Page 261

SATURN EPABX A30808-X5051-El20-l-B919 - 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: EXTRN 
TITLE: External Assignments 
Access Level: 2, 3, 4 
I 
EXTRN 
I 
Page 1 of 2 
STEP NO. PROMPT/EXPLANATION 
1. )DIS EXTRN 
NOTE: This action is used to display the numbering plan entries which are routed to another PABX in the Main- 
Satellite network (Main-Satellite systems only). 
2. DISP BY RANGE, TYPE OR TRKGRP? aaaaaa 
Requests how numbering plan entries are to be displayed. If...

Page 262

SATURN EPABX 
CMU Procedures A30808-X5051-E120-l-B919 
Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: EXTRN 
TITLE: External Assignments 
Page 2 of 2 
STEP NO. PROMPT/EXPLANATION 
1. 1 ) DEL EXTRN 
I 
I 
I 
I I 
2. EXTERNAL CODE OR CODE BLK = a . . . a 
Requests external code or code block which is to be deleted. a . . . 
a = external code or code block. 
3. CODE TYPE (STN, ATT, FEAT) = aaaa 
Requests code type which is assigned to external number being 
deleted. aaaa = code type; see Table...

Page 263

SATURN EPABX 
CMU Procedures A30808-X5051-E120-3-8919 
Issue 3, January 1986 
CUSTOMER MEMORY UPDATE PROCEDURE: FEATACC 
TITLE: Feature Access Code Assignments piz-1 
:- 
Access Level: 3, 4 
Page 1 of 4 
STEP NO. PROMPT/EXPLANATION 
1 
1. > DlS FEATACC I 
2. ACCESS CODE OR FEATURE? (A,F)=a 
Requests whether access code or feature data is to be displayed. a = A = access code assignments; 
For list of features assigned to access code range, enter A, then a = F = feature assigned to access 
go to step 3....

Page 264

SATURN EPABX 
CMU Procedures HJJoUU-~~U~~-~~LU-J-OY IY Issue 3, January 1986 
. 
CUSTOMER MEMORY UPDATE PROCEDURE: FEATACC 
tpTLE: Feature Access Code Assignments Page 2 of 4 
STEP NO. PROMPT/EXPLANATION 
8. TENANT GROUP NUMBER (O-254) = nnn 
Requests the user to enter the Group number which the Tenant LDN nnn = Tenant Group Number (O-254) 
Feature is being assigned. 
9. MODEM POOL NUMBER (O-15)=nn 
Requests modem pool number to be assigned to this access code. nn = modem pool number (O-15). 
10. DATA...

Page 265

SATURN EPABX A30808-X5051-E120-3-0919 
CMU Procedures Issue 3, January 1986 
CUSTOMER MEMORY UEDATE PROCEDURE: FEATACC 
TITLE: Feature 
Access Code Assignments 
Page 3 of 4 
Table 420.1 Features (Continued) 
ALPHAMERIC INPUT 
CALLHOLD 
SPLIT 
PARK 
PUDIR 
PUGRP 
TRACE 
CBQCAN 
CASACT 
CASDEACT 
CASATT 
CODEACC 
CODEANS 
CONFRMVLM 
CONFRMVM 
DATAACC 
XCVRTEST 
DICT 
DIRTRK 
SMDRD 
SMDRE 
OVERRIDE 
OVRDENOTN 
EXTATT 
EXTFEAT 
DNDACT 
DNDCAN 
LASTNO 
LCR 
MMCONF 
MSGSET 
MSGCB 
MSGRCVCAN 
MSGSENDCAN...

Page 266

SATURN EPABX A30808X5051-E120-3-5919 
CMU Procedures Issue 3, January 1986 
CIISTDMER MEMORY UPDATE PROCEDURE: 
FEATACC 
. 
1: Feature Access Code Assignments 
ALPHAMERIC 
INPUT 
TSTDOL4 
TSTOPIBTN 
TSTDPlDlS 
TSTMMFSTN 
TSTDIAG 
TSTSTN 
TST-TCNE 
TlMEPROG 
TRKGRP 
ZUNAl 
ZUNA2 
ZUNA3 
ZUNA4 
TMBCR Test Data Device - Loopback 4. 
Test OPI - Button. 
Test DPI - Display. 
Test DTMF Station (Keypad Test). 
Test Maintenance Diagnostics. 
Test Station. 
Test Tone Access. 
. 
Time Programming. ./ 
Trunk Group...

Page 267

SATURN EPABX 
CMU Procedures A30808-X5051-E120-l-B919 
Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: HOTLINE 
TITLE: Hotline Station Assignments 
Access Level: 2, 3, 4 Page 1 of 1 
STEP NO. PROMPT/EXPLANATION 
1. ) DIS HOTLINE 
2. HOT LINE INDEX NUMBER = nn nn 
Requests the hot line index number to be displayed. If range desired, nn = index number(s) (O-31). 
enter two numbers separated by space. 
NOTE: Enter (CR) for all. 
1. ) CHA HOTLINE 
2. HOT LINE INDEX NUMBER = nn 
Requests the hot...

Page 268

SATURN EPABX 
CMU Procedures ’ 
CUSTOMER MEMORY UPDATE PROCEDURE: HUNTGRP 
TITLE: Hunt Group Assignments 
Access Level: 2, 3, 4 A30808-X5051-E120-l-B919 
issue 1, December 1984 
1-1 
Page 1 of 3 
PROMPT/EXPLANATION 
1. ) DIS HUNTGRP 
2. DISP TYPE (ClRC,TERM,PlLOT,MEM) = aaaaa 
Requests type of hunt group for which data is to be displayed. If aaaaa = CIRC, TERM, PILOT, or MEM. 
PILOT, go to step 3; if MEM, go to step 4; if CIRC or TERM, proce- See Table 203.1. 
dure is completed. 
3. PILOT ACCESS NUMBER =...

Page 269

SATURN EPABX 
CMU Procedures A30808-X5051-E120-l-B919 
Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: HUNTGRP 
TITLE: Hunt Group Assignments Page 2 of 3 
I STEP NO. PROMPT/EXPLANATION 
I 
1. > DEL HUNTGRP 
2. DELETE TYPE (PILOT,MEM) = aaaaa 
Requests whether member or pilot number is to be deleted. If MEM, aaaaa = MEM or PILOT 
go to step 3; if PILOT, go to step 4. 
3. MEMBER EXTENSION TO BE DELETED = nnnn 
Requests station number of member to be deleted; procedure is nnnn = ext number...

Page 270

SATURN EPABX A30808-X5051-E120-l-8919 - 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: HUNTGRP 
TITLE: Hunt Group Assignments 
Page 3 of 3 
Table 203.1 Hunt Group Types 
ALPHAMERIC 
INPUT 
CIRC 
MEM 
PILOT 
TERM Circular Hunt Group 
Hunt Group Member 
Pilot Number Hunt Group 
Terminal Hunt Group DESCRIPTION  