Page 311
SATURN EPABX CMU Procedures A30808-X5051-E120-4-8919 Issue 7, January 1986 CUSTOMER MEMORY UPDATE PROCEDURE: STNASSN TITLE: Station Assignments Page 5 of 6 STEP NO. PROMPT/EXPLANATION I 16. ORIG PREF (NO,PRIME,LAST,IDLE)=aaaaa I Requests new originating line preference type for DPI. Enter (CR) for no change. aa = NO = no preference; aaaaa = PRIME = prime line; aaaa = LAST = last line used; aaaa = IDLE = idle line. 17. PRIVACY AUTOMATIC (ENA,DIS)=aaa Requests whether the automatic privacy...
Page 312
SATURN EPABX CMU Procedures CUSTOMER MEMORY UPDATE PROCEDURE: STNASSN TITLE: Station Assignments MNEMONICS USED IN THIS CMU PROCEDURE: Mnemonic ACD AICC CFW cos (CR) DPl2 FX PEN SMDR SP TMD TYPE VFAC Definition Automatic Call Distribution Automatic Incoming Call Connection Call Forwarding Class of Service Carriage Return (RETURN key) SIEMENS Single-Channel Digital Premium Instrument II Foreign Exchange Station Port Equipment Number Station Message Detail Recording Special...
Page 313
SATURN EPABX CMU Procedures A30808X5051-E120-2-B919 Issue 2. December 1985 CUSTOMER MEMORY UPDATE PROCEDURE: STNDATA TITLE: Station Data (Display) Access Level: 1, 2, 3, 4 STEP NO. PROMPT/EXPLANATION Page 1 of 1 I 1. > DIS STNDATA I 2. (DATA,DSS,DIRTRK,TRKGRP,FIXCFWD) = aaaaaa Requests type of station data to be displayed. If DATA, go to step aaaaaa = DATA, DSS, DIRTRK, FIXCFWD, 3; if DIRTRK, DSS, FIXCFWD, or TRKGRR procedure is completed. or TRKGRP 3. 1 (DCI,STN,MODEM,TRK) = aaaaa...
Page 314
SATURN EPABX A30808-X5051-E120-I-6919 - CMU Procedures Issue 1. December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: STNEXT TITLE: Station Extension Assignments pq Page 1 of 1 STEP NO. PROMPT/EXPLANATION 1. ) DIS STNEXT 2. DISP PRIME OR ALIAS NUMBERS = aaaaa Requests whether one or all “alias” extension number(s) is to be aaaaa = PRIME or ALIAS. displayed for the specified station number. If PRIME specified, go to step 3; if ALIAS specified, go to step 4. 3. ALIAS EXTENSION NUMBER = nnnn I I...
Page 315
“I >I VI II. Li I?-, CMU Procedures .-< ._-- ,.-_-. -I-.. L- .- Issue 4, December 1985 CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT TITLE: System Options Access Level: 3, 4 STEP NO. PROMPT/EXPLANATION Page 1 of 4 1 1. > DIS SYSOPT 2. SYSTEM OPTION ASSIGNMENT = aaaaaaaaa Requests which system option is to be displayed. Enter (CR) for all. aaaaaaaaa = options; see Table 502.1. > CHA SYSOPT I !. SYSTEM OPTION ASSIGNMENT = aaaaaaaaa I Requests which system option is to be changed. If FLAGS, go to...
Page 316
an, U,‘\l\( L;r-Pt~/ I \“YIIu-,.d_v I ilL” .r L., ,., CMU Procedures Issue 4, December 1965 CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT TITLE: System Options I STEP NO. PROMPT/EXPLANATION Page 2 of 4 10. NUMBER OF CALLS (O-255) = nnn If preceding input was OVCNT, requests number of calls required nnn = number of calls (O-255). at console to invoke special overflow procedure; if preceding input was CWLEDFLSH, requests the number of all types of queued calls to the attendant pool to cause the...
Page 317
SATURN EPABX CMU Procedures A30808-X5051-E120-4-B919 Issue 4, December 1985 CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT TITLE: System Options Page 3 of 4 ALPHAMERIC INPUT DESCRIPTION OVDEST OVCNT CWLEDFLSH CONFCO CASINTCP NIGHT SNAP SOAP SPCLACCT DUPLEX FLAGS SYSITE CONFTRKS Table 502.1 System Options Attendant Overflow Destination Attendant Overflow Threshold Call Waiting LED Flash Threshold Central Office Trunks Allowed in Conference Centralized Attendant Service Intercept (Note 1)...
Page 318
CMU Procedures Issue 4, December 1985 CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT TITLE: System Options Page 4 of 4 Table 502.3 SNAP and SOAP Destination Options ALPHAMERIC INPUT I DESCRIPTION I ACD EXTRN PILOT STN NONE Destination is ACD Group ‘ACD#” Destination is External Number Destination is Pilot Number “EXT#” Destination is Station Number “EXT#” No destination specified I ALPHAMERIC INPUT SNAP SOAP ZUNAl ZUNA2 ZUNA3 ZUNA4 . . Table 502.4 Attendant Overflow Destination...
Page 319
SATURN EPABX A30808-X5051-E120-i-B919 CMU Procedures Issue 1, December 1984 CUSTOMER MEMORY UPDATE PROCEDURE: SYSSIZE TITLE: System Sizing Assignments Access Level: 1 (For Display Purposes Only) STEP NO. PROMPT/EXPLANATION Page 1 of 1 1. ) DIS SYSSIZE NOTE: Displays number of entries in selected adjustable-length data tables. Sizes of these tables can be adjusted by Siemens personnel only. See Table 908.1 for definitions. Table 908.1 System Sizing Parameters ALPHAMERIC INPUT AUTHCODES CDRBS...
Page 320
SATURN EPABX CMU Procedures A30808-X5051-E120-3-6919 Issue 5. January 1986 CUSTOMER MEMORY UPDATE PROCEDURE: SYSTIMER TITLE: System Timers Access Level: 3, 4 STEP NO. PROMPT/EXPLANATION pq Page 1 of 3 1. ) DIS SYSTIMER 2. VARIABLE SYSTEM TIMER=a...a . . . a...a Requests timer value(s) to be displayed (10 max.). If more than one, a...a = timer; see Table 506.1. separate each by spaces. Enter (CR) to display all. 1. ) CHA SYSTIMER 2. VARIABLE SYSTEM TIMER=a...a Requests timer for which value...