    Have a look at the manual Panasonic System Controller Wv Cu950 Addendum Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							This operation is skipped when the auto login is set to ON.
    (Refer to the operating instructions of matrix switcher.)
    1. Turn on the power switches of all system components.
    The OPERATE indicator will light up.
    2. To turn on the power of the system controller, connect
    the AC adapter to the AC outlet.
    The OPERATE indicator lights up and Terminal Mode
    No User appears on the LCD.
    BEFORE OPERATION
    INSTALLATIONS AND CONNECTIONS
    SETUP PROCEDURES (HARDWARE)
    Note: This section describes the terminal mode. To operate
    in the PS·Data mode, refer to the operating instructions.
    Before starting the following procedures, all system compo-
    nents must be turned on.
    The following procedures are applicable when the system
    controller is connected to the matrix switcher.
    ■ Operation Start (Login)
    Note:When auto login is set to ON, operators can log into
    the system without entering their passwords. (Refer to
    p. 2 Operation Start (Auto Login).)Terminal Mode
    No User
    Addendum for WV-CU950/650 and WJ-SX150 Series
    (1) ADDENDUM FOR SYSTEM CONTROLLER WV-CU950/WV-CU650: 
    MATRIX SWITCHER WJ-SX150 SERIES 
    OPERATING PROCEDURES
    The descriptions in this document are applicable when WJ-SX150A Administrator Console and the firmware of this unit (matrix
    switcher) are Ver. 2.04 or later.
    Note:Refer to the operating instructions of matrix switcher for how to check the version.
    ■Basic System Connections
    •The connection details are the same as System
    Controller WV-CU360C/CJ. Refer to the operating
    instructions of matrix switcher .
    •
    To connect System Controller WV-CU950 or WV-CU650
    to Digital Disk Recorder WJ-HD300 Series or WJ-HD220
    Series via the matrix switcher, refer to pp. 37 to 40.
    ■MODE Switch Setting
    Either of the terminal mode or PS·Data mode are applicable
    for connections. Refer to WV-CU950/WV-CU650 Operating
    Instructions for details on the switch setting for each mode.
    ■CONTROLLER NO. Switch
    Setting
    Normally, set this switch to “1” (default position). 
    						
    							2
    ■ Operation End (Logout)
    This operation is skipped when the auto logout is set to ON. 
    This function is used when an operator leaves the controller
    or no longer requires access to the system.
    To log out of the system, press the MON LOCK/LOGOUT
    button while holding down the SHIFT button.
    Logout will blink on the LCD for about 3 seconds. Then,
    Terminal Mode No User appears on the LCD.
    Note:If you want to save the power consumption, discon-
    nect the DC 9 V plug from the controller, and remove
    the AC adapter from the AC outlet.
    ■ Operation End (Auto Logout)
    If the auto logout is set to ON and no operation takes place
    for a specific time, any operators can logout automatically.
    After the logout, Terminal Mode No User automatically
    appears on the LCD.
    You can activate auto logout and set up the duration until
    logout (configurable by minute) through WJ-SX150A
    Administrator Console. (Refer to the operating instructions
    of matrix switcher.) 3. To select your registered operator ID number (1 to 16,
    up to 2 digits), press the numeric buttons, then press
    the CAM (SET) button.
    Password entry form appears on the LCD.
    Note:The factory default setting is 150.
    4. To select your registered password (up to 5 digits),
    press the numeric buttons, then press the CAM (SET)
    button.
    The factory default setting is 150.
    If the operator ID and password are correct, Login OK
    will blink on the LCD for about 3 seconds. Then, Mon -
    Cam - - will appear on the LED display.
    Note:If an operator ID or password error occurs,
    Invalid will blink on the LCD for about 3 seconds.
    Then, return to Step 3 and select your operator ID.
    ■ Operation Start (Auto Login)
    If the auto login is set to ON, any operators can log into the
    system automatically. After the controller is turned on, Auto
    Login appears on the LCD for approximately 2 seconds,
    then Mon - Cam - - automatically appears.
    Auto login is configurable through WJ-SX150A
    Administrator Console. (Refer to the operating instructions
    of matrix switcher.)
    Mon-  Cam--
    User ID          150
    Password       __∗∗∗
    Mon-  Cam--
          Invalid
    Blinking
    Terminal Mode
    No User
    Terminal Mode
    No User
    User ID          150
    Password       _____ 
    						
    							3
    ● Releasing Priority Lock
    1. Select the desired monitor. (Refer to Monitor Selection.)
    2. Press the MON LOCK/LOGOUT button to release the
    priority lock mode.
    The monitor number returns to the normal display on
    the active monitor.
    ■ Camera Selection
    1. Select the desired monitor. (Refer to Monitor Selection.)
    2. Press the numeric buttons to select the desired camera
    number (1 to 99).
    3. Press the CAM (SET) button.
    The selected cameras image will appear on the active
    monitor, and the selected camera number will appear
    on the LCD.
    Note:If you have entered a wrong camera number,
    press the CLEAR button to clear the input.
    4. If the selected camera number is not valid, Prohibited
    and the camera number will blink on the LCD for about
    3 seconds.
    In this case, return to Step 2 and select another camera
    number.
    Note:If the camera is selected by an operator with
    higher priority, Prohibited will also blink on the
    LCD.
    5. To replace the currently selected camera with the next
    higher-numbered camera , press the + button.
    To replace the currently selected camera with the next
    lower-numbered camera, press the – button.
    Note:Cameras selected by operators with higher priori-
    ty will be skipped.
    Note: This section describes the terminal mode. To operate
    in the PS·Data mode, refer to the operating instructions.
    After the login procedure, the following operations are avail-
    able to control the system.
    The operation begins with monitor selection. Then, the
    image of selected camera appears on the active monitor.
    ■ Monitor Selection
    1. To select the desired monitor number (1 to 4), press the
    numeric button.
    2. Press the MON (ESC) button to execute the selection.
    The selected monitor number will appear on the LCD.
    3. If the selected monitor number is not valid, or if an oper-
    ator with higher priority is controlling the monitor, the
    monitor number and Prohibited will blink on the LCD
    for approximately 3 seconds.
    In this case, return to Step 1 and select another monitor
    number.
    ■ Priority Lock
    ● Applying Priority Lock
    1. Select the desired monitor. (Refer to Monitor Selection).
    2. Press the MON LOCK/LOGOUT button to toggle the pri-
    ority lock mode on and off on the active monitor.
    If the priority lock mode is selected, the monitor number
    will inversely appear on the active monitor as shown in
    the figure.
    Note:This function will prevent operators with lower priority
    from gaining control of a monitor.
    However, higher or equal priority operators may still
    gain control of the monitor.
    Mon1  Cam--
    MONITOR SELECTION AND CAMERA SELECTION
    Mon1  Cam03
    Mon1  Cam03
    Mon1  Cam04
    Mon-  Cam--
              Prohibited
    Blinking
    M04M04 
    						
    							4
    Note: This section describes the terminal mode. To operate
    in the PS·Data mode, refer to the operating instructions.
    Buttons and control for cameras or camera site accessories
    are located on the 3D joystick unit and the right side of
    main unit.
    Included are zoom control, focus control, iris control, preset
    and pan/tilt controls. 
    Normally, combination cameras equipped with the specific
    feature or a WV-RC100 or WV-RC150 Receiver are required
    to utilize these functions.
    Note:Refer to the cameras operating instructions whether
    to confirm that each function is available.
    ■ Lens Control
    This function is available when specified lens, with motor-
    ized zoom/focus functions, is mounted on the camera, and
    the lens selection (DC/VIDEO) on the camera is set to DC.
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the FOCUS FAR or NEAR button while watching
    the monitor. The lens focus is adjusted to obtain a
    sharply focused image.
    Note:Pressing the B button or top button of 3D joystick
    unit can also set the lens focus automatically.3. To adjust the lens zoom, move the zoom wheel con-
    troller to the right (TELE) or left (WIDE).
    4. Press the IRIS OPEN or CLOSE buttons to open/close
    the lens iris. The lens iris is adjusted by these buttons to
    obtain the proper image exposure.
    Note:To set the lens iris automatically, press the A but-
    ton of 3D joystick unit.
    ■ Pan/Tilt Control
    ● Manual Operation
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Move the 3D joystick to move the pan/tilt head towards
    the desired direction.
    ● Auto Panning
    Refer to p. 8 Camera Panning Function for how to oper-
    ate.
    CAMERA CONTROL
    FA R
    FOCUS
    NEAR
    OPEN
    IRIS
    CLOSE
    Top button
    WIDE
    TELE
    Zoom wheel controller 
    						
    							5
    ■ Program Preset Position
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. To move the camera to the position to be preset, move
    the 3D joystick and press the lens control buttons.
    3. To select the desired preset position number, press the
    numeric buttons. (1 to 64)
    4. When you have selected a wrong number, press the
    CLEAR button to clear the numeric input.
    5. Press the PRESET/PGM PRESET button while holding
    down the SHIFT button to save a preset position of the
    selected camera.
    Notes:
    •If the entered position number has stored the previ-
    ous preset position, it will be overwritten by the new
    one.
    •SETUP MENU and WJ-SX150A Administrator
    Console can configure each operators pan/tilt con-
    trol. (Refer to the operating instructions of matrix
    switcher.)
    ■ Call Preset Position
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. To select the desired preset position number, press the
    numeric buttons. (1 to 64)
    3. When you have selected a wrong number, press the
    CLEAR button to clear the numeric input.
    4. Press the PRESET/PGM PRESET button to move to the
    preset position of the selected camera on the active
    monitor.
    Notes:
    •To use the above function, you must set the preset
    position number for the camera.
    •If you press no numeric buttons or the button 0 in
    Step 2, the camera will move to the home position.
    Mon1  Cam03    Pre48
           Memory
    Mon1  Cam03    Pre05 
    						
    							6
    ■ Camera Function (Shortcut
    Function)
    The following function is available only when specified cam-
    eras with the camera function feature are used.
    This function enables executing camera functions via a
    shortcut.
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the numeric buttons to select an assigned func-
    tion number, then press the CAM FUNC/SYS FUNC but-
    ton.
    For example, enter 175 for AGC ON.
    The selected function will be executed on the active
    monitor.
    Notes:
    •When you select a wrong number, press the CLEAR
    button to clear the numeric input.
    •Refer to the cameras operating instructions for
    details on available shortcuts.
    Note: This section describes the terminal mode. To operate
    in the PS·Data mode, refer to the operating instructions.
    ■Camera Setup
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the MENU button repeatedly until Camera Setup
    appears on the LCD.
    3. Press the F1 button. The cameras SETUP MENU will
    appear on the active monitor.
    4. To select the desired item in the menu, move the 3D
    joystick to 
    Cor D. To select the desired parameter (or
    mode) in the menu, move the 3D joystick to 
    Aor B.
    5. To execute the currently highlighted selection and to
    enter a submenu of SETUP MENU, press the CAM
    (SET) button.
    6. To leave from the currently selected menu and to return
    to the previous page of the menu, press the MON (ESC)
    button.
    7. Move the cursor to SPECIAL on the camera’s setup
    menu, and press the F3 button to display the special
    menu.
    8. Move the cursor to CAMERA RESET on the camera’s
    setup menu, and press the F4 button to reset all the
    functions to the defaults.
    Note:Refer to the operating instructions of the selected
    camera for details.
    9. To close the cameras SETUP MENU, press the F2 but-
    ton.
    10. To exit the mode, press the MON (ESC) button.
    CAMERA FUNCTION CONTROL
    Camera Setup     006
      On  Off  Rst A.Rst
    Camera Setup     006
     
    5On  Off  Rst A.Rst 
    						
    							7
    ■ Patrol Learn and Play
    A routine of manual operations can be stored for a specific
    time and later reproduced repetitively.
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. To save the patrol sequence, follow the procedure
    below.
    qPress the MENU button repeatedly until Patrol
    Learn will appear on the LCD.
    wPress the F1 button.
    eOperate the camera manually. 
    rPress the F2 button.
    The operation data will be saved.
    3. To reproduce the operation data, follow the procedure
    below.
    qPress the MENU button repeatedly until Auto
    Mode appears on the LCD.
    wPress the F4 button.
    eTo stop the reproduction, move the 3D joystick.
    4. To exit the mode, press the MON (ESC) button.
    Patrol Learn     007
    Start Stop
    Auto Mode        009
     Seq Sort Pan Patrol
    ■Auto Pan Setup and Activation
    You will set up and activate the auto pan function. The cam-
    era can pan between the start and end points you will set.
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the MENU button repeatedly until Auto Pan
    Setup appears on the LCD.
    3. To set the start and end point of auto pan, perform the
    following.
    qTo move the camera to a point you wish to start
    auto pan, move the 3D joystick and press the lens
    control buttons (IRIS OPEN and CLOSE, FOCUS
    FAR and NEAR).
    wPress the F3 button.
    The start point of auto pan will be set.
    eTo move the camera to a point you wish to end auto
    pan, move the 3D joystick.
    rPress the F4 button.
    The end point of auto pan will be set.
    Auto Pan Setup   008
    Play Rvrs Start End 
    						
    							8
    ■ Changing to Black and White
    Images
    This function gets the clear camera images on the monitor
    while shooting the objects under low light conditions.
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the MENU button repeatedly until BW Mode
    appears on the LCD.
    3. Press the F1 button to change the image from the color
    mode to the BW (black and white) mode on the active
    monitor.
    4. Press the F2 button to change the BW image to the
    color image on the active monitor.
    5. Press the MON (ESC) button to exit the mode.
    ■ Camera Panning Function
    There are three panning modes available as follows:
    sequence mode, sort mode, and auto pan. (Refer to the
    operating instructions of matrix switcher.)
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the MENU button repeatedly until Auto Mode
    appears on the LCD.
    3. Press the assigned function button to activate the pan-
    ning function of the selected camera.
    The LCD will indicate the selected mode as follows.
    F1:Seq (Activates SEQUENCE PAN.)
    F2:Sort (Activates SORT PAN.)
    F3:Pan (Activates AUTO PAN.)
    Note:The AUTO MODE parameter, previously set in
    the cameras SETUP MENU, will be automatically
    replaced to the activated function parameter.
    4. To exit the mode, press the MON (ESC) button.
    BW Mode          010
      On Off Auto1 Auto2Auto Mode        009
     Seq Sort Pan Patrol 
    						
    							9
    Note: This section describes the terminal mode. To operate
    in the PS·Data mode, refer to the operating instructions.
    ■Receiver Control
    The following functions are available only when the
    receivers are included in the system and the specified
    camera housing is installed.
    ● Camera Housing Control
    Wiper Control
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the WIPER button to turn on the housing wiper of
    the camera repeatedly until buttons are released.
    Defroster Control
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the DEF ON/OFF button to turn on the housing
    defroster of the camera.
    3. To turn off the defroster, press the DEF ON/OFF button
    while holding down the SHIFT button.
    ● Auxiliary Control
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. Press the AUX1 ON/OFF button to turn on the users
    auxiliary switch 1 of the receiver.
    Press the AUX1 ON/OFF button while holding down the
    SHIFT button to turn off the users auxiliary switch 1 of
    the receiver.
    3. Press the AUX2 ON/OFF button to turn on the users
    auxiliary switch 2 of the receiver.
    Press the AUX2 ON/OFF button while holding down the
    SHIFT button to turn off the users auxiliary switch 2 of
    the receiver.
    CAMERA SITE ACCESSORIES CONTROL 
    						
    							10
    Note: This section describes the terminal mode. To operate
    in the PS·Data mode, refer to the operating instructions.
    ■ Tour Sequence
    The following functions are available if a tour sequence has
    been previously configured through SETUP MENU or WJ-
    SX150A Administrator Console. Any tour sequence can be
    assigned to any monitors.
    1. Select the desired monitor and camera. (Refer to p. 3
    Monitor Selection and p. 3 Camera Selection.)
    2. To select the desired tour sequence number, press the
    numeric buttons.
    3. When you have selected a wrong number, press the
    CLEAR button to clear the numeric input.
    4. Press the TOUR SEQ/GROUP SEQ button to run the
    tour sequence in the forward direction on the active
    monitor.
    5. Press the SEQ PAUSE/SEQ STOP button to pause a
    tour sequence on the active monitor.
    The P sign (indicating the pause status) is displayed
    at the tour sequence number on the active monitor, and
    a camera number currently selected appears on the
    LCD.
    •Press the SEQ PAUSE/SEQ STOP button to restart a
    tour sequence forward from the next step that was pre-
    viously paused.
    •Press the + button to move the sequence one frame to
    the next step from the step that was previously paused.
    •Press the – button to move the sequence one frame to
    the previous step from the step that was previously
    paused.
    6. Press the SEQ PAUSE/SEQ STOP button while holding
    down the SHIFT button to stop a tour sequence on the
    active monitor and return to spot monitoring.
    ■ Group Sequence
    The following function is available only if a group sequence
    has been previously established in WJ-SX150A
    Administrator Console.
    A group sequence determines the assignment of monitors
    and cameras. Therefore, monitor selection is not required.
    1. Press the numeric buttons to select a desired group
    sequence number.
    2. When you have selected a wrong number, press the
    CLEAR button to clear the numeric input.
    3. Press the TOUR SEQ/GROUP SEQ button while holding
    down the SHIFT button to run a group sequence for-
    ward on the assigned monitors.
    4. Press the SEQ PAUSE/SEQ STOP, + or – button to
    operate the group sequence. Refer to Step 5 of Tour
    Sequence in this page for how to use these buttons. 
    5. To stop the sequence, select one of the monitors that
    are being run on the selected group sequence, then
    press the SEQ PAUSE/SEQ STOP button while holding
    down the SHIFT button
    Note:If an alarm is activated during a sequence pause, the
    sequence runs again after the matrix switcher recovers
    from the alarm mode.
    RUNNING SEQUENCE
    Mon1  Cam01
                    T04
    Mon1  Cam07
                    T04P
    Mon1  Cam01
                    T01 
    						