Black Mark Sensor Feed Gap Sensor [RESTART] [FEED] 7+5(6+2/5!9 7+5(6+2/5!9 7+5(6+2/5!9 7+5(6+2/5!9 7+5(6+2/5!9 7+5(6+2/7!9 7+5(6+2/7!9 7+5(6+2/7!9 7+5(6+2/7!9 7+5(6+2/7!9 Black Mark Sensor Feed Gap Sensor