 SOP Common  Table 9.18  ALWAYS 
 
9.1.1.2 Secondary Capture IOD  
Table 9.2  
IOD OF CREATED SECONDARY CAPTURE SOP INSTANCES  
IE   Module  Reference Presence of Module  
Patient Patient   Table 9.5   ALWAYS 
Study  General Study
  Table 9.6   ALWAYS Patient Study   Table 9.7   ALWAYS 
Series General Series   Table 9.9   ALWAYS 
Equipment General Equipment   Table 9.10  ALWAYS 
SC Equipment   Table 9.21  ALWAYS 
Image  General Image 
Table 9.19  ALWAYS 
Image Pixel   Table 9.20  ALWAYS 
SC Image   N.A....

Page 72

 
9.1.1.4 Comprehensive Structured Report IOD  
Table  9.4  
IOD OF CREATED COMPREHENSIVE STRUCTURED REPORT SOP INSTANCES  
IE Module Reference Presence of Module 
Patient Patient   Table 9.5   ALWAYS 
Study  General Study
  Table 9.6   ALWAYS Patient Study   Table 9.7   ALWAYS 
Series SR Document Series   Table 9.24  ALWAYS 
Equipment General Equipment   Table 9.10  ALWAYS 
Document  SR Document General
  Table 9.25  ALWAYS SR Document Content   Table 9.26  ALWAYS 
SOP Common   Table 9.27  ALWAYS...

Page 73

 Table 9.6  
GENERAL STUDY MODULE OF CREATED SOP INSTANCES  
Attribute Name  Tag  VR  Value  
Presence 
of Value Source  
Study Instance UID  (0020,000D )  UI  Same value as in 
MWL or auto 
generated   ALWAYS
 MW L/
 
AUTO  
Study Date   (0008,0020) DA Study’s Start Date ( 0040,0244).  ALWAYSU
A
  AUTO
 
Study Time   (0008,0030) TM Study’s Start Time ( 0040,0245). ALWAYS AUTO  
Referring Physician’s Name  (0008,0090) PN Only Last, First and Middle 
names from  
MWL, sent as “Last, First, Middle” in the...

Page 74

 Attribute Name  Tag  VR  Value  
Presence 
of Value Source  
>Coding Scheme 
Designator   (0008,0102)
 SH Same  value as MWL attribute  VNAP  MW L 
>Coding Scheme Version  (0008,0103)  SH Same value as MWL attribute  VNAP  MW L 
>Code Meaning  (0008,0104) LO Same value as MWL attribute  VNAP  MW L 
 
 
Table  9.7  
PATIENT STUDY MODULE  OF CREATED SOP INSTANCES  
Attribute Name  Tag  VR  Value   Presence 
of Value  Source
 
Admitting Diagnosis 
Description   (0008,1080)
 LO  Same attribute as MW L...

Page 75

 Attribute Name  Tag  VR  Value  
Presence of 
Value Source  
Series Instance UID  (0020,000E )  UI  Auto -generated   ALWAYS  AUTO 
Series Number  (0020,0011) IS  A number unique  within the Study. ALWAYS   AUTO 
Series Date   (0008,0021) DA Date of first image in series.  ALWAYSUA  AUTO 
Series Time  (0008,0031) TM Time of first image in series.  ALWAYS  AUTO 
Performing Physician’s 
Name  (0008,1050)
 PN MWL Scheduled Performing 
Physician’s 
Name (0040,0006)  VNAP
  MW L 
Protocol Name  (0018,1030)...

Page 76

 Attribute Name  Tag  VR  Value  
Presence of 
Value Source  
Performed Protocol Code 
Sequence   (0040,0260)
 SQ Zero length, or mapped from MWL 
Scheduled Protocol Code 
Sequence 
(0040,0008)   VNAP
  MW L 
 
 
Table  9.10  
GENERAL EQUIPMENT MODULE OF CREATED SOP INSTANCES  
Attribute  Name  Tag  VR  Value   Presence of 
Value   Source
 
Manufacturer  (0008,0070)  LO   Philips Medical Systems   ALWAYS AUTO  
Institution Name  (0008,0080)  LO   From Setups configuration*
 
(requires power cycle)...

Page 77

 Attribute Name  Tag  VR  Value  
Presence of 
Value Source  
Source Image 
Sequence 
(0008,2112) SQ This sequence will be present only for 3D 
images from motorized 3D  transducers, or  
freehand acquisition from single- array 
transducers.   
ANAP AUTO 
> Referenced 
SOP Class UID 
(0008,1150) UI SOP Class UID of Ultrasound Multiframe Image ANAP AUTO 
> Referenced 
SOP Instance 
UID 
(0008,1155) UI The value is the SOP Instance UID of the 
associated 3D volume.  
 
This value links this image, intended...

Page 78

 
* Analysis Type selection is determined by the analysis package associated with the transducer / preset selection. 
**  Instance Number will be mapped to View Number when studies with General Imaging Protocol Images are 
configured  to export shuffled. Images that are not part of the protocol will have the instance number offset by 10,000.  
 
 
Table 9.12  
IMAGE PIXEL MODULE OF CREATED US OR US MULTIFRAME SOP INSTANCES  
Attribute Name  Tag  VR  Value   Presence of 
Value   Source
 
Samples per Pixel...

Page 79

 Table 9.14  
MULTI -FRAME MODULE OF CREATED MULTIFRAME  US OR SC  SOP INSTANCES  
Attribute Name  Tag  VR  Value  
Presence 
of Value Source  
Number of 
Frames  (0028,0008)
 IS  # of frames in object   ANAP  AUTO 
Frame Increment 
Pointer   (0028,0009)
 AT  0x0018 1063:    Frame Time only   ANAP  AUTO 
 
 
Table  9.15  
US REGION CALIBRATION MODULE OF CREATED US IMAGE OR US MULTIFRAME  IMAGE SOP INSTANCES 
Attribute Name  Tag  VR  Value   Presence 
of Value  Source
 
Sequence of 
Ultrasound 
Regions...

Page 80

 Attribute Name  Tag  VR  Value  
Presence 
of Value Source  
T ype Tissue = 0001H 
PW Spectral Doppler = 0003H  
CW   Spectral Doppler = 0004H  
>Region Flags (0018,6016)  UL Bit mask. See DICOM PS3.3 C.8.5.5.1.3:   ALWAYS AUTO  
 
 
Table  9.16  
US IMAGE MODULE OF CREATED US IMAGE OR US MULTIFRAME IMAGE SOP INSTANCES  
Attribute Name  Tag  VR  Value  Presence 
of Value  Source
 
Samples Per Pixel  (0028,0002)  US “1” for M
ONOCHROME 2, only if “Export 
Monochrome” is selected, otherwise,    
“3” for...