Page 21
21 Spot and Multiscreen Monitor The WJ-FS616C video multiplexer can be connected to two monitors. The monitor displays the video signal according to the connection made, as shown below. Spot Monitor:The monitor that is connected to the SPOT OUT connector on the rear of the video multi- plexer. It only displays the camera input in single spot or single sequence. Displaying the VCR playback is disabled. Multiscreen Monitor:The monitor that is connected to the MULTISCREEN OUT connector on the rear of the...
Page 22
22 Connection with the Time Lapse VCR Connect the time lapse VCR as shown in the example below. 19 201 ALARM/REMOTE 37 CAMERA SW INREC OUT PLAY IN VIDEO S–VIDEO S–VIDEO VIDEO VIDEO IN CAMERA SW OUTGND S-VIDEO AUDIOVIDEO OUT 12345678910111213141516 8 9 28 26 13 4 7 16 1234 ALARM IN COMALARM RESET INALARMRECOVER OUT 5678 ALARM OUT 1 SHOT IN TAPE END OUT 9101112 WARNING OUT HUMID OUT REC REVIEWOUT 13141516 SERIES REC IN TIME ADJUST INTIMEADJUST OUT COMREC OUT SERIES REC OUT Video Multiplexer...
Page 24
24 SETUP MENU The setup menu provides a way for controlling functions that are not available by a direct operation. Displaying the SETUP MENU To display the setup menu follow the procedure below. 1. Confirm that the camera and peripherals are connected correctly and securely and all components are turned on. 2. Press the [SET UP/ESC] button for 2 seconds or more. The WJ-FS616C SETUP MENU appears on the screen of the spot and multiscreen monitors as shown in the figure. The following buttons are valid...
Page 25
25 Programming Setup Menu As shown below, the SETUP MENU has nine main submenus: Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup, System Setup, Camera Download, Camera Upload and All Reset. Six of these submenus; Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup and System Setup are further divided into additional submenus. The (❋) mark indicates that the item has a submenu for more detailed...
Page 26
26 4. To clear all alarm records, press the Aor Bbutton to select CLEAR where the cursor is positioned, then press the [HOME/SET] button. 5. Press the [SET UP/ESC] button to return to the previous ALARM SETUP menu. Alarm Schedule This item lets you enable or disable the system alarm func- tion. 1. Move the cursor to the ALM SCHEDULE parameter by pressing the Cor Dbutton. 2. Select ON or OFF by pressing the Aor Bbutton. ON:Enables system alarm function. OFF:Disables system alarm function. The factory...
Page 27
27 Camera Site Alarm This item lets you enable or disable the camera site alarm function. 1. Move the cursor to the CAM SITE ALM parameter by pressing the Cor Dbutton. 2 Select ON or OFF by pressing the Aor Bbutton. ON:Enables camera site alarm function. OFF:Disables camera site alarm function. The factory default setting is OFF. Note:To use this function, the WV-PB6164 Data Multiplex Boards must be installed in the video mul- tiplexer. Video Loss Alarm This item lets you enable or disable the alarm...
Page 28
28 Alarm Mode on the Multiscreen Monitor This item lets you select the mode for displaying an alarm on the multiscreen monitor. 1. Move the cursor to the ALM MODE-MLT parameter. 2. Select the desired mode. ALM-LINK:Switches screen to the camera image of the corresponding channel with an alarm title super- imposed. ALM-IND:Retains the camera image currently select- ed. An alarm title appears overlapped on the camera image. If no camera is currently selected the alarm title does not appear. The factory...
Page 29
29 Clock Display This item lets you enable or disable the clock display on the multiscreen monitor. 1. Move the cursor to the CLOCK DISPLAY parameter. 2. Select either ON or OFF. ON:Enables clock display on the monitor screen. OFF:Disables clock display on the monitor screen. The factory default setting is ON. Still Display This item lets you enable or disable display of the subtitle “STILL” on the multiscreen monitor when the image is in the freeze mode. 1. Move the cursor to the STILL DISPLAY...
Page 30
30 Secret View When the camera image is displayed in the spot mode on the spot monitor, the multiscreen monitor is enabled to skip the step in sequence or display a blackout in multiscreen for that selected channel image. This function is called Secret View and the item lets you enable or disable this function on the multiscreen monitor. 1. Move the cursor to the SECRET VIEW parameter. 2. Select either ON or OFF. OFF:Disables the secret view function. ON:Enables the secret view function. The factory...