SATURN EPABX 
CMU Procedures A30808X5051-E120-3-B919 
Issue 5, May 1986 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKASSN 
TITLE: Trunk Assignments Page 6 of 6 
Table 101.3 Niaht Answer TvDes- 
pay-- 
NONE 
ANA 
SNAP 
ZUNAl 
ZUNA2 
ZUNA3 
ZUNA4 DESCRIPTION 
I 
Not assigned to night answer 
Assigned Night Answer 
Special Night Answer Position 
Zoned Universal Night Answer - Zone 1 
Zoned Universal Night Answer - Zone 2 
Zoned Universal Night Answer - Zone 3 
Zoned Universal Night Answer - Zone 4 . . ....

Page 352

/ 
I - 
-- 
SATURN EPABX A30808-X5051-E120-3-6919 
CMU Procedures Issue 3. December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments 
Access Level: 3, 4 
STEP NO. PROMPT/EXPLANATION 
1. ) DIS TRKGRP pEq 
Page 1 of 10 
1 2. 1 DISPLAY TRUNK GROUP(S) (O-31) = nn nn 
Reouests trunk group(s) for which data is to be displayed. If ranqe nn =’ trunk group number(s) (O-31). 
is desired, enter-two trunk group numbers separated-by a space. 
Enter (CR> to display all. 
3. DISP ALL...

Page 353

i - 
- 
SATURN EPABX 
CMU Procedures 
, 
A30808-X5051-E120-3-8919 
Issue 3. December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments 
STEP NO. PROMPT/EXPLANATION Page 2 of 10 
. ASSIGN OUTGOING PARAMETERS? (Y,N) = a 
Requests whether parameters are required for outgoing (or outgoing a = Y = Yes; a = N = No. 
portion of two-way) trunks. If Y (Yes), go to step 9; If N (No), go to 
step 13. 
. ALTERNATE TRUNK GROUPS (O-31) = nn . . . nn 
I 
Requests alternate trunk groups (3...

Page 354

i- 
SATURN EPABX A30808-X5051-E120-3-8919 
CMU Procedures Issue 3, December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments Page 3 of 10 
I STEP NO. PROMPT/EXPLANATION 
I 
19. DID CONVERSION TABLE INDEX (O-3) = n 
Requests conversion table number for conversion of incoming DID n = conversion table number (O-3) 
digits. 
20. DID NIGHT ANSWER TYPE = aaaaa 
Requests night answer type. If ANA, go to step’21; for others, go aaaaa = night answer type; 
to step 22. see Table...

Page 355

, 
I - 
- 
SATURN EPABX 
CMU Procedures A30808-X5051-E120-3-8919 
issue 3. December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments Page 4 of 10 
STEP NO. PROMPT/EXPLANATION 
I 
BUSY LAMP THRESHOLD (o-100) = nnn 
Requests threshold setting for trunk group busy lamp on attendant nnn = number of busy trunks (O-100). 
console, i.e., the number of busy trunks (O-100) in the trunk group 
to flash the associated lamp on attendant console. 
Enter (CR> for no change. 
NOTE: Busy...

Page 356

I - 
SATURN EPABX A30808-X5051-E120-3-8919 
CMU Procedures Issue 3. December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments 
STEP NO. PROMPT/EXPLANATION Page 5 of 10 
3. OUTGOING CONTROL SIGNALING = aaaaaa 
Requests type of outgoing signaling control for this trunk group. aaaaaa = outgoing control; 
Enter (CR) for no change. see Table 102.5. 
4. OUTGOING ADDR SIG (AlJTO,DP,DTMF) = aaaa 
Requests type of outgoing address signaling that applies to this 
aaaa = Signaling...

Page 357

I - 
-- 
SATURN EPABX A30808-X5051-E120-3-9919 
CMU Procedures issue 3. December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments 
STEP NO. PROMPT/EXPLANATION Page 6 of 10 
14. ACD HUNT GROUP NUMBER = nn 
Requests ACD group number assigned to this trunk group. nn = ACD group (O-63). 
Enter (CR) for no change. 
!5. CHANGE DID PARAMETERS? (Y/N = n 
Requests whether DID parameters are to be changed. If Y (yes) n = DID digits (O-5). 
go to Step 27; if N (no) go to step 33....

Page 358

SATURN EPABX A30808-X5051-E120-3-8919 
CMU Procedures Issue 3. December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments 
STEP NO. PROMPT/EXPLANATION Page 7 of 10 
35. TRUNK DATA COS (O-31) = nn 
Requests the trunk data COS to be assigned to this trunk group. nn = trunk data COS (O-31). 
Entering (CR> is the same as removing the data COS. 
Table 102.1 Suggested Attendant Display Characters 
ALPHAMERIC 
INPUT DESCRIPTION 
FX-aaaa Foreign Exchange Trunk - aaaa denotes city or...

Page 359

RN EPABX 
I Procedures ‘, ‘A30808-X5051-E120-2-6919 
issue 2, November 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Group Assignments 
Page 8 of 10 
ALPHAMERIC INPUT 
NONE 
TRKTOTRKO 
ASRO 
CBQ 
DMDR 
DAYCTRL 
DIDPREFIX 
DSRI 
DSRO 
EM4WIRE 
RCLTOANA 
NOANSRCLI 
NOANSRCLO 
REROUTE 
SMDRI 
SMDRO 
SPCLACCT 
SBYQ 
XFERSECURE Table 102.3 Trunk Group Miscellaneous Flags 
DESCRlpTlON 
No flags affected (applies only to CHANGE). 
Allow Trunk-toTrunk Connection Even if Both Trunks are Seized...

Page 360

.._ . . . 
I - 
- I 
SATURN EPABX 
CMU Procedures . A30808-X5051-E120-2-8919 
issue 2. November 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: TRKGRP 
TITLE: Trunk Grow Assianments 
Page 9 of 10 
INPUT 
NONE 
DELAY 
DIALTN 
IMMED 
WINK 
lYY,ca I”&,” ‘..““~~.‘..J,~“.J”...~ W”....“. “.J..” . . . . J 
DESCRIPTION 
None Assigned. 
Delay Dial Signal 
a. Incoming - The SATURN EPABX returns a delay signal within 150 ms after trunk 
seizure. The signal persists for no less than 140 ms and ends when the EPABX is 
ready...