Have a look at the manual Panasonic System Controller Wv Cu950 Addendum Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
31 3. Press the numeric buttons or +/– button to enter the desired date and time. The cursor can be adjusted by moving the 3D joystick rightward or leftward. 4. Press the PLAY/PAUSE button. After the search through the date and time, the recorded image will be played. 5. To return to the multiscreen display, press the STOP button. Note:To cancel the entry form, press the MON (ESC) or EXIT button. • ALARM RECALL table The recorder’s alarm history will be displayed on the ALARM RECALL table. 1. Press the ALM RECALL button. The ALARM RECALL table will appear on the monitor. 2. Move the cursor with the 3D joystick to the desired alarm number, and then press the PLAY/PAUSE button. The associated image will be played back. ●Electronic Zooming (EL-ZOOM) The operations are the same as WJ-HD500 Series. (Refer to p. 21.) Note:2 x and 4 x are available zooming range. 8 x is unavailable. ●Multiscreen Sequence The operations are the same as WJ-HD500 Series. (Refer to p. 21.) ALARM RECALL YEAR03 NO. DATE TIME ALM 2000 JUN14 20:30:00 T1 1999 JUN14 15:30:12 T3 1998 JUN14 12:15:04 T4 1997 JUN14 12:15:02 V8 1996 JUN14 10:07:05 V2 1995 JUN14 10:07:04 T2 1994 JUN14 10:06:55 T6 1993 JUN14 09:58:32 V5 (TOTAL 2000EVENTS) TO SEARCH PUSH T&D KEY
32 WJ-HD100 SERIES CONTROL (TERMINAL MODE)MUX Digital Disk Recorder WJ-HD100 Series are operable with the system controller, when the Multiplexer board is installed in the matrix switcher. Note:Before the use, it is necessary to install the Multi- plexer board in the matrix switcher, connect the matrix switcher to the digital disk recorder, and con- figure the system through WJ-SX150A Administrator Console, OSD SETUP MENU, and WJ-HD100 Series SETUP MENU. (Refer to the operating instructions of matrix switcher.) ■Displaying WJ-HD100 Series SETUP MENU The operations are the same as WJ-HD500 Series. Refer to p. 18 Displaying WJ-HD500 Series SETUP MENU. The following functions and buttons are valid in SETUP MENU. 3D joystick to the left (A):Decrements a parameter 3D joystick to the right (B):Increments a parameter ■Controlling Digital Disk Recorder WJ-HD100 Series The following are the operating procedures of WJ-HD100 Series via the system controller. ●Multiscreen Segment Switching The operating procedure is the same as WJ-HD500 Series. (Refer to p. 19.) Note:7-, 10-, or 13-segment multiscreen display is unavail- able. ●Normal Playback The operations are the same as WJ-HD500 Series. (Refer to p. 19.) Notes: •You cannot skip to the previous/next record. •Refer to WJ-HD100 Series Operating Instructions for details and other playback modes. ●Manual Recording The operations are the same as WJ-HD500 Series. Refer to p. 20. ●Stopping REC ONLY Alarm Recording The operations are the same as WJ-HD500 Series. Refer to p. 20. ●Search Playback You can search playback images using the ALARM RECALL table or the SEARCH table. Every time you press the SEARCH/T&D SEARCH button, the display will change as follows. Live image →Date-and-time entry form→ALARM RECALL table →Live image • Date-and-time Search Playback The recorded images can be searched for through the date and time. 1. Enter the recorder mode. (Refer to p. 19 Recorder Mode.) 2. Press the SEARCH/T&D SEARCH button. The date-and- time entry form will appear on the center of the monitor. Note:The factory default setting is the current date and time. SEARCH YYYY/MM/DD HH:MM 2002/05/07 19:32
33 3. Press the numeric buttons or +/– button to enter the desired date and time. The cursor can be adjusted by moving the 3D joystick rightward or leftward. 4. Press the PLAY/PAUSE button. After the search through the date and time, the recorded image will be played. 5. To return to the multiscreen display, press the STOP button. Note:To cancel the entry form, press the MON (ESC) or EXIT button. • ALARM RECALL table The recorder’s alarm history will be displayed on the ALARM RECALL table. 1. Press the ALM RECALL button. The ALARM RECALL table will appear on the monitor. 2. Move the cursor with the 3D joystick to the desired alarm number, and then press the PLAY/PAUSE button. The associated image will be played back. ALARM RECALL 1 OF 10 NO DATE TIME ALM 99 JUN 9.00 00:00:00 * T 98 JUN 1.00 02:34:56 T 97 JUN 1.00 01:10:01 * V 96 MAY31.00 23:34:45 V 95 MAY30.00 02:00:20 * T 94 MAY14.00 05:30:31 * T 93 MAY 7.00 23:00:59 T 92 MAY 6.00 22:05:50 V 91 APR14.00 23:00:59 * T 90 APR14.00 16:06:34 * V
34 TIME-LAPSE VCR CONTROL [PANASONIC MODELS] (TERMINAL MODE)MUX A time-lapse VCR (Panasonic Models) is operable with the system controller, while connecting to the matrix switcher. Note:Before the use, it is necessary to install the Multiplexer board in the matrix switcher, connect the matrix switcher to the time-lapse VCR, and con- figure the system through WJ-SX150A Administrator Console, OSD SETUP MENU, and time-lapse VCRs SETUP MENU. (Refer to the operating instructions of matrix switcher.) The following is the procedure of a Panasonic model time- lapse VCR. ■Controlling the Time-lapse VCR The following are the operating procedures of the time- lapse VCR via system controllers. ●Multiscreen Segment Switching The operations are the same as WJ-HD500 Series. (Refer to p. 19.) Note:7-, 10-, and 13- segment multiscreen display pat- terns are unavailable. ●Normal Playback The operations are the same as WJ-HD500 Series. (Refer to p. 19.) Note:You cannot skip to the previous/next record. ●Fast-forward 1. During the stop, execute System Function 11. (Refer to the operating instructions of system controller for how to operate.) The tape will be fast-forwarded. 2. To stop fast-forwarding, press the STOP button. Note:Pressing the PLAY/PAUSE button during fast-for- ward will start playback. ●Rewind 1. During the stop, execute System Function 12. (Refer to the operating instructions of system controller for how to operate.) The tape will be rewinded. 2. Press the STOP button to stop rewinding. Note:Pressing the PLAY/PAUSE button during rewind will start playback. ●Manual Recording The operations are the same as WJ-HD500 Series. Refer to p. 20 Manual Recording. ●Stopping REC ONLY Alarm Recording The operations are the same as WJ-HD500 Series. Refer to p. 20.
35 TIME-LAPSE VCR CONTROL [NON-PANASONIC MODELS] (TERMINAL MODE)MUX MONITOR DISPLAY CONTROL (PS·DATA) A time-lapse VCR is operable with the system controller, while connecting to the matrix switcher. Notes: •Before the use, it is necessary to install the Multiplexer board in the matrix switcher, connect the matrix switcher to the digital disk recorder, and configure the system through WJ-SX150A Administrator Console, OSD SETUP MENU, and time-lapse VCRs SETUP MENU. (Refer to the oper- ating instructions of matrix switcher.) •You cannot control non-Panasonic time-lapse VCRs from system controllers. The following is the procedure of a non-Panasonic model time-lapse VCR. ■Controlling the Time-lapse VCR ●Multiscreen Segment Switching The operations are the same as WJ-HD500 Series. (Refer to p. 19.) Note:7-, 10-, and 13- segment multiscreen display pat- terns are unavailable. ●Normal Playback 1. Enter the recorder mode. (Refer to p. 19 Recorder Mode.) 2. Do the playback procedure using the buttons on the front panel. (Refer to the time-lapse VCR’s operating instructions for how to operate.) 3. Press the PLAY/PAUSE button. The playback image will appear on the monitor. 4. To display the spot picture, press the numeric buttons corresponding to the desired camera number, then press the CAM (SET) button. Then, the active monitor number will appear on the LCD. (Refer to p. 20 Normal Playback for the illustration.) ●Other Operations Refer to the time-lapse VCR’s operating instructions for how to operate. The operations are the same as System Controller WV- CU360C/CJ. (Refer to the operating instructions of matrix switcher for how to operate.) However, the following operations differ from System Controller WV-CU360C/CJ. ■ On-screen Display (OSD) Control Refer to WV-CU950/650 Operating Instructions. ■ Video Loss History Table Refer to WV-CU950/650 Operating Instructions.
36 WJ-HD500/300/200/100 SERIES CONTROL (PS·DATA) The details on recorder control are described in WV- CU950/WV-CU650 Operating Instructions. However, when the system controller (WV-CU950 or WV-CU650) is con- nected to recorders via the matrix switcher (WJ-SX150 Series), the following differences will occur. ■Unavailable Functions through WJ-SX150A Connection The following functions are unavailable when the system controller (WV-CU950 or WV-CU650) is connected to recorders via the matrix switcher (WJ-SX150 Series). ●HD500 V-Multi ●HD200 Alarm Search ■Functions Only Available with WJ-HD300 Series The following functions are available only when the system controller (WV-CU950 or WV-CU650) is connected to WJ- HD300 Series via the matrix switcher (WJ-SX150 Series). ●Time & Date Search Playback ■Functions Only Available with WJ-HD200 Series/WJ-HD100 Series The following functions are available only when the system controller (WV-CU950 or WV-CU650) is connected to WJ- HD200 Series or WJ-HD100 Series via the matrix switcher (WJ-SX150 Series). Note:This function is unavailable when the system con- troller (WV-CU950 or WV-CU650) is connected to WJ- HD500 Series via the matrix switcher (WJ-SX150 Series). ●Alarm Recall (WJ-HD200 Series) The LCD display becomes as follows. ●Alarm Recall (WJ-HD100 Series) The LCD display becomes as follows. LCD MENU HDD 204 HD500 V—Multi Alarm Recall /HD200 Edit Alarm Recall /HD100 J/S MENU 514 HD200 Alm Search Mmm/DD/YYYY HH:MM 12 Mar/17/2004 12:00 AM
37 ■Connection with Digital Disk Recorder WJ-HD300 Series Notes: •Refer to service personnel for details on the connection with a recorder to operate via LAN or the Internet. •Check that the firmware of recorder is Ver. 1.30 or later. •Only one recorder can be connected to the DATA HDR connector of this unit. (Multiple unit connections, such as cascade connection, are not available.) ●Basic Connection The following is the description of the connection between a recorder and this unit to confirm the images from the recorder. 1. Set the unit address of the recorder to 1. 2. Set the [Camera control] setting to “PSD” for all cameras in SETUP MENU of the recorder. 3. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 4. Connect the unit’s EXT IN connector to the recorder’s MULTISCREEN OUT connector with a coaxial cable. 5. Connect the unit’s DATA HDR connector to the recorder’s DATA port with a modular cable. Notes: •Make sure the recorder’s unit address is set to 1 through SETUP MENU or WJ-SX150A administrator Console. (Refer to this unit’s operating instructions.) If another number is selected, you cannot control the recorder. •To control cameras at the front panel of recorder, connect the DATA 4 connector and the DATA port of recorder with a modular cable. (PS·Data system controller is not connectable to the DATA 4 connec- tor.) •From system controllers connected to the unit (WJ- SX150A), you cannot control the monitor connected to the MONITOR OUT 1 connector of recorder. (2) ADDENDUM FOR MATRIX SWITCHER WJ-SX150 SERIES: TO USE DIGITAL DISK RECORDER WJ-HD300 SERIES/WJ-HD220 SERIES SIGNAL GND POWER AC IN CAMERA1 12 23 3 2 DATA 3 DATA 2SERIAL ALARM TERM OFF ON42 14 3 CAMERA SW INRS485(CAMERA)LINE SELECTMONITOR OUT EXT IN (PLAY IN) EXT OUT (REC OUT) OUTIN 4 45 56 67 78 89 910 1011 1112 1213 1314 1415 1516 16 RS485(CAMERA) DATA 4 DATA HDR PS•DATADATA 1 1 2 IN OUTCASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND1 42 System controller (Terminal Mode) EXT IN MONITOR OUT Matrix Switcher Recorder** DATA 4 * (PS·Data) DATA HDR MONITOR OUT x DATA * Connect these ports if you control cameras from the front panel of recorder. ** Set the recorder’s unit address to 1.Monitor SYSTEM CONNECTIONS AND SETUPS (WJ-HD300 SERIES/WJ-HD220 SERIES)
38 ●To Control a Recorder and Cameras via the Network The following is the description of the connection between a recorder and this unit to control the recorder and cameras via the network. 1. Set the unit address of the recorder to 5 or larger. (Refer to the recorder’s operating instructions.) 2. Set the [Camera control] setting to “PSD” for all cameras in SETUP MENU of the recorder. 3. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 4. Connect the unit’s EXT IN connector to the recorder’s MULTISCREEN OUT connector with a coaxial cable. 5. Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA ports with modular cables. 6. Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER of SETUP MENU or the Recorder window of WJ-SX150A Administrator Console. (Refer to this unit’s operating instructions.) Notes: •Select the PS·Data protocol for the DATA 4 setting. (Refer to this unit’s operating instructions.) •If the recorder’s unit address, set in Step 1, and the recorder setting, set in Step 6, are different, the recorder will not be operable. •In these connections, you cannot use a PS·Data system controller. •From system controllers connected to the unit, you cannot control the monitor connected to the MONITOR OUT 1 connec- tor of recorder. SIGNAL GND POWER AC IN CAMERA1 12 23 3 2 DATA 3 DATA 2SERIAL ALARM TERM OFF ON42 14 3 CAMERA SW INRS485(CAMERA)LINE SELECTMONITOR OUT EXT IN (PLAY IN) EXT OUT (REC OUT) OUTIN 4 45 56 67 78 89 910 1011 1112 1213 1314 1415 1516 16 RS485(CAMERA) DATA 4 DATA HDR PS•DATADATA 1 1 2 IN OUTCASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND1 42 EXT IN MONITOR OUT DATA 4 (PS·Data) DATA HDR Matrix Switcher Recorder* HUB/Router MONITOR OUT x DATA * Set the recorder’s unit address to 5 or larger. ** LAN: Local Area Network LAN** System controller (Terminal Mode)Monitor
39 ●PS·Data Connection 1. Set the unit address of the recorder to 5 or larger. 2. Set the [Camera control] setting to “PSD” for all cameras in SETUP MENU of the recorder. 3. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable. 4. Connect the unit’s DATA4 Port connector to the recorder’s DATA port with a modular cable. Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER of SETUP MENU or the Recorder window of WJ-SX150A Administrator Console. (Refer to this unit’s operating instructions.) Notes: •Select the PS·Data protocol for the DATA 4 setting. (Refer to this unit’s operating instructions.) •If the recorder’s unit address, set in Step 1, and the recorder setting, set in Step 5, are different, the recorder will not be operable. •Do not connect the recorder to the DATA HDR port. •From system controllers connected to the unit, you cannot control the recorder. •Only one matrix switcher can be connected in the PS·Data mode. SIGNAL GND POWER AC IN CAMERA1 12 23 3 2 DATA 3 DATA 2SERIAL ALARM TERM OFF ON42 14 3 CAMERA SW INRS485(CAMERA)LINE SELECTMONITOR OUT EXT IN (PLAY IN) EXT OUT (REC OUT) OUTIN 4 45 56 67 78 89 910 1011 1112 1213 1314 1415 1516 16 RS485(CAMERA) DATA 4 DATA HDR PS•DATADATA 1 1 2 IN OUTCASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND1 42 MONITOR OUTMonitor Monitor Monitor System controller (Terminal Mode)* System controller (PS·Data) DATA 4 * (PS·Data) MONITOR OUT x MONITOR OUT zDATAMatrix Switcher Recorder* * Recorder control from system controllers connected to the matrix switcher is not available.
40 ●Settings of Administrator Console and SETUP MENU(OSD) When WJ-SX150A Administrator Console is Ver. 2.03 or later Select “HD300”. When the firmware of this unit is Ver. 2.03 or later. Select “HD300” for “CONTROL” in 600 RECORDER of SETUP MENU(OSD). ■Connection with Digital Disk Recorder WJ-HD220 Series ●To Confirm the Images from a Recorder Connected to the Unit •Connection procedures are the same as WJ-HD200 Series. (Refer to the operating instructions of matrix switcher.) •Set the DATA setting to “PSD” for CAMERA 1 to 4 in the CAMERA SYSTEM SETUP menu of the recorder. ●To Control a Recorder via the Network •Connection procedures are the same as WJ-HD200 Series. •Set the DATA setting to “PSD” for CAMERA 1 to 4 in the CAMERA SYSTEM SETUP menu of the recorder. ●Settings of Administrator Console and SETUP MENU(OSD) Select “HD200” in the Administrator Console window. 600 RECORDER CONTROL ADR EXT IN 610 MASTER --- 620 SLAVE1 HD300 01 GENLOCK OFF 630 SLAVE2 HD300 01 GENLOCK OFF 640 SLAVE3 HD100 01 650 SLAVE4 OFF GENLOCK OFF --COMMUNICATION STATUS-- DATA BIT 7bit PARITY BIT ODD STOP BIT 1bit BAUD RATE 9600bps COMM PORT SERIAL PORT