Have a look at the manual Panasonic System Controller Wv Cu950 Addendum Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 Note: This section describes the terminal mode. To operate in the PS·Data mode, refer to p. 35. ■ On-screen Display (OSD) Control The procedure described below lets you determine the dis- play parameters, such as camera title, clock and status, on and off on the active monitor screen. Before controlling each item, monitor selection is neces- sary. (Refer to p. 3 Monitor Selection.) ●Displaying Each Item 1. Press the MENU button repeatedly until OSD On/Off appears on the LCD. 2. Perform desired operations. qDisplaying the clock Toggle the F1 button. (1) will appear/disappear on/from the active moni- tor. wDisplaying the camera title Toggle the F2 button. (2) will appear/disappear on/from the active moni- tor. eDisplaying the event Toggle the F3 button. (3) will appear/disappear on/from the active moni- tor. rDisplaying the monitor status* Toggle the F4 button. (4)* will appear/disappear on/from the active moni- tor. *Monitor number, system controller name, tour num- ber and recorder number3. To exit the mode, press the MON (ESC) button. ●Displaying All the Items 1. Perform Step 1 of Displaying Each Item. 2. Hold down the SHIFT button. The LCD display will become as follows. 3. Press the F1 button. (1), (2), (3), and (4) will appear/disappear on/from the active monitor. ■ On-screen Display (OSD) Position Control The procedure described below lets you determine the dis- play positions, such as camera title, clock and status, on the active monitor screen. ●Moving Each Item 1. Press the MENU button repeatedly until OSD Position appears on the LCD. MONITOR DISPLAY CONTROL 08/21/2002 12:50:28 PM M1 K1 T01 C01 camera title ALARM10*(1) (3) (4) (2) OSD On/Off 002 Clock Cam Event Mon 08/21/2002 12:50:59 PM M1 K1 T01 C01 camera title ALARM10* Camera title Monitor statusEvent Clock OSD Position 003 Clock Cam Event Mon OSD On/Off 002 All
12 2. Press the MENU button repeatedly until System Status appears on the LCD. 3. Press the F1 button. The SYSTEM STATUS table will appear on the active monitor as shown in the figure. The columns in the table indicate the states as shown in the figure. MON:Monitor number CAM:Logical camera number (01 to 99) Recorder number (R0 to R4)* – – indicates that no camera is being selected. MODE:Lists the display mode on the monitors. SPOT:Spot mode Tnn:Tour Sequence mode (nn is the tour sequence number.) CAM:Camera Setup mode SET:WJ-SX150A Setup mode ALARM:Alarm Active mode ACK:Alarm ACK mode VLD H:Video Loss History Table ALM H:Alarm History Table SYS S:System Status Table RECORDER:Recorder mode** KB:Lists the system controller name (K1 to K4) or PSD. OPE:Lists the operator number PRI:Lists the priority number *R0 to R4 shows the following. Recorder number Recorder R0 Master recorder R1 Slave 1 recorder R2 Slave 2 recorder R3 Slave 3 recorder R4 Slave 4 recorder ** When this parameter is selected, a recorder number is displayed in the CAM area. 4. To close the SYSTEM STATUS table, press the F2 but- ton. 5. To exit the mode, press the MON (ESC) button. 2. Perform desired operations. qMoving the clock display Move the 3D joystick while holding down the F1 but- ton. (1) will move to the desired direction. wMoving the Camera Title Display Move the 3D joystick while holding down the F2 but- ton. (2) will move to the desired direction. eMoving the Event Display Move the 3D joystick while holding down the F3 but- ton. (3) will move to the desired direction. rMoving the Monitor Status* Move the 3D joystick while holding down the F4 but- ton. (4) will move to the desired direction. *Monitor number, controller number and monitor mode ●Moving All the Items 1. Press the MENU button repeatedly until OSD Position appears on the LCD. 2. Hold down the SHIFT button. The LCD display will become as follows. 3. Move the 3D joystick while holding down the F1 button. (1), (2), (3), and (4) (refer to p. 11) will move to the desired position. ■ System Status Table The table shows the current system status. 1. Select the desired monitor. (Refer to p. 3 Monitor Selection.) SYSTEM STATUS MON CAM MODE KB OPE PRI 1 01 T01 K1 12345 30 2 99 SPOT K2 2 2 3 04 ALARM K4 4 1 4 R1 RECORDER PC 30 1 OSD Position 003 Clock Cam Event Mon OSD Position 003 All
13 ■ Alarm History Table There are 100 alarm records stored in chronological order in 10 pages of tables. 1. Select the desired monitor. (Refer to p. 3 Monitor Selection.) 2. Press the ALM RECALL button. Alarm Recall will appear on the LCD. The ALARM HISTORY table will appear on the active monitor as shown in the figure. The columns in the table indicate the status as follows: DATE:Lists the date and time when the alarm status changes. ALARM:Lists the alarm number (01 - 99). EVENT:Lists the event when the alarm status changes. 3. Press the + button to select the next page of the history, and press the – button to back up to the previous page. 4. To exit the mode, press the MON (ESC) or ALM RECALL button. ■ Video Loss History Table There are 100 video loss detection records stored in chronological order in 10 pages of table. 1. Select the desired monitor. (Refer to p. 3 Monitor Selection.) 2. Press the MENU button repeatedly until VLD History appears on the LCD. 3. Press the F1 button. The VIDEO LOSS HISTORY table will appear on the active monitor as shown in the figure. The columns in the table indicate the status as follows: DATE:Lists the date and time when the video loss status changes. CH:Lists logical camera number, slave unit num- ber or recorder number that is connected to the system. EVENT:Lists the event when the video loss status changes. 4. To exit the mode, press the F2 button or MON (ESC) button. ALARM HISTORY 1 of 2 NO YYYY/MM/DD HH:MM:SS ALARM EVENT 016 2002/08/21 18:59:08 80 ALARM 015 2002/08/21 18:58:08 80 ACK 014 2002/08/21 18:57:08 80 RESET 013 2002/08/21 18:55:08 07 ALARM 012 2002/08/21 18:54:08 07 ACK 011 2002/08/21 18:53:08 07 RESET 010 2002/08/21 18:53:00 09 ALARM 009 2002/08/21 18:52:08 09 RESET 008 2002/08/21 18:51:08 06 ALARM 007 2002/08/21 18:50:08 06 ACK VIDEO LOSS HISTORY 1 of 2 NO YYYY/MM/DD HH:MM:SS CH EVENT 012 2002/08/21 18:59:08 99 VIDEO RECOVER 011 2002/08/21 18:58:08 14 VIDEO RECOVER 010 2002/08/21 18:57:08 99 VIDEO LOSS 009 2002/08/21 18:55:08 07 VIDEO LOSS 008 2002/08/21 18:54:08 R0 SW RECOVER 007 2002/08/21 18:53:08 16 VIDEO LOSS 006 2002/08/21 18:53:00 09 VIDEO LOSS 005 2002/08/21 18:52:08 R0 SW LOSS 004 2002/08/21 18:51:08 S1 SLAVE DOWN 003 2002/08/21 18:50:08 S1 SLAVE RECOVER Alarm Recall VLD History 004 On Off
14 MENU or WJ-SX150A Administrator Console. (Refer to the operating instructions of matrix switcher.) ■Operation during an Alarm Mode While an alarm mode is active, the following are available from the system controller: •Operating the camera with the alarm input (ACK) •Resetting the alarm (ALM RESET/ALM ALL RESET) •Suspending the alarm (ALM SUSPENDED) ■Operation of an Alarm-related Camera (ACK) You can operate the camera with the alarm input as follows: 1. Select a monitor which displays ALARM. 2. Press the ACK button. ACK will appear on the monitor with an alarm input. The camera with an alarm input will become operable. 3. Operate camera with the system controller. Panning, tilting, zoom, focus, and iris are available. When selecting another monitor, ACK will disappear from the display. The matrix switcher system will return to the alarm mode. Note: This section describes the terminal mode. To operate in the PS·Data mode, refer to the operating instructions. ■Alarm Mode When alarm (sensor) is accepted, the matrix switchers operation mode changes to the alarm mode. Then, the sys- tem operates as follows: •The camera image (alarm image) appears on the moni- tor. In the factory default setting, the alarm inputs 1 to 16 are associated with the same-numbered camera input connectors. All the video output signals are sent to Monitor 1. For example, when the alarm (sensor) con- nected to the alarm input 1 becomes active, the camera input connector 1’s image appears on Monitor 1. •ALARMnn appears on the monitor. (nn is the alarm number). •Alarm output signals are supplied from Alarm Output 1 to 4 (#10, 11, 23 and 24) of the ALARM port (25-pin D- sub connector) at the rear panel. Alarm Output 1 to 4 is associated with MONITOR OUT 1 to 4. For example, when an alarm input signal is activated on MONITOR OUT 1, the matrix switcher supplies an alarm output signal from Alarm Output 1. •The alarm number and Alarm sign will appear on the LCD. Then, Alarm sign and the alarm indicator will blink. There are two operation modes when more than one alarm signal has been accepted by the matrix switcher that is assigned to the same monitor. • Sequence mode:An alarm operation is replaced by another one after the dwell time ends. • Hold mode:An initial alarm operation is continued even after another alarm input is accepted. Notes: •The association of the alarm inputs with cameras and monitors are changeable in SETUP MENU or WJ- SX150A Administrator Console. (Refer to the operating instructions of matrix switcher.) •Alarm input will be automatically reset in 30 seconds. The auto-recovery time is configurable through SETUP ALARM CONTROL Mon1 Cam01 AL01 Alarm ALARM01ACK
15 ■Resetting the Alarm Inputs There are two alarm reset functions: •Alarm reset (resetting the alarm inputs per monitor) •Alarm all reset (resetting all the alarm inputs) ● Alarm Reset 1. Select a monitor which displays ALARM. 2. To reset the alarms, press the ALM RESET/ALM ALL RESET button. ALARMnn will disappear from the selected monitor. When alarms have been reset from all the monitors, the LCD display and indicators of system controllers will work as follows for recovery. •The LCD display will return to the state before the alarm input. •The alarm indicator will go out. Note:When more than one alarm is input and they are associated with the same monitor, they cannot be reset one by one. ● Alarm All Reset 1. Press the ALM RESET/ALM ALL RESET button while holding down the SHIFT button. 2. The monitor, the indicator, and the LCD display will change as follows: •ALARMnn will disappear from all the monitor. •The LED display will return to the state before the alarm input. •The alarm indicator will go out. ■Suspending the Alarm Inputs Use this function when you do not want to be disturbed by an alarm input, for example, during the setup procedures. 1. Press the ALARM/ALM SUSPEND button while holding down the SHIFT button. ALM SUSPENDED will appear on the monitor, and the ALM SUSPEND indicator will light up. 2. To cancel alarm suspension, press the ALARM/ALM SUSPEND button while holding down the SHIFT button again. ALM SUSPENDED will disappear from the monitor, and the ALM SUSPEND indicator will go out. Notes: •An alarm continues to operate even after it is suspend- ed. • If you suspend an alarm while an alarm image is dis- played, ALM SUSPENDED will not appear on the moni- tor. Reset the alarm, and then suspend it again. ALM SUSPENDED
16 MULTIPLEXER OPERATIONS MUX Multiplexer board WJ-SXB151 is an optional board. It enables multiscreen display, electronic zooming, still pic- ture and multiscreen sequence. It also enables the operation of Digital Disk Recorder WJ- HD100 Series or time-lapse VCR, when connected to them. Note:Before the use, it is necessary to install the Multiplexer board in the matrix switcher and configure the system through SETUP MENU and WJ-SX150A Administrator Console. (Refer to the operating instruc- tions of matrix switcher.) ■Monitoring the Camera Picture ●Multiscreen Segment Switching 1. Select the desired monitor. (Refer to p. 3 Monitor Selection.) 2. To select a Multiplexer, press the corresponding numeric button. Multiplexer board Numeric button Master Multiplexer board 0 (You can skip pressing this button.) Slave 1 Multiplexer board 1 Slave 2 Multiplexer board 2 Slave 3 Multiplexer board 3 Slave 4 Multiplexer board 4 3. Press the RECORDER/UNIT button. The system will enter the recorder mode. The images from the recorder are displayed on the active monitor in multiscreen seg- ments. 4. Press the MULTI SCREEN button. Every time you press the button, the multiscreen seg- ment patterns are switched. (The following is the factory default setting.) 4 (segments) →9 →16 →4 5. To return to the spot display, select the desired camera. Note:If you activate Quad Shift in Multiplexer Mode win- dow of WJ-SX150A Administrator Console, the multi- screen segment patterns can be switched as follows. 4A (Page 1 of the quad – Camera 1, 2, 3, and 4) →4B (Page 2 - Camera 5, 6, 7 and 8) →4C (Page 3 - Camera 9, 10, 11 and 12) →4D (Page 4 - Camera 13, 14, 15 and 16) →9 (segments) →16 →4A (Refer to the operating instructions of matrix switcher.) ●Multiscreen Sequence Camera images are switched automatically in a sequence mode. The sequence mode (QUAD, 3+1, 8+1) is configurable through WJ-SX150A Administrator Console. (Refer to the operating instructions of matrix switcher.) 1. Enter the recorder mode. (Refer to Step 1 to 3 of Multiscreen Segment Switching.) 2. Press the TOUR SEQ/GROUP SEQ button. A sequence of multiscreen pictures is displayed according to the WJ-SX150A Administrator Consoles configuration. 3. To cancel the sequence, press the MULTI SCREEN but- ton. Note:The sequence can also be cancelled by selecting the desired camera. (In this case, you can automatically exit the recorder mode.) ●Still Multiscreen Picture Still pictures can also be displayed in a multiscreen. 1. Enter the recorder mode. (Refer to Step 1 to 3 of Multiscreen Segment Switching.) 2. Press the MENU repeatedly until Mux Still appears on the LCD. 3. Press the numeric button corresponding to the camera number. 4. Press the F1 button. The selected camera image will change into the still picture. STILL and the camera title alternately blink on the monitor. 5. To cancel the still picture, press the numeric button cor- responding to the desired camera number, and then press the F1 button. Notes: •STILL does not appear when the still display is set to OFF. •When you skip Step 3 and do Step 4, all the channels displayed in the multiscreen segments will be changed into the still pictures. Mux Still 052 Input Still CH
17 6. Press the EL-ZOOM button. The area surrounded by the + signs will be zoomed up. 7. To move the zoom area, move the 3D joystick. 8. To cancel the zooming, press the EL-ZOOM button. Note:Still picture is not available while zooming is acti- vated. Note:When a WJ-HD100 Series recorder or a Panasonic time-lapse VCR is connected to the matrix switcher, recording status will appear on the monitor in the recorder mode. When the normal recording is activat- ed, REC will appear on the monitor. When the alarm recording is activated, REC ALM will appear. ●Still Playback Spot Picture The playback spot picture can be changed into the still pic- ture. Note:To use this function, you need to connect a WJ-HD100 Series recorder or time-lapse VCR to the matrix switcher. 1. Enter the recorder mode. (Refer to Step 1 to 3 of p. 16 Multiscreen Segment Switching.) 2. Press the PLAY/PAUSE button. The system will enter the playback mode. 3. Select a camera channel by pressing a numeric button and then pressing the CAM (SET) button. The selected camera image will be displayed in a spot picture. 4. Press the MENU repeatedly until Mux Still appears on the LCD. 5. Press the F1 button. The selected camera image will change into the still picture. 6. To cancel the still picture, press the F1 button again. Notes: •Still picture is not available while zooming is activat- ed. •Even when still picture is displayed, the playback of the recorder/time-lapse VCR continues. ●Electronic Zooming (EL-ZOOM) The playback spot picture can be electrically zoomed. Note:To use this function, you need to connect a WJ-HD100 Series recorder or time-lapse VCR to the matrix switcher. 1. Enter the recorder mode. (Refer to Step 1 to 3 of p. 16 Multiscreen Segment Switching.) 2. Press the PLAY/PAUSE button. The system will enter the playback mode. 3. Select a camera channel by pressing a numeric button and then pressing the CAM (SET) button. The selected camera image will be displayed in a playback spot pic- ture. 4. Press the EL-ZOOM button. + signs will appear on the image. 5. To move the + signs within the picture, move the 3D joystick. REC REC ALMMux Still 052 Input Still CH
18 WJ-HD500 SERIES CONTROL (TERMINAL MODE) Matrix switcher can control the following functions of Digital Disk Recorder WJ-HD500 Series. The following is the pro- cedure of WJ-HD500 Series SETUP MENU. Notes: •The following operating procedures are for the terminal mode. If you are using a PS·Data system controller, refer to p. 36. •When a Multiplexer board is installed in the matrix switcher, you can neither connect nor control a WJ- HD500 Series recorder. You need to remove the board from the matrix switcher. ■Displaying WJ-HD500 Series SETUP MENU To display WJ-HD500 Series SETUP MENU, follow the pro- cedure below. 1. Confirm that WJ-HD500 Series is correctly and securely connected. 2. Select the desired monitor. (Refer to p. 3 Monitor Selection.) 3. Enter the recorder mode. (Refer to p. 19 Recorder Mode.) Then, the selected monitor number, recorder number, and /HDnnn will appear on the LCD. 4. Press the MENU button repeatedly until “System Setup” appears on the LCD. 5. Press the F1 button. WJ-HD500 Series SETUP MENU will appear on the active monitor, and “ B” mark will light up beside “On”. 6. Perform the camera setting while watching the setup menu on the monitor. The following functions and buttons are valid in SETUP MENU. JogDial clockwise: Increments a parameter. JogDial counterclockwise:Decrements a parameter. CAM (SET) button:Executes the selections and dis- plays a submenu. + button:Increments a parameter. – button:Decrements a parameter. MON (ESC) button:Returns to SETUP MENU or the previous menu. 3D joystick upward ( D):Moves the cursor up. 3D joystick downward (C):Moves the cursor down. 3D joystick leftward (A):Moves the cursor to the left. 3D joystick rightward (B):Moves the cursor to the right. 7. To end the setting and return to the normal view, press the F2 button while SETUP MENU is displayed. B mark will disappear from the LCD. Mon4 Cam-- R4 /HD500 System Setup 501 5On Off System Setup 501 On Off
19 ■Controlling Digital Disk Recorder WJ-HD500 Series The following are the operating procedures of WJ-HD500 Series via system controller. Note: Refer to the operating instructions of Digital Disk Recorder WJ-HD500 Series for details. ●Recorder Mode Before operating the recorder, it is necessary to enter the recorder mode. 1. Select the desired monitor. (Refer to p. 3 Monitor Selection.) 2. To select a recorder, press the corresponding numeric button. Recorder Numeric button Master recorder 0 (You can skip pressing this button.) Slave 1 recorder 1 Slave 2 recorder 2 Slave 3 recorder 3 Slave 4 recorder 4 3. Press the RECORDER/UNIT button. The system will enter the recorder mode. •The images from the recorder are displayed on the active monitor in multiscreen segments. •The camera number will disappear from the LCD. •The monitor number, recorder number, and / HD500 will appear on the LCD. 4. To exit the recorder mode, select the camera. (Refer to p. 3 Camera Selection.) The monitor number and cam- era number will appear on the LCD again. You can also exit the recorder mode by pressing the RECORDER/UNIT button during the recorder mode. Note: Only one operator can enter the recorder mode. ●Multiscreen Segment Switching Multiscreen segment patterns are configurable through WJ- HD500 SETUP. (Refer to the recorder’s operating instructions.) 1. Enter the recorder mode. (Refer to Recorder Mode.) 2. Press the MULTI SCREEN button. Every time you press the button, the multiscreen segment patterns are switched. (The following is the factory default setting.) 4A (Page 1 of the quad →Camera 1, 2, 3, and 4) →4B (Page 2 - Camera 5, 6, 7 and 8) →4C (Page 3 - Camera 9, 10, 11 and 12) →4D (Page 4 – Camera 13, 14, 15 and 16) →7 (segments) →9 →10 →13 →16 → 4A 3. To return to the spot display, exit the recorder mode. Note:Multiscreen segment patterns are not configurable through WJ-SX150A Administrator Console. ●Normal Playback 1. Enter the recorder mode. (Refer to Recorder Mode.) 2. To start the playback, press the PLAY/PAUSE button. The system will enter the playback mode. Then, the most recent recorded image will be played back. •To pause the playback, press the PAUSE button. •To stop the playback, press the STOP button. • To resume the playback, press the PLAY/PAUSE button. •To move forward/backward search during the play- back, move the shuttle ring clockwise or counter- clockwise. Shuttle ring clockwise:Fast-forward playback Shuttle ring counterclockwise:Rewind playback Shuttle hold button:If you press this button while rotating the shuttle ring, playback speed will be maintained even after removing a hand from the shuttle ring. (The LED indicator on this button blinks during the fast playback.) •To move forward/backward field advance during the pause, move the JogDial clockwise or counter- clockwise. JogDial clockwise:Forward field advance JogDial counterclockwise:Backward field advance Mon4 Cam-- R4 /HD500
20 •To skip to the previous/next record during the play- back, move the JogDial clockwise or counterclock- wise. (Refer to the recorder’s operating instructions for the description of record.) JogDial clockwise:Skips to the next record. JogDial counterclockwise:Skips to the previous record. •To display the spot picture, press the numeric but- ton corresponding to the desired camera number, then press the CAM (SET) button. Then, the active camera number will appear on the LCD. •To resume the multiscreen display, press the MULTI SCREEN button. •To change the number of multiscreen segments, press the MULTI SCREEN button again during the multiscreen display. 3. To stop the playback, press the STOP button. The mon- itor display will return to the multiscreen display. ●Manual Recording 1. Enter the recorder mode. (Refer to p. 19 Recorder Mode.) 2. To start recording, press the REC button. The digital disk recorder will start recording. 3. To stop the recording, hold down the REC button. Note:Refer to WJ-HD500 Series Operating Instructions for details and other recording modes. ●Stopping REC ONLY Alarm Recording You can stop alarm recording activated by REC ONLY setting of 430 CAMERA/440 ALARM PORT/450 SERIAL PORT/460 MUX MOTION DET in SETUP MENU or the Alarm Mode window in WJ-SX150A Administrator Console. (Refer to the operating instructions of matrix switcher.) To stop the alarm recording, press the ALL RESET button while holding down the SHIFT button. ●Search Playback You can search playback images using the Record List or Thumbnail Display. Every time you press the SEARCH/T&D SEARCH button, the monitor display will change as follows. Live image →Date-and-time entry form →Record List → Thumbnail Display →Live image... Then, Search Mode will appear on the LCD. • Date-and-time Search Playback The recorded images can be searched for through the date and time. 1. Enter the recorder mode. (Refer to p. 19 Recorder Mode.) 2. Press the SEARCH/T&D SEARCH button. The date-and- time entry form will appear on the center of the monitor. Note:The factory default setting is the current date and time. 3. Press the numeric buttons or +/– button to enter the desired date and time. The cursor can be adjusted by moving the 3D joystick rightward or leftward. 4. Press the PLAY/PAUSE button. Record List will be dis- played and the cursor will move to the closest date and time. Note:To cancel the entry form, press the MON (ESC) or EXIT button. Search Mode /HD500 Edit Group Alm SEARCH YYYY/MM/DD HH:MM 2002/05/07 19:32 Mon4 Cam01 R4 /HD500