CMU Procedures CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL TITLE: Protocol Assignments Page 2 of 5 StEP NO. PROMPT/EXPLANATION 9. TIMED DISCONNECT (Y,N) = a Requests whether the specified protocol will use the timed discon- a = Y = Yes; a = N = No. nect option. If Y (Yes), go to step 10; if N (No), go to step 11. IO. TIMED DISC 5 SEC UNITS (l-254) = nnn I Requests the seconds setting of the disconnect timer, in units of 5 nnn = timer setting in 5second units seconds (i.e., input 10 for 50...
Page 292
biu ut-w trA6jn CMU Procedures II”“U”Cl-,\~“JI‘LILc)---UJ,~ Issue 2, March 1986 CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL TITLE: Protocol Assignments STEP NO. PROMPT/EXPLANATION Page 3 of 5 i 8. CTS DELAY 10 MSEC UNITS (l-254) = nnn Enter the desired delay between FtTS and CTS, in 10 millisecond units nnn = timer setting in msec x 10. (iiieednter 1 for 10 msec, enter 2 for 20 msec, etc.). Procedure is corn-- 9. MODEM CONTROLLER EQUIPPED (Y,N) = a Enter Y (Yes) if the DCls using this protocol...
Page 293
bm uhi\i trAt)A T(cl”u”“-,\J”J a-i IL”-L-UJ lil CMU Procedures Issue 2, March 1986 CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL TITLE: Protocol Assignments 1 a f-EP NO. PROMPT/EXPLANATION Page 4 of 5 I r > _. DATA PROTCCOL NUMBER (O-31) = nn Requests protocol number to be cfanged. nn -= protocol number (O-31). 3. DISABLE VALID DATA SPEED(S) = nnnnn . . . nnnnn Requests the valid data speeds that are to be disabled for the speci- nnnnn = data speed(s); see Table 461.1. fied protocol. If more than...
Page 294
SATURN EPABX A30808-X5051-fi120-2-t3919 CMU Procedures Issue 2. March 1986 CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL TITLE: Protocol Assignments Page 5 of 5 Table 461.2 Answer Protocol Options for DCls Connected to DCE ALPHAMERIC INPUT DESCRIPTION DTFI Data Terminal Ready. RTS Request to Send. Table 461.3 Originate Protocol Options for DCls Connected to DCE ALPHAMERIC INPUT DESCFilPTlON DTR Data Terminal Ready. RTS Request to Send. Table 461.4 Disconnect Protocol for DCls Connected to...
Page 295
SATURN EPABX A30808-X5051-E120-i-B919 - CMU Procedures Issue 1, December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: SECURITY TITLE: CMU Security Code Assignments Access Level: 4 I SECURITY I Page 1 of 1 STEP NO. PROMPT/EXPLANATION OPERATOR INPUT 1. > DIS SECURITY I I I 2. SECURITY LEVEL (l-4) = n Requests security level for which password is to be displayed. Enter n = security level (l-4). (CR> to printout passwords for levels 1 through 4. 1. ) CHA SECURITY 2. SECURITY LEVEL (l-4) = n...
Page 296
SATURN EPABX A30808-X5051-E120-l-B919 - CMU Procedures Issue 1, December 1984 . . CUSTOMER MEMORY UPDATE PROCEDURE: SERVICE TITLE: Service State Assignments Access Level: 3, 4 1 SERVICE ] Page 1 of 1 STEP NO. PROMPT/EXPLANATION 1. ) DIS SERVICE 2. PORT EQUIPMENT NUMBER (WXYZ) = nnnn nrinn Requests PEN of item for which service status is requested. If range nnnn = valid PEN(s). of PENS required, enter two PENS separated by space. 3. MODE ((CR) OUT OF SERVICE MODE) = a.. .a . . . a.. .a...
Page 297
SATURN EPABX CMU Procedures A30808-X5051-E120-l-B919 Issue 1, December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: SMDRACCT TITLE: SMDR Account Code Assignments Access Level: 2, 3, 4 SMDRACCT Page 1 of 1 I PROMPT/EXPLANATION I 1. r~ > DIS SMDRACCT I 2. SMDR ACCOUNT NUMBER (I-11 DGTS) = nnnnnnnnnnn I Requests account number for which data is to be displayed. Enter nnnnnnnnnnn = account number (CR) for all account numbers. (O-99999999999). I I I I I 1. > ADD SMDRACCT I I I I I 2. NEW SMDR...
Page 298
SATURN EPABX A30808-X5051-E120-l-B919 - CMU Procedures Issue 1, December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: SMDRASSN TITLE: SMDR Assignments and Control Access Level: 3, 4 - STEP NO. PROMPT/EXPLANATION Page 1 of 2 1. ) DIS SMDRASSN I This procedure is used to display the current status of the recording output device(s). 2. TYPE (VOICE,DATA,BOTH,ALARM) = aaaaa I Requests which type of SMDR report parameters are to be dis- played. NOTE: Entering (CR) is the same as entering BOTH. aaaaa =...
Page 299
SATURN EPABX CMU Procedures A30808-X5051-E120-l-B919 Issue 1, December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: SMDRASSN TITLE: SMDR Assignments and Control Page 2 of 2 STEP NO. PROMPT/EXPLANATION I I I 1 ) ST0 SMDRASSN TYPE (VOICE,DATA,BOTH) = aaaaa Requests type of SMDR output to be stopped, either voice, data, or both types. aaaaa = VOICE (standard telephone reports); aaaaa = DATA (data call reports - OC II only); or aaaaa = BOTH (both types of reports). OUTPUT STATUS (HOLD/END) = aaaa...
Page 300
i - - SATURN EPABX A30808-X5051-E120-4-B919 CMU Procedures Issue 6, November 1985 CUSTOMER MEMORY UPDATE PROCEDURE: SPCLEQPT TITLE: Special Equipment Assignments Access Level: 3, 4 Page 1 of 6 I STEP NO. PROMF’T/EXPlANATlON I 1. > DIS SPCLEQPT 2. EQUIPMENT TYPE = aaaaaaaaa Requests type of special equipment for which data is to be dis- aaaaaaaaa = equipment type; MUSIC, played. If ZUNA, go to step 3; if RECANN, go to step 4; if PAGE, ZUNA. RECANN, PAGE, go to step 5. Enter (CR) for all....