Page 11

11
oIris buttons (IRIS, CLOSE/OPEN)
Close or open the lens iris of cameras equipped with
the specified lens.
When these buttons are pressed simultaneously, the
lens iris is reset to the factory default setting.
!0Focus buttons (FOCUS, NEAR/FAR)
Adjust the lens focus of cameras equipped with the
specified lens.
When these buttons are pressed simultaneously, the
lens focus is set automatically if the specified camera is
used.
!1Zoom buttons (ZOOM, WIDE/TELE)
Zoom the image in or out if the camera is...

Page 12

12
@2Defroster/Auxiliary 2 button (DEF/AUX 2)
Activates the housing defroster of cameras provided
with this feature. Pressing this button in the shift mode
will turn on the AUX 2 function controlling accessories
connected to the cameras or the system.
The LED next to the button is lit while the defroster or
AUX 2 function operates.
@3Wiper/Auxiliary 1 button (WIPER/AUX 1)
Activates the housing wiper of cameras provided with
this feature. Pressing this button in the shift mode will
turn on the AUX 1...

Page 13

13
INSTALLATIONS (PS•Data)
The installation should be made by qualified service personnel or system installers according to the following instructions.
CAUTION
System Connections
Connection Example
Example 1 shows 8 cameras connected to 2 Data Multiplex Units (WJ-MP204C), to a Video Multiplexer (e.g., WJ-FS316) and a
Digital Disk Recorder (e.g., WJ-HD100). The WV-CU360C controls these system units through RS-485 communication while
pictures are viewed on the monitors.
SIGNAL
GNDALARM/REMOTEOUTIN
VIDEO...

Page 14

14
DATA Port Connection (PS•Data)
Data ports are connected with RS-485 cables among devices using the PS•Data protocol as follows.
Notes:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485
communication.
•Internal Diagram
•Basic Connection Example 2 shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers.
System ControllerWV-CU360System ControllerWV-CU360UP
LR
DOWNSystem ControllerWV-CU360
Data...

Page 15

15
SW position •Daisy Chain Connection
DIP Switch Setting (PS•Data)
An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an
asterisk *.
D ATA
Data Multiplex Unit
WJ-MP204C
Branch
Cable Termination:
OFF Termination:
ONSystem Controller
WV-CU360C
D ATA  D ATA
Video Multiplexer
WJ-FS309 (WJ-FS316)
RS-485
CableTermination:
ON
RS-485
Cable
MODE
123456 78
OFF
ON
OFF
Not used Function
ON
Bit 6 Bit 7
Bit 8
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1Operation...

Page 16

16
MODE Switch Setting for System Example 2
The MODE switch needs to be set prior to operating a sys-
tem connected as shown in Example 2.
Bit 3 should be set to OFF.
Bit 5 should be set to OFF when the controller is placed
in an intermediate position, or set to ON when it is con-
nected at the chain end.
Controller Number Setting (PS•Data)
A 10-position rotary switches provided on the rear for spec-
ifying the unit number of the WV-CU360C controller in a
PS
•Data system.
1. Remove the DC plug from the...

Page 17

17
CONTROLLER SETUP PROCEDURES (PS•Data)
To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the
controller as described below.
Prior to Setup
Do the following before entering the setup mode.
1. Confirm that all necessary connections and switch set-
tings are complete.
2. With the power turned off, move bit #6 of the MODE
switch on the rear to ON (administrator) position.
3. Supply power to the controller.
4. Turn on the power of cameras...

Page 18

18
Setup Menus
There are 12 setup menus as shown below.
Menu 
Selection
Move Joystick up
and down to selectSetup Menus
Parameter Selection (default*)
LED Display
blinking
Setup
Administrator
Password
Prompt
Speed
Parity
Wait
Controller
Unit
Group
System
Unit
Group
Unit A
Number
Unit B
Number
User
Password
Super
User
Password
User
Certification
Cleaning
Unit
TestInitial
Display
Authorization
Baud Rate
(bps)Press
twice
Parity Check
Wait Time
(ms)
Unit
Assignment to
Button A
Unit
Assignment to
Button B...

Page 19

19
Administrator Authorization
1. Press the CAM/SET button while [SEtUP] is displayed.
The [- - - - -] prompt appears.
2. Enter a password with the numeric buttons, then press
the CAM/SET button.
The default setting is [12345].
3. [SPEED] appears when the right password is entered. If
password entry failed, the menu returns to [- - - - -].
Notes: 
• We recommend that you register a new password dif-
ferent from “12345” in [SUSrP], and note down the reg-
istered password for future reference.
• Powering...

Page 20

20
Unit A button Assignment
In this menu, a maximum of 9 system units is assigned to
numeric buttons 1-9 regardless of unit address. 
This is to avoid double-digit unit addresses which can
occur in a large system with many units connected and
could confuse operators.
A frequently used system unit can be easily selected in nor-
mal operation by pressing one numeric button and then the
UNIT A button.
1. Display [UA-no] and press the CAM/SET button. The
LED displays [A1-01] while “1” following A blinks....