MX-2300/2700 N/G SIMULATION 7 – 55 44-12 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): Used to check the sampling toner image patch density data in the image forming section correction (high density process correction). (This simulation is used to check whether the correction is normally executed or not.) Section:Process Item: Data (Machine condition) Operation/Procedure 1) Change the page with [↑] [↓] buttons. * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. 2) Change the display with the following buttons: [TARGET] button: Display of each color target [PATCH] button: Display of patch sampling data * When [CLOSE] button is pressed, the display shifts to the copy basic screen of simulation. * Copying can be performed also by pressing [COLOR]/[BLACK] key. * PATCH item: If the patch is converged to the target range in less than 10 times of patch acquisition, 0 is displayed in the other display items. * When [PATCH] button is pressed, the following page is dis- played. • n = 1 to 2 Page 1 • n = 3 to 4 Page 2 • n = 5 to 6 Page 3 • n = 7 to 8 Page 4 • n = 9 to 10 Page 5 OTHER 9/10 CRUM Left DESTINATION Machine side control CRUM destinationRefer to .CRUM information MODEL TYPE Machine model type 0 to 1 0 Right CRUM DEST_K CRUM destination Refer to .CRUM information CRUM DEST_C CRUM DEST_M CRUM DEST_Y 10/10 CNT Left PROCON COUNT HV Number of execution of high density process control 0 to 99999999 0 PROCON COUNT HT Number of execution of half tone process control0 to 99999999 0 Mode Page number Display item (*: correction value) Content description Display rangeDefault value Display code No. Destination Control specification 01 A AR control 02 B EX Japan AR control 03 C AR control 04 B Japan AR control 05 E AR control OTHER SIMULATION NO.44-09TESTPROCON DATA DISP (PROCON/NORMAL(M)) CLOSE BLACK : GB_ 230/630 DV_ 0/430 CYAN : GB_ 230/630 DV_ 0/430 MAGENTA : GB_ 230/630 DV_ 0/430 YELLOW : GB_ 230/630 DV_ 0/430BLACK : GB_ 230/600 DV_ 0/400 CYAN : GB_ 230/600 DV_ 0/400 MAGENTA : GB_ 230/600 DV_ 0/400 YELLOW : GB_ 230/600 DV_ 0/400 1/2CPY/PRN 0 Item Display itemContent descriptionDisplay rangeDefault value TA R G E T (Page 1)CARB DATA Calibration plate sensor value1 to 255 108 SEAL ADJ DATAJig patch seal sensor value1 to 255 108 ADK_SL (K) Developing characteristics gradient coefficient–9.99 to 9.99 0 ADK_INT (K) Developing characteristics intercept coefficient–999.9 to 999.90 ID(K) Sensor target value0.00 to 255.000.00 ID(CMY) Color sensor target set value0.00 to 255.000.00 PATCH (Page 1 to 5)N-1 Patch data nth front patch (n = 1 to 10)0 to 255 0 N-2 Patch data nth center patch (n = 1 to 10)0 to 255 0 N-3 Patch data nth rear patch (n = 1 to 10)0 to 255 0 PATCHTARGET SIMULATION NO.44-12TEST PATCH/TARGET DATA DISPLAY CLOSE CARB DATA : 108 SEAL ADJ DATA : 108 ADK SL(K) : 0.00 ADK INT(K) : 0.0TARGET(K) : 0.00 TARGET(C) : 0.00 TARGET(M) : 0.00 TARGET(Y) : 0.00 1/1 0
MX-2300/2700 N/G SIMULATION 7 – 56 44-13 Purpose: Adjustment Function (Purpose): Color image density sensor adjustment (Adjustment by the jig) Section:Process Item: Operation Operation/Procedure 1) When [EXECUTE] button is pressed, it is highlighted, and the color sensor adjustment is started by using the patch seal. * After completion of the color sensor adjustment, [EXECUTE] button returns to the normal display, and the set content is displayed. At that time, the necessary data are saved to EEPROM and RAM. * When [EXECUTE] button is pressed during the sensor adjustment, the sensor adjustment is interrupted and [EXE- CUTE] button returns to the normal display. * In case of an adjustment error, ERROR is displayed in the value display section at the right of the error item. No data are saved to EEPROM, and the operation is terminated. [EXECUTE] button returns to the original state. 1) The target value of CL is set and the LED emitting level is adjusted, and the operation is terminated. 44-14 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): Used to check the output level of the fusing temperature sensor, the machine tempera- ture sensor, and the humidity sensor. Section:Process Item: Operation Operation/Procedure 1) The machine enters this simulation, the current data are dis- played. * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. * Data are revised every 5sec. * For the temperature and humidity only, data outside the range are displayed as -. * The above display range is converted into hexadecimal number to display the AD value. * When the door open, the power of the sensor would be down, so that the sensor display is treated as outside the range. *°C is displayed as deg on the panel because of the display fonts. 44-16 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): Used to check data related to the toner density correction result. (This simulation allows to check that the correction is nor- mally performed or not.) Section: Process (Developing) Item: Operation Operation/Procedure 1) When the machine enters Simulation 44-16, the screen on the right is displayed. Specify the color with [K][C][M][Y] buttons. (In this example, [K] is selected.) The data of the selected color are displayed. * Only one color button can be selected. When a color button is selected, it is highlighted. (Black ([K]) is selected in the ini- tial state.) Item Display item DescriptionSet rangeDefault valueWriting APCS_CL CARB OUTCalibration plate sensor value1 to 255 108 YES BPCS_CL DARKColor dark voltage 0 to 255 0 NO C PCS_CL LED ADJColor sensor light emitting quantity adjustment value1 to 255 21 YES 0 SIMULATIONNO.4413TEST PATCH SEAL ADJUSTMENT EXECUTE PCSCL CARB OUT108: PCS CL DARK0: PCS CL LED ADJ21: 1/1 CLOSE Display item Description Display rangeDefault value TH_UM Fusing upper thermister main A/D value (Temperature °C/AD value)Temperature: 0 to 255 °C (±1°C) AD value: 0 to 1023Sensor value TH_UM_AD1 Fusing upper thermistor main compensation sensor temperature (°C) AD value (AD value)Temperature: 0.0 to 255.0 °C (±0.2°C) AD value: 0 to 1023Sensor value TH_UM_AD2 Fusing upper thermistor main sensor AD value (AD value)AD value: 0 to 1023 Sensor value TH_LM Fusing lower thermister main A/D value (Temperature °C/AD value)Temperature: 0 to 255 °C (±1°C) AD value: 0 to 1023Sensor value TH_US Fusing upper thermister sub A/D value (Temperature °C/AD value)Temperature: 0 to 255 °C (±1°C) AD value: 0 to 1023Sensor value TEMPRATURE Temperature thermister (Temperature/AD value)Temperature: –40.0 to 60.0°C (±0.1°C) AD value: 0 to 1023Sensor value HUMIDITY Humidity sensor (Humidity/AD value)Humidity: 5.0 to 90.0% (±0.1%) AD value: 0 to 1023Sensor value TH1_LSU Thermister 1 A/D value (Temperature °C/AD value)Humidity: 5.0 to 60.0 °C (±0.1°C) AD value: 0 to 255Sensor value 0 TH_UM_AD2XXX: SIMULATION NO.44-14TEST SENSOR DATA DISPLAY MONITOR 1/2 TH_UM255deg / XXX: TH_UM_AD1 255.0deg / XXX: TH_LM 255deg / XXX: TH_US 255deg / XXX: CLOSE
MX-2300/2700 N/G SIMULATION 7 – 57 * Change the page with [↓] or [↑] key. * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. 2) When [NEXT] button is pressed, data of another category are displayed. * When [NEXT] button is pressed on the last category data display, the data of the first category are displayed. * When [NEXT] button is pressed, the data of the next cate- gory are displayed regardless of the display page. * When [CLOSE] button is pressed, the display shifts to the copy basic screen of simulation. * Copying can be performed also by pressing [COLOR]/ [BLACK] key. * Common to KCMY * Common to KCMY * Common to KCMY * When the correction for the developer counter (life) or the humidity correction is inhibited (OFF) in SIM 44-01, the correction level is dis- played as 0. * Common to KCMY Display item Item contentSet rangeDefault value TONER DEN_LT(M)Current toner density sensor output value (final value) at middle speed1 to 255 129 TONER DEN_ST(M)Current toner density reference value (including all the correction values) at middle speed128 TONER DEN_LT(L)Current toner density sensor output value (final value) at low speed129 TONER DEN_ST(L)Current toner density reference value (including all the correction values) at low speed128 Display item Item content Content descriptionSet rangeDefault value AUTO DEVE (M) Automatic developer adjustment value (at middle speed)Sensor output value after execution of SIM 25-02 (at middle speed) 1 to 255 128 ALL(M) All correction reference value (at middle speed)Correction reference value (at middle speed) used to calculate all the correction values for auto developer adjustment value AUTO DEVE (L) Automatic developer adjustment value (at low speed)Sensor output value after execution of SIM 25-02 (at low speed) ALL(L) All correction reference value (at low speed)Correction reference value (at low speed) used to calculate all the correction values for auto developer adjustment value AREA Area correction value Correction value for environment area –127 to 1270 HUD Humidity correction value Correction value for humidity change PRINT RATE Print rate correction value Correction value for document print rate PROCON Process control correction value Correction value for high density process control result LIFE Life correction value Correction value for developer life SENSITIVITY Sensitivity correction value Correction for toner density sensor sensitivity 1 to 999 500 Display item Item content Content descriptionSet rangeDefault value AUTO DEVE VO(M) Automatic developer adjustment control voltage (at middle speed)Sensor control voltage value (at middle speed) after executing SIM 25-021 to 255 128 ALL VO(M) All correction reference control voltage (at middle speed)Control voltage reference value (at middle speed) used to calculate all the correction values for auto developer adjustment value AUTO DEVE VO(L) Automatic developer adjustment control voltage (at low speed)Sensor control voltage value (at low speed) after executing SIM 25-02 ALL VO(L) All correction reference control voltage (at low speed)Control voltage reference value (at low speed) used to calculate all the correction values for auto developer adjustment value AREA VO Area correction control voltage Control voltage correction value for environment area –127 to 1270 HUD VO Humidity correction control voltage Control voltage correction value for humidity change PRINT RATE VO Print rate correction control voltage Control voltage correction value for document print rate PROCON VO Process control correction control voltage Control voltage correction value for high density process control result LIFE VO Life correction control voltage Control voltage correction value for developer life SENSITIVITY VO Sensitivity correction control voltage Control voltage correction value for toner density sensor sensitivity 1 to 999 500 ENV VO Environment correction control voltage Control voltage correction value under high temperature environment –127 to 1270 Display item Item content Content descriptionSet rangeDefault value AUTO DEVE AREA Auto developer adjustment area Auto developer adjustment humidity area display 1 to 14 8 AREA Current area Current humidity area display
MX-2300/2700 N/G SIMULATION 7 – 58 44-21 Purpose: Setting Function (Purpose): Used to register the half tone process con- trol reference value (half tone correction). Section:Process Item: Operation Operation/Procedure 1) When the machine enters Simulation 44-21, the screen shown on the right is displayed. When [EXECUTE] button is pressed, the process control refer- ence value is registered. (When [ECXECUTE] button is pressed during execution, the operation is interrupted.) 2) The display automatically shifts to the first step completion screen or the sensor adjustment error screen. When the display shifts to the first step completion screen, the second step is automatically started. When the display shifts to the sensor adjustment error screen, press [EXECUTE] button to resume the operation. * When the process control is executed second time, 2nd is displayed. 3) When the second step is completed, the following message is displayed. (The message is automatically proceeds.) BLACK: 2ND STEP BLACK END CYAN: 2ND STEP CYAN END MAGENTA: 2ND STEP MAGENTA END YELLOW: 2ND STEP YELLOW END 4) The display shifts to the normal completion screen or the error screen automatically. When [RESULT] button is pressed, the result screen is dis- played. * Data of each color are displayed with [K] [C] [M] [Y] buttons. Only one color button can be selected. The selected button is highlighted. (Black ([K]) is selected in the initial state.) * When [EXECUTE] button is pressed, the process control reference value setting is performed again. 44-22 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): Used to check the toner patch image den- sity level of each color in half tone image forming section correction (process correc- tion). (This simulation is used to check that the correction is normally executed or not.) Section: Process Item: Data (Machine condition) Operation/Procedure 1) Change the page with [↑] [↓] buttons. * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. 2) Select desired patch sampling data with the following buttons: [1ST STEP] button: [1ST STEP] patch sampling data display [2ND STEP] button: [2ND STEP] patch sampling data display * When [CLOSE] button is pressed, the display shifts to the copy basic screen of simulation. * Copying can be performed also by pressing [COLOR]/[BLACK] key. 44-24 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): (This simulation is not used in the market.) Used to display the process control result. Section: Process Item: Data (Machine condition) Operation/Procedure 1) Select a color with [K][C][M][Y] buttons. (In this example, [K] is selected.) The data of the selected color are displayed. * Only one color button can be selected. The selected button is highlighted. (In the initial screen, black ([K]) is selected.) * Change the display page with [↓] or [↑] . * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. 2) When [NEXT] button is pressed, data of another category are displayed. * When [NEXT] button is pressed on the last category data display, the data of the first category are displayed. 0SIMULATIONNO.44-16TESTTONER CONTROL DATA DISPLAY NEXT TONERDEN_LT(M)128: TONERDEN_ST(M)128: TONERDEN_LT(L)128: TONERDEN_ST(L)128: 1/1KMYC CLOSE SIMULATIONNO.4421TESTHALF TONE PROCON STANDARD VALUE REGISTER EXECUTE 0CLOSE TOUCH [EXECUTE] THEN EXECUTION START. Button item Display item Content description 1ST STEP ID_n 1ST patch data display (n = 1 to 5) 2ND STEP ID_n 2ND patch data display (n = 1 to 16) 2ND STEP1ST STEP SIMULATIONNO.4422TESTHALF TONE CORRECT RESULT CLOSE 1/1 0 PTK/BASE PTC PTM PTY PTK/BASE PTC PTM PTY ID 4 : 255/255 255 255 255 ID 1 : 255/255 255 255 255 ID 5 : 255/255 255 255 255 ID 2 : 255/255 255 255 255 ID 3 : 255/255 255 255 255
MX-2300/2700 N/G SIMULATION 7 – 59 * When [NEXT] button is pressed, the data of the next cate- gory are displayed regardless of the display page. * When [CLOSE] button is pressed, the display shifts to the copy basic screen of simulation. * Copying can be performed also by pressing [COLOR]/[BLACK] key. * When the display item is not executed yet, “–––” is displayed. In case of an error, ERR is displayed. * An error display is not made for the reference value and the cor- rection value, and the previous value is displayed. 44-25 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): Used to check the initial condition of pro- cess control (half tone correction). Section: Process Item: Data (Machine condition) Operation/Procedure 1) Select a color with [K] [C] [M] [Y] buttons. (In this example, [K] is selected.) The data of the selected color are displayed. * Only one color button can be selected. The selected button is highlighted. (In the initial screen, black ([K]) is selected.) 2) Select the set item with [↑] and [↓] buttons. The highlighted set value is switched and the value is dis- played in the setting area. * If there is any item over [↑], an active display is made and item is shifted. If there is no item over [↑], the display grays out and the operation is invalid. If there is any item under [↓], an active display is made and item is shifted. If there is no item over [↓], the display grays out and the operation is invalid. 3) Enter the set value with 10-key. * Press [C] key to clear the entered values. 4) When [OK] button is pressed, it is highlighted and the current set data are saved to EEPROM and RAM. * Also when [OK], [↑], [↓], [COLOR], or [BLACK] key is pressed, the current set value is saved to EEPROM and RAM. CategoryPage numberDisplay item Content Coefficient 1/2 [RIZE] Low density rising point [SATURATE] High density saturation point [STEP] (Saturation pint – Rising point) / 10 [EX-LOW] Coefficient of the approximation formula of lowest density [LOW] Coefficient of the approximation formula of low density [CONNECT] Coefficient of the approximation formula when connecting low density and middle density 2/2 [MID] Coefficient of the approximation formula of middle density [HIGH] Coefficient of the approximation formula of high density [CONNECT POINT] Density sections connection output ratio Reference value1/1 [SENSOR_TARGET] Half tone process control reference value Correction value1/1 [S_VALUE] Half tone process control correction amount For printer 1/3 [PRINTER_S_VALUE] Printer half tone process control correction value 2/3 [PRINTER_BASE_DI THER_VALUE]Printer half tone process control reference dither value 3/3 [PRINTER_AUTO_HT _VALUE]Printer auto density adjustment correction value KMYC SIMULATIONNO.449Ù24TESTHALF TONE PROCON RESULT DISPLAY CLOSE [RIZE] 16 [SATURATE] 109 [STEP] 9.3 [EX-LOW] A: 0.0 , B: 100.0 [LOW] A:- 0.013 , B:- 0.569 , C: 107.444 [CONNECT] A: 0.0 , B: 0.0 1/2NEXT 0 Item DisplaySet rangeContentDefault value A 1ST PATCH 0 to 255 Half tone process control 1ST step 1st patch print gradation40 B 2ND PATCH 0 to 255 Half tone process control 1ST step 2nd patch print gradation60 C 3RD PATCH 0 to 255 Half tone process control 1ST step 3rd patch print gradation80 D 4TH PATCH 0 to 255 Half tone process control 1ST step 4th patch print gradation100 E 5TH PATCH 0 to 255 Half tone process control 1ST step 5th patch print gradation255 A: A40 B60 C80 D100 1ST PATCH2ND PATCH3RD PATCH4TH PATCH SIMULATION NO.44-25 HALF TONE PROCON INITIAL VALUE DISPLAY 40 0255 OK TEST KCMY 0 CLOSE
MX-2300/2700 N/G SIMULATION 7 – 60 44-26 Purpose: Adjustment Function (Purpose): Used to execute the half tone process con- trol forcibly. Section:Process Item: Operation Operation/Procedure 1) When the machine enters Simulation 44-26, the screen on the right is displayed. When [EXECUTE] button is pressed, the process control is forcibly executed. (When [EXECUTE] button is pressed during execution, the operation is interrupted.) 2) The display automatically shifts to the first step completion screen or the sensor adjustment error screen. When the display shifts to the first step completion screen, the second step is automatically started. When the display shifts to the sensor adjustment error screen, press [EXECUTE] button to resume the operation. 3) When the second step is completed, the following message is displayed. (The message is automatically proceeds.) BLACK : 2ND STEP BLACK END CYAN : 2ND STEP CYAN END MAGENTA : 2ND STEP MAGENTA END YELLOW : 2ND STEP YELLOW END 4) The display shifts to the normal completion screen or the error screen automatically. When [RESULT] button is pressed, the result screen is dis- played. * Data of each color are displayed with [K][C][M][Y] buttons. Only one color button can be selected. The selected button is highlighted. (In the initial screen, [K] is selected.) * When [EXECUTE] button is pressed, the half tone process control correction value setting is resumed. 44-27 Purpose: Data clear Function (Purpose): Used to clear the half tone process control correction value. Section: Process Item: Clear Operation/Procedure 1) Press [EXECUTE] button. [EXECUTE] button is highlighted, and [YES] and [NO] buttons become active display. 2) Press [YES] button. The half tone process control correction value is cleared. [YES] button is highlighted. * When [NO] button or [EXECUTE] button is pressed, [EXE- CUTE] button returns to the normal display and [YES] and [NO] buttons gray out. * After completion of clearing the half tone process control correction value, [EXECUTE] button returns to the normal display and [YES] and [NO] buttons gray out. * The restored data are saved to EEPROM and RAM. 44-28 Purpose:Setting Function (Purpose): Used to set the timing (ON/OFF) of process control execution. Section: Process Item: Operation Operation/Procedure 1) Select the set item with [↑] and [↓] buttons. The highlighted set value is switched and the value is dis- played in the setting area. * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. 2) Enter the set value with 10-key. * Press [C] key to clear the entered values. 3) When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is pressed, the current set data are saved to EEPROM and RAM.Display Content COMPLETE Normal completion INTERRUPTION Forcible interruption CL_SEN_ADJ_ERR Color sensor adjustment error BK_SEN_ADJ_ERR Black sensor adjustment error [YMCK] High density process control [YMCK] error CONNECTION_ERR Connection error SIMULATIONNO. 4426TESTHALF TONE DENSITY CORRECT EXECUTION EXECUTE 0CLOSE TOUCH [EXECUTE] THEN EXECUTION START. Standard value restore item 1 to 15 Half tone process control correction value 0 SIMULATIONNO.4427TEST HALFTONE PROCON ADJUSTMENT DATA CLEAR CLOSE EXECUTEARE YOU SURE?YESNO
MX-2300/2700 N/G SIMULATION 7 – 61 * A – H display: Item name: Detail display. Example: SW ON:YES 44-29 Purpose: Setting Function (Purpose): Enable/disable of the half tone correction during each job is switched. Section:Process Item: Operation Operation/Procedure 1) Select the set item with [↑] and [↓] buttons. The highlighted set value is switched and the value is dis- played in the setting area. * If there is any item over [↑], an active display is made and item is shifted. If there is no item over [↑], the display grays out and the operation is invalid. If there is any item under [↓], an active display is made and item is shifted. If there is no item over [↓], the display grays out and the operation is invalid. 2) Enter the set value with 10-key. * Press [C] key to clear the entered values. 3) When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is pressed, it is highlighted and the current set data are saved to EEPROM and RAM. * The actual display is Display item: Set range. Example: COPY:HV → PHT → HT Item Display Content Set range Default value A Process control execution YES/NO settingSW ON YES When supplying the power (when canceling sleep.) Allowed 0 to 1 0 0 NO Inhibited 1 B 24H YES When READY (sleep setting) is kept for 24H or more Allowed 0 to 1 0 0 NO Inhibited 1 C HUM YES The temperature and humidity in the machine are monitored every 2 hours (which can be set with Item I), and they are more than the specified level (more than the set value of item 10) compared with the previous process control.Allowed 0 to 1 0 0 NO Inhibited 1 D REV1 YES When the power is supplied, and when the accumulated traveling distance of BK or M position drum unit reaches a certain level.Allowed 0 to 1 0 0 NO Inhibited 1 E REV2 YES When the accumulated traveling distance of BK or M position drum unit reaches a certain level from the previous density correction.Allowed 0 to 1 0 0 NO Inhibited 1 F INITIAL YES When warming up after clearing the counter of OPC drum and the developing unit.Allowed 0 to 1 0 0 NO Inhibited 1 G PIX YES When one of the accumulated toner counts for each colors reaches over the specified count from the previous high density correction.Allowed 0 to 1 0 1 NO Inhibited 1 H HUM_LIMIT YES The set conditions of item C are added to the set conditions of items A to G.Allowed 0 to 1 0 1 NO Inhibited 1 I HUM HOUR Item C temperature/humidity monitor monitoring time interval setting (H: Hour)1 to 24 2 J HUM_DIF Specified value of area difference compared with that in the previous process control execution of item C1 to 9 2 K BK_RATIO Setting of the zoom ratio (%) of BK position OPC drum traveling distance of item E1 to 999 20 L M_RATIO Setting of the zoom ratio (%) of M position OPC drum traveling distance of item E1 to 999 20 M PIX_RATIO Pitch count zoom ratio setting (%) 1 to 999 100 0 A: A9æ0 B9æ0 C9æ0 D9æ09çSWON9æNO 9ç24H9æYES 9çHUM9æYES 9çREV19æYES SIMULATIONNO.449Ù28 PROCONTIMINGADJUSTMENT 0 :0:*1: OK TESTCLOSE ItemDisplay itemDescription of itemSet rangeDefault value A COPY Copier 0 to 4 0: No execution 4 B PRINTER Printer 1: HV only 2 CFAX FAX 2: HV → PHT 2 D SELF PRINTSelf print 3: HV → HT 4 4: HV → PHT → HT 0 A: A9æ4 B9æ2 C9æ2 D9æ49çCOPY : HV 9çPRINTER : HVÈPHTÈHT 9çFA X : H VÈPHT 9çSELF PRINT : HVÈPHTÈHT SIMULATIONNO.44-29 HALF TONE SETTING 4 :0:*4: OK TESTCLOSE
MX-2300/2700 N/G SIMULATION 7 – 62 44-31 Purpose: Adjustment Function (Purpose): Used to perform the phase adjustment for OPC drum deflection. (Used to adjust the phases of four OPC drums deflection.) Section: Process (OPC drum) Item: Adjustment Operation/Procedure 1) Select the set item with [↑] and [↓] buttons. The highlighted set value is switched and the value is dis- played in the setting area. * If there is any item over [↑], an active display is made and item is shifted. If there is no item over [↑], the display grays out and the operation is invalid. If there is any item under [↓], an active display is made and item is shifted. If there is no item over [↓], the display grays out and the operation is invalid. 2) Enter 3 with 10-key in the print mode of set item A to change the set value. (Default is 3.) * Press [C] key to clear the entered values. 3) Set A3 paper in the cassette 1 tray. 4) Use [↓] button to shift to the paper of set item C and enter 3 with 10-key. (The default is 3.)5) When [OK] button is pressed, it is highlighted and the current set value is saved to EEPROM and RAM. * When [EXECUTE], [↑], [↓], [COLOR], or [BLACK] key is pressed, the current set value is saved to EEPROM and RAM. 6) Check the output pattern to examine deflections of C, M, Y, and K. • The deflection is within 2 lines. → Simulation is completed. • The deflection is not within 2 lines. → Go to step 9. 7) Shift to the set item A and enter 1 with 10-key. 8) When [EXECUTE] button is pressed, the drum deflection adjustment pattern is printed. (8 sheets are outputted.) * Numbers 1 – 8 are printed sequentially in the output pattern. 9) Check 8 sheets of print patterns to find the print pattern in which the deflection is within2 lines for C, M, and Y. Set the print value of the print pattern to set item B. 10) To check the deflection in the set value, enter 3 to set item A with 10-key, and press [EXECUTE] button to print one sheet of the drum deflection adjustment pattern. * When [C], [CA], [SYSTEM SETTINGS], or [EXECUTE] button is pressed during self print, the operation is interrupted. * After completion of self print, [EXECUTE] button returns to the original state. * For cassette selection, the manual feed cassette is set. (Set item C is 1) * The display of item A/C is Display item: Detail of display. Example: PAPER : CS2 44-43 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): Used to display each developing unit installing state AD value. This simulation is added to check the sam- pling data of the detection judgment of developing unit installation not only as the judgment result (trouble display) but also as the current state value. Section: Process (Developing) Item: Data (Machine condition) Operation/Procedure 1) When the machine enters Simulation 44-43, the data stored in EEPROM are displayed. * Data are revised every 5sec. ItemDisplay item: Detail of displayDescriptionSet rangeDefault valueWriting A PRINT MODE45deg Print mode 45 degree Deflection check pattern every 45 degree (8 sheets of print) (1) 0° (2) 45° (3) 90° (4) 135° (5) 180° (6) 225° (7) 270° (8) 315° * The number in ( ) is printed on the output pattern.1 to 3 1 3 (SET VA L U E )NO 90deg 90 degree 2: Deflection check pattern for every 90 degree (4 sheets of print) (1) 0° (3) 90° (5) 180° (7) 270° * The number in ( ) is printed on the output pattern.2 SET VALUE SET VALUE 3: Deflection check print (One sheet of print) at the set value. 3 B COLOR Phase adjustment value BK → CLAngle step 0° (1) → 45° (2) → 90° (3) → 135° (4) → 180° (5) → 225° (6) → 270° (7) → 315° (8)1 to 8 2 YES C PAPER MFT Cassette selection Manual feed 1 to 6 1 3 (CS2)NO CS1 Machine 1 stage 2 CS2 Machine 2 stage 3 CS3 Option paper feed desk 1 stage 4 CS4 Option paper feed desk 2 stage 5 LCC LCC 6 0 A:A9æ3 B9æ29çPRINT MODE9æSETVA L U E 9çCOLOR SIMULATIONNO.44-31 DRUM POSITION SETTING 3 :1:*3: OK TEST EXECUTE CLOSE C9æ39çPAPER:CS2
MX-2300/2700 N/G SIMULATION 7 – 63 (*): The kind of a developing unit is identified with the ID number. For ID and the contents of developing unit models, refer to ‚ below. 44-52 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): (This function is not used. Do not operate.) Used to check the toner patch image den- sity level of each color in 1 pixel half tone correction. (The simulation is used to check whether the correction is normally executed or not.) Section:Process Item: Data (Machine condition) Operation/Procedure 1) Change the page with [↑] [↓] buttons. * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. * When [CLOSE] button is pressed, the display shifts to the copy basic screen of simulation. * Copying can be performed also by pressing [COLOR]/[BLACK] key. 44-54 Purpose: Adjustment/Setup/Operation data output/ Check (Display/Print) Function (Purpose): (This function is not used. Do not operate.) Used to display the 1 pixel half tone correc- tion result. Section: Process Item: Data (Machine condition) Operation/Procedure 1) Select a color with [K][C][M][Y] buttons. (In this example, [K] is selected.) The data of the selected color are displayed. * Only one color button can be selected. The selected button is highlighted. (In the initial screen, black ([K]) is selected.) * Change the display page with [↑] [↓] buttons. * If there is a page over [↑], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid. If there is a page under [↓], an active display is shown and the page moves down. If there is no page downward, the display grays out and the operation becomes invalid. 2) When [NEXT] button is pressed, data of another category are displayed. * When [NEXT] button is pressed on the last category data display, the data of the first category are displayed. * When [NEXT] button is pressed, the data of the next cate- gory are displayed regardless of the display page. * When [CLOSE] button is pressed, the display shifts to the copy basic screen of simulation. * Copying can be performed also by pressing [COLOR]/[BLACK] key. Item Item name Item contentDisplay rangeRemark A DVCH KIND K K developing unit kind state 1 to 9 (*) Developing unit model identification information saved in EEPROM on the machine side. A judgment is made by verifying this information and the model information in CRUM. Since the result (OK or NG) is known when warming up, the error display is not required in SIM. The display is made by the division code of 1 to 9 instead of the model name. B DVCH KIND C C developing unit kind state 1 to 9 (*) C DVCH KIND M M developing unit kind state 1 to 9 (*) D DVCH KIND Y Y developing unit kind state 1 to 9 (*) E DVCH_AD_K K developing unit installation AD value 0 to 255 Actual measurement value of the developing unit output voltage AD value F DVCH_AD_C C developing unit installation AD value 0 to 255 Actual measurement value of the developing unit output voltage AD value G DVCH_AD_M M developing unit installation AD value 0 to 255 Actual measurement value of the developing unit output voltage AD value H DVCH_AD_Y Y developing unit installation AD value 0 to 255 Actual measurement value of the developing unit output voltage AD value ID number Developing unit model name 1OEM4, etc. 2 PASTEL MFP 3 PASTEL PRT 4C-JUPITER MFP 5 C-JUPITER PRT 6OEM1, etc. 7OEM2, etc. 8 OEM3, etc. 9 No developing unit DVCH KIND K SIMULATIONNO.44-43TEST DEVELOPER UNIT AD MONITOR :DVCH AD K: DVCH KIND C:DVCH AD C: DVCH KIND M:DVCH AD M: DVCH KIND Y:DVCH AD Y: 1/1 0 CLOSE Display item Content description Display range ID_n Patch data display (n = 1 to 16)0 to 255 SIMULATIONNO.4452TEST 1 PIXEL HALF TONE CORRECT RESULT CLOSE 1/3 0 PTK PTC PTM PTY PTK PTC PTM PTY ID 4 : 255 255 255 255 ID 1 : 255 255 255 255 ID 5 : 255 255 255 255 ID 2 : 255 255 255 255 ID 3 : 255 255 255 255 ID 6 : 255 255 255 255
MX-2300/2700 N/G SIMULATION 7 – 64 * When the display item is not executed yet, “–––” is displayed. In case of an error, “ERR” is displayed. * An error display is not made for the reference value and the correction value, and the previous value is displayed. 44-56 Purpose: Setting Function (Purpose): (This function is not used. Do not operate.) Used to perform the forcible execution of 1 pixel half tone correction. Section:Process Item: Operation Operation/Procedure 1) When the machine enters Simulation 44-56, the following screen is displayed. When [EXECUTE] button is pressed, the forcible execution of 1 pixel process control is started. (When [EXECUTE] button is pressed during execution, the operation is interrupted.) * In case of a sensor adjustment error, press [EXECUTE] but- ton to resume the operation. 2) The display shifts to the normal completion screen or the error screen automatically. When [RESULT] button is pressed, the result screen is dis- played. * Select a color with [K] [C] [M] [Y] buttons. The data of the selected color are displayed. Only one color button can be selected. The selected button is highlighted. (In the initial screen, black ([K]) is selected.) * When [EXECUTE] button is pressed, the 1 pixel process control correction value setting is performed again. 44-57 Purpose: Data clear Function (Purpose): (This function is not used. Do not operate.) Used to clear the correction value of 1 pixel half tone correction. Section: Process Item: Data clear Operation/Procedure 1) Press [EXECUTE] button. [EXECUTE] button is highlighted, and [YES] and [NO] buttons becomes active display. 2) Press [YES] button. * The half tone correction value is cleared. [YES] button is highlighted. * When [NO] button or [EXECUTE] button is pressed, [EXE- CUTE] button returns to the normal display, and [YES] and [NO] buttons gray out. * After completion of clearing the half tone correction value, [EXECUTE] button returns to the normal display, and [YES] and [NO] buttons gray out. * The cleared data are saved to EEPROM and RAM. Category Page number Display item Content Display range Approximation result1/2 [EX-LOW] EXTRA lowest density area approximation formula coefficientA: –10.000 to +10.000 B: –255.000 to +255.000 [LOW] Low density approximation formula coefficient A: –10.000 to +10.000 B, C:-255.000 to +255.000 [CONNECT] Approximation formula coefficient when connecting low density and middle densityA: –10.000 to +10.000 B: –255.000 to +255.000 [MID] Middle density approximation formula coefficient A: –10.000 to +10.000 B, C: –255.000 to +255.000 2/2 [HIGH] High density approximation formula coefficient A: –10.000 to +10.000 B: –255.000 to +255.000 [CONNECT SENSOR] Sensor output at connecting point of each density area #1 to #4: 0 to 255 Reference register value1/1 [SENSOR_TARGET] Reference value registration value of each color and each point of 1 pixel half tone correction #1 to #15 Correction value 1/1 [S_VALUE] Correction value of each color and each point of 1 pixel half tone correction#1 to #15 Display Content COMPLETE Normal completion INTERRUPTION Forcible interruption CL_SEN_ADJ_ERR Color sensor adjustment error BK_SEN_ADJ_ERR Black sensor adjustment error [YMCK] High density process control [YMCK] error CONNECTION_ERR Connection error KMYC SIMULATIONNO.449Ù54TEST1PIXELHALFTONERESULTDISPLAY CLOSE [EX-LOW] A: 01.000 , B: 100.000 [LOW] A: -10.000 , B: -200.000 , C: 200.000 [CONNECT] A: 10.000 , B: -150.000 [MID] A: 05.000 , B: 200.000 ,C: 150.000 1/2NEXT 0 Half tone correction value clear item 1 to 15 Process control half tone correction value SIMULATIONNO.4456TEST 1PIXELHALF TONE DENSITY CORRECT EXECUTION EXECUTE 0 CLOSE TOUGH [EXECUTE] THEN EXECUTION START. 0 SIMULATIONNO.4457TEST 1PIXELHALFTONE ADJUSTMENT DATA CLEAR CLOSE EXECUTEARE YOU SURE?YESNO