21 Spot and Multiscreen Monitor The WJ-FS616C video multiplexer can be connected to two monitors. The monitor displays the video signal according to the connection made, as shown below. Spot Monitor:The monitor that is connected to the SPOT OUT connector on the rear of the video multi- plexer. It only displays the camera input in single spot or single sequence. Displaying the VCR playback is disabled. Multiscreen Monitor:The monitor that is connected to the MULTISCREEN OUT connector on the rear of the video multiplexer. It can displays the camera input in multiscreen mode (4, 7, 9, 10, 13, 16 screen segments). It also displays the VCR playback images. In addition, the video multiplexer can be connected to the other additional monitor, if the system is required. Connect the monitor (substituted for VCR) to the REC OUT connector on the rear of the video multiplexer. Multiscreen 2 Monitor:It has functions as same as the multiscreen monitor. Pressing the MULTISCREEN button alternately selects multiscreen output or multiscreen 2 output. The indicator blinks to indicate that the multiscreen 2 output is selected. MONITORS AND DISPLAYS SPOTREC OUT MULTISCREEN OUTOUT I NS–VIDEO VIDEO Video Multiplexer WJ-FS616C S–VIDEO VIDEO ON OFFPOWERON OFFPOWER
22 Connection with the Time Lapse VCR Connect the time lapse VCR as shown in the example below. 19 201 ALARM/REMOTE 37 CAMERA SW INREC OUT PLAY IN VIDEO S–VIDEO S–VIDEO VIDEO VIDEO IN CAMERA SW OUTGND S-VIDEO AUDIOVIDEO OUT 12345678910111213141516 8 9 28 26 13 4 7 16 1234 ALARM IN COMALARM RESET INALARMRECOVER OUT 5678 ALARM OUT 1 SHOT IN TAPE END OUT 9101112 WARNING OUT HUMID OUT REC REVIEWOUT 13141516 SERIES REC IN TIME ADJUST INTIMEADJUST OUT COMREC OUT SERIES REC OUT Video Multiplexer WJ-FS616C Time Lapse VCR VCR CONTROLR2–232C REMOTE OUT See Notes Notes: • Before controlling the VCR through the REMOTE OUT connector: 1. Power up the video multiplexer and the VCR simul- taneously. 2. Connect the video signal cable between the multi- plexer and the VCR. • The REMOTE OUT performs similarly to the AG-A11 Remote Controller for Time Lapse VCRs.• To control the VCR remotely, connect it with either the RS-232C Port or REMOTE OUT Connector. • When using the REMOTE OUT Connector for controlling the VCR remotely, reverse play and recording duration operations are disabled due to system designation. • The VCRs shown below can be controlled remotely. AG-RT600A, AG-TL500 AG-6124 AG-6740* AG-TL500 (*Optional interface adapter is required)
24 SETUP MENU The setup menu provides a way for controlling functions that are not available by a direct operation. Displaying the SETUP MENU To display the setup menu follow the procedure below. 1. Confirm that the camera and peripherals are connected correctly and securely and all components are turned on. 2. Press the [SET UP/ESC] button for 2 seconds or more. The WJ-FS616C SETUP MENU appears on the screen of the spot and multiscreen monitors as shown in the figure. The following buttons are valid in the SETUP MENU: UP (D):Moves the cursor upward. DOWN (C):Moves the cursor downward. LEFT (A):Moves the cursor to the left, or selects the mode or parameter forwardly. RIGHT (B):Moves the cursor to the right, or selects the mode or parameter reversely. HOME/SET:Executes the selections and displays a submenu for an item with the (❋) mark. STILL (-):Selects the mode or parameter. EL-ZOOM (+):Selects the mode or parameter. FUNCTION:Selects the next page. This manual uses the above ( ) symbols hereafter for following description.3. Press the [SET UP/ESC] button to execute the currently highlighted setting and return to the previous menu in the SETUP MENU. 4. To finalize the setting and return to normal viewing, press the [SET UP/ESC] button for 2 seconds or more while the SETUP MENU is displayed. Note:If alarm is activated during the setup operation, the SETUP MENU disappears and the display returns to the normal images. Any settings previous- ly made take effect, even if the [SET UP/ESC] but- ton was not pressed. WJ-FS616C SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * SET UP/ESC LEFT RIGHT UP DOWNHOME/SET EL-ZOOMSTILL FUNCTION
25 Programming Setup Menu As shown below, the SETUP MENU has nine main submenus: Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup, System Setup, Camera Download, Camera Upload and All Reset. Six of these submenus; Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup and System Setup are further divided into additional submenus. The (❋) mark indicates that the item has a submenu for more detailed setups. SETUP MENU ALARM SETUPAlarm Recall Alarm Schedule Camera Site Alarm Camera Switching Signal Loss Alarm Video Loss Alarm Alarm Display on the Monitors Alarm Output Duration Alarm Buzzer Duration Alarm Mode on Multiscreen Monitor Camera Upload All Reset Page 26 Alarm Mode on Spot Monitor Dynamic Recording Alarm Recording Mode Camera Title Display Clock Display Still Display Border Display Camera Display Position Secret View Sequence Mode Camera Title Display Clock Display Camera Title Display Clock Display Dynamic Recording Recording Mode Camera Display Position Sequence Mode Clock Setup Clock Display Position Camera Title Setup Camera Title Display Position Sequence Setup Lock Mode Cable Compensation/VD2/Data Alarm Terminal Setup Playback Mode Data Mode RS-232C Mode Communication Port Setup VCR Input Select Daisy Mode Unit Address Password Camera Download MULTISCREEN OUTPUT SETUP SPOT OUTPUT SETUP RECORD OUTPUT SETUP MULTISCREEN 2 OUTPUT SETUP SYSTEM SETUP Page 29 Page 31 Page 32 Page 34 Page 36 Page 45 Page 45 Page 46 Sequence Timing (Multiscreen) Sequence Timing (Spot)
26 4. To clear all alarm records, press the Aor Bbutton to select CLEAR where the cursor is positioned, then press the [HOME/SET] button. 5. Press the [SET UP/ESC] button to return to the previous ALARM SETUP menu. Alarm Schedule This item lets you enable or disable the system alarm func- tion. 1. Move the cursor to the ALM SCHEDULE parameter by pressing the Cor Dbutton. 2. Select ON or OFF by pressing the Aor Bbutton. ON:Enables system alarm function. OFF:Disables system alarm function. The factory default setting is OFF. 3. To set the timer, press the [HOME/SET] button while the cursor is positioned on ON. The cursor moves to the timer editing area. 4. Press the Cor Dbutton to move the cursor to the desired position, then adjust the time when the alarm is to be activated by pressing the Aor Bbutton. Notes: • If the same time is set for start and stop time, the alarm is always enabled. • You can set the timer to extend into the next day, for example, 22:00 - 6:00. 5. Press the [SET UP/ESC] button to move the cursor to ON position. ALARM SETUP The procedure described below let you set the modes when an alarm is received. Move the cursor to ALARM SETUP in the SETUP MENU by pressing the Cor Dbutton and then press the [HOME/SET] button. The ALARM SETUP menu as shown in the figure appears on the monitor screen. Alarm Recall There are 100 alarm records stored in chronological order in 10 pages of table. The tables also indicate the alarm mode. 1. Move the cursor to ALM RECALL by pressing the Cor Dbutton and then press the [HOME/SET] button. The ALARM RECALL table appears on the monitor screen. The table lists the activated alarm modes (ALM-MODE) as follows: TRM ✽✽: Interface Alarm CH-LOSS:Video Input Signal Loss Alarm SITE:Camera Site Alarm PC ✽: PC Command Alarm 2. Press the Dbutton to select the next page of the table. 3. Press the Cbutton to back up to the previous page of the table. ALARM SETUP ALM RECALL * ALM SCHEDULE OFF CAM SITE ALM OFF VIDEO LOSS ALM ON SW-LOSS ALM OFF ALM DISPLAY ON ALM OUTPUT DUR 2SEC ALM BUZZER DUR 2SEC ALM MODE-MLT ALM-IND DWELL TIME 2SEC ALM MODE-SPT ALM-SPOT DYNAMIC REC OFF ALM REC MODE MODE0 REAL ALARM RECALL 1 OF10 NO. DATE TIME CAM ALM-MODE 10. JAN 1. 97 12:00:00 16CH TRM 12 9. DEC 12. 96 4:00:00 10CH SITE 8. DEC 12. 96 3:00:00 8CH SITE 7. DEC 12. 96 2:00:00 7CH SITE 6. DEC 12. 96 1:00:00 6CH TRM 1 5. DEC 11. 96 15:00:00 5CH TRM 5 4. DEC 11. 96 14:00:00 4CH TRM 14 3. DEC 11. 96 13:00:00 3CH TRM 7 2. DEC 11. 96 12:00:00 2CH CH-LOSS 1. DEC 11. 96 12:00:00 1CH CH-LOSS DISPLAY ( )NEXT ( )PRE ALARM SETUP ALM RECALL * ALM SCHEDULE ON 0:00- 0:00 CAM SITE ALM OFF VIDEO LOSS ALM ON SW-LOSS ALM OFF ALM DISPLAY ON ALM OUTPUT DUR 2SEC ALM BUZZER DUR 2SEC ALM MODE-MLT ALM-IND DWELL TIME 2SEC ALM MODE-SPT ALM-SPOT DYNAMIC REC OFF ALM REC MODE MODE0 REAL
27 Camera Site Alarm This item lets you enable or disable the camera site alarm function. 1. Move the cursor to the CAM SITE ALM parameter by pressing the Cor Dbutton. 2 Select ON or OFF by pressing the Aor Bbutton. ON:Enables camera site alarm function. OFF:Disables camera site alarm function. The factory default setting is OFF. Note:To use this function, the WV-PB6164 Data Multiplex Boards must be installed in the video mul- tiplexer. Video Loss Alarm This item lets you enable or disable the alarm function when the camera video signal is lost. 1. Move the cursor to the VIDEO LOSS ALM parameter. 2 Select either ON or OFF. ON:Enables alarm function when video loss is detect- ed. OFF:Disables alarm function when video loss is detect- ed. The factory default setting is ON. Camera Switching Pulse Loss Alarm This item lets you enable or disable alarm display (SW LOSS) on the monitor screen when the camera switching pulse is lost. 1. Move the cursor to the SW-LOSS ALM parameter. 2. Select either ON or OFF. ON:Enables alarm display on the monitor screen. OFF:Disables alarm display on the monitor screen. The factory default setting is OFF. Alarm Display on the Monitors This item lets you enable or disable alarm display on the spot and multiscreen monitors. 1. Move the cursor to the ALM DISPLAY parameter. 2. Select either ON or OFF. ON:Enables alarm display on the Monitors. OFF:Disables alarm display on the Monitors. The factory default setting is ON. Alarm Output Duration This item lets you select the output duration of the alarm signal from the ALARM/REMOTE port. The alarm is automatically reset after the programmed duration has passed. 1. Move the cursor to the ALM OUTPUT DUR parameter. 2. Select the desired duration. 1SEC - 5MIN:Selects an alarm duration between 1 second and 5 minutes. EXT:Alarm output continues until the ALARM RESET button is pressed or the external alarm recover sig- nal is received from the ALARM/REMOTE port. The factory default setting is 2 SEC. Alarm Buzzer Duration This item lets you select the ringing duration of the built-in alarm buzzer when an alarm is activated. 1. Move the cursor to the ALM BUZZER DUR parameter. 2. Select the desired duration. OFF:Disables alarm buzzer, regardless of an incoming alarm. 1SEC - 5 MIN:Selects buzzer duration between 1 sec- ond and 5 minutes. EXT:Alarm buzzer continues to beep until the ALARM RESET button is pressed or the external alarm recover signal is received from the ALARM/ REMOTE port. The factory default setting is 2 SEC.
28 Alarm Mode on the Multiscreen Monitor This item lets you select the mode for displaying an alarm on the multiscreen monitor. 1. Move the cursor to the ALM MODE-MLT parameter. 2. Select the desired mode. ALM-LINK:Switches screen to the camera image of the corresponding channel with an alarm title super- imposed. ALM-IND:Retains the camera image currently select- ed. An alarm title appears overlapped on the camera image. If no camera is currently selected the alarm title does not appear. The factory default setting is ALM-IND. 3. When ALM-LINK is selected for the parameter, then the cursor can be moved to the DWELL TIME parameter. Dwell Time for Alarm Sequence If more than one alarm is activated when ALM-LINK is selected, the respective camera images are displayed in quad mode on the multiscreen monitor. From the fifth alarm on, the images are displayed sequen- tially in quad mode. This item lets you set the dwell time for the alarm sequence. 1. Move the cursor to the DWELL TIME parameter. 2. Select the desired dwell time. 1SEC - 30SEC:Selects a dwell time between 1 second and 30 seconds. The factory default setting is 2 SEC. Alarm Mode on the Spot Monitor This item lets you select the mode for displaying an alarm on the spot monitor. 1. Move the cursor to the ALM MODE-SPT parameter. 2. Select the desired mode. ALM-SPOT:The camera image that has activated the alarm is displayed in single spot mode. If multiple alarms are activated, the monitor displays the camera image that has activated the alarm most recent. ALM-IGNORE:Ignores alarms activation and retains the camera image currently selected. The factory default setting is ALM-SPOT. Dynamic Recording In this mode, the camera image of the channel on which the alarm was activated is recorded preferentially over other video inputs. This item lets you enable or disable dynamic recording mode for recording on videotape. 1. Move the cursor to the DYNAMIC REC parameter. 2. Select either ON or OFF. ON:Enables dynamic recording. OFF:Disables dynamic recording. The factory default setting is OFF Alarm Recording Mode This item lets you select the mode for recording an alarm. Refer to Recording Mode Setup on page 33 for further details. 1. Move the cursor to the ALM REC MODE parameter. 2. Select the desired recording mode. MODE 0:Normal Recording MODE 1-8:Time lapse mode without camera switching pulse. MODE 9:Time lapse mode with camera switching pulse. The factory default setting is MODE 0. 3. After completed the setting, press the [SET UP/ESC] button to return to the previous WJ-FS616C SETUP
29 Clock Display This item lets you enable or disable the clock display on the multiscreen monitor. 1. Move the cursor to the CLOCK DISPLAY parameter. 2. Select either ON or OFF. ON:Enables clock display on the monitor screen. OFF:Disables clock display on the monitor screen. The factory default setting is ON. Still Display This item lets you enable or disable display of the subtitle “STILL” on the multiscreen monitor when the image is in the freeze mode. 1. Move the cursor to the STILL DISPLAY parameter. 2. Select either ON or OFF. ON:Enables display of the subtitle “STILL” on the moni- tor screen. OFF:Disables display of the subtitle “STILL” on the monitor screen. The factory default setting is ON. Border Display This item lets you enable or disable the display of borders that divide the screen of the multiscreen monitor, or selects a border color. 1. Move the cursor to the BORDER parameter. 2. Select the desired mode or color. WHITE:White Border GRAY:Gray Border BLACK:Black Border OFF:No Border The factory default setting is WHITE. The procedure described below let you determine the dis- play mode of the multiscreen monitor. Move the cursor to MULTI OUTPUT SETUP in the SETUP MENU, and then press the [HOME/SET] button. The MULTI OUTPUT SETUP menu appears on the mon- itor screen as shown in the figure. Camera Title Display This item lets you enable or disable display of the camera title on the multiscreen monitor. 1. Move the cursor to the TITLE DISPLAY parameter. 2. Select either ON or OFF. ON:Enables display of the camera title on the monitor screen. OFF:Disables display of the camera title on the monitor screen. The factory default setting is ON. MULTISCREEN OUTPUT SETUP MULTI OUTPUT SETUP TITLE DISPLAY ON CLOCK DISPLAY ON STILL DISPLAY ON BORDER WHITE DISPLAY POSITION * SEQUENCE MODE SEQ2 SECRET VIEW OFF WJ-FS616C SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT *
30 Secret View When the camera image is displayed in the spot mode on the spot monitor, the multiscreen monitor is enabled to skip the step in sequence or display a blackout in multiscreen for that selected channel image. This function is called Secret View and the item lets you enable or disable this function on the multiscreen monitor. 1. Move the cursor to the SECRET VIEW parameter. 2. Select either ON or OFF. OFF:Disables the secret view function. ON:Enables the secret view function. The factory default setting is OFF. 3. After finishing the setting, press the [SET UP/ESC] but- ton to return to the previous SETUP MENU. Camera Display Position Setting This item lets you assign the position where the camera image will be displayed on the multiscreen monitor. 1. Move the cursor to DISPLAY POSITION, and then press the [HOME/SET] button. The table shown in the figure appears on the monitor screen. 2. Move the cursor to the desired channel number by pressing the Cor Dbutton. 3. Select the numbers of the cameras to be displayed by pressing the Aor Bbutton. The images of the selected cameras are displayed one after another on the monitor screen. Note:The number can be assigned directly by press- ing the Camera Number (1 – 16) buttons. 4. Press the [SET UP/ESC] button to return to the previous MULTI OUTPUT SETUP menu. Note:This operation only affects the camera display positions. It has no effect on the camera channel, recording order or sequence order. Sequence Mode This item lets you select the sequence pattern for display on the multiscreen monitor. Refer to Sequence Setup on page 37 for further details. 1. Move the cursor to the SEQUENCE MODE parameter. 2. Select the desired sequence mode. SEQ1:Spot Sequence SEQ2:Multi Sequence SEQ3:Multi Sequence The factory default setting is SEQ2. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16