Page 81
Attribute Name Tag VR Value Presence of Value Source Time(s) Event Timer Name(s) (0008,2132) LO Timer ANAP AUTO View Code Sequence (0054 ,0220) SQ Sequence that describes the view of the patient anatomy in this image. Only a single Item shall be permitted in this Sequence. Acquisition DateTime (0008,002A) DT The date and time that the acquisition of data that resulted in this image started. ALWAYSU A AUTO Trigger Time (0018,1060) DS nnn msec. ANAP AUTO Heart...
Page 82
9.1.1.5.3 Secondary Capture Image Modules Table 9.19 GENERAL IMAGE MODULE OF CREATED SECONDARY CAPTURE SOP INSTANCES Attribute Name Tag VR Value Presence of Value Source Instance Number** (0020,0013) IS Generated by device, increments from “1” in each Secondary Capture series ALWAYS AUTO Content Date (0008,0023) DA ALWAYSUA AUTO Content Time (0008,0033) TM ALWAYS AUTO Image Type (0008,0008) CS DERIVED/PRIMARY/ ALWAYS CONFIG Acquisition DateTime...
Page 83
Attribute Name Tag VR Value Presence of Value Source High Bit (0028,0102) US High bit is 7 ALWAYS AUTO Pixel Representation (0028,0103) US “0” pixels are Unsigned I ntegers ALWAYS AUTO Pixel Data (7FE0,0010) OW / OB ALWAYS AUTO Planar Configuration (0028,0006) US Present when image is RGB. Value is “0”. ANAP AUTO Table 9.21 SC EQUIPMENT MODULE OF CREATED SECONDARY CAPTURE SOP INSTANCES Attribute Name Tag VR Value Presence of Value Source...
Page 84
Attribute Name Tag VR Value Presence of Value Source Instance Creation Date (0008,0012) DA ALWAYSUA AUTO Instance Creation Time (0008,0013) TM ALWAYS AUTO 9.1.1.5.4 Comprehensive Structured Report Modules Table 9.24 SR DOCUMENT SERIES MODULE OF CREATED COMPREHENSIVE SR SOP INSTANCES Attribute Name Tag VR Value Presence of Value Source Modality (0008,0060) CS “SR” ALWAYS AUTO Series Instance UID ( 0020,000E ) UI Auto -generated ALWAYS AUTO...
Page 85
Attribute Name Tag VR Value Presence of Value Source >Referenced Series Sequence (0008,1115) SQ Identifies the Series containing the referenced SR ALWAYS AUTO >>Referenced SOP Sequence (0008,1199) SQ SOP Instance UID for SR Series in the study ALWAYS AUTO >>> Referenced SOP Class (0008,1150) UI Comprehensive SR SOP Class 1.2.840.10008.5.1.4.1.1.88.33 ALWAYS AUTO >>> Referenced SOP Instance UID (0008,1155) UI SOP Instance UID of the preceding SR in the study...
Page 86
Table 9.26 SR DOCUMENT CONTENT MODULE OF CREATED COMPREHENSIVE SR SOP INSTANCES Attribute Name Tag VR Value Presence of Value Source Content Template Sequence (0040,A504) SQ ALWAYS AUTO >Template Identifier (0040,DB00) CS The Root Content Item identifies TID 5000 (OB - GYN), 5100 (Vascular). 5200 (Echo), TID 5220 or 995300 (Ped Echo) , TID 995400 (Small Parts) ALWAYS AUTO >Mapping Resource (0008,0105) CS DCMR ALWAYS AUTO Content Sequence (0040,A730) SQ ALWAYS...
Page 87
Attribute Name Tag VR Value Presence of Value Source Graphic Data (0070,0022) Order set of Column \ Row pairs defining positions in a reference image ANAP AUTO Graphic Type (0070,0023) Polyline ANAP AUTO Numeric Measurement Macro Template ID 5000 for OB-GYN Template ID 5100 for Vascular Template ID 5200 for Adult Echo Template ID 5220 for Ped,Fetal,Congenital Template ID 995300 for private Ped Template ID 995400 for private Small Parts ALWAYS AUTO Code Macro...
Page 88
Table 9.28 ATTRIBUTE MAPPING BETWEEN MODALITY WORKLIST, IMAGE AND MPPS Modality Worklist Image IOD MPPS IOD Patient’s Name Patient’s Name Patient’s Name Patient ID Patient ID Patient ID Patient’s Birth Date Patient’s Birth Date Patient’s Birth Date Patient’s Sex Patient’s Sex Patient’s Sex Patient’s W eight Patient’s W eight Referring Physician’s Name Referring Physician’s Name ---- ---- Scheduled Step Attributes Sequence Study Instance UID Study Instance UID >Study Instance UID...
Page 89
9.1.5 Attribute Anonymization The EPIQ/Affiniti supports basic anonymization in that a set of identifying DICOM attributes that are stored to media wil l be either removed or replaced with non- identifying data, according to the HIPAA guidelines for anonymization. The option to de- identify is available at the time of export for the manual send to media workflows. Table 9.29 contains a list of attributes containing patient identification and how EPIQ/Affiniti processing the attribute...
Page 90
Attribute Name Tag Delete / Replace? Patient’s W eight (0010,1030) Replace Pregnancy Status (0010,10C0) Replace Medical Alerts (0010,2000) Delete Alergies (0010,2110) Delete Ethnic Group (0010,2160) Delete Additional Patient History (0010,21B0) Delete Patient Comments (0010,4000) Delete Device Serial Number (0018,1000) Delete Protocol Name (0018,1030) Delete Study Instance UID (0020,000D) Replace Series Instance UID (0020,000E) Replace Study ID (0020,0010) Delete...