Panasonic System Controller Wv Cu360c Operating Instructions
Here you can view all the pages of manual Panasonic System Controller Wv Cu360c Operating Instructions. The Panasonic manuals for Controller are available online for free. You can easily download all the documents as PDF.
Page 11
11 oIris buttons (IRIS, CLOSE/OPEN) Close or open the lens iris of cameras equipped with the specified lens. When these buttons are pressed simultaneously, the lens iris is reset to the factory default setting. !0Focus buttons (FOCUS, NEAR/FAR) Adjust the lens focus of cameras equipped with the specified lens. When these buttons are pressed simultaneously, the lens focus is set automatically if the specified camera is used. !1Zoom buttons (ZOOM, WIDE/TELE) Zoom the image in or out if the camera is...
Page 12
12 @2Defroster/Auxiliary 2 button (DEF/AUX 2) Activates the housing defroster of cameras provided with this feature. Pressing this button in the shift mode will turn on the AUX 2 function controlling accessories connected to the cameras or the system. The LED next to the button is lit while the defroster or AUX 2 function operates. @3Wiper/Auxiliary 1 button (WIPER/AUX 1) Activates the housing wiper of cameras provided with this feature. Pressing this button in the shift mode will turn on the AUX 1...
Page 13
13 INSTALLATIONS (PS•Data) The installation should be made by qualified service personnel or system installers according to the following instructions. CAUTION System Connections Connection Example Example 1 shows 8 cameras connected to 2 Data Multiplex Units (WJ-MP204C), to a Video Multiplexer (e.g., WJ-FS316) and a Digital Disk Recorder (e.g., WJ-HD100). The WV-CU360C controls these system units through RS-485 communication while pictures are viewed on the monitors. SIGNAL GNDALARM/REMOTEOUTIN VIDEO...
Page 14
14 DATA Port Connection (PS•Data) Data ports are connected with RS-485 cables among devices using the PS•Data protocol as follows. Notes:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication. •Internal Diagram •Basic Connection Example 2 shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers. System ControllerWV-CU360System ControllerWV-CU360UP LR DOWNSystem ControllerWV-CU360 Data...
Page 15
15 SW position •Daisy Chain Connection DIP Switch Setting (PS•Data) An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an asterisk *. D ATA Data Multiplex Unit WJ-MP204C Branch Cable Termination: OFF Termination: ONSystem Controller WV-CU360C D ATA D ATA Video Multiplexer WJ-FS309 (WJ-FS316) RS-485 CableTermination: ON RS-485 Cable MODE 123456 78 OFF ON OFF Not used Function ON Bit 6 Bit 7 Bit 8 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1Operation...
Page 16
16 MODE Switch Setting for System Example 2 The MODE switch needs to be set prior to operating a sys- tem connected as shown in Example 2. Bit 3 should be set to OFF. Bit 5 should be set to OFF when the controller is placed in an intermediate position, or set to ON when it is con- nected at the chain end. Controller Number Setting (PS•Data) A 10-position rotary switches provided on the rear for spec- ifying the unit number of the WV-CU360C controller in a PS •Data system. 1. Remove the DC plug from the...
Page 17
17 CONTROLLER SETUP PROCEDURES (PS•Data) To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the controller as described below. Prior to Setup Do the following before entering the setup mode. 1. Confirm that all necessary connections and switch set- tings are complete. 2. With the power turned off, move bit #6 of the MODE switch on the rear to ON (administrator) position. 3. Supply power to the controller. 4. Turn on the power of cameras...
Page 18
18 Setup Menus There are 12 setup menus as shown below. Menu Selection Move Joystick up and down to selectSetup Menus Parameter Selection (default*) LED Display blinking Setup Administrator Password Prompt Speed Parity Wait Controller Unit Group System Unit Group Unit A Number Unit B Number User Password Super User Password User Certification Cleaning Unit TestInitial Display Authorization Baud Rate (bps)Press twice Parity Check Wait Time (ms) Unit Assignment to Button A Unit Assignment to Button B...
Page 19
19 Administrator Authorization 1. Press the CAM/SET button while [SEtUP] is displayed. The [- - - - -] prompt appears. 2. Enter a password with the numeric buttons, then press the CAM/SET button. The default setting is [12345]. 3. [SPEED] appears when the right password is entered. If password entry failed, the menu returns to [- - - - -]. Notes: • We recommend that you register a new password dif- ferent from “12345” in [SUSrP], and note down the reg- istered password for future reference. • Powering...
Page 20
20 Unit A button Assignment In this menu, a maximum of 9 system units is assigned to numeric buttons 1-9 regardless of unit address. This is to avoid double-digit unit addresses which can occur in a large system with many units connected and could confuse operators. A frequently used system unit can be easily selected in nor- mal operation by pressing one numeric button and then the UNIT A button. 1. Display [UA-no] and press the CAM/SET button. The LED displays [A1-01] while “1” following A blinks....