Page 11

11
Note: This section describes the terminal mode. To operate
in the PS·Data mode, refer to p. 35.
■ On-screen Display (OSD)
Control
The procedure described below lets you determine the dis-
play parameters, such as camera title, clock and status, on
and off on the active monitor screen.
Before controlling each item, monitor selection is neces-
sary. (Refer to p. 3 Monitor Selection.)
●Displaying Each Item
1. Press the MENU button repeatedly until OSD On/Off
appears on the LCD.
2. Perform desired...

Page 12

12
2. Press the MENU button repeatedly until System Status
appears on the LCD.
3. Press the F1 button. 
The SYSTEM STATUS table will appear on the active
monitor as shown in the figure.
The columns in the table indicate the states as shown in the
figure.
MON:Monitor number
CAM:Logical camera number (01 to 99)
Recorder number (R0 to R4)*
– – indicates that no camera is being
selected. 
MODE:Lists the display mode on the
monitors.
SPOT:Spot mode
Tnn:Tour Sequence mode (nn is the
tour sequence number.)...

Page 13

13
■ Alarm History Table
There are 100 alarm records stored in chronological order
in 10 pages of tables.
1. Select the desired monitor. (Refer to p. 3 Monitor
Selection.)
2. Press the ALM RECALL button. Alarm Recall will
appear on the LCD. The ALARM HISTORY table will
appear on the active monitor as shown in the figure.
The columns in the table indicate the status as follows:
DATE:Lists the date and time when the alarm status
changes.
ALARM:Lists the alarm number (01 - 99).
EVENT:Lists the event when...

Page 14

14
MENU or WJ-SX150A Administrator Console. (Refer to
the operating instructions of matrix switcher.)
■Operation during an Alarm Mode
While an alarm mode is active, the following are available
from the system controller:
•Operating the camera with the alarm input (ACK)
•Resetting the alarm (ALM RESET/ALM ALL RESET)
•Suspending the alarm (ALM SUSPENDED)
■Operation of an Alarm-related
Camera (ACK)
You can operate the camera with the alarm input as follows:
1. Select a monitor which displays ALARM.
2. Press...

Page 15

15
■Resetting the Alarm Inputs
There are two alarm reset functions:
•Alarm reset (resetting the alarm inputs per monitor)
•Alarm all reset (resetting all the alarm inputs)
● Alarm Reset
1. Select a monitor which displays ALARM.
2. To reset the alarms, press the ALM RESET/ALM ALL
RESET button.
ALARMnn will disappear from the selected monitor.
When alarms have been reset from all the monitors, the
LCD display and indicators of system controllers will
work as follows for recovery.
•The LCD display will...

Page 16

16
MULTIPLEXER OPERATIONS MUX
Multiplexer board WJ-SXB151 is an optional board.
It enables multiscreen display, electronic zooming, still pic-
ture and multiscreen sequence.
It also enables the operation of Digital Disk Recorder WJ-
HD100 Series or time-lapse VCR, when connected to them.
Note:Before the use, it is necessary to install the
Multiplexer board in the matrix switcher and configure
the system through SETUP MENU and WJ-SX150A
Administrator Console. (Refer to the operating instruc-
tions of...

Page 17

17
6. Press the EL-ZOOM button. The area surrounded by
the + signs will be zoomed up.
7. To move the zoom area, move the 3D joystick.
8. To cancel the zooming, press the EL-ZOOM button.
Note:Still picture is not available while zooming is acti-
vated. 
Note:When a WJ-HD100 Series recorder or a Panasonic
time-lapse VCR is connected to the matrix switcher,
recording status will appear on the monitor in the
recorder mode. When the normal recording is activat-
ed, REC will appear on the monitor. When the...

Page 18

18
WJ-HD500 SERIES CONTROL (TERMINAL MODE)
Matrix switcher can control the following functions of Digital
Disk Recorder WJ-HD500 Series. The following is the pro-
cedure of WJ-HD500 Series SETUP MENU.
Notes:
•The following operating procedures are for the terminal
mode. If you are using a PS·Data system controller,
refer to p. 36.
•When a Multiplexer board is installed in the matrix
switcher, you can neither connect nor control a WJ-
HD500 Series recorder. You need to remove the board
from the matrix...

Page 19

19
■Controlling Digital Disk
Recorder WJ-HD500 Series
The following are the operating procedures of WJ-HD500
Series via system controller.
Note: Refer to the operating instructions of Digital Disk
Recorder WJ-HD500 Series for details.
●Recorder Mode
Before operating the recorder, it is necessary to enter the
recorder mode.
1. Select the desired monitor. (Refer to p. 3 Monitor
Selection.)
2. To select a recorder, press the corresponding numeric
button.
Recorder Numeric button
Master recorder 0 (You can...

Page 20

20
•To skip to the previous/next record during the play-
back, move the JogDial clockwise or counterclock-
wise. (Refer to the recorder’s operating instructions
for the description of record.) 
JogDial clockwise:Skips to the next record.
JogDial counterclockwise:Skips to the previous
record.
•To display the spot picture, press the numeric but-
ton corresponding to the desired camera number,
then press the CAM (SET) button. Then, the active
camera number will appear on the LCD.
•To resume the multiscreen...