SATURN EPABX ‘A30808-X5051-E120-3-6919 CMU Procedures Issue 5, January 1986 CUSTOMER MEMORY UPDATE PROCEDURE: SYSTIMER TITLE: System Timers Page 2 of 3 Table 506.1 System Timers (Continued) ALPHAMERIC INPUT DESCRIPTION MODEMRESP NOANSRCL NOANSOUTG IGNOREHF RLTNOANS ALARMDURATION SERIAL STANDBYQ STNHOLDRCL STNHFMIN STNONHK TlWTNOALM TRKDISC TRKRLS SZACKFAIL TRKTRBL VOICEREJ Modem Response Failure (see Note 14) (OC II only). No Answer Recall. No Answer Recall on Outgoing Calls (see...
Page 322
SATURN EPAEX A30808-X5051-E120-3-B919 CMU Procedures Issue 5, January 1986 CUSTOMER MEMORY UPDATE PROCEDURE: SYSTIMER I - TITLE: System Timers Page 3 of 3 NOTES (Continued): 9. 10. 11. 12. 13. 14. 15. 16. 17. LCRONHKQ - LCR On-Hook Queue Delay. This timer determines how long an LCR user must wait, off-hook, for an idle trunk before the user is eligible for LCR on-hook queuing. Eligibility is signaled by the initiation of steady low tone. LCRONHKQFIL - LCR On-Hook Queue Filter. If a...
Page 323
SATURN EPABX A30808-X5051-E120-l-B919 - CMU Procedures Issue 1. December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: TCRLIST TITLE: Toll Code Restriction Lists Access Level: 3, 4 STEP NO. PROMPT/EXPLANATION Page 1 of 3 1. > DIS TCRLIST 2. TOLL CODE REST LIST NUM (O-19) = nn Requests restriction list number for which data is to be displayed. nn = list number (O-19); see Table 112.1. 1. > ADD TCRLIST 2. ASSIGN TYPE OR LIST? (T,L) = a Requests whether addition is to be a restriction type or list. If...
Page 324
SATURN EPABX A30808-X5051-El20-l-B919 CMU Procedures issue 1. December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: TCRLIST TITLE: Toll Code Restriction List Page 2 of 3 STEP NO. PROMPT/EXPLANATION 3. DELETE ALL MEMBERS? (Y, N) = a Requests whether all members of restriction list are to be deleted. a = Y = Yes, a = N = No. If N (No), go to step 4; if Y (Yes), procedure is completed. 4. OLD DIGIT COUNT (I-15) = nn Requests digit count of list to be deleted. nn = digit count (l-15). NOTE: Maximum digit...
Page 325
SATURN EPABX A30808-X5051-E120-l-8919 CMU Procedures Issue 1, December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: TCRLIST TITLE: Toll Code Restriction Lists Page 3 of 3 I STEP NO. PROMPT/EXPLANATION I 8. RESTRICTION LIST DIGITS (O-9, A) = n . . . n Requests new digits to be placed in restriction list. n . . n = restriction list digits; enter each digit, O-9, or A for “don’t care”. NOTE: Enter digits as a continuous string; do not separate by spaces. ALPHANUMERIC INPUT 0 1 2 3 4 5 6 7 8...
Page 326
I .-- SATURN EPABX CMU Procedures A30808-X5051-E120-l-B919 Issue 2. May 1986 CUSTOMER MEMORY UPDATE PROCEDURE: TENANT TITLE: Tenant Assignments Access Level: 2 Page 1 of 3 STEP NO. PROMPT/EXPLANATION 1 I I I. > DIS TENANT 2. TGRF? CGRP, = aaaa Requests the type of group information to be displayed. aaaa = TGRP = Tenant Group; TGRP - Tenant Group information; Go to step 3. aaaa = CGRP = Console Group. CGRP - Console Group information; Go to step 5. I 1 3. ENTER TENANT GROUP NUMBER = nnn...
Page 327
SATURN EPABX A30808-X5051-E120-l-8919 CMU Procedures Issue 2, May 1986 . ., . . - I ( I CUSTOMER WlEMORY UPDATE PROCEDURE: TENANT TITLE: Tenant Assignments STEP NO. PROMPT/EXPLANATION Page 2 of 3 6. ENTER CONSOLE ID STRING = aa.. .aa Requests Tenant Console display ID text string. aa.. .aa = any combination of alphanu- meric characters (8 maximum). 7. GROUP SERVED BY A CONSOLE Y/N = a L I Requests whether Tenant Group is to be served by a console. a = Y = Yes; a = N = No. Y - YES - The...
Page 328
I - - SATURN EPABX CMU Procedures A30808-X5051-E120-l-8919 issue 2, May 1986 CUSTOMER MEMORY UPDATE PROCEDURE: TENANT TITLE: Tenant Assignments Page 3 of 3 STEP NO. PROMPT/EXPLANATION 4. ENTER CONSOLE ID STRING = aa.. .aa Requests the new Tenant LDN Console display ID Text String. aa.. .aa = any combination of alphanu- meric characters (8 maximum). .I 5. ENTER CONSOLE GROUP NUMBER (O-12) P nn I Requests the number of the Console Group serving this Tenant Group. nn = console group number...
Page 329
SATURN EPABX A30808-X5051-E120-l-8919 - CMU Procedures Issue 1, December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: TIMEDATE TITLE: System Time/Date Change Access Level: 2, 3, 4 Page 1 of 1 1 STEP NO. PROMPT/EXPLANATION I 1. ) DIS TIMEDATE 1. ) CHA TIMEDATE 2. ENTER TIME (HH MM SS) = hh mm ss Requests that correct time be entered: hours, minutes, and seconds. hh = hours (O-23), Separate each by spaces. mm = minutes (O-59) ss = seconds (O-59). NOTE: Set time in terms of a 24-hour clock (e.g., 1...
Page 330
SATURN EPABX CMU Procedures A30808X5051-E120-3-B919 Issue 3, December 1985 CUSTOMER MEMORY UPDATE PROCEDURE: TRACE r-YE-l _ TITLE: Call Trace Data Access Level: 4 Page 3 of 2 STEP NO. PROMPT/EXPLANATION 1. ) BEG TRACE Requests that the printout of collected data begin. 2. LINES TO SEARCH FOR (HEX) = (@@@@) Requests the LST(s) stored in the trace buffer which is (are) to be printed. If no value is entered, the trace buffer entries are not screened for matching LST(s). If more than one,...