Page 41
42 @5Preset Position button (PRE - POSI) In combination with the numeric buttons and CAM (SET) button, moves the camera to the desired preset position. @6Still button (STILL) Freezes the picture on the multiscreen monitor. The indicator lights up when the still mode is selected. @7Camera Set buttons (CAMERA SET ON/OFF) Open or close the camera setup menu on the monitor screen. ON:Opens the selected camera setup menu on the monitor, if applicable. The indicator lights up when the camera setup menu is...
Page 42
43 INSTALLATIONS (For WJ-FS616/FS616C) The installation should be made by qualified service personnel or system installers according to the following instructions. Warning! System Connections Connection Example The connection example shows cameras and an alarm sensor connected to the Video Multiplexer. A time lapse VCR will record pictures for later playback. The spot monitor and multiscreen monitor will display live and playback pictures while these devices are being operated from System Controller...
Page 43
44 DATA Port Connection (For Multiplexer) Data ports are connected with RS-485 cables among devices using the Camera Communication protocol as follows. Note:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication. •Internal Diagram •Basic Connection DIP Switch Setting (For Multiplexer) An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an asterisk *. System...
Page 44
45 Controller Number Setting Set this switch always to 1 when using the System Controller in a system including a Multiplexer WJ- FS616/FS616C. Switch Setting Procedures 1. Remove the DC plug from the rear of the controller. 2. Set the MODE switch referring to the table. • The bit switches #1 to #3 should be set to positions that match the version of the Multiplexer installed in the sys- tem. • Bit 5 opens or terminates the communication chain. The switch should be set to OFF when the controller is...
Page 45
46 SETUP PROCEDURES (For WJ-FS616/FS616C) To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the controller as described below. Prior to Setup Do the following before entering the setup mode. 1. Confirm that all necessary connections and switch set- tings are complete. 2. With the power turned off, move bit #6 of the MODE switch on the rear to ON (administrator) position. 3. Supply power to the controller. 4. Turn on the power of cameras...
Page 46
47 Controller Setup Set up the baud rate and parity check mode for the controller while observing the LED on the front panel. Administrator Authorization 1. Press the CAM/SET button while [SEtUP] is displayed. The [- - - - -] prompt appears. 2. Enter a password with the numeric buttons, then press the CAM/SET button. The default setting is [12345]. 3. If the password entered is valid, [SPEED] appears. If password entry failed, the menu returns to [SEtUP]. Baud Rate In this menu, the communication...
Page 47
48 4. Press the ESCbutton to go back to the previous menu. Note:The baud rate and parity check mode of both the WJ-FS616/FS616C and the controller must be the same, otherwise data communications will not function. To confirm the WJ-FS616/FS616C setup, open the COM PORT SETUP window to check the DATA port column parameters. Refer to Multiplexer Setup for operation. COM PORT SETUP RS-232C DATA RS-485 DELAY OFF OFF OFF BAUD RATE 9600 9600 19200...
Page 48
49 OPERATING PROCEDURES (For WJ-FS616/FS616C System) Camera Selection One of the cameras connected to the system unit is select- ed. 1. Enter a camera number using the numeric buttons. The number appears on the LED display. 2. Press the CAM/SETbutton. Note:[--] appears in the camera section of the LED dis- play when an alarm is activated, when the multi- screen is displayed, or when sequence mode is run. The following functions of the camera are controlled. • Pan/tilt • Focus • Zoom • Iris • Defroster...
Page 49
50 Note:Auxiliary control may be ignored while zooming, focusing or panning/tilting is in operation. Alarm Operation When the WV-CU360C receives an alarm signal from the WJ-FS616/FS616C, the alarm indicator blinks. The alarm indicator changes from blinking to steady light when the alarm is automatically reset. The camera number appears in the camera section of the LED display. Alarm Reset 1. Press the ALM RESETbutton while the ALTindicator is not lit. An activated alarm is reset and the alarm indica-...
Page 50
51 Camera Setup The cameras connected to the WJ-FS616/FS616C are set up from the controller. Note: Make sure that the multiplexer and the controller are set to identical communication parameters. General Setup 1. Select a camera pressing the numeric buttons, then press the CAM/SET button. 2. Press the CAMERA SET ONbutton. The ON indicator is lit while the CAMERA SET UP MENU is displayed on the monitor. 3. Select a setup item by moving the joystick up and down. Select a parameter by moving the joystick...