Page 251

SATURN EPABX A30808-X5051-E120-l-8919 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DPICHGE :. 
TITLE: DPI Assignments (Change) ,/ !  
Access Level: 2, 3, 4 Page 2 of 5 
STEP NO. PROMPT/EXPLANATION 
9. BUTTON TYPE TO ADD = aaaaaaaa 
Requests button type to add to this DPI map. aaaaaaaa = button type (select one from 
Enter one type: list below). 
DICT - go to step 10. 
DSS - go to step 11. 
VCDSS - go to step 14. 
TGTERM - go to step 16. 
TGORIG - go to step 19. 
AUTOICOM - go...

Page 252

SATURN EPABX A30808-X5051-E120-l-B919 - 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DPICHGE 
TITLE: DPI Assignments (Change) 
Page 3 of 5 
STEP NO. PROMPT/EXPLANATION 
17. TRK GRP (TERM) GROUP NUMBER(S) = nn nn 
.Requests trunk group number(s) to be assigned to the button(s) as- nn = trunk group(s) (O-31). 
signed above. If more than one, separate each by spaces. 
18. TRK GRP RING ON INCOMING? (Y,N) = a a 
Requests whether incoming calls on trunk group line(s) above are a =...

Page 253

SATURN EPABX A30808-X5051-E120-l-B919 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DPICHGE 
TITLE: DPI Assignments (Change) 
STEP NO. PROMPT/EXPLANATION Page 4 of 5 
27. MANUAL ICOM GROUP NUM(S) (O-15) = nn nn 
Requests manual intercom group number(s) to be assigned to the nn = intercom group(s) (O-15). 
corresponding button(s) in the preceding step. If more than two as- 
signed, separate each by space. Procedure is completed. 
28. 1 LINE EXTENSION BUTTON NUMBER(S) = nn . . ....

Page 254

SATURN EPABX A30808-X5051-E120-l-B919 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DPICHGE 
‘% 
TITLE: DPI Assignments (Change) 
Page 5 of 5 
I-- STEP NO. PROMPT/EXPLANATION 
I 
37. 
r-~~- TRUNK RING INCOMING? (Y,N) = a . . . a 
I 
Requests whether trunk is to ring set on incoming button(s) assigned a = Y = Yes, a = N = No. 
above. If more than one, separate each by spaces. Procedure is 
complete. 
38. VOICE CALL BUTTON NUMBER (l-26) = nn 
Requests line button to be assigned...

Page 255

SATURN EPABX A30808-X5051-E120-l-6919 - 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DPlDlSP 
TITLE: DPI Assignments (Display) 
Access Level: 1, 2, 3, 4 
STEP NO. PROMPT/EXPLANATION Page 1 of 1 
1. 
2. ) DIS DPIDISP 
STATION EXTENSION NUMBER (DPI) = nnnn . . . nnnn 
Requests extension number of DPI for which data is to be displayed. 
If two numbers are entered, data is displayed for the range of DPls 
between those numbers, inclusive. (Separate range of DPls by 
spaces)....

Page 256

SATURN EPABX 
CMU Procedures . ..---u . . . ..a - -. Issue 4, November l&5 
CUSTOMER MEMORY UPDATE PROCEDURE: QPIMAP 
TITLE: DPI Button Maps 
Access Level: 2, 3, 4 Page 1 of 2 
STEP NO. PROMPT/EXPLANATION 
I 
1. 
2. ) DIS DPIMAP 
DPI BUTTON MAP NUMBER (1-32) = nn . . . nn 
Requests button map number(s) for which data is to be displayed. 
nn = button map(s) (l-32). 
If more than one, separate each by spaces. Enter (CR) to display 
all button maps starting with button map 0. 
NOTE: Button Map 0 is the...

Page 257

SATURN EPABX 
CMU Procedures A30808-X5051-E120-4.8919 
Issue 4, November 1985 
:- DPI Button Maps 
. . CUSTOMER MEMORY UPDATE PROCEDURE: DPIMAP 
Page 2 of 2 
Table 215.1 DPI Button Features (Continued) 
ALPHAMERIC 
INPUT DESCRlPTlbN 
FWDFORCE 
HANDSFREE 
MUTE 
IUSE 
LASTNO 
HOLD 
BUZZ 
MEETME 
MSGSET 
MSGCALLBK 
MSGCANCEL 
ONHKDIAL 
PAT-T 
PRIV 
TALK 
RLS 
SAVENO 
SETALARM 
SPEEDGRPI 
SPEEDGRP2 
SPEEDGRP3 
SPEEDGRP4 
SPEEDIND 
STNDEF 
STNDEFDD 
TIME 
RINGEROFF 
XFER 
VOICEANN 
VOICEREJ 
WRAPUP 
ZUNAl...

Page 258

SATURN EPABX 
CMU Procedures A30808-X5051-E120-l-B919 - 
Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DTMFASSN 
TITLE: DTMF Receiver Assignments 
Access Level: 3, 4 
STEP NO. PROMPT/EXPLANATION 
1. > DIS DTMFASSN 
1. > ADD DTMFASSN 
2. PORT EQUIPMENT NUMBER (WXYZ)= nnnn 
Requests PEN of DTMF receiver to be added. nnnn = valid PEN. Page 1 of 1 
1. 
> DEL DTMFASSN 
2. 
PORT EQUIPMENT NUMBER (WXYZ) = nnnn 
Requests PEN of DTMF receiver to be deleted. nnnn = valid PEN. 
NOTE: The DTMF receiver...

Page 259

SATURN EPABX 
CMU Procedures A30808-X5051-E120-l-B919 - 
Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DUPLEX 
TITLE: Duplex Processor Assignments 
Access Level: 4 
STEP NO. PROMPT/EXPLANATION Page 1 of 2 
1. 
2. 
3. 
4. 
5. 
6. ) DIS DUPLEX 
1 
NOTE: This procedure is provided for use on duplex (Hot Standby) systems only. 
DISPLAY TYPE = aaaaaa 
Requests the type of duplex data which is to be displayed. aaaaaa = display type: STATUS, 
ALMDATA or TRACE. 
NOTE: Enter ALMDATA to display alarms...

Page 260

SATURN EPABX A30808-X5051-E120-l-6919 
CMU Procedures Issue 1, December 1984 
CUSTOMER MEMORY UPDATE PROCEDURE: DUPLEX 
TITLE: Duplex Processor Assignments 
Access Level: 4 
STEP NO. PROMPT/EXPLANATION Page 2 of 2 
4. TRACE STATE (ON/OFF/RESET) = aaaaa 
Requests whether the trace routine is to be turned on or off, or reset. aaaaa = ON, OFF, or RESET. 
If trace is turned on, the trace buffer is cleared and the trace begins 
based on the following data. If the trace is turned off, the trace buffer 
is not...