Page 311

SATURN EPABX 
CMU Procedures A30808-X5051-E120-4-8919 
Issue 7, January 1986 
CUSTOMER MEMORY UPDATE PROCEDURE: STNASSN 
TITLE: Station Assignments 
Page 5 of 6 
STEP NO. PROMPT/EXPLANATION 
I 
16. ORIG PREF (NO,PRIME,LAST,IDLE)=aaaaa 
I 
Requests new originating line preference type for DPI. 
Enter (CR) for no change. aa = NO = no preference; 
aaaaa = PRIME = prime line; 
aaaa = LAST = last line used; 
aaaa = IDLE = idle line. 
17. PRIVACY AUTOMATIC (ENA,DIS)=aaa 
Requests whether the automatic privacy...

Page 312

SATURN EPABX 
CMU Procedures 
CUSTOMER MEMORY UPDATE PROCEDURE: STNASSN 
TITLE: Station Assignments 
MNEMONICS USED IN THIS CMU PROCEDURE: 
Mnemonic 
ACD 
AICC 
CFW 
cos 
(CR) 
DPl2 
FX 
PEN 
SMDR 
SP 
TMD 
TYPE 
VFAC Definition 
Automatic Call Distribution 
Automatic Incoming Call Connection 
Call Forwarding 
Class of Service 
Carriage Return (RETURN key) 
SIEMENS Single-Channel Digital Premium Instrument II 
Foreign Exchange 
Station Port Equipment Number 
Station Message Detail Recording 
Special...

Page 313

SATURN EPABX 
CMU Procedures A30808X5051-E120-2-B919 
Issue 2. December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: STNDATA 
TITLE: 
Station Data (Display) 
Access Level: 1, 2, 3, 4 
STEP NO. PROMPT/EXPLANATION Page 1 of 1 
I 
1. > DIS STNDATA 
I 
2. 
(DATA,DSS,DIRTRK,TRKGRP,FIXCFWD) = aaaaaa 
Requests type of station data to be displayed. If DATA, go to step aaaaaa = DATA, DSS, DIRTRK, FIXCFWD, 
3; if DIRTRK, DSS, FIXCFWD, or TRKGRR procedure is completed. or TRKGRP 
3. 1 (DCI,STN,MODEM,TRK) = aaaaa...

Page 314

SATURN EPABX A30808-X5051-E120-I-6919 - 
CMU Procedures Issue 1. December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: STNEXT 
TITLE: Station Extension Assignments 
pq 
Page 1 of 1 
STEP NO. PROMPT/EXPLANATION 
1. ) DIS STNEXT 
2. DISP PRIME OR ALIAS NUMBERS = aaaaa 
Requests whether one or all “alias” extension number(s) is to be aaaaa = PRIME or ALIAS. 
displayed for the specified station number. If PRIME specified, go 
to step 3; if ALIAS specified, go to step 4. 
3. ALIAS EXTENSION NUMBER = nnnn 
I I...

Page 315

“I >I VI II. Li I?-, CMU Procedures .-< ._-- ,.-_-. -I-.. L- .- Issue 4, December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT 
TITLE: System Options 
Access Level: 3, 4 
STEP NO. PROMPT/EXPLANATION Page 1 of 4 
1 
1. > DIS SYSOPT 
2. SYSTEM OPTION ASSIGNMENT = aaaaaaaaa 
Requests which system option is to be displayed. Enter (CR) for all. aaaaaaaaa = options; see Table 502.1. 
> CHA SYSOPT 
I 
!. SYSTEM OPTION ASSIGNMENT = aaaaaaaaa 
I 
Requests which system option is to be changed. If FLAGS, go to...

Page 316

an, U,‘\l\( L;r-Pt~/ I \“YIIu-,.d_v I ilL” .r L., ,., 
CMU Procedures Issue 4, December 1965 
CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT 
TITLE: System Options 
I STEP NO. PROMPT/EXPLANATION 
Page 2 of 4 
10. NUMBER OF CALLS (O-255) = nnn 
If preceding input was OVCNT, requests number of calls required nnn = number of calls (O-255). 
at console to invoke special overflow procedure; if preceding input 
was CWLEDFLSH, requests the number of all types of queued calls 
to the attendant pool to cause the...

Page 317

SATURN EPABX 
CMU Procedures A30808-X5051-E120-4-B919 
Issue 4, December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT 
TITLE: System Options Page 3 of 4 
ALPHAMERIC INPUT DESCRIPTION 
OVDEST 
OVCNT 
CWLEDFLSH 
CONFCO 
CASINTCP 
NIGHT 
SNAP 
SOAP 
SPCLACCT 
DUPLEX 
FLAGS 
SYSITE 
CONFTRKS Table 502.1 System Options 
Attendant Overflow Destination 
Attendant Overflow Threshold 
Call Waiting LED Flash Threshold 
Central Office Trunks Allowed in Conference 
Centralized Attendant Service Intercept (Note 1)...

Page 318

CMU Procedures Issue 4, December 1985 
CUSTOMER MEMORY UPDATE PROCEDURE: SYSOPT 
TITLE: System Options Page 4 of 4 
Table 502.3 SNAP and SOAP Destination Options 
ALPHAMERIC 
INPUT 
I DESCRIPTION 
I 
ACD 
EXTRN 
PILOT 
STN 
NONE Destination is ACD Group ‘ACD#” 
Destination is External Number 
Destination is Pilot Number “EXT#” 
Destination is Station Number “EXT#” 
No destination specified 
I 
ALPHAMERIC 
INPUT 
SNAP 
SOAP 
ZUNAl 
ZUNA2 
ZUNA3 
ZUNA4 
. . 
Table 502.4 Attendant Overflow Destination...

Page 319

SATURN EPABX A30808-X5051-E120-i-B919 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: SYSSIZE 
TITLE: System Sizing Assignments 
Access Level: 1 (For Display Purposes Only) 
STEP NO. PROMPT/EXPLANATION Page 1 of 1 
1. ) DIS SYSSIZE 
NOTE: Displays number of entries in selected adjustable-length data tables. 
Sizes of these tables can be adjusted by Siemens personnel only. 
See Table 908.1 for definitions. 
Table 908.1 System Sizing Parameters 
ALPHAMERIC 
INPUT 
AUTHCODES 
CDRBS...

Page 320

SATURN EPABX 
CMU Procedures A30808-X5051-E120-3-6919 
Issue 5. January 1986 
CUSTOMER MEMORY UPDATE PROCEDURE: SYSTIMER 
TITLE: System Timers 
Access Level: 3, 4 
STEP NO. PROMPT/EXPLANATION pq 
Page 1 of 3 
1. ) DIS SYSTIMER 
2. VARIABLE SYSTEM TIMER=a...a . . . a...a 
Requests timer value(s) to be displayed (10 max.). If more than one, a...a = timer; see Table 506.1. 
separate each by spaces. Enter (CR) to display all. 
1. ) CHA SYSTIMER 
2. VARIABLE SYSTEM TIMER=a...a 
Requests timer for which value...