72 3. Press the [ZOOM] button to adjust the lens zoom to achieve the desired image while observing the active monitor. Press this button to the [TELE] position to optically bring an object closer. Pressing to the [WIDE] position has the reverse effect. 4. Press the [IRIS CLOSE/OPEN] buttons to close/open the lens iris. Adjust the lens iris by pressing these but- tons to obtain the proper image exposure. Pressing these buttons at the same time will reset the lens iris to the factory default setting. Pan/Tilt Control (Manual Operation) 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. Move the joystick to move the pan/tilt head in the desired direction. If the joystick is positioned in between UP and RIGHT, the pan/tilt head moves diagonally upward and to the right. The moving speed of the pan/tilt head depends on the tilt of the joystick. Pan/Tilt Control (Preset Operation) The following function requires the use of cameras equipped with the specific feature. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. Press the [PRE-POSI] button, then select the preset position number by pressing the Numeric keys. Camera Control Function The camera control is only available while the camera image is displayed in single spot on the selected monitor screen. Note:When controlling the camera with multiplexed control data by connecting a coaxial cable, you should install the optional WV-PB6164 Data Multiplex Board in the video multiplexer. Camera Selection 1. Select an either spot or multiscreen monitor by pressing the [F2] or [F1] button on the controller. 2. Select the camera mode (VCR off) by pressing the [F4] button on the controller. 3. Select the desired camera number by pressing the Numeric keys, then press the [CAM(SET)] key. The selected camera image is displayed in single spot on the active monitor screen. Controlling Camera Site Accessories For controlling camera site accessories, normally combina- tion camera equipped with the specific feature or a speci- fied receiver are required to utilize these functions. Lens Control Confirm that the specified lens with power zoom/focus func- tions is mounted on the camera. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. Press the [FOCUS] button to adjust the lens focus to achieve a sharply focused image while observing the active monitor. If the specified camera with auto focus feature is used in the system, you can adjust the lens focus automati- cally by pressing the [AF] button. FOCUS NEAR FARAF ZOOM TELE WIDE CLOSE OPENIRIS PRE- POSI 123 456 789 MON CAM UNIT/ESC SET0

73 3. Select the desired item by moving the joystick UP or DOWN, and then select the desired mode by moving the joystick LEFT or RIGHT. 4. Press the [CAM(SET)] button to execute the setting or enter a submenu. 5. Press the [F3] button to reset the selected item parame- ter, or press the [F4] button to reset all functions to the factory default setting. 6. Press the [MON(UNIT/ESC)] button to execute the set- ting and returns to the previous setup menu. 7. Press the [CAMERA SET OFFB] button to exit from the setup mode or menu. Note:Refer to the operating instructions of the selected camera for further details. Caution:Camera addresses are important for RS-485 type cameras. • Do not use addresses other than 1 through 16 for individual cameras. (“17” is not allowed) • Do not set a single address for more than one cam- era in an RS-485 chain. •Simplified preset position setting The preset position can be set by a simplified proce- dure. The following function requires the use of cameras equipped with the specific feature. 1. Press the [ALT] button while the position setting menu is displayed on the active monitor. 2. Move the joystick to move the pan/tilt head in the desired direction. 3. Press the [FOCUS] or [ZOOM] button to adjust the lens to achieve the desired image. 4. Press the [ALT] button again to restore the joystick’s cursor control function. Caution:If camera setup is started with the buttons on the camera, all settings must also be made with buttons on the camera’s. If camera setup is started with a controller, all e set- tings must be made with the controller. 3. Press the [CAM(SET)] key to move the pan/tilt head to the preset position on the active monitor. Pan/Tilt Control (Home Position) The following function requires the use of cameras equipped with the specific feature. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. Press the [HOME/–] button to move the camera to the home position on the active monitor. Pan/Tilt Control (Auto Panning ) The following function requires the use of cameras equipped with the specific feature. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. Press the [AUTO/+] button to activate the auto panning function. 3. To cancel the auto panning function, move the joystick controller in the desired direction. Note:When using the combination cameras with auto panning feature, make sure that the LOCAL/ REMOTE setting is set to LOCAL at the camera site. If REMOTE is selected, the panning movement is retained for only one minute. Camera Setup The following function requires the use of cameras equipped with the specific feature. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. Press the [CAMERA SET ONA] button to gain access to the camera setup menu on the active monitor. HOME/– AUX1 AUTO/+ AUX2 F3F4F2F1 U01 C01 CamSet Up RES A.RES T/L MODE SET UP PLAY REV CAMERA SET ONCAMERA SET OFF

74 Auxiliary Control The following function is available only with a system that includes WV-RC100 or WV-RC150 Receivers. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. While the ALT indicator is on, press the [HOME/–] or [AUTO/+] button to toggle the user’s auxiliary switch in the receiver on and off. Note:The auxiliary control is not available while operat- ing the zoom or pan/tilt head. Alarm Control Function Alarm Suspension This function disables activation of the alarm link and instead enables storing of any alarm activated in the alarm log. It is used to suspend the alarm link during camera setup. To suspend the alarm: 1. Press the [RESET] and [EL-ZOOM] buttons at the time for 2 seconds or more to suspend the alarm. The indicator in the RESET button lights. 2. Press the [RESET] button to reset the alarm suspension. The indicator in the RESET button goes off. ALTHOME/– AUX1AUX2 AUTO/+ RESETEL- ZOOM ALL FS RESET

75 The system shown below is an example of the expansion capabilities of the WJ-FS616C video multiplexer. Up to four video multiplexers can be connected to expand the camera inputs. SYSTEM EXPANSION 481216 371115 261014 15913 PUSH OPEN16POWERLOCKON OFF ALARMMULTI SCREENMULTISCREENSELECT RESET SPOT SEQUENCE VCR CAMCAMERA/PRESET P O S I T I O N Video Data RS-485 Spot In Time Lapse VCR System Controller WV-CU550C Spot Monitor Live Main: 1-16ch Local: 1-16chMultiscreen Monitor Live 1-16ch Playback 1-16ch RS-232C/Wired AUXAlarm 123456789MON CAM0System Controller for WJ-FS616 616 F3F4F2F1 Camera 1 -16Main Site (Unit 1) 481216 371115 261014 15913 PUSH OPEN16POWERLOCKON OFF ALARMMULTI SCREENMULTISCREENSELECT RESET SPOT SEQUENCE VCR CAMCAMERA/PRESET P O S I T I O N Video Data RS-485 Video Multiplexer WJ-FS616C Time Lapse VCR Multiscreen Monitor Live 1-16ch Playback 1-16ch RS-232C/Wired AUXAlarm Camera 1 -16Local Site (Unit 2) Data RS-485Spot Out Video Multiplexer WJ-FS616C 32-Input System

76 Connections In this type of installation, only one video multiplexer is con- nected directly to the system controller by a control cable. The rest of the video multiplexers are connected to the sys- tem controller in a daisy-chain type connection. Refer to the connections and data port settings shown below. Notes: • Up to four video multiplexers can be daisy-chained to the system controller. • Unit numbers should be assigned in the order of connection, starting with the unit connected directly to the WV-CU550C system controller. • Sequence display is limited to the cameras con- nected to one multiplexer unit only. • It is recommended to set the LOCK switch to the ON position while making these connections. • For controlling more than 4 cameras, additional WV- BP6164 Data Multiplex Boards need to be installed in the video multiplexer. Operating Procedure To control the system, follow the procedure shown below. 1. Confirm that the camera and peripherals are connected correctly and firmly. 2. Turn on the power switches of all system components. 3. Confirm that the DAISY MODE parameter in the SYS- TEM SETUP menu is set to ON. 4. Select the unit number of the video multiplexer with the Numeric key, then press the [MON(UNIT/ESC)] key to activate the selected unit.For example, press the keys shown below. In this example, the image of camera 15 connected to the video multiplexer Unit 2 is displayed on the Spot Monitor connected to the video multiplexer Unit 1. 5. Operate the selected unit as described in the OPERAT- ING PROCEDURES. 6. Select another unit with the Numeric key, then press the [MON(UNIT/ESC)] key to activate the selected unit. Other Applications Application 1 The video signal looped through the SPOT IN connector can be displayed on the Spot Monitor. 1. Confirm that the DAISY MODE in the SYSTEM SETUP menu is set to OFF. 2. Select the unit number of the video multiplexer with the Numeric key, then press the [MON(UNIT/ESC)] key to activate the selected unit. 3. Press the [F2] button on the controller to select the spot monitor. 4. Press [ 0 ] then press the [CAM(SET)] key to display the video looped through the SPOT IN connector on the Spot Monitor. TEAM. OFF IN OUT OND ATA SPOTOUT I N TEAM. OFF IN OUT OND ATA SPOTOUT I N INOUTTERMON OFF DATA0123456789CONTROLLER UNIT NO. 1-8 Local Site Main Site Video Multiplexer WJ-FS616C Video Multiplexer WJ-FS616C 123 456 789 MO N C A M UNIT/ESC SET0 MO N C A M UNIT/ESC2 SET 15 Unit 2 VIDEO Unit 1 VIDEO

77 Application 2 The camera images in the Local Site (Unit 2) can be dis- played on the multiscreen monitor in the Main Site (Unit 1) by connecting a coaxial cable shown below. For Local Site • Confirm that the REC MODE SETUP in the REC OUTPUT SETUP menu (page 33) is set to MODE 0. If the another mode is set for the REC MODE SETUP, this application does not work properly. For Main Site • To display the camera images in the Local Site, operate the video multiplexer as displaying the playback image. However same functions are enabled displaying the playback image. Local SiteVideo Multiplexer REC OUT PLAY IN MULTISCREEN OUTVIDEO S–VIDEO S–VIDEO S–VIDEO VIDEO VIDEO Video Multiplexer Coaxial Cable RG-59/U less than 250m (800 ft) Main Site Multiscreen MonitorLive 1-16ch Playback 1-16ch

78 APPENDIX (02H) ( ) – – – – – – ( ) (3AH) ( ) – – – ( ) (03H) [STX] [Transmission Command] [:] [Error Code] [ETX] [STX] [Address] [;] [Transmission Command] [ETX] Code ASCII (02H) ( ) – – – – – – – – – – – – – – – – – ( ) (03H) [NAK] [e] Code ASCII (15H) This Appendix details the elements for communication between the Video Multiplexer and the personal computer. For BAUD RATE, DATA BIT, STOP BIT and PARITY settings, see page 42 COM PORT SETUP menu. Communication Protocol 1. Transmission Command The PC sends messages to operate the Multiplexer in the format shown below. Also refer to the command table shown later. A transmission message consists of [STX], [Address], [;], [Transmission Command], and [ETX]. [Address] is expressed as “ADuu,”where ‘uu’ is in the range of “00” through “16” in decimal form to identify the unit number of the Video Multiplexer. When using the RS-232C port to communicate with the PC, [Address] and [;] can be omitted. 2. Response Command The Multiplexer returns messages in reply to the PC’s messages with the following formats. (1) Reception completed When the reception was completed successfully, the Multiplexer sends back “ACK code, 06H”, followed by parameters. The response command is shown in the Command Table. Note:The Video Multiplexer returns [ACK] or [NAK] to the PC within 20 ms after the reception of [ETX] in a transmission mes- sage. (2) Reception error The Multiplexer sends back “NAK code, 15H”, followed by the parameters shown below. The Multiplexer then resets the reception buffer and enters waiting mode for the next message. Parameter “e” identifies the error status. [STX] [Address] [;] [Response Command] [ETX] Code ASCII (02H) ( ) – – – – – – – – – – – – – – – ( ) (03H) “e” value 1: Parity error 2: Data Over error 3: Framing error 4: Overrun error 5: Time Out error (3) Parameter error The Multiplexer returns “ACK code, 06H”, the transmission command that was not processed properly for some reason, followed by an error code as shown below. Error code ER001: Command invalid ER002: Parameter invalid ER301: Command legal but out of range ER302: Parameter legal but out of range Code ASCII

79 m=0Quad m=1 7 divide m=2 9 divide m=3 10 divide m=4 13 divide m=5 16 divide m= 1No. of divisions (+)m=DNo. of divisions (−) Item Item m=0 Manual Reset m=1 Auto Reset mm=00 - 16 Camera Number *00=Spot Input mm=01 - 16 Playback CH number Alarm InputResponse Command (ASCII) Command Table (1) Operation Control Transmission Command (ASCII)Parameter (ASCII) Monitor Select OMS : m OMSm=0 Spot Monitor m=1 Multiscreen Monitor m=2 Multiscreen 2 Monitor VCR/Camera Select OVC : m OVCm=0 Camera Mode m=1 VCR Mode Still ON/OFF OST : m : nn OSTm=0 Still OFF m=1 Still ON nn=00 All video channels specify nn=01 - 16 Camera Number Multiscreen Select OTC : m OTC Sequence OSQ : m OSQm=0 End Sequence m=1 Activate Sequence Electronic Zoom ON/OFFOZM : m OZMm=0 Zoom OFF m=1 Zoom ON Single Spot CH Select OCS : mm OCS Camera & Playback Display Playback CH SelectOVS : mm OVS Alarm Reset OAL : m OAL Alarm Log Clear OAR OAR None Sequence Mode SelectOSE : m OSEm=0 SEQ1 m=1 SEQ2 m=2 SEQ3 OAI : m OAIm=0 1CH Alarm : m=F 16CH Alarm (2) Mode Change Alarm Suspension MAD : m MADm=0 Alarm Suspension OFF m=1 Alarm Suspension ON Lock *1 MKL : m MKLm=0 Lock OFF m=1 Lock ON Setup MSU : m MSUm=0 End Setup m=1 Begin Setup Response Command (ASCII) Transmission Command (ASCII)Parameter (ASCII) Note:If a command has no parameter value, it is processed with the value under lined in the table. *1: The LOCK (key lock) command is used to prohibit operations on the panel of the Video Multiplexers and the System Controllers. After execution of this command, only the personal computer can operate the system.

80 Item Item Response Command (ASCII) Transmission Command (ASCII)Parameter (ASCII) DCR : mm mm=UU Move Upward mm=DD Move Downward mm=RR Move to Right mm=LL Move to Left mm=BB Move to lower layer mm=ES Move to upper layer Item decision (partial) mm=IC Select parameter (+) mm=DC Select parameter (–) mm=FF Select page mm=UR Move to Upper-Right mm=UL Move to Upper-Left mm=DR Move to Lower-Right mm=DL Move to Lower-Left *2 DCR (3) Cursor Control Cursor Movement Select Parameter *2 The parameter valid on the main unit setup menu is: mm=UU, DD, RR, LL, BB, ES, FF, IC, DC The parameter valid for zoom position move during electronic zooming is: mm=UU, DD, RR, LL, UR, UL, DR, DL (4) Status Inquiry Status Inquiry QOP Table below (19 kinds) NoneResponse Command (ASCII) Transmission Command (ASCII)Parameter (ASCII)

81 No. Examples of response Response Command (ASCII) Main Unit Information 1 @mPLSNcc Single Spot (Camera) 2 @mPLSZcc Single Spot + Electronic Zoom (Camera) 3 @mPLSScc Single Spot + Still (Camera) 4 @mPLSXcc Single Spot + Zoom + Still (Camera) 5 @mPLSMLa Multi Spot (+ Still) (Camera) 6 @mPLQNcc Spot Sequence (Camera) 7 @mPLQMLa Multi Sequence (Camera) 8 @mPLQZcc Spot Sequence + Zoom (Camera) 9 @mPVSNcc Single Spot (VCR) 10 @mPVSZcc Single Spot + Zoom (VCR) 11 @mPVSScc Single Spot + Still (VCR) 12 @mPVSXcc Single Spot + Zoom + Still (VCR) 13 @mPVSMLa Multi Spot (+ Still) (VCR) 14 @mPVQNcc Spot Sequence (VCR) 15 @mPVQMLa Multi Sequence (VCR) 16 @mPVQZcc Spot Sequence + Zoom (VCR) 17 @mPRSMLa Live & VCR Display (+ Still) 18 @mPE Setup Mode 19 @mPX Playback through m=0, 1, 2 Monitor Number (0 : Spot Monitor, 1 : Multiscreen Monitor, 2 : Multiscrren 2 Monitor ) P=N, A, D, F N : Normal A : Alarm D : Normal + Alarm Suspension F : Alarm + Alarm Suspension cc=01 - 16 Camera Number (00 (SPOT IN) is also possible when Spot Monitor (m=0)) is selected a = 0 - 6 According to the number of screen divisions. 0 : Quad 1 : 7 divide 2 : 9 divide 3 : 10 divide 4 : 13 divide 5 : 16 divide 6 : Single Spot