Page 291

CMU Procedures 
CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL 
TITLE: Protocol Assignments 
Page 2 of 5 
StEP NO. PROMPT/EXPLANATION 
9. TIMED DISCONNECT (Y,N) = a 
Requests whether the specified protocol will use the timed discon- a = Y = Yes; a = N = No. 
nect option. If Y (Yes), go to step 10; if N (No), go to step 11. 
IO. TIMED DISC 5 SEC UNITS (l-254) = nnn 
I 
Requests the seconds setting of the disconnect timer, in units of 5 nnn = timer setting in 5second units 
seconds (i.e., input 10 for 50...

Page 292

biu ut-w trA6jn 
CMU Procedures II”“U”Cl-,\~“JI‘LILc)---UJ,~ 
Issue 2, March 1986 
CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL 
TITLE: Protocol Assignments 
STEP NO. PROMPT/EXPLANATION Page 3 of 5 
i 
8. CTS DELAY 10 MSEC UNITS (l-254) = nnn 
Enter the desired delay between FtTS and CTS, in 10 millisecond units nnn = timer setting in msec x 10. 
(iiieednter 1 for 10 msec, enter 2 for 20 msec, etc.). Procedure is corn-- 
9. MODEM CONTROLLER EQUIPPED (Y,N) = a 
Enter Y (Yes) if the DCls using this protocol...

Page 293

bm uhi\i trAt)A T(cl”u”“-,\J”J a-i IL”-L-UJ lil 
CMU Procedures Issue 2, March 1986 
CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL 
TITLE: Protocol Assignments 
1 a f-EP NO. PROMPT/EXPLANATION Page 4 of 5 
I 
r > 
_. DATA PROTCCOL NUMBER (O-31) = nn 
Requests protocol number to be cfanged. nn -= protocol number (O-31). 
3. DISABLE VALID DATA SPEED(S) = nnnnn . . . nnnnn 
Requests the valid data speeds that are to be disabled for the speci- nnnnn = data speed(s); see Table 461.1. 
fied protocol. If more than...

Page 294

SATURN EPABX A30808-X5051-fi120-2-t3919 
CMU Procedures Issue 2. March 1986 
CUSTOMER MEMORY UPDATE PROCEDURE: PROTOCOL 
TITLE: Protocol Assignments 
Page 5 of 5 
Table 461.2 Answer Protocol Options for DCls Connected to DCE 
ALPHAMERIC 
INPUT DESCRIPTION 
DTFI 
Data Terminal Ready. 
RTS Request to Send. 
Table 461.3 Originate Protocol Options for DCls Connected to DCE 
ALPHAMERIC 
INPUT DESCFilPTlON 
DTR Data Terminal Ready. 
RTS Request to Send. 
Table 461.4 Disconnect Protocol for DCls Connected to...

Page 295

SATURN EPABX A30808-X5051-E120-i-B919 - 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: SECURITY 
TITLE: CMU Security Code Assignments 
Access Level: 4 
I SECURITY 
I 
Page 1 of 1 
STEP NO. PROMPT/EXPLANATION OPERATOR INPUT 
1. > DIS SECURITY 
I I I 
2. SECURITY LEVEL (l-4) = n 
Requests security level for which password is to be displayed. Enter n = security level (l-4). 
(CR> to printout passwords for levels 1 through 4. 
1. ) CHA SECURITY 
2. SECURITY LEVEL (l-4) = n...

Page 296

SATURN EPABX A30808-X5051-E120-l-B919 - 
CMU Procedures Issue 1, December 1984 
. . 
CUSTOMER MEMORY UPDATE PROCEDURE: SERVICE 
TITLE: Service State Assignments 
Access Level: 3, 4 1 SERVICE ] 
Page 1 of 1 
STEP NO. PROMPT/EXPLANATION 
1. ) DIS SERVICE 
2. PORT EQUIPMENT NUMBER (WXYZ) = nnnn nrinn 
Requests PEN of item for which service status is requested. If range nnnn = valid PEN(s). 
of PENS required, enter two PENS separated by space. 
3. MODE ((CR) OUT OF SERVICE MODE) = a.. .a . . . a.. .a...

Page 297

SATURN EPABX 
CMU Procedures A30808-X5051-E120-l-B919 
Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: SMDRACCT 
TITLE: SMDR Account Code Assignments 
Access Level: 2, 3, 4 SMDRACCT 
Page 1 of 1 
I PROMPT/EXPLANATION 
I 
1. 
r~ > DIS SMDRACCT 
I 
2. SMDR ACCOUNT NUMBER (I-11 DGTS) = nnnnnnnnnnn 
I 
Requests account number for which data is to be displayed. Enter nnnnnnnnnnn = account number 
(CR) for all account numbers. (O-99999999999). 
I I I I 
I 1. 
> ADD SMDRACCT 
I 
I I I I 
2. NEW SMDR...

Page 298

SATURN EPABX A30808-X5051-E120-l-B919 - 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: SMDRASSN 
TITLE: SMDR Assignments and Control 
Access Level: 3, 4 - 
STEP NO. PROMPT/EXPLANATION Page 1 of 2 
1. ) DIS SMDRASSN 
I 
This procedure is used to display the current status of the recording output device(s). 
2. TYPE (VOICE,DATA,BOTH,ALARM) = aaaaa 
I 
Requests which type of SMDR report parameters are to be dis- 
played. 
NOTE: Entering (CR) is the same as entering BOTH. aaaaa =...

Page 299

SATURN EPABX 
CMU Procedures A30808-X5051-E120-l-B919 
Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: SMDRASSN 
TITLE: SMDR Assignments and Control 
Page 2 of 2 
STEP NO. PROMPT/EXPLANATION 
I 
I I 
1 
) ST0 SMDRASSN 
TYPE (VOICE,DATA,BOTH) = aaaaa 
Requests type of SMDR output to be stopped, either voice, data, 
or both types. aaaaa = VOICE (standard telephone reports); 
aaaaa = DATA (data call reports - OC II only); or 
aaaaa = BOTH (both types of reports). 
OUTPUT STATUS (HOLD/END) = aaaa...

Page 300

i - - 
SATURN EPABX 
A30808-X5051-E120-4-B919 
CMU Procedures 
Issue 6, November 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: SPCLEQPT 
TITLE: Special Equipment Assignments 
Access Level: 3, 4 
Page 1 of 6 
I STEP NO. PROMF’T/EXPlANATlON 
I 
1. > DIS SPCLEQPT 
2. EQUIPMENT TYPE = aaaaaaaaa 
Requests type of special equipment for which data is to be dis- aaaaaaaaa = equipment type; MUSIC, 
played. If ZUNA, go to step 3; if RECANN, go to step 4; if PAGE, ZUNA. RECANN, PAGE, 
go to step 5. Enter (CR) for all....