    Have a look at the manual Panasonic Video Multiplexer Wj Fs616c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							72
    3. Press the [ZOOM] button to adjust the lens zoom to
    achieve the desired image while observing the active
    monitor.
    Press this button to the [TELE] position to optically bring
    an object closer. 
    Pressing to the [WIDE] position has the reverse effect.
    4. Press the [IRIS CLOSE/OPEN] buttons to close/open
    the lens iris. Adjust the lens iris by pressing these but-
    tons to obtain the proper image exposure.
    Pressing these buttons at the same time will reset the
    lens iris to the factory default setting.
    Pan/Tilt Control (Manual Operation)
    1. Select the desired monitor and camera referring to the
    Camera Selection procedure described above.
    2. Move the joystick to move the pan/tilt head in the
    desired direction.
    If the joystick is positioned in between UP and RIGHT,
    the pan/tilt head moves diagonally upward and to the
    right.
    The moving speed of the pan/tilt head depends on the
    tilt of the joystick.
    Pan/Tilt Control (Preset Operation)
    The following function requires the use of cameras
    equipped with the specific feature.
    1. Select the desired monitor and camera referring to the
    Camera Selection procedure described above.
    2. Press the [PRE-POSI] button, then select the preset
    position number by pressing the Numeric keys.
    Camera Control Function
    The camera control is only available while the camera
    image is displayed in single spot on the selected monitor
    screen.
    Note:When controlling the camera with multiplexed control
    data by connecting a coaxial cable, you should install
    the optional WV-PB6164 Data Multiplex Board in the
    video multiplexer.
    Camera Selection
    1. Select an either spot or multiscreen monitor by pressing
    the [F2] or [F1] button on the controller.
    2. Select the camera mode (VCR off) by pressing the [F4]
    button on the controller.
    3. Select the desired camera number by pressing the
    Numeric keys, then press the [CAM(SET)] key.
    The selected camera image is displayed in single spot
    on the active monitor screen.
    Controlling Camera Site Accessories
    For controlling camera site accessories, normally combina-
    tion camera equipped with the specific feature or a speci-
    fied receiver are required to utilize these functions.
    Lens Control
    Confirm that the specified lens with power zoom/focus func-
    tions is mounted on the camera.
    1. Select the desired monitor and camera referring to the
    Camera Selection procedure described above.
    2. Press the [FOCUS] button to adjust the lens focus to
    achieve a sharply focused image while observing the
    active monitor.
    If the specified camera with auto focus feature is used
    in the system, you can adjust the lens focus automati-
    cally by pressing the [AF] button.
    FOCUS
    NEAR
    FARAF
    ZOOM
    TELE
    WIDE
    CLOSE OPENIRIS
    PRE-
    POSI
    123
    456
    789
    MON CAM
    UNIT/ESC SET0 
    						
    							73
    3. Select the desired item by moving the joystick UP or
    DOWN, and then select the desired mode by moving
    the joystick LEFT or RIGHT.
    4. Press the [CAM(SET)] button to execute the setting or
    enter a submenu.
    5. Press the [F3] button to reset the selected item parame-
    ter, or press the [F4] button to reset all functions to the
    factory default setting.
    6. Press the [MON(UNIT/ESC)] button to execute the set-
    ting and returns to the previous setup menu.
    7. Press the [CAMERA SET OFFB] button to exit from the
    setup mode or menu.
    Note:Refer to the operating instructions of the selected
    camera for further details.
    Caution:Camera addresses are important for RS-485
    type cameras.
    • Do not use addresses other than 1 through 16 for
    individual cameras. (“17” is not allowed)
    • Do not set a single address for more than one cam-
    era in an RS-485 chain.
    •Simplified preset position setting
    The preset position can be set by a simplified proce-
    dure.
    The following function requires the use of cameras
    equipped with the specific feature.
    1. Press the [ALT] button while the position setting menu
    is displayed on the active monitor.
    2. Move the joystick to move the pan/tilt head in the
    desired direction.
    3. Press the [FOCUS] or [ZOOM] button to adjust the lens
    to achieve the desired image.
    4. Press the [ALT] button again to restore the joystick’s
    cursor control function.
    Caution:If camera setup is started with the buttons on
    the camera, all settings must also be made with
    buttons on the camera’s.
    If camera setup is started with a controller, all e set-
    tings must be made with the controller. 3. Press the [CAM(SET)] key to move the pan/tilt head to
    the preset position on the active monitor.
    Pan/Tilt Control (Home Position)
    The following function requires the use of cameras
    equipped with the specific feature.
    1. Select the desired monitor and camera referring to the
    Camera Selection procedure described above.
    2. Press the [HOME/–] button to move the camera to the
    home position on the active monitor.
    Pan/Tilt Control (Auto Panning )
    The following function requires the use of cameras
    equipped with the specific feature.
    1. Select the desired monitor and camera referring to the
    Camera Selection procedure described above.
    2. Press the [AUTO/+] button to activate the auto panning
    function.
    3. To cancel the auto panning function, move the joystick
    controller in the desired direction.
    Note:When using the combination cameras with auto
    panning feature, make sure that the LOCAL/
    REMOTE setting is set to LOCAL at the camera site.
    If REMOTE is selected, the panning movement is
    retained for only one minute.
    Camera Setup
    The following function requires the use of cameras
    equipped with the specific feature.
    1. Select the desired monitor and camera referring to the
    Camera Selection procedure described above.
    2. Press the [CAMERA SET ONA] button to gain access
    to the camera setup menu on the active monitor.
    HOME/–
    AUX1
    AUTO/+
    AUX2
    F3F4F2F1
    U01 C01 CamSet Up
    RES A.RES
    T/L MODE
    SET UP
    PLAY REV
    CAMERA
    SET ONCAMERA
    SET OFF 
    						
    							74
    Auxiliary Control
    The following function is available only with a system that
    includes WV-RC100 or WV-RC150 Receivers.
    1. Select the desired monitor and camera referring to the
    Camera Selection procedure described above.
    2. While the ALT indicator is on, press the [HOME/–] or
    [AUTO/+] button to toggle the user’s auxiliary switch in
    the receiver on and off.
    Note:The auxiliary control is not available while operat-
    ing the zoom or pan/tilt head.
    Alarm Control Function
    Alarm Suspension
    This function disables activation of the alarm link and
    instead enables storing of any alarm activated in the alarm
    log.
    It is used to suspend the alarm link during camera setup.
    To suspend the alarm:
    1. Press the [RESET] and [EL-ZOOM] buttons at the time
    for 2 seconds or more to suspend the alarm.
    The indicator in the RESET button lights.
    2. Press the [RESET] button to reset the alarm suspension.
    The indicator in the RESET button goes off.
    ALTHOME/–
    AUX1AUX2
    AUTO/+
    RESETEL-
    ZOOM
    ALL  FS
    RESET 
    						
    							75
    The system shown below is an example of the expansion capabilities of the WJ-FS616C video multiplexer.
    Up to four video multiplexers can be connected to expand the camera inputs.
    SYSTEM EXPANSION
    481216
    371115
    261014
    15913
    PUSH   OPEN16POWERLOCKON
    OFF
    ALARMMULTI
    SCREENMULTISCREENSELECT
    RESET SPOT SEQUENCE
    VCR
    CAMCAMERA/PRESET   P O S I T I O N
    Video
    Data RS-485
    Spot In
    Time Lapse VCR
    System Controller
    WV-CU550C
    Spot Monitor
    Live
    Main: 1-16ch
    Local: 1-16chMultiscreen Monitor
    Live 1-16ch
    Playback 1-16ch
    RS-232C/Wired
    AUXAlarm
    123456789MON CAM0System Controller for WJ-FS616 616
    F3F4F2F1
    Camera 1 -16Main Site (Unit 1)
    481216
    371115
    261014
    15913
    PUSH   OPEN16POWERLOCKON
    OFF
    ALARMMULTI
    SCREENMULTISCREENSELECT
    RESET SPOT SEQUENCE
    VCR
    CAMCAMERA/PRESET   P O S I T I O N
    Video
    Data RS-485
    Video Multiplexer
    WJ-FS616C
    Time Lapse VCR
    Multiscreen Monitor
    Live 1-16ch
    Playback 1-16ch
    RS-232C/Wired
    AUXAlarm Camera 1 -16Local Site (Unit 2)
    Data
    RS-485Spot Out Video Multiplexer
    WJ-FS616C
    32-Input System 
    						
    							76
    Connections
    In this type of installation, only one video multiplexer is con-
    nected directly to the system controller by a control cable.
    The rest of the video multiplexers are connected to the sys-
    tem controller in a daisy-chain type connection.
    Refer to the connections and data port settings shown
    below.
    Notes:
    • Up to four video multiplexers can be daisy-chained
    to the system controller.
    • Unit numbers should be assigned in the order of
    connection, starting with the unit connected directly
    to the WV-CU550C system controller.
    • Sequence display is limited to the cameras con-
    nected to one multiplexer unit only.
    • It is recommended to set the LOCK switch to the
    ON position while making these connections.
    • For controlling more than 4 cameras, additional WV-
    BP6164 Data Multiplex Boards need to be installed
    in the video multiplexer.
    Operating Procedure
    To control the system, follow the procedure shown below.
    1. Confirm that the camera and peripherals are connected
    correctly and firmly.
    2. Turn on the power switches of all system components.
    3. Confirm that the DAISY MODE parameter in the SYS-
    TEM SETUP menu is set to ON.
    4. Select the unit number of the video multiplexer with the
    Numeric key, then press the [MON(UNIT/ESC)] key to
    activate the selected unit.For example, press the keys shown below.
    In this example, the image of camera 15 connected to
    the video multiplexer Unit 2 is displayed on the Spot
    Monitor connected to the video multiplexer Unit 1.
    5. Operate the selected unit as described in the OPERAT-
    ING PROCEDURES.
    6. Select another unit with the Numeric key, then press the
    [MON(UNIT/ESC)] key to activate the selected unit.
    Other Applications
    Application 1
    The video signal looped through the SPOT IN connector
    can be displayed on the Spot Monitor.
    1. Confirm that the DAISY MODE in the SYSTEM SETUP
    menu is set to OFF.
    2. Select the unit number of the video multiplexer with the
    Numeric key, then press the [MON(UNIT/ESC)] key to
    activate the selected unit.
    3. Press the [F2] button on the controller to select the spot
    monitor.
    4. Press [ 0 ] then press the [CAM(SET)] key to display the
    video looped through the SPOT IN connector on the
    Spot Monitor.
    TEAM.
    OFF IN OUT
    OND ATA
    SPOTOUT I N
    TEAM.
    OFF IN OUT
    OND ATA
    SPOTOUT I N
    INOUTTERMON OFF
    DATA0123456789CONTROLLER
    UNIT NO.
    1-8
    Local Site Main Site
    Video Multiplexer
    WJ-FS616C Video Multiplexer
    WJ-FS616C
    123
    456
    789
    MO N C A M
    UNIT/ESC SET0
    MO N C A M
    UNIT/ESC2
    SET
    15
    Unit 2
    VIDEO
    Unit 1
    VIDEO 
    						
    							77
    Application 2
    The camera images in the Local Site (Unit 2) can be dis-
    played on the multiscreen monitor in the Main Site (Unit 1)
    by connecting a coaxial cable shown below.
    For Local Site
    • Confirm that the REC MODE SETUP in the REC
    OUTPUT SETUP menu (page 33) is set to MODE 0.
    If the another mode is set for the REC MODE
    SETUP, this application does not work properly.
    For Main Site
    • To display the camera images in the Local Site,
    operate the video multiplexer as displaying the
    playback image.
    However same functions are enabled displaying the
    playback image.
    Local SiteVideo Multiplexer
    REC  OUT
    PLAY   IN
    MULTISCREEN OUTVIDEO S–VIDEO
    S–VIDEO S–VIDEO VIDEO VIDEO
    Video Multiplexer Coaxial Cable
    RG-59/U less than 250m (800 ft)
    Main Site
    Multiscreen MonitorLive 1-16ch
    Playback 1-16ch 
    						
    							78
    APPENDIX
    (02H)   (      ) – – – – – –  (      )   (3AH)   (      ) – – – (      )     (03H)
    [STX]     [Transmission Command]     [:]     [Error Code]     [ETX]
    [STX]   [Address] [;]   [Transmission Command]   [ETX] Code
    ASCII (02H)   (      ) – – – – – – – – – – – – – – – – – (      )   (03H)
    [NAK]   [e] Code
    ASCII (15H)
    This Appendix details the elements for communication between the Video Multiplexer and the personal computer. For BAUD
    RATE, DATA BIT, STOP BIT and PARITY settings, see page 42 COM PORT SETUP menu.
    Communication Protocol
    1. Transmission Command
    The PC sends messages to operate the Multiplexer in the format shown below. Also refer to the command table shown
    later. 
    A transmission message consists of [STX], [Address], [;], [Transmission Command], and [ETX]. [Address] is expressed as
    “ADuu,”where ‘uu’ is in the range of “00” through “16” in decimal form to identify the unit number of the Video Multiplexer.
    When using the RS-232C port to communicate with the PC, [Address] and [;] can be omitted.
    2. Response Command
    The Multiplexer returns messages in reply to the PC’s messages with the following formats.
    (1) Reception completed
    When the reception was completed successfully, the Multiplexer sends back “ACK code, 06H”, followed by parameters.
    The response command is shown in the Command Table.
    Note:The Video Multiplexer returns [ACK] or [NAK] to the PC within 20 ms after the reception of [ETX] in a transmission mes-
    sage. (2) Reception error
    The Multiplexer sends back “NAK code, 15H”, followed by the parameters shown below. The Multiplexer then resets the
    reception buffer and enters waiting mode for the next message. Parameter “e” identifies the error status.
    [STX]   [Address] [;]   [Response Command]   [ETX] Code
    ASCII (02H)   (      ) – – – – – – – – – – – – – – – (      )   (03H)
    “e” value 1: Parity error
    2: Data Over error
    3: Framing error
    4: Overrun error
    5: Time Out error
    (3) Parameter error
    The Multiplexer returns “ACK code, 06H”, the transmission command that was not  processed properly for some reason,
    followed by an error code as shown below.
    Error code ER001: Command invalid
    ER002: Parameter invalid
    ER301: Command legal but out of range
    ER302: Parameter legal but out of range Code
    ASCII 
    						
    							79
    m=0Quad m=1 7 divide
    m=2 9 divide m=3 10 divide
    m=4 13 divide   m=5 16 divide
    m=
    1No. of divisions (+)m=DNo. of divisions (−)
    Item Item
    m=0
    Manual Reset
    m=1 Auto Reset mm=00 - 16   Camera Number
    *00=Spot Input
    mm=01 - 16   Playback CH number
    Alarm InputResponse
    Command (ASCII)
    Command Table
    (1) Operation Control
    Transmission
    Command (ASCII)Parameter (ASCII)
    Monitor Select OMS : m OMSm=0
    Spot Monitor
    m=1 Multiscreen Monitor
    m=2 Multiscreen 2 Monitor
    VCR/Camera Select OVC : m OVCm=0
    Camera Mode
    m=1 VCR Mode
    Still ON/OFF OST : m : nn OSTm=0
    Still OFF
    m=1 Still ON
    nn=00
    All video channels specify
    nn=01 - 16   Camera Number
    Multiscreen Select OTC : m OTC
    Sequence OSQ : m OSQm=0
    End Sequence
    m=1 Activate Sequence
    Electronic Zoom
    ON/OFFOZM : m OZMm=0
    Zoom OFF
    m=1 Zoom ON
    Single Spot CH Select OCS : mm OCS
    Camera & Playback Display
    Playback CH SelectOVS : mm OVS
    Alarm Reset OAL : m OAL
    Alarm Log Clear OAR OAR None Sequence Mode
    SelectOSE : m OSEm=0
    SEQ1
    m=1 SEQ2
    m=2 SEQ3
    OAI : m OAIm=0
    1CH Alarm
    :
    m=F 16CH Alarm
    (2) Mode Change
    Alarm Suspension MAD : m MADm=0
    Alarm Suspension OFF
    m=1 Alarm Suspension ON
    Lock  *1 MKL : m MKLm=0
    Lock OFF
    m=1 Lock ON
    Setup MSU : m MSUm=0
    End Setup
    m=1 Begin Setup
    Response
    Command (ASCII) Transmission
    Command (ASCII)Parameter (ASCII)
    Note:If a command  has no parameter value, it is processed with the value under lined in the table.
    *1: The LOCK (key lock) command is used to prohibit operations on the panel of the Video Multiplexers and the System
    Controllers. After execution of this command, only the personal computer can operate the system. 
    						
    							80
    Item
    Item
    Response
    Command (ASCII) Transmission
    Command (ASCII)Parameter (ASCII) DCR : mm mm=UU Move Upward
    mm=DD Move Downward
    mm=RR Move to Right
    mm=LL Move to Left
    mm=BB Move to lower layer
    mm=ES Move to upper layer
    Item decision (partial)
    mm=IC Select parameter (+)
    mm=DC Select parameter (–)
    mm=FF Select page
    mm=UR Move to Upper-Right
    mm=UL Move to Upper-Left
    mm=DR Move to Lower-Right
    mm=DL Move to Lower-Left
    *2 DCR (3) Cursor Control
    Cursor Movement
    Select Parameter
    *2 The parameter valid on the main unit setup menu is:
    mm=UU, DD, RR, LL, BB, ES, FF, IC, DC
    The parameter valid for zoom position move during electronic zooming is:
    mm=UU, DD, RR, LL, UR, UL, DR, DL
    (4) Status Inquiry
    Status Inquiry QOP Table below (19 kinds) NoneResponse
    Command (ASCII) Transmission
    Command (ASCII)Parameter (ASCII) 
    						
    							81
    No. Examples of response
    Response Command (ASCII) Main Unit Information
    1 @mPLSNcc Single Spot (Camera)
    2 @mPLSZcc Single Spot + Electronic Zoom (Camera)
    3 @mPLSScc Single Spot + Still (Camera)
    4 @mPLSXcc Single Spot + Zoom + Still (Camera)
    5 @mPLSMLa Multi Spot (+ Still) (Camera)
    6 @mPLQNcc Spot Sequence (Camera)
    7 @mPLQMLa Multi Sequence (Camera)
    8 @mPLQZcc Spot Sequence + Zoom (Camera)
    9 @mPVSNcc Single Spot (VCR)
    10 @mPVSZcc Single Spot + Zoom (VCR)
    11 @mPVSScc Single Spot + Still (VCR)
    12 @mPVSXcc Single Spot + Zoom + Still (VCR)
    13 @mPVSMLa Multi Spot (+ Still) (VCR)
    14 @mPVQNcc Spot Sequence (VCR)
    15 @mPVQMLa Multi Sequence (VCR)
    16 @mPVQZcc Spot Sequence + Zoom (VCR)
    17 @mPRSMLa Live & VCR Display (+ Still)
    18 @mPE Setup Mode
    19 @mPX Playback through
    m=0, 1, 2 Monitor Number (0 : Spot Monitor, 1 : Multiscreen Monitor, 2 : Multiscrren 2 Monitor )
    P=N, A, D, F N : Normal    A : Alarm     D : Normal + Alarm Suspension      F : Alarm + Alarm Suspension
    cc=01 - 16 Camera Number (00 (SPOT IN) is also possible when Spot Monitor (m=0)) is selected
    a = 0 - 6 According to the number of screen divisions.
    0 : Quad    1 : 7 divide    2 : 9 divide    3 : 10 divide    4 : 13 divide    5 : 16 divide    6 : Single Spot 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Video Multiplexer Wj Fs616c Operating Instructions