    							MX-2300/2700 N/G  SIMULATION  7 – 95
    
    A to H: 1step=0.1mm
    C to H: When the adjustment value is increased, the image loss is
    increased.
    * It is linked with items C to H of SIM50-6.
    
    SIDE1 adjustment value: 
    SIDE2 adjustment value: 
    *
    1: Correction value = (Measurement reference 10mm – 
    Lead edge image loss set value) x 10 x (Magnification ratio/
    100)
    Example of calculation: 140 = (100 – 30) x 10 x (200%/100)
    *
    2: 2 = (Magnification ratio 200%/100)
    If L4 = 0, do not make calculation of SIDE1, but adjust the value of
    L5.
    If L5 = 0, do not make calculation of SIDE2, but adjust the value of
    L4.
    If L4 = L5 = 0, the adjustment values of SIDE1 and SIDE2 are the
    default values.
     
    50-10
    Purpose: Adjustment
    Function (Purpose): Used to adjust the print off-center for each
    tray.
    Image print center position adjustment
    (Adjusted for each paper feed section.)
    Section:–
    Item: Image quality (Image position)
    Operation/Procedure
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted section of the set value is switched and dis-
    played on the set setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    2) Enter the set value with 10-key.
    * When [C] key is pressed, the entered value is cleared.
    3) When [EXECUTE] button is pressed, it is highlighted and print-
    ing for adjustment is started with the current set value.
    After completion of printing, [EXECUTE] button returns to the
    normal display.
    * When [↑], [↓], [OK] button, [COLOR], or [BLACK] key is pressed,
    the data are saved to EEPROM and RAM.
    * When [C], [CA], [SYSTEM SETTINGS], or [EXECUTE] button is
    pressed during printing, the operation is interrupted.
    * When the machine returns to the ready state after occurrence of
    an interruption, self printing is resumed.
    
    Item Display item Description of itemSet 
    rangeDefault 
    value
    A L4 Distance from the front 
    surface image lead edge to 
    the scale of 10mm (SPF 
    200%, unit 0.1mm)0 to 999 —
    B L5 Distance from the back 
    surface image lead edge to 
    the scale of 10mm (SPF 
    200%, unit 0.1mm)0 to 999 —
    C LEAD_EDGE 
    (SIDE1)Image loss quantity setting 
    SIDE10 to 99 20
    D FRONT_REAR 
    (SIDE1)0 to 99 20
    E TRAIL_EDGE 
    (SIDE1)0 to 99 30
    F LEAD_EDGE 
    (SIDE2)Image loss quantity setting 
    SIDE20 to 99 20
    G FRONT_REAR
    (SIDE2)0 to 99 20
    H TRAIL_EDGE 
    (SIDE2)0 to 99 30
    L4-Correction value*1
    2*2Old set value-()
    L5-Correction value *1
    2*2Old set value +()
    1
    1
    0
    C:
    A0
    B0C20
    D20
    L4L5LEAD_EDGE(SIDE1)FRONT_REAR(SIDE1)
    SIMULATION NO.50-07
    LEAD EDGE ADJUSTMENT (SPF CALC.).
    20
    0999
    TESTCLOSE
    EXECUTE
    Item Display item & Detail of display Item content Set range Default value Writing
    A BK-MAG Main scan print magnification ratio BK 60 to 140 100 YES
    B MFT Print off-center adjustment value (manual feed) 1 to 99 50 YES
    C CS1 Print off-center adjustment value (Cassette 1) 1 to 99 50 YES
    D CS2 Print off-center adjustment value (Cassette 2) 1 to 99 50 YES
    E CS3 Print off-center adjustment value (Cassette 3) 1 to 99 50 YES
    F CS4 Print off-center adjustment value (Cassette 4) 1 to 99 50 YES
    G LCC Print off-center adjustment value (LCC) 1 to 99 50 YES
    H ADU Print off-center adjustment value (ADU) 1 to 99 50 YES
    I MULTI COUNT Print quantity 1 to 999 1 NO
    J PAPER MFT Cassette select Manual feed 1 to 6 1 2 (CS1) NO
    CS1 Cassette 1 2
    CS2 Cassette 2 3
    CS3 Cassette 3 4
    CS4 Cassette 4 5
    LCC LCC 6
    K DUPLEX YES Duplex print select Selected 0 to 1 0 1 (NO) NO
    NO Not selected 1
    : Dec. 15 20051 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 96 * Item A adjustment position
    The main scanning direction paper size is greater than 216mm:
    → Reference: Main scanning direction print front image center
    position (160mm from the BD sensor in the LSU unit) ±120mm in
    the main scanning direction
    The main scanning direction paper size is 257mm or less:
    Reference: Main scanning direction print front image center posi-
    tion (160mm from the BD sensor in the LSU unit) ±60mm in the
    main scanning direction
    * Adjustment direction
    + direction: Enlargement of magnification ratio
    - direction: Reduction of magnification ratio
    * When the adjustment value of item B to H is decreased by 1, the
    main scanning print position is shifted to the front side by 0.1mm.
    * When the adjustment value of item B to H is increased by 1, the
    main scanning print position is shifted to the rear side by 0.1mm.
    * Items J and K are displayed as Display item: Detail of display.
    Example: PAPER:CS1
     
    50-12
    Purpose: Adjustment
    Function (Purpose): Used to execute the scan image off-center
    position adjustment. (Adjusted for each
    scan mode.)
    Section:
    Item: Image quality (Image position)
    Operation/Procedure
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted section of the set value is switched and dis-
    played on the set setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    2) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    3) When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is
    pressed, the currently entered data are saved to EEPROM and
    RAM.
    * When [CLOSE] button is pressed, the display is shifted to the
    copy basic screen of simulation.
    * Copying can be performed also by pressing [COLOR]/[BLACK]
    key.
    Shift the pixel center position. The default value of the center is
    3750 pixels.
    A to C: When the adjustment value is increased, the center position
    is shifted to the rear side. 1step=0.1mm
     
    50-20
    Purpose: Adjustment
    Function (Purpose): Used to execute the manual adjustment of
    the main scanning direction registration
    (color shift). (Backup value input)
    Section:
    Item: Image quality
    Operation/Procedure
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted section of the set value is switched and dis-
    played on the set setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    2) Enter the set value with 10-key.
    * When [C] key is pressed, the entered value is cleared.
    3) When [EXECUTE] button is pressed, it is highlighted and the
    currently entered data are saved to EEPROM and RAM. Then
    the main scanning direction registration adjustment pattern is
    printed.
    After completion of printing, [EXECUTE] button returns to the
    normal display.
    4) When [↑], [↓], [OK], [EXECUTE] button, [COLOR], or [BLACK]
    key is pressed, the data are saved to EEPROM and RAM.
    * When [C], [CA], [SYSTEM SETTINGS], or [EXECUTE] but-
    ton is pressed during printing, the operation is interrupted.
    * When the machine returns to the ready state after occur-
    rence of an interruption, self printing is resumed.
    Item Display item Set rangeSet 
    valueDefault 
    value
    A OC OC document off-center 
    adjustment1 to 99 50
    B SPF (SIDE1) SPF front surface off-center 
    adjustment1 to 99 50
    C SPF (SIDE2) SPF back surface off-center 
    adjustment1 to 99 50
    0
    A:A9æ100
    B9æ509çBK-MAG
    9çMFT
    SIMULATIONNO.509Ù10
    PAPER CENTER OFFSET SETUP
    100
    :60:*140:	
    OK
    TEST
    EXECUTE
    CLOSE
    C9æ509çCS1
    D9æ509çCS2
    0
    A:
    A9æ50
    B9æ509çOC
    9çSPF(SIDE1)
    SIMULATIONNO.509Ù12
    ORIGINAL CENTER OFFSET SETUP
    50
    :1:*99:	
    OK
    TESTCLOSE
    C9æ509çSPF(SIDE2) 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 97 
    * Items H and I are displayed as Display item: Detail of display.
    Example: PAPER:CS1
     
    50-21
    Purpose: Adjustment
    Function (Purpose): Used to execute the manual adjustment of
    the sub scanning registration (color shift).
    (Backup value input)
    Section:—
    Item: Image quality
    Operation/Procedure
    1) Select the set item with [↑] and [↓] buttons.
    The highlighted section of the set value is switched and dis-
    played on the set setting area.* If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    2) Enter the set value with 10-key.
    * When [C] key is pressed, the entered value is cleared.
    3) When [EXECUTE] button is pressed, it is highlighted and the
    currently entered data are saved to EEPROM and RAM. Then
    the main scanning direction registration adjustment pattern is
    printed.
    After completion of printing, [EXECUTE] button returns to the
    normal display.
    * When [↑], [↓], [OK], [EXECUTE] button, [COLOR], or
    [BLACK] key is pressed, the data are saved to EEPROM
    and RAM.
    * When [C], [CA], [SYSTEM SETTINGS], or [EXECUTE] button is
    pressed during printing, the operation is interrupted.
    * When the machine returns to the ready state after occurrence of
    an interruption, self printing is resumed.
    
    * Items E and F are displayed as Display item : Detail of display.
    Example: PAPER:CS1
    Item Display item & Detail of display Description of item Set range Default value Writing
    A CYAN (FRONT) Registration adjustment value main scanning direction 
    (Cyan laser writing position F side)1 to 199 100 YES
    B CYAN (REAR) Registration adjustment value main scanning direction 
    (Cyan laser writing position R side)1 to 199 100 YES
    C MAGENTA (FRONT) Registration adjustment value main scanning direction 
    (Magenta laser writing position F side)1 to 199 100 YES
    D MAGENTA (REAR) Registration adjustment value main scanning direction 
    (Magenta laser writing position R side)1 to 199 100 YES
    E YELLOW (FRONT) Registration adjustment value main scanning direction 
    (Yellow laser writing position F side)1 to 199 100 YES
    F YELLOW (REAR) Registration adjustment value main scanning direction 
    (Yellow laser writing position R side)1 to 199 100 YES
    G MULTICOUNT Print quantity 1 to 999 1 NO
    H PAPER MFT Cassette select Manual feed 1 to 6 1 3 (CS2) NO
    CS1 Cassette 1 2
    CS2 Cassette 2 3
    CS3 Cassette 3 4
    CS4 Cassette 4 5
    LCC LCC 6
    I DUPLEX YES Duplex print select Selected 0 to 1 0 1 (NO) NO
    NO Not selected 1
    0
    A:
    A9æ100
    B9æ1009çCYAN(FRONT)
    9çCYAN(REAR)
    SIMULATIONNO.509Ù20
    REGISTRATIONADJUSTMENT : FRONT-REAR DIRECTION
    100
    :1:*199:	
    OK
    TEST
    EXECUTE
    CLOSE
    C9æ1009çMAGENTA(FRONT)
    D9æ1009çMAGENTA(REAR)
    Item Display item & Detail of display Description Set value Default value Writing
    A CYAN Registration adjustment value sub scanning direction 
    (Cyan drum → Black drum)1 to 199 100 YES
    B MAGENTA Registration adjustment value sub scanning direction 
    (Magenta drum → Black drum)1 to 199 100 YES
    C YELLOW Registration adjustment value sub scanning direction 
    (Yellow drum → Black drum)1 to 199 100 YES
    D MULTICOUNT Print quantity 1 to 999 1 NO
    E PAPER MFT Cassette select Manual feed 1  to 6 1 2 (CS1) NO
    CS1 Cassette 1 2
    CS2 Cassette 2 3
    CS3 Cassette 3 4
    CS4 Cassette 4 5
    LCC LCC 6
    F DUPLEX YES Duplex print select Selected 0  to 1 0 1 (NO) NO
    NO Not selected 1 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 98
     
    50-22
    Purpose: Adjustment
    Function (Purpose): Used to execute the auto adjustment of the
    main/sub scan the main/sub registration.
    (Print on the belt/ Scan with the registration
    sensor (photo sensor)
    Image registration adjustment (Auto adjust-
    ment) adjustment image quality image posi-
    tion
    Section:–
    Item: Image qualityOperation/Procedure
    1) Select the mode. (In this example, [REGIST] is selected.)
    * Press the button to select a category. The selected button is
    highlighted. The set item of the selected button is displayed.
    * Only one button can be selected. The selected button is
    highlighted. In the initial state, [ALL] button is selected.
    * If there is a page over [↑], an active display is shown and the
    page moves up. If there is no page upward, the display
    grays out and the operation is invalid.
    If there is a page under [↓], an active display is shown and
    the page moves down. If there is no page downward, the
    display grays out and the operation is invalid.
    2) When [EXECUTE] button is pressed, it is highlighted and all
    the drum motors are driven to start the adjustment.
    * After completion of the adjustment, the drum motor is
    stopped and [EXECUTE] button returns to the normal dis-
    play. The adjustment result is displayed.
    MAIN, SUB:
    After the adjustment, the adjustment value is displayed.
    ( ) Difference from the previous value.
    Example: This time 105, previous time 103: 105 (+2)
    PHASE:
    The number assigned to the phase is displayed.
    ( ) Difference from the previous value.
    
    
    0
    A:
    A9æ100
    B9æ1009çCYAN
    9çMAGENTA
    SIMULATIONNO.509Ù21
    REGISTRATIONADJUSTMENT : SCANNING DIRECTION
    100
    :1:*199:	
    OK
    TEST
    EXECUTE
    CLOSE
    C9æ1009çYELLOW
    D9æ19çMULTICOUNT
    Button Display Content DisplayDefault 
    valueRemark
    ALL (All 
    execution (Both 
    of the auto 
    registration 
    adjustment and 
    the auto phase 
    adjustment are 
    executed.)REGIST (Auto 
    registration 
    adjustment is 
    executed.)MAIN F C Registration adjustment value main scan 
    direction (Cyan laser writing position F side)1.0 – 
    199.0100.0 Same item with SIM50-20 
    *
    However, the adjustment 
    accuracy is in the unit of 
    ±0.1 dot. (The adjustment 
    accuracy of 50-20, -21 is 
    in the unit of ±1.0dot.) M Registration adjustment value main scan 
    direction (Magenta laser writing position F 
    side)1.0 – 
    199.0100.0
    Y Registration adjustment value main scan 
    direction (Yellow laser writing position F side)1.0 – 
    199.0100.0
    MAIN R C Registration adjustment value main scan 
    direction (Cyan laser writing position R side)1.0 – 
    199.0100.0
    M Registration adjustment value main scan 
    direction (Magenta laser writing position R 
    side)1.0 – 
    199.0100.0
    Y Registration adjustment value main scan 
    direction (Yellow laser writing position R side)1.0 – 
    199.0100.0
    SUB C Registration adjustment value sub scan 
    direction (Cyan drum → Black drum)1.0 – 
    199.0100.0
    M Registration adjustment value sub scan 
    direction (Magenta drum → Cyan drum)1.0 – 
    199.0100.0
    Y Registration adjustment value sub scan 
    direction (Yellow drum → Magenta drum)1.0 – 
    199.0100.0
    DLUM POS 
    (Auto phase 
    adjustment is 
    executed.)PHASE Phase adjustment 
    value BK → CLAngle step 1 – 8 2 Same item with SIM 44-31
    0° (1) → 45° (2) → 90° (3) → 135° 
    (4) → 180° (5) → 225° (6) → 270° 
    (7) → 315°(8)
    Error 
    codeError display Error content Detail of content
    Compulsory 
    end error- SUSPENDED Door open end Door open during operation
    - SUSPENDED CA end Pressing [CA] button during operation
    - - OFF end Unconfirmed operation (power OFF) during operation
    Basic error 1 TONER EMPTY Toner empty BK or all colors toner empty detection
    2 TONER BEFORE 
    BEHAVIOROther conditions Other conditions
    4 SENSOR CALIBRATION Calibration error With 3 times of retry of F or R, the target is not reached. 
    5 TIME OVER Time error Data is not acquired for 90sec from data acquisition
    7 PROCESS CONTROL Process control error Process control error detection  
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 99
    Sub scan 
    adjustment 
    error10 MAIN BLACK FRONT Number error sub scan BLACK F The number of pitch data is not the specified number. 
    11 MAIN BLACK FRONT Pitch error sub scan BLACK F The pitch data is not in the specified allowable range. 
    15 SUB BLACK REAR Number error sub scan BLACK R The number of pitch data is not in the specified range. 
    16 SUB BLACK REAR Pitch error sub scan BLACK R The pitch data is not in the specified allowable range. 
    20 SUB CYAN FRONT Number error sub scan CYAN F The number of pitch data is not the specified number. 
    21 SUB CYAN FRONT Pitch error sub scan CYAN F The pitch data is not in the specified allowable range. 
    22 SUB CYAN FRONT Adjustment value error sub scan 
    CYAN FThe calculation result value is not in the specified allowable 
    range. 
    23 SUB CYAN FRONT Result value error sub scan CYAN F The variation of the calculation result value is over the 
    specified allowable range. 
    25 SUB CYAN REAR Number error sub scan CYAN R The number of pitch data is not the specified number. 
    26 SUB CYAN REAR Pitch error sub scan CYAN R The pitch data is not in the specified allowable range. 
    27 SUB CYAN REAR Adjustment value error sub scan 
    CYAN RThe calculation result value is not in the specified allowable 
    range. 
    28 SUB CYAN REAR Result value error sub scan CYAN 
    RThe variation of the calculation result value is over the 
    specified allowable range. 
    30 SUB MAGENTA FRONT Number error sub scan MAGENTA 
    FThe number of pitch data is not the specified number. 
    31 SUB MAGENTA FRONT Pitch error sub scan MAGENTA F The pitch data is not in the specified allowable range. 
    32 SUB MAGENTA FRONT Adjustment value error sub scan 
    MAGENTA FThe calculation result value is not in the specified allowable 
    range. 
    33 SUB MAGENTA FRONT Result value error sub scan 
    MAGENTA FThe variation of the calculation result value is over the 
    specified allowable range. 
    35 SUB MAGENTA REAR Number error sub scan MAGENTA 
    RThe number of pitch data is not the specified number. 
    36 SUB MAGENTA REAR Pitch error sub scan MAGENTA R The pitch data is not in the specified allowable range. 
    37 SUB MAGENTA REAR Adjustment value error sub scan 
    MAGENTA RThe calculation result value is not in the specified allowable 
    range. 
    38 SUB MAGENTA REAR Result value error sub scan 
    MAGENTA RThe variation of the calculation result value is over the 
    specified allowable range. 
    40 SUB YELLOW FRONT Number error sub scan YELLOW F The number of pitch data is not the specified number. 
    41 SUB YELLOW FRONT Pitch error sub scan YELLOW F The pitch data is not in the specified allowable range. 
    42 SUB YELLOW FRONT Adjustment value error sub scan 
    YELLOW FThe calculation result value is not in the specified allowable 
    range. 
    43 SUB YELLOW FRONT Result value error sub scan 
    YELLOW FThe variation of the calculation result value is over the 
    specified allowable range. 
    45 SUB YELLOW REAR Number error sub scan YELLOW R The number of pitch data is not the specified number. 
    46 SUB YELLOW REAR Pitch error sub scan YELLOW R The pitch data is not in the specified allowable range. 
    47 SUB YELLOW REAR Adjustment value error sub scan 
    YELLOW RThe calculation result value is not in the specified allowable 
    range. 
    48 SUB YELLOW REAR Result value error sub scan 
    YELLOW RThe variation of the calculation result value is over the 
    specified allowable range. 
    Main scan 
    adjustment 
    error50 MAIN BLACK FRONT Number error main scan BLACK F The number of pitch data is not the specified number. 
    51 MAIN BLACK FRONT Pitch error main scan BLACK F The pitch data is not in the specified allowable range. 
    55 MAIN BLACK REAR Number error main scan BLACK R The number of pitch data is not in the specified range. 
    56 MAIN BLACK REAR Pitch error main scan BLACK R The pitch data is not in the specified allowable range. 
    60 MAIN CYAN FRONT
    Number error main scan CYAN The number of pitch data is not the specified number. 
    61 MAIN CYAN FRONT
    Pitch error main scan CYAN The pitch data is not in the specified allowable range. 
    62 MAIN CYAN FRONT Adjustment value error main scan 
    CYAN FThe calculation result value is not in the specified allowable 
    range. 
    63 MAIN  CYAN  FRONT Result value error main scan CYAN  
    FThe variation of the calculation result value is over the 
    specified allowable range. 
    65 MAIN CYAN REAR Number error main scan CYAN R The number of pitch data is not the specified number. 
    66 MAIN CYAN REAR Pitch error main scan CYAN R The pitch data is not in the specified allowable range. 
    67 MAIN CYAN REAR Adjustment value error main scan 
    CYAN RThe calculation result value is not in the specified allowable 
    range. 
    68 MAIN CYAN REAR Result value error main scan CYAN 
    RThe variation of the calculation result value is over the 
    specified allowable range. 
    70 MAIN  MAGENTA  FRONT Number error main scan MAGENTA 
    FThe number of pitch data is not the specified number. 
    71 MAIN MAGENTA FRONT Pitch error main scan MAGENTA F The pitch data is not in the specified allowable range. 
    72 MAIN MAGENTA FRONT Adjustment value error main scan 
    MAGENTA FThe calculation result value is not in the specified allowable 
    range.  Error 
    codeError display Error content Detail of content1
    : Dec. 15 20051 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 100 (Initial screen or when in normal end)
    (Adjustment screen)
    (Error end screen)
     
    50-24
    Purpose: Adjustment
    Function (Purpose): Used to display the data acquired with the
    auto registration adjustment simulation
    (SIM50-22).
    Section:—
    Item: Image quality
    Operation/Procedure
    1) When the machine enters Simulation 50-24, the following
    screen is displayed.* Select the kind of display with [NEXT] and [BACK] buttons.
    * Specify the color with [K], [C], [M], and [Y] buttons. (Depend-
    ing on the selected kind of data, selection of a color button
    cannot be made. In that case, the key entry is disabled.)
    * If there is a page over [↑], an active display is shown and the
    page moves up. If there is no page upward, the display
    grays out and the operation is invalid.
    If there is a page under [↓], an active display is shown and
    the page moves down. If there is no page downward, the
    display grays out and the operation is invalid.
    * When [CLOSE] button is pressed, the display is shifted to the
    copy basic screen of simulation.
    * Copying can be performed also by pressing [COLOR]/[BLACK]
    key.
    
    1) Registration adjustment confirmation screen
    Use [K][C][M][Y] button to display the initial screen (No color
    specified/C/M/Y).
    Press [NEXT] button to display the next category.
    Press [BLACK] button to display the previous category.
    2) Phase adjustment status check screen
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    3) Sensor calibration status check (No color specification)
    Press [K] button to display the initial screen of K. 
    Press [NEXT] button to display the category.
    Press [BACK] button to display the previous category.
    4) Sampling status check (1) (KCMY/No color specification)
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    5) Sampling status check (2) (KCMY)
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    Main scan 
    adjustment 
    error73 MAIN MAGENTA FRONT Result value error main scan 
    MAGENTA FThe variation of the calculation result value is over the 
    specified allowable range. 
    75 MAIN  MAGENTA  REAR Number error main scan MAGENTA 
    RThe number of pitch data is not the specified number. 
    76 MAIN MAGENTA REAR Pitch error main scan MAGENTA R The pitch data is not in the specified allowable range.
    77 MAIN MAGENTA REAR Adjustment value error main scan 
    MAGENTA RThe calculation result value is not in the specified allowable 
    range. 
    78 MAIN MAGENTA REAR Result value error main scan 
    MAGENTA RThe variation of the calculation result value is over the 
    specified allowable range. 
    80 MAIN YELLOW FRONT Number error main scan YELLOW 
    FThe number of pitch data is not the specified number. 
    81 MAIN YELLOW FRONT Pitch error main scan YELLOW F The pitch data is not in the specified allowable range. 
    82 MAIN YELLOW FRONT Adjustment value error main scan 
    YELLOW FThe calculation result value is not in the specified allowable 
    range. 
    83 MAIN YELLOW FRONT Result value error main scan 
    YELLOW FThe variation of the calculation result value is over the 
    specified allowable range. 
    85 MAIN YELLOW REAR Number error main scan YELLOW 
    RThe number of pitch data is not the specified number. 
    86 MAIN YELLOW REAR Pitch error main scan YELLOW R The pitch data is not in the specified allowable range. 
    87 MAIN YELLOW REAR Adjustment value error main scan 
    YELLOW RThe calculation result value is not in the specified allowable 
    range. 
    88 MAIN YELLOW REAR Result value error main scan 
    YELLOW RThe variation of the calculation result value is over the 
    specified allowable range. 
    Other error 99 OTHER Other error Other errorError 
    codeError display Error content Detail of content
    0SIMULATIONNO.50-22TESTAUTO ADJUSTMENT OF REGISTRATION&DLUM POSITION
    EXECUTE
    MAIN F MAIN R SUB PHASE
    C 105.0 (+0.2) 110.0 (-0.1) 103.0 (+0.4) 4 (3)
    M 100.0 (+0.0) 99.0 (-0.2) 99.0 (+0.2)
    Y 98.0 (+0.3) 98.0 (+0.1) 105.0 (+0.0)
    1/1
    CLOSE
    REGISTDRUM POSALL
    0SIMULATION NO.50-22TESTAUTO ADJUSTMENT OF REGISTRATION&DLUM POSITION
    CLOSE
    EXECUTE
    NOW EXECUTING…
    0SIMULATION NO.50-22TESTAUTO ADJUSTMENT OF REGISTRATION&DLUM POSITION
    CLOSE
    EXECUTE
    PRESS [EXECUTE] TO START
    ERROR : TONNER EMPTY 01 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 101 6) Sampling status check (3) (KCMY)
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    7) Sampling status check (4) (KCMY)
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to  display the previous category.
    8) Sampling status check (5) (KCMY)
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to  display the previous category.
    9) Sampling status check (6) (KCMY)
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    10) Sampling status check (7) (KCMY)
    Press [K][C][M][Y] button to display the initial screen (K/C/M/
    Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    11) Temperature correction value check screen (CMY)
    Press [C][M][Y] button to display the initial screen (C/M/Y).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    12) Temperature correction value check screen (No color specifi-
    cation)
    Press [K] button to display the initial screen (K).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.
    13) Error code status check (No color specification)
    Press [K] button to display the initial screen (K).
    Press [NEXT] button to display the next category.
    Press [BACK] button to display the previous category.Initial screen (Registration adjustment status check screen (No
    color specification))
     
    50-27
    Purpose: Adjustment
    Function (Purpose): Used to adjust the image loss of scanned
    image in the FAX/Scanner mode.
    Section: FAX/Scanner
    Item: Image quality
    Operation/Procedure
    1) Use [FAX] button and [SCANNER] button to select the mode.
    2) Select the set item with [↑] and [↓] buttons.
    The highlighted section of the set value is switched and dis-
    played on the set setting area.
    * If there is any item over [↑], an active display is made and
    item is shifted.
    If there is no item over [↑], the display grays out and the
    operation is invalid.
    If there is any item under [↓], an active display is made and
    item is shifted.
    If there is no item over [↓], the display grays out and the
    operation is invalid.
    3) Enter the set value with 10-key.
    * Press [C] key to clear the entered values.
    4) When [OK] button is pressed, the current entered value is
    saved to EEPROM and RAM.
    * When [↑], [↓] button, [COLOR], or [BLACK] key is pressed,
    the data are saved to EEPROM and RAM.
    * When [CLOSE] button is pressed, the display is shifted to the
    copy basic screen of simulation.
    
    * A to I: The greater the adjustment value is, the greater the image loss is. 1step=0.1mm
    KCMYNEXT
    SIMULATIONNO. 50-24TESTAUTO REGISTRATION DATA DISPLAY
    REG_EXE_CNT00000000
    REG_SUC_CNT00000000
    00000000
    REG_CNT
    1/1
    0
    CLOSE
    BACK
    Item Display item Description Set range Default value
    FAX send A Image loss 
    setting OCLEAD_EDGE (OC) OC lead edge image loss setting 0 to 100 30 (3mm)
    B FRONT_REAR (OC) OC side image loss setting 0 to 100 20 (2mm)
    C TRAIL_EDGE (OC) OC rear edge image loss setting 0 to 100 20 (2mm)
    DImage loss 
    setting SPF 
    SIDE1LEAD_EDGE (SPF_SIDE1) Front surface lead edge image loss setting  0 to 100 20 (2mm)
    E FRONT_REAR (SPF_SIDE1) Front surface side image loss setting  0 to 100 20 (2mm)
    F TRAIL_EDGE (SPF_SIDE1) Front surface rear edge image loss setting  0 to 100 30 (3mm)
    GImage loss 
    setting SPF 
    SIDE2LEAD_EDGE (SPF_SIDE2) Back surface lead edge image loss setting  0 to 100 20 (2mm)
    H FRONT_REAR (SPF_SIDE2) Back surface side image loss setting  0 to 100 20 (2mm)
    I TRAIL_EDGE (SPF_SIDE2) Back surface rear edge image loss setting  0 to 100 30 (3mm)
    SCANNER 
    mode (FAX, 
    other than 
    COPY)AImage loss 
    setting OCLEAD_EDGE(OC) OC lead edge image loss setting 0 to 100 0 (0mm)
    B FRONT_REAR(OC) OC side image loss setting 0 to 100 0 (0mm)
    C TRAIL_EDGE(OC) OC rear edge image loss setting 0 to 100 0 (0mm)
    DImage loss 
    setting SPF 
    SIDE1LEAD_EDGE(SPF_SIDE1) Front surface lead edge image loss setting  0 to 100 0 (0mm)
    E FRONT_REAR(SPF_SIDE1) Front surface side image loss setting  0 to 100 0 (0mm)
    F TRAIL_EDGE(SPF_SIDE1) Front surface rear edge image loss setting  0 to 100 0 (0mm)
    GImage loss 
    setting 
    SPFSIDE2LEAD_EDGE(SPF_SIDE2) Back surface lead edge image loss setting  0 to 100 0 (0mm)
    H FRONT_REAR(SPF_SIDE2) Back surface side image loss setting  0 to 100 0 (0mm)
    I TRAIL_EDGE(SPF_SIDE2) Back surface rear edge image loss setting  0 to 100 0 (0mm) 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 102
     
    50-28
    Purpose: Adjustment
    Function (Purpose): Used to execute the service adjustment,
    the OC adjustment, the BK main scan mag-
    nification ration correction, the RSPF
    adjustment, and the print position adjust-
    ment (Auto void adjustment (Service instal-
    lation adjustment)).
    Section:—
    Item: Image quality
    Operation/Procedure
    1) When the machine enters Simulation 50-28, the following
    screen is displayed.
    2) Press the button of an item to be adjusted, and the display is
    shifted to the adjustment screen.
    * The operating procedures and the display shift for each adjust-
    ment and the display, refer to the next page.
    
     
     
    50-28
    Purpose: Adjustment
    Function (Purpose): Used to adjust the OC document lead
    edge, off-center, and the sub scan magnifi-
    cation ratio. (Auto void adjustment (Service
    installation adjustment) (1: OC adjustment))
    Section:—
    Item: Image quality
    Operation/Procedure
    1) When [OC ADJ] button is pressed on the top menu screen, the
    screen shown on the right side is displayed.
    2) Select a cassette of self print of the OC adjustment pattern.
    (Only one cassette can be selected.)
    3) Press [EXECUTE] button to start self print of the OC adjust-
    ment pattern.
    * During self printing of the OC adjustment
    After completion of self print, the display is shifted to the OC
    adjustment start screen.
    4) Set the OC adjustment pattern on the OC with the corner refer-
    ence, and cover the black background chart over the OC
    adjustment pattern.
    * Set the adjustment pattern in traversal position (A4). Check
    to confirm that there is no clearance with the document
    guide.
    * Kind and size of black background charts made with a cut-
    ting sheet equivalent to 310 x 470 cutting sheet No. 791
    (Black).
    5) Press [EXECUTE] button to start scanning of the OC adjust-
    ment pattern.
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the OC
    adjustment pattern again.
    * During scanning of the OC adjustment pattern and calculat-
    ing of the adjustment value
    After completion of scanning, the adjustment value is calcu-
    lated.
    After completion of calculation of the adjustment value, the
    display is shifted to the result display screen.
    NO.Menu 
    display itemContent Description 
    1 OC ADJ OC adjustment OC document lead edge, 
    off-center, and sub scan 
    magnification ratio 
    adjustment
    2BK-MAG 
    ADJ BK main scan 
    magnification ratio 
    correctionBK main scan 
    magnification ratio 
    adjustment
    3 SPF ADJ SPF adjustment RSPF (front/back) 
    document lead edge, off-
    center, sub scan 
    magnification ratio 
    adjustment 
    4SETUP/
    PRINT ADJPrint position 
    adjustmentPrint lead edge adjustment, 
    all-cassette print off-center 
    (individual cassette, ADU) 
    adjustment
    5 RESULT Result display Display of the adjustment 
    result
    6 DATA Data display Display of data used for the 
    adjustment
    Adjustment itemAdjustment 
    menu
    Scanner OC Document lead edge OC ADJ
    Document off-center
    Sub scan 
    magnification ratio
    γ adjustment –
    RSPF SIDE1 
    (front)Document lead edge SPF ADJ 
    (RSPF)
    Document off-center
    Sub scan 
    magnification ratio
    SIDE2 
    (back)Document lead edge
    Document off-center
    Sub scan 
    magnification ratio
    CLOSE0
    A:
    SI MULATI ON NO.509Ù27
    SCANNER/FAX-SEND ALL EDGE ADJUSTMENT VALUE
    30
    :0:*100:	
    OK
    TEST
    FA XSCANNER
    A9æ30
    9çLEAD_EDGE(OC)
    B9æ209çFRONT_REAR(OC)
    C9æ209çTRAIL_EDGE(OC)
    D9æ309çLEAD_EDGE(SPF_SIDE1)
    Engine – BK main scan 
    magnification ratioBK-MAG ADJ
    MFT Print off-center SETUP/PRINT 
    ADJ
    Print lead edge
    CS1 Print off-center
    Print lead edge
    CS2 Print off-center
    Print lead edge
    ADU Print off-center
    Print lead edge
    CS3 Print off-center
    Print lead edge
    CS4 Print off-center
    Print lead edge
    LCC Print off-center
    Print lead edge Adjustment itemAdjustment 
    menu
    SI MULATI ONNO.5028TEST
    AUTOIMAGEPOSITIONADJUSTMENT9æSERVICE
    OCADJBK-MAGADJ
    SPFADJSETUP/PRINTADJ
    RESULTDATA
    1/1
    0
    CLOSE 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 103 
    • OC document lead edge adjustment
    • OC document off-center adjustment
    • OC sub scan magnification ratio adjustment
    6) The adjustment result is displayed.
    The value of this time is displayed together with the difference
    from the previous value in ( ).
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the OC
    adjustment pattern again.
    * When [RESCAN] button is pressed, scanning of the OC
    adjustment pattern is started again.
    * When [RETRY] button is pressed, the adjustment value is
    not saved to EEPROM and RAM and the display is shifted to
    the top menu screen.
    * When [DATA] button is pressed, the data used for the adjust-
    ment are displayed.
    7) When [OK] button is pressed, the adjustment value is saved to
    EEPROM and RAM and the display is shifted to the top menu
    screen.
    * When [BACK] button is pressed, the display returns to the
    result display screen.
     
    50-28
    Purpose: Adjustment
    Function (Purpose): Used to execute the BK main scan magnifi-
    cation ratio adjustment.
    (Auto void adjustment (Service instillation)
    (2: BK-main scan magnification ratio cor-
    rection))
    Section:—
    Item: Image quality
    Operation/Procedure
    1) When [BK-MAG ADJ] button is pressed on the top menu
    screen, the following screen is displayed.
    2) Select a cassette for self print of the BK magnification ratio
    adjustment pattern. (Only one cassette can be selected.)
    3) When [EXECUTE] button is pressed, self print of the BK mag-
    nification ratio adjustment pattern (print position adjustment
    pattern) is started.
    * During self print of the BK magnification ratio adjustment
    pattern
    After completion of self print, the display is shifted to the OC
    adjustment screen.
    4) Load the BK magnification ratio adjustment pattern to the OC.
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the BK
    magnification ratio adjustment pattern again.
    5) Press [EXECUTE] button to start scanning of the BK magnifi-
    cation ratio adjustment pattern.
    * During scanning of the main scan magnification ratio correc-
    tion pattern and calculating the magnification ratio adjust-
    ment value
    After completion of scanning, calculation of the adjustment
    value is started.After completion of calculation, the display is shifted to the
    result display screen.
    
    • BK magnification ratio adjustment
    6) The adjustment result screen is displayed.
    The value of this time is displayed together with the difference
    from the previous value in ( ).
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the BK
    magnification ratio adjustment pattern again.
    * When [RESCAN] button is pressed, scanning of the BK
    magnification ratio adjustment pattern is started again.
    * When [RETRY] button is pressed, the adjustment value is
    not saved to EEPROM and RAM and the display is shifted to
    the top menu screen.
    * When [DATA] button is pressed, the data used for the adjust-
    ment are displayed.
    7) When [OK] button is pressed, the adjustment value is saved to
    EEPROM and RAM and the display is shifted to the top menu
    screen.
    * When [BACK] button is pressed, the display returns to the result
    display screen.
     
    50-28
    Purpose: Adjustment
    Function (Purpose): Used to execute the RSPF (Front/Back)
    document lead edge, off-center, and sub
    scan magnification ratio adjustment.
    (Auto void adjustment (Service installation
    adjustment) (3: RSPF adjustment))
    Section:RSPF
    Item: Image quality
    Operation/Procedure
    1) When [SPF ADJ] button is pressed on the top menu screen,
    the screen on the right is displayed.
    2) Select an item to be adjusted. The display is shifted to the cas-
    sette select screen for printing the SPF adjustment pattern.
    3) Select a cassette for printing the SPF adjustment pattern.
    (Only one cassette can be selected.)
    4) When [EXECUTE] button is pressed, self print of the SPF
    adjustment pattern is started.
    * During self print of the SPF adjustment pattern
    After completion of self print, the display is shifted to the
    SPF adjustment screen.
    5) Load the SPF adjustment pattern to the SPF.
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the SPF
    adjustment pattern again.
    6) Press [EXECUTE] button to start scanning the SPF adjust-
    ment pattern (front surface).
    * During scanning of the SPF adjustment pattern (front sur-
    face) and calculating
    After completion of scanning the front surface, calculation of
    the adjustment value (front surface) is started.
    0SIMULATIONNO.5028TESTAUTOIMAGEPOSITIONADJUSTMENT9æSERVICE
    EXECUTE1/1
    MFTCS1CS2
    CLOSE
    0SIMULATIONNO.5028TESTAUTOIMAGEPOSITIONADJUSTMENT9æSERVICE
    EXECUTE1/1
    MFTCS1CS2
    CLOSE 
    						
    							MX-2300/2700 N/G  SIMULATION  7 – 104 After completion of calculation of the front surface adjust-
    ment value, the display is shifted to the SPF adjustment pat-
    tern (back surface) scan start screen.
    
    • SPF document lead edge adjustment front surface
    • SPF document off-center adjustment front surface
    • SPF sub scan magnification ratio adjustment front surface
    7) Load the SPF adjustment pattern to the SPF.
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the SPF
    adjustment pattern again.
    8) Press [EXECUTE] button to start scanning the SPF adjust-
    ment pattern (back surface).
    * During scanning of the SPF adjustment pattern (back sur-
    face)
    After completion of scanning the back surface, calculation of
    the adjustment value (back surface) is started.
    After completion of calculation, the display is shifted to the
    result display screen.
    
    • SPF Document lead edge adjustment back surface
    • SPF Document off-center adjustment back surface
    • SPF sub scan magnification ratio adjustment back surface
    (RSPF)
    9) The adjustment result screen is displayed.
    The value of this time is displayed together with the difference
    from the previous value in ( ).
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the SPF
    adjustment pattern (front/back) again.
    * When [RESCAN] button is pressed, scanning of the SPF
    adjustment pattern (front/back) is started again.
    * When [RETRY] button is pressed, the adjustment value is
    not saved to EEPROM and RAM and the display is shifted to
    the top menu screen.
    * When [DATA] button is pressed, the data used for the adjust-
    ment are displayed.
    10) When [OK] button is pressed, the adjustment value is saved to
    EEPROM and RAM and the display is shifted to the completed
    screen.
    * When [BACK] button is pressed, the display is shifted to the
    result display screen.
    
     
    50-28
    Purpose: Adjustment
    Function (Purpose): Used to execute the print lead edge adjust-
    ment and the all-cassette print off-center
    (individual cassette, ADU) adjustment.
    (Auto void adjustment (Service installation
    adjustment) (4: Print position adjustment)
    Section:—
    Item: Image quality
    Operation/Procedure
    1) When [SETUP/PRINT ADJ] button is pressed on the top menu
    screen, the screen on the right is displayed.
    2) When an item to be adjusted is selected, the display is shifted
    to the cassette select screen for printing the print position
    adjustment pattern.
    3) Select a cassette for use in print. (Two or more cassettes can
    be selected.) The selected cassette is highlighted.
    When the selected cassette is pressed again, it returns to the
    normal display.
    4) Press [EXECUTE] button to start self-printing of the print posi-
    tion adjustment pattern.
    * During self-printing of the print position adjustment pattern
    (CS3)
    * When two or more cassettes are selected, continuous self
    print (max. 7 sheets) is executed.
    After completion of self-printing, the display is shifted to the
    print position adjustment.
    5) Load the print position adjustment pattern (CS3) to the OC.
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the print
    position adjustment pattern again.
    6) Press [EXECUTE] button to start scanning of the print position
    adjustment (CS3).
    * During scanning of the print position adjustment pattern
    (CS3) and calculation
    After completion of scanning, calculation of the adjustment
    value (CS3) is started.
    After completion of calculation, the display is shifted to the
    result display screen.
    
    • Print lead edge (CS3/CS4)
    • Print off-center (CS3)
    * When two or more cassettes are selected, scanning and cal-
    culation are repeated for the number of output sheets (3 to
    max.7).
    7) The adjustment result screen is displayed.
    The value of this time is displayed together with the difference
    from the previous value in ( ).
    * **is displayed for an item which is not adjusted yet.
    * An item which is not installed is not displayed depending on
    the option status.
    * When [REPRINT] button is pressed, the display returns to
    the cassette select screen to allow self-printing of the print
    position adjustment pattern again.
    * When [RESCAN] button is pressed, scanning of the print
    position adjustment pattern is started again.
    * When [RETRY] button is pressed, the adjustment value is
    not saved to EEPROM and RAM and the display is shifted to
    the top menu screen.
    * When [DATA] button is pressed, the data used for adjust-
    ment are displayed.
    8) When [OK] button is pressed, the adjustment value is saved to
    EEPROM and RAM and the display is shifted to the top menu
    screen.
    Menu display item Content
    SIDE1 SPF adjustment front surface
    SIDE2 SPF adjustment back surface
    ALL SPF adjustment front/back surface
    SIMULATIONNO.5028TESTAUTOIMAGEPOSITIONADJUSTMENT9æSERVICE
    SIDE1SIDE2ALL
    1/1
    0CLOSE 
    						