Panasonic System Controller Wv Cu360c Operating Instructions
Have a look at the manual Panasonic System Controller Wv Cu360c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 oIris buttons (IRIS, CLOSE/OPEN) Close or open the lens iris of cameras equipped with the specified lens. When these buttons are pressed simultaneously, the lens iris is reset to the factory default setting. !0Focus buttons (FOCUS, NEAR/FAR) Adjust the lens focus of cameras equipped with the specified lens. When these buttons are pressed simultaneously, the lens focus is set automatically if the specified camera is used. !1Zoom buttons (ZOOM, WIDE/TELE) Zoom the image in or out if the camera is equipped with the specified lens. !2Unit A/UNIT button (UNIT A/UNIT) Selects a specific system unit in a multiple unit system. To select a unit, press this button after entering the unit number with the numeric button. To confirm a unit num- ber, press this button after pressing the SHIFT button. The selected unit address appears on the LED display. The unit that is assigned to number 1 can be selected by pressing this button. !3Unit B button (UNIT B) Selects a specific system unit in a multiple unit system. To select a unit, press this button after entered the unit number with the numeric button. The selected unit address appears on the LED display. Just pressing this button will select the system unit assigned the number 1. !4Home/Preset/Programme Preset button (HOME/PRESET/PROGRAM PRESET) Returns a specific camera to its home position. In combination with the numeric buttons, this button is also used to recall a preset position assigned to a spe- cific camera. Pressing it while holding down the Programme/Camera Setup/Camera Function button will programme the pre- set position. !5Numeric buttons (0-9) These buttons are used for numeric input, such as cam- era, monitor and unit numbers, and preset positions. !6Camera/Set button (CAM/SET) CAM:Used for camera selection. To select a camera, enter the desired camera number with the numeric buttons, and then press this button. SET:Executes the currently highlighted setting in the setup menu. Pressing this button together with the MON/ESC button for approximately 2 seconds will log out from the sys- tem.!7Monitor/Escape button (MON/ESC) MON:Used for monitor selection and confirmation. To select a monitor, enter the desired monitor number with the numeric buttons, and then press this but- ton. The selected monitor number appears on the LED display. To confirm a monitor number, simply press this but- ton. ESC:Used to escape from the currently highlighted selection and return to the previous menu of the setup menu. Pressing this button together with the CAM/SET button for approximately 2 seconds will log out from the sys- tem. !8Programme/Camera Setup/Camera Function button (PROGRAM/CAM SETUP/CAM FUNCTION) Programmes camera patrol learning and preset position functions. Pressing this button for 2 seconds or more will open the camera setup menu. Pressing it in combination with the numeric buttons after pressing the shift button will exe- cute camera functions. The LED next to the button is lit during the camera setup operation. !9Setup/Function button (SETUP/FUNCTION) Pressing this button for 2 seconds or more will open the setup menu of a system unit. When the SHIFT indicator is lit, it provides access to the functions of the system unit. Enter a function number with the numeric keys, then press this button. The LED next to the button is lit during the setup opera- tion. @0Shift button (SHIFT) Shifts the button function between the normal and the shift mode shown in half-tone print under the button on the template. The LED next to the button is lit in the shift mode. @1Auto Panning/Black and White button (AUTO/B/W) Activates the auto panning function of cameras provid- ed with this feature. Pressing this button in the shift mode will change the camera picture from color to black and white for better viewing in a dark place. AUTO PAN ON or combination camera function: Simply press this button, or press numeric button 1 followed by this button. AUTO SORT ON:Press numeric button 2 followed by this button. AUTO SEQ ON:Press numeric button 3 followed by this button. RANDOM PAN ON:Press numeric button 4 followed by this button.
12 @2Defroster/Auxiliary 2 button (DEF/AUX 2) Activates the housing defroster of cameras provided with this feature. Pressing this button in the shift mode will turn on the AUX 2 function controlling accessories connected to the cameras or the system. The LED next to the button is lit while the defroster or AUX 2 function operates. @3Wiper/Auxiliary 1 button (WIPER/AUX 1) Activates the housing wiper of cameras provided with this feature. Pressing this button in the shift mode will turn on the AUX 1 function controlling accessories con- nected to the cameras or the system. The LED next to the button is lit while the wiper or AUX 1 function operates. @4Patrol Play/Patrol Learn button (PATROL PLAY/ PATROL LEARN) Starts the camera patrol play. While holding down the Programme/Camera setup/Camera Function button, pressing this button will start to programme the camera patrol learning. @5Alarm Suspend button (ALM SUSPEND) Suspends or allows the alarm process. The LED next to the button is lit while the alarm suspen- sion mode operates. @6Alarm Reset/Alarm Recall button (ALM RESET/ALM RECALL) Resets system alarm when the alarm function is active. Pressing this button in the SHIFT mode will recall the alarm logs (record of alarms activated in the past). Select a monitor, and then press this button to display the alarm logs on the monitor screen. Pressing this but- ton after pressing the shift button again will cancel the function. The LED next to the button is lit while Alarm Recall mode is activated. @7Multiscreen Selection button (MULTI SCREEN SELECT) Selects the number of segments into which the multi- screen is split on the selected monitor connected to the MULTISCREEN OUT terminal of the Video Multiplexer. @8VCR/Camera Selection button ( VCR/ CAM) Changes the display on the multiscreen monitor between the live picture of a camera and the playback picture of a recording device. The LED next to the but- ton is lit while VCR is selected.@9Electronic Zoom/Increment button (EL-ZOOM/+) Zooms the camera picture or VCR playback picture dis- played on the multiscreen monitor. Pressing this button in the shift mode will move the camera sequence one step forward from the step previ- ously paused while a system unit provided with SEQ PAUSE (e.g., a Video Multiplexer) is selected. Pressing this button in the shift mode will select the pic- ture of camera with the next higher number for display on the monitor while a system unit connected with cam- eras (e.g., a Data Multiplex Unit) is selected. The LED next to the button is lit while Electronic Zoom mode is selected. #0Still/Decrement button (STILL/–) Freezes the camera picture or VCR playback picture on the multiscreen monitor. Pressing this button in the shift mode will move the camera sequence one step backward from the step previously paused while a system unit (e.g., a Video Multiplexer) provided with SEQ PAUSE is selected. Pressing this button in the shift mode will select the pic- ture of the camera with the next lower number for dis- play on the monitor while a system unit connected with cameras (e.g., a Data Multiplex Unit) is selected. The LED next to the button is lit while a still picture is displayed. #1Sequence/Patrol Stop button (SEQUENCE/PATROL STOP) Runs or stops a preset sequence in which a series of camera pictures is displayed in succession on the mon- itor screen for the specified duration. Pressing it while holding down the Programme/Camera Setup/Camera Function button will stop programming of camera patrol learning. The LED next to the button is lit while a sequence runs. #2Sequence Pause/Slow button (SEQ PAUSE/SLOW) Pauses a sequence running on the selected monitor. In this mode, a series of camera pictures is displayed in pause on the monitor screen for the specified duration. Pressing this button while moving the joystick controller will decrease the pan/tilt speed.
13 INSTALLATIONS (PS•Data) The installation should be made by qualified service personnel or system installers according to the following instructions. CAUTION System Connections Connection Example Example 1 shows 8 cameras connected to 2 Data Multiplex Units (WJ-MP204C), to a Video Multiplexer (e.g., WJ-FS316) and a Digital Disk Recorder (e.g., WJ-HD100). The WV-CU360C controls these system units through RS-485 communication while pictures are viewed on the monitors. SIGNAL GNDALARM/REMOTEOUTIN VIDEO 16 15 14 13 12 11 10 9 8 16 15 14 13 12 11 10 9 87654 21 765433 21 PLAY INREC OUTSPOT OUT D ATACAMERA SW INMULTI SCREEN OUT SD RD IN IN CAMERA RS485 A B A B GVS/VD SPOT DATAALARM / REMOTE MODESIGNAL GND 43 21 OUT OUT IN OUT43 21TR IN IN CAMERA RS485 A B A B GVS/VD SPOT DATAALARM / REMOTE MODESIGNAL GND 43 21 OUT OUT IN OUT43 21 Camera No. 1 Camera No. 2 Camera No. 3 Camera No. 4 Camera No. 5 Camera No. 6 Camera No. 7 Camera No. 8 VS/VD INPUT Unit Address 1 Unit Address 2 WJ-MP204C WJ-MP204C WJ-FS316 WJ-HD100Unit Address 3 Unit Address 4 Video Signal 6-conductor Modular Cable (supplied) Termination ON MODE VS/VD OUTPUT 4-Line Monitor No. 1 Monitor No. 2 Panasonic Security Data modeTermination OFF Panasonic Security Data mode4-Line MODE VD OUT RS-485 Signal (Panasonic Security Data Mode) SIGNAL GND ALARM SERIES RECORD TIME ADJUSTREMOTEMODE DATA RS-232C VIDEO OUTIN OUTIN AUDIOMONITOR OUT (PLAY) CAMERA SW OUTG G GPOWER ON OFFJOG-CLICK JOG-LEFT JOG-RIGHTALARM SEARCHSTEP REW/FF STOP/SETUP PLAY REC OUT PLAY OUT REC OUTAUTO OFF OUTDISK END OUT IN OUT IN RECALL (EXT REC) OUTRECOVER OUTRESET IN IN PLAY IN PLAY VIDEO IN REC OUT RS-485 Cable Branch Cable Up to four WV-CU360C can be used in a system. DC 9V IND ATA MODE CONTROLLER No.0987654321 0987654321 Keep in OFF position Keep in OFF position Termination ON Set to OFF position (for operator mode) Controller No. 1 Refer to DIP switch setting on page 15 CONTROLLER No.
14 DATA Port Connection (PS•Data) Data ports are connected with RS-485 cables among devices using the PS•Data protocol as follows. Notes:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication. •Internal Diagram •Basic Connection Example 2 shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers. System ControllerWV-CU360System ControllerWV-CU360UP LR DOWNSystem ControllerWV-CU360 Data Multiplex Unit WJ-MP204CData Multiplex Unit WJ-MP204Data Multiplex Unit WJ-MP204 WJ-MP204C WV-CU360C 4 cameras can be connected to one Data Multiplex Unit UP LR DOWN UP LR DOWN Up to 4 Data Multiplex Units Up to 4 System Controllers Channel 1 Channel 2 Channel 4 Channel 13 Channel 14 Channel 16 Unit address 1 Controller No. 1Controller No. 2 Controller No. 4 Unit address 2Unit address 4 See page 16 for MODE switch and CONTROLLER NO. switch settings. D ATA Data Multiplex Unit WJ-MP204CSystem Controller WV-CU360C D ATA RS-485 Cable Termination: ONTermination: ON Data Flow – WJ-MP204C ← WV-CU360C WJ-MP204C ← WV-CU360C WJ-MP204C → WV-CU360C WJ-MP204C → WV-CU360C – 1 61 6 No.No. 11 22 33 44 55 66 Name GND TX(B) TX(A) RX(B) RX(A) GND Controller endTX (B) TX (A) RX (A) RX (B)
15 SW position •Daisy Chain Connection DIP Switch Setting (PS•Data) An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an asterisk *. D ATA Data Multiplex Unit WJ-MP204C Branch Cable Termination: OFF Termination: ONSystem Controller WV-CU360C D ATA D ATA Video Multiplexer WJ-FS309 (WJ-FS316) RS-485 CableTermination: ON RS-485 Cable MODE 123456 78 OFF ON OFF Not used Function ON Bit 6 Bit 7 Bit 8 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1Operation mode Baud rate selection Data transmission mode Line termination Reserved System Unit Version System Unit Version System Unit VersionOperator* Fixed to OFF* Fixed to OFF* Off Fixed to OFF* Fixed to OFF* Fixed to OFF* Fixed to OFF*Administrator Not used Not used On* Not used Not used Not used 1. Remove the DC plug from the rear of the controller. 2. Set the switch referring to the table. 3. Connect the DC plug to the controller. Notes: • Bits 1 - 4 are reserved. • Bit 5 opens or terminates the communication chain. The switch should be set to OFF when the controller is located in an intermediate position. • Bit 6 specifies the operation mode, Operator or Administrator. The switch should be set to Administrator when setting up the controller. Remember to set this switch to the right position after completion of the setup operation. • Bits 7 and 8 are used in the OFF position.
16 MODE Switch Setting for System Example 2 The MODE switch needs to be set prior to operating a sys- tem connected as shown in Example 2. Bit 3 should be set to OFF. Bit 5 should be set to OFF when the controller is placed in an intermediate position, or set to ON when it is con- nected at the chain end. Controller Number Setting (PS•Data) A 10-position rotary switches provided on the rear for spec- ifying the unit number of the WV-CU360C controller in a PS •Data system. 1. Remove the DC plug from the rear of the controller. 2. Use a screw driver to rotate the switch so that the arrow comes to the number you wish. 3. Connect the DC plug to the controller. Notes: • Set the switch to #1 when a single controller is used in the system. • Specify a unique number for each controller when con- necting multiple controllers in the system. One con- troller within the multiple controller system must be assigned the number 1. • Positions #0 and #9 are reserved and cannot be used. 0987654321 CONTROLLER No. Controller No. Switch of WV-CU360C Controller No. 0 Reserved 11 22 33 44 55 66 77 88 9 Reserved 123456 78 OFF ON
17 CONTROLLER SETUP PROCEDURES (PS•Data) To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the controller as described below. Prior to Setup Do the following before entering the setup mode. 1. Confirm that all necessary connections and switch set- tings are complete. 2. With the power turned off, move bit #6 of the MODE switch on the rear to ON (administrator) position. 3. Supply power to the controller. 4. Turn on the power of cameras and other system units. 5. The LCD displays [SEtUP]. The controller is ready to enter the setup mode. When setup is completed, restore the switch to its original position. 1. With the power turned off, move bit #6 of the MODE switch on the rear to OFF (operator) position. 2. Supply power to the controller. Buttons and Controls used for Setup The following buttons and joystick operations are used in the setup operation. There are three ways to select a para- meter, but the following pages only describe the selection by use of the joystick. Instead of operating the joystick, you can enter the number enclosed in brackets with the numer- ic keys or press the plus and minus buttons. 0 9 Numeric buttons: To select a parameter To enter a password or parameter CAM/SET button: To confirm the selected menu, selected parame- ter or entered password To enter a submenu MON/ESC button: To return to the previous menu CAM SET MON ESC DOWN LRUP LR UP DOWNR UP DOWN LR Up: To select a setup menu Down: To select a setup menu Left: To decrease the parameter Right: To increase the parameter EL-ZOOM STILL – + or or
18 Setup Menus There are 12 setup menus as shown below. Menu Selection Move Joystick up and down to selectSetup Menus Parameter Selection (default*) LED Display blinking Setup Administrator Password Prompt Speed Parity Wait Controller Unit Group System Unit Group Unit A Number Unit B Number User Password Super User Password User Certification Cleaning Unit TestInitial Display Authorization Baud Rate (bps)Press twice Parity Check Wait Time (ms) Unit Assignment to Button A Unit Assignment to Button B Administrator Password User Authorization Camera Cleaning Unit Connection Test CAM SET CAM SET MON ESC CAM SET LED prompts you to enter a pass- word Enter a 5-digit password, press (12345*) (1) 2 400 (2) 4 800 (3) 9 600* (4) 19 200 (1) None* (2) Even (1) Off* (2) 100 (3) 200 (4) 400 (5) 1 000 Leave as it is Leave as it is Enter a 5-digit number, press (12345*) Reading Function OK No DOWN LR UP LR CAM SET CAM SET Enter a 5-digit number, press (12345*) (1) Off (2) On*CAM SET
19 Administrator Authorization 1. Press the CAM/SET button while [SEtUP] is displayed. The [- - - - -] prompt appears. 2. Enter a password with the numeric buttons, then press the CAM/SET button. The default setting is [12345]. 3. [SPEED] appears when the right password is entered. If password entry failed, the menu returns to [- - - - -]. Notes: • We recommend that you register a new password dif- ferent from “12345” in [SUSrP], and note down the reg- istered password for future reference. • Powering up the controller while holding down numeric buttons 2, 4 and 5 simultaneously will reset the pass- word to “12345”. Remember that this procedure also resets all other menu parameters to the default settings. Baud Rate In this menu, the communication speed (bps: bits per sec- ond) is selected. The communication speed should match that of the other units connected in the communication chain. 1. Display [SPEED] and press the CAM/SET button twice. 2. Select a parameter entering a bracket-enclosed num- ber, e.g., (3), moving the joystick right and left, or pressing the [+] and [–] button. The default setting is 19 200 bps. (1) 2 400:2 400 bps (2) 4 800:4 800 bps (3) 9 600:9 600 bps (4) 19 200:19 200 bps Note:Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an acti- vated alarm is reset). 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. Parity In this menu, the parity check mode is selected. 1. Display [PrtY] and press the CAM/SET button twice. 2. Select a parameter with the joystick. The default setting is None. n:None E:Even parity 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. Wait Time In this menu a wait time is selected. The controller will retransmit data when there is no response during the speci- fied wait time. 1. Display [LJAit] and press the CAM/SET button twice. 2. Select a parameter with the joystick. The default setting is Off. (1) OFF:Off, no retransmission of data (2) 100:100 ms (3) 200:200 ms (4) 400:400 ms (5) 500:500 ms (6) 1 000:1 s 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. The following two menus should be maintained in the default condition. Controller Unit-Group Address [CU-gr] appears on the Setup menu, but leave the default as it is. System Unit-Group Address [SU-gr] appears on the Setup menu, but leave the default as it is.
20 Unit A button Assignment In this menu, a maximum of 9 system units is assigned to numeric buttons 1-9 regardless of unit address. This is to avoid double-digit unit addresses which can occur in a large system with many units connected and could confuse operators. A frequently used system unit can be easily selected in nor- mal operation by pressing one numeric button and then the UNIT A button. 1. Display [UA-no] and press the CAM/SET button. The LED displays [A1-01] while “1” following A blinks. The first 2 digits from A1 to A9, “A numbers”, stand for numeric buttons from 1 to 9 to be pressed prior to UNIT A button in normal operation. The next 2 digits are the unit address assigned in the following procedures. The default setting is shown below. A1-01 A2-02 A3-03 A1-04 A5-05 A6-06 A7-07 A8-08 A9-09 2. Select an “A number” entering a number from 1 to 9, then press the CAM/SET button. The LED displays “A number” A3 when numeric button 3 is entered for example. Available A numbers:1-9 3. Press the CAM/SET button to validate the selection. The LED displays [A3-03] while the next two digits are blink- ing. 4. Enter a 2-digit unit address that you wish to assign to the “A number” (e.g., A3), then press the CAM/SET but- ton. The LED displays [A3-99], for example, when you enter unit address 99. Available addresses:01-99 5. Press the CAM/SET button to validate the selection. Repeat above the steps 2 to 5 as needed. 6. Press the ESC button to go back to the previous menu. Unit B button Assignment The UNIT B button is set up in the same way as the UNIT A button for use in normal operation. Refer to the above description for Unit A button Assignment. User Password In this menu, a 5-digit password for user authorization is registered. 1. Display [UsrP ] and press the CAM/SET button. The LED displays the registered password. 2. Enter a 5-digit password with the numeric buttons. The default setting is [12345]. Available password digits: 00000-99999 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. Administrator Password In this menu, a 5-digit password for administrator certifica- tion is registered. 1. Display [SUsrP] and press the CAM/SET button. The LED displays the registered password. 2. Enter a 5-digit password with the numeric buttons. The default setting is [12345]. Available password digits:00000-99999 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. User Password Certification In this menu, password certification in normal operation is enabled or disabled. 1. Display [USr-C] and press the CAM/SET button. The LED displays [UC-on] or [UC-oF]. 2. Select On or Off with the joystick controller. The default setting is On. on:Password certification enabled. oF:Password certification disabled. 3. Press the CAM/SET button to confirm the selection. 4. Press the ESC button to go back to the previous menu.