    Have a look at the manual Panasonic System Controller Wv Cu360c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    oIris buttons (IRIS, CLOSE/OPEN)
    Close or open the lens iris of cameras equipped with
    the specified lens.
    When these buttons are pressed simultaneously, the
    lens iris is reset to the factory default setting.
    !0Focus buttons (FOCUS, NEAR/FAR)
    Adjust the lens focus of cameras equipped with the
    specified lens.
    When these buttons are pressed simultaneously, the
    lens focus is set automatically if the specified camera is
    used.
    !1Zoom buttons (ZOOM, WIDE/TELE)
    Zoom the image in or out if the camera is equipped with
    the specified lens.
    !2Unit A/UNIT button (UNIT A/UNIT)
    Selects a specific system unit in a multiple unit system.
    To select a unit, press this button after entering the unit
    number with the numeric button. To confirm a unit num-
    ber, press this button after pressing the SHIFT button.
    The selected unit address appears on the LED display.
    The unit that is assigned to number 1 can be selected
    by pressing this button.
    !3Unit B button (UNIT B)
    Selects a specific system unit in a multiple unit system.
    To select a unit, press this button after entered the unit
    number with the numeric button. The selected unit
    address appears on the LED display.
    Just pressing this button will select the system unit
    assigned the number 1.
    !4Home/Preset/Programme Preset button
    (HOME/PRESET/PROGRAM PRESET)
    Returns a specific camera to its home position.
    In combination with the numeric buttons, this button is
    also used to recall a preset position assigned to a spe-
    cific camera.
    Pressing it while holding down the Programme/Camera
    Setup/Camera Function button will programme the pre-
    set position.
    !5Numeric buttons (0-9)
    These buttons are used for numeric input, such as cam-
    era, monitor and unit numbers, and preset positions.
    !6Camera/Set button (CAM/SET)
    CAM:Used for camera selection. To select a camera,
    enter the desired camera number with the numeric
    buttons, and then press this button.
    SET:Executes the currently highlighted setting in the
    setup menu.
    Pressing this button together with the MON/ESC button
    for approximately 2 seconds will log out from the sys-
    tem.!7Monitor/Escape button (MON/ESC)
    MON:Used for monitor selection and confirmation. To
    select a monitor, enter the desired monitor number
    with the numeric buttons, and then press this but-
    ton. The selected monitor number appears on the
    LED display.
    To confirm a monitor number, simply press this but-
    ton.
    ESC:Used to escape from the currently highlighted
    selection and return to the previous menu of the
    setup menu.
    Pressing this button together with the CAM/SET button
    for approximately 2 seconds will log out from the sys-
    tem.
    !8Programme/Camera Setup/Camera Function button
    (PROGRAM/CAM SETUP/CAM FUNCTION)
    Programmes camera patrol learning and preset position
    functions.
    Pressing this button for 2 seconds or more will open the
    camera setup menu. Pressing it in combination with the
    numeric buttons after pressing the shift button will exe-
    cute camera functions. 
    The LED next to the button is lit during the camera
    setup operation.
    !9Setup/Function button (SETUP/FUNCTION)
    Pressing this button for 2 seconds or more will open the
    setup menu of a system unit. 
    When the SHIFT indicator is lit, it provides access to the
    functions of the system unit.  Enter a function number
    with the numeric keys, then press this button.
    The LED next to the button is lit during the setup opera-
    tion.
    @0Shift button (SHIFT)
    Shifts the button function between the normal and the
    shift mode shown in half-tone print under the button on
    the template.  The LED next to the button is lit in the
    shift mode.
    @1Auto Panning/Black and White button (AUTO/B/W)
    Activates the auto panning function of cameras provid-
    ed with this feature. Pressing this button in the shift
    mode will change the camera picture from color to
    black and white for better viewing in a dark place.
    AUTO PAN ON or combination camera function:
    Simply press this button, or press numeric button 1
    followed by this button.
    AUTO SORT ON:Press numeric button 2 followed by
    this button.
    AUTO SEQ ON:Press numeric button 3 followed by
    this button.
    RANDOM PAN ON:Press numeric button 4 followed by
    this button. 
    						
    							12
    @2Defroster/Auxiliary 2 button (DEF/AUX 2)
    Activates the housing defroster of cameras provided
    with this feature. Pressing this button in the shift mode
    will turn on the AUX 2 function controlling accessories
    connected to the cameras or the system.
    The LED next to the button is lit while the defroster or
    AUX 2 function operates.
    @3Wiper/Auxiliary 1 button (WIPER/AUX 1)
    Activates the housing wiper of cameras provided with
    this feature. Pressing this button in the shift mode will
    turn on the AUX 1 function controlling accessories con-
    nected to the cameras or the system.
    The LED next to the button is lit while the wiper or AUX
    1 function operates.
    @4Patrol Play/Patrol Learn button (PATROL PLAY/
    PATROL LEARN)
    Starts the camera patrol play. While holding down the
    Programme/Camera setup/Camera Function button,
    pressing this button will start to programme the camera
    patrol learning.
    @5Alarm Suspend button (ALM SUSPEND)
    Suspends or allows the alarm process.
    The LED next to the button is lit while the alarm suspen-
    sion mode operates.
    @6Alarm Reset/Alarm Recall button (ALM RESET/ALM
    RECALL)
    Resets system alarm when the alarm function is active.
    Pressing this button in the SHIFT mode will recall the
    alarm logs (record of alarms activated in the past).
    Select a monitor, and then press this button to display
    the alarm logs on the monitor screen. Pressing this but-
    ton after pressing the shift button again will cancel the
    function. 
    The LED next to the button is lit while Alarm Recall
    mode is activated.
    @7Multiscreen Selection button (MULTI SCREEN
    SELECT)
    Selects the number of segments into which the multi-
    screen is split on the selected monitor connected to the
    MULTISCREEN OUT terminal of the Video Multiplexer.
    @8VCR/Camera Selection button ( VCR/ CAM)
    Changes the display on the multiscreen monitor
    between the live picture of a camera and the playback
    picture of a recording device.  The LED next to the but-
    ton is lit while VCR is selected.@9Electronic Zoom/Increment button (EL-ZOOM/+)
    Zooms the camera picture or VCR playback picture dis-
    played on the multiscreen monitor.
    Pressing this button in the shift mode will move the
    camera sequence one step forward from the step previ-
    ously paused while a system unit provided with SEQ
    PAUSE (e.g., a Video Multiplexer) is selected.
    Pressing this button in the shift mode will select the pic-
    ture of camera with the next higher number for display
    on the monitor while a system unit connected with cam-
    eras (e.g., a Data Multiplex Unit) is selected.
    The LED next to the button is lit while Electronic Zoom
    mode is selected.
    #0Still/Decrement button (STILL/–)
    Freezes the camera picture or VCR playback picture on
    the multiscreen monitor.
    Pressing this button in the shift mode will move the
    camera sequence one step backward from the step
    previously paused while a system unit (e.g., a Video
    Multiplexer) provided with SEQ PAUSE is selected.
    Pressing this button in the shift mode will select the pic-
    ture of the camera with the next lower number for dis-
    play on the monitor while a system unit connected with
    cameras (e.g., a Data Multiplex Unit) is selected.
    The LED next to the button is lit while a still picture is
    displayed.
    #1Sequence/Patrol Stop button (SEQUENCE/PATROL
    STOP)
    Runs or stops a preset sequence in which a series of
    camera pictures is displayed in succession on the mon-
    itor screen for the specified duration. Pressing it while
    holding down the Programme/Camera Setup/Camera
    Function button will stop programming of camera patrol
    learning.
    The LED next to the button is lit while a sequence runs.
    #2Sequence Pause/Slow button (SEQ PAUSE/SLOW)
    Pauses a sequence running on the selected monitor. In
    this mode, a series of camera pictures is displayed in
    pause on the monitor screen for the specified duration.
    Pressing this button while moving the joystick controller
    will decrease the pan/tilt speed. 
    						
    							13
    INSTALLATIONS (PS•Data)
    The installation should be made by qualified service personnel or system installers according to the following instructions.
    CAUTION
    System Connections
    Connection Example
    Example 1 shows 8 cameras connected to 2 Data Multiplex Units (WJ-MP204C), to a Video Multiplexer (e.g., WJ-FS316) and a
    Digital Disk Recorder (e.g., WJ-HD100). The WV-CU360C controls these system units through RS-485 communication while
    pictures are viewed on the monitors.
    SIGNAL
    GNDALARM/REMOTEOUTIN
    VIDEO 16 15 14 13 12 11 10 9 8
    16 15 14 13 12 11 10 9 87654 21
    765433
    21
    PLAY INREC OUTSPOT OUT D ATACAMERA
    SW INMULTI
    SCREEN OUT
    SD RD
    IN IN
    CAMERA RS485
    A B A B GVS/VD SPOT DATAALARM / REMOTE
    MODESIGNAL GND
    43 21
    OUT OUT
    IN
    OUT43 21TR
    IN IN
    CAMERA RS485
    A B A B GVS/VD SPOT DATAALARM / REMOTE
    MODESIGNAL GND
    43 21
    OUT OUT
    IN
    OUT43 21
    Camera No. 1
    Camera No. 2
    Camera No. 3 Camera No. 4 Camera No. 5
    Camera No. 6
    Camera No. 7
    Camera No. 8
    VS/VD INPUT
    Unit Address 1 Unit Address 2
    WJ-MP204C
    WJ-MP204C
    WJ-FS316
    WJ-HD100Unit Address 3
    Unit Address 4
    Video Signal 6-conductor Modular Cable (supplied)
    Termination ON MODE
    VS/VD OUTPUT 
    4-Line
    Monitor No. 1
    Monitor No. 2
    Panasonic Security 
    Data modeTermination OFF
    Panasonic Security 
    Data mode4-Line MODE
    VD OUT
    RS-485 Signal
    (Panasonic Security
    Data Mode)
    SIGNAL GND
    ALARM SERIES
    RECORD TIME
    ADJUSTREMOTEMODE DATA RS-232C VIDEO OUTIN
    OUTIN
    AUDIOMONITOR OUT
    (PLAY) CAMERA
    SW  OUTG
    G
    GPOWER
    ON
    OFFJOG-CLICK
    JOG-LEFT
    JOG-RIGHTALARM SEARCHSTEP
    REW/FF
    STOP/SETUP
    PLAY
    REC
    OUT
    PLAY OUT
    REC OUTAUTO OFF OUTDISK END OUT IN
    OUT
    IN
    RECALL (EXT REC)
    OUTRECOVER OUTRESET IN
    IN
    PLAY IN PLAY
    VIDEO IN REC OUT
    RS-485 Cable
    Branch
    Cable
    Up to four WV-CU360C
    can be used in a system.
    DC 9V IND ATA MODE CONTROLLER No.0987654321
    0987654321
    Keep in OFF position
    Keep in OFF position Termination ON
    Set to OFF position
    (for operator mode) Controller No. 1
    Refer to DIP switch setting on page 15 CONTROLLER No. 
    						
    							14
    DATA Port Connection (PS•Data)
    Data ports are connected with RS-485 cables among devices using the PS•Data protocol as follows.
    Notes:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485
    communication.
    •Internal Diagram
    •Basic Connection Example 2 shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers.
    System ControllerWV-CU360System ControllerWV-CU360UP
    LR
    DOWNSystem ControllerWV-CU360
    Data Multiplex Unit WJ-MP204CData Multiplex Unit WJ-MP204Data Multiplex Unit WJ-MP204
    WJ-MP204C
    WV-CU360C
    4 cameras can be connected to one Data Multiplex Unit
    UP
    LR
    DOWN UP
    LR
    DOWN
    Up to 4 Data Multiplex Units
    Up to 4 System Controllers
    Channel 1 Channel 2 Channel 4 Channel 13 Channel 14 Channel 16
    Unit
    address 1
    Controller
    No. 1Controller No. 2 Controller No. 4 Unit
    address 2Unit
    address 4
    See page 16 for MODE switch and 
    CONTROLLER NO. switch settings.
    D ATA
    Data Multiplex Unit
    WJ-MP204CSystem Controller
    WV-CU360C
    D ATA
    RS-485 Cable
    Termination:
    ONTermination:
    ON
    Data Flow
    –
    WJ-MP204C ← WV-CU360C
    WJ-MP204C ← WV-CU360C
    WJ-MP204C → WV-CU360C
    WJ-MP204C → WV-CU360C
    –
    1
    61
    6
    No.No.
    11
    22
    33
    44
    55
    66
    Name
    GND
    TX(B)
    TX(A)
    RX(B)
    RX(A)
    GND
    Controller endTX (B) 
    TX (A)
    RX (A)
    RX (B) 
    						
    							15
    SW position •Daisy Chain Connection
    DIP Switch Setting (PS•Data)
    An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an
    asterisk *.
    D ATA
    Data Multiplex Unit
    WJ-MP204C
    Branch
    Cable Termination:
    OFF Termination:
    ONSystem Controller
    WV-CU360C
    D ATA  D ATA
    Video Multiplexer
    WJ-FS309 (WJ-FS316)
    RS-485
    CableTermination:
    ON
    RS-485
    Cable
    MODE
    123456 78
    OFF
    ON
    OFF
    Not used Function
    ON
    Bit 6 Bit 7
    Bit 8
    Bit 5
    Bit 4
    Bit 3
    Bit 2
    Bit 1Operation mode Baud rate selection
    Data transmission mode
    Line termination
    Reserved
    System Unit Version
    System Unit Version
    System Unit VersionOperator* Fixed to OFF*
    Fixed to OFF*
    Off
    Fixed to OFF*
    Fixed to OFF*
    Fixed to OFF*
    Fixed to OFF*Administrator
    Not used
    Not used On*
    Not used
    Not used Not used
    1. Remove the DC plug from the rear of the controller.
    2. Set the switch referring to the table.
    3. Connect the DC plug to the controller.
    Notes:
    • Bits 1 - 4 are reserved.
    • Bit 5 opens or terminates the communication chain. The switch should be set to OFF when the controller is located in an
    intermediate position.
    • Bit 6 specifies the operation mode, Operator or Administrator. The switch should be set to Administrator when setting up
    the controller. Remember to set this switch to the right position after completion of the setup operation.
    • Bits 7 and 8 are used in the OFF position. 
    						
    							16
    MODE Switch Setting for System Example 2
    The MODE switch needs to be set prior to operating a sys-
    tem connected as shown in Example 2.
    Bit 3 should be set to OFF.
    Bit 5 should be set to OFF when the controller is placed
    in an intermediate position, or set to ON when it is con-
    nected at the chain end.
    Controller Number Setting (PS•Data)
    A 10-position rotary switches provided on the rear for spec-
    ifying the unit number of the WV-CU360C controller in a
    PS
    •Data system.
    1. Remove the DC plug from the rear of the controller.
    2. Use a screw driver to rotate the switch so that the arrow
    comes to the number you wish.
    3. Connect the DC plug to the controller.
    Notes:
    • Set the switch to #1 when a single controller is used in
    the system.
    • Specify a unique number for each controller when con-
    necting multiple controllers in the system.  One con-
    troller within the multiple controller system must be
    assigned the number 1.
    • Positions #0 and #9 are reserved and cannot be used.
    0987654321
    CONTROLLER No.
    Controller No. Switch of WV-CU360C Controller No.
    0 Reserved
    11
    22
    33
    44
    55
    66
    77
    88
    9 Reserved
    123456 78
    OFF
    ON 
    						
    							17
    CONTROLLER SETUP PROCEDURES (PS•Data)
    To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the
    controller as described below.
    Prior to Setup
    Do the following before entering the setup mode.
    1. Confirm that all necessary connections and switch set-
    tings are complete.
    2. With the power turned off, move bit #6 of the MODE
    switch on the rear to ON (administrator) position.
    3. Supply power to the controller.
    4. Turn on the power of cameras and other system units.
    5. The LCD displays [SEtUP]. The controller is ready to
    enter the setup mode.
    When setup is completed, restore the switch to its original
    position.
    1. With the power turned off, move bit #6 of the MODE
    switch on the rear to OFF (operator) position.
    2. Supply power to the controller.
    Buttons and Controls used for Setup
    The following buttons and joystick operations are used in
    the setup operation.  There are three ways to select a para-
    meter, but the following pages only describe the selection
    by use of the joystick.  Instead of operating the joystick, you
    can enter the number enclosed in brackets with the numer-
    ic keys or press the plus and minus buttons.
    0
    9
    Numeric buttons: To select a parameter
    To enter a password or
    parameter
    CAM/SET button: To confirm the selected
    menu, selected parame-
    ter or entered password
    To enter a submenu
    MON/ESC button: To return to the previous
    menu
    CAM
    SET
    MON
    ESC
    DOWN LRUP
    LR
    UP
    DOWNR
    UP
    DOWN LR
    Up: To select a setup menu
    Down: To select a setup menu
    Left: To decrease the parameter
    Right: To increase the parameter 
    EL-ZOOM
    STILL
    –
    +
    or
    or 
    						
    							18
    Setup Menus
    There are 12 setup menus as shown below.
    Menu 
    Selection
    Move Joystick up
    and down to selectSetup Menus
    Parameter Selection (default*)
    LED Display
    blinking
    Setup
    Administrator
    Password
    Prompt
    Speed
    Parity
    Wait
    Controller
    Unit
    Group
    System
    Unit
    Group
    Unit A
    Number
    Unit B
    Number
    User
    Password
    Super
    User
    Password
    User
    Certification
    Cleaning
    Unit
    TestInitial
    Display
    Authorization
    Baud Rate
    (bps)Press
    twice
    Parity Check
    Wait Time
    (ms)
    Unit
    Assignment to
    Button A
    Unit
    Assignment to
    Button B
    Administrator
    Password
    User
    Authorization
    Camera
    Cleaning
    Unit Connection
    Test
    CAM
    SET
    CAM
    SET
    MON
    ESC
    CAM
    SET
    LED prompts you to enter a pass-
    word
    Enter a 5-digit 
    password, press
    (12345*)
    (1) 2 400  (2) 4 800  (3) 9 600*
    (4) 19 200
    (1) None*   (2) Even
    (1) Off*  (2) 100  (3) 200  (4) 400
    (5) 1 000
    Leave as it is
    Leave as it is
    Enter a 5-digit 
    number, press
    (12345*) Reading Function
    OK No
    DOWN LR
    UP
    LR
    CAM
    SET
    CAM
    SET
    Enter a 5-digit 
    number, press
    (12345*)
    (1) Off   (2) On*CAM
    SET 
    						
    							19
    Administrator Authorization
    1. Press the CAM/SET button while [SEtUP] is displayed.
    The [- - - - -] prompt appears.
    2. Enter a password with the numeric buttons, then press
    the CAM/SET button.
    The default setting is [12345].
    3. [SPEED] appears when the right password is entered. If
    password entry failed, the menu returns to [- - - - -].
    Notes: 
    • We recommend that you register a new password dif-
    ferent from “12345” in [SUSrP], and note down the reg-
    istered password for future reference.
    • Powering up the controller while holding down numeric
    buttons 2, 4 and 5 simultaneously will reset the pass-
    word to “12345”. Remember that this procedure also
    resets all other menu parameters to the default settings.
    Baud Rate
    In this menu, the communication speed (bps: bits per sec-
    ond) is selected.  The communication speed should match
    that of the other units connected in the communication
    chain.
    1. Display [SPEED] and press the CAM/SET button twice.
    2. Select a parameter entering a bracket-enclosed num-
    ber, e.g., (3), moving the joystick right and left, or
    pressing the [+] and [–] button.
    The default setting is 19 200 bps.
    (1) 2 400:2 400 bps
    (2) 4 800:4 800 bps
    (3) 9 600:9 600 bps
    (4) 19 200:19 200 bps
    Note:Selecting a slower rate (e.g., 2 400 bps) will
    delay the response time (e.g., the time until an acti-
    vated alarm is reset).
    3. Press the CAM/SET button to validate the selection.
    4. Press the ESC button to go back to the previous menu.
    Parity
    In this menu, the parity check mode is selected.
    1. Display [PrtY] and press the CAM/SET button twice.
    2. Select a parameter with the joystick.
    The default setting is None.
    n:None
    E:Even parity
    3. Press the CAM/SET button to validate the selection.
    4. Press the ESC button to go back to the previous menu.
    Wait Time
    In this menu a wait time is selected. The controller will
    retransmit data when there is no response during the speci-
    fied wait time.
    1. Display [LJAit] and press the CAM/SET button twice.
    2. Select a parameter with the joystick.
    The default setting is Off.
    (1) OFF:Off, no retransmission of data
    (2) 100:100 ms
    (3) 200:200 ms
    (4) 400:400 ms
    (5) 500:500 ms
    (6) 1 000:1 s
    3. Press the CAM/SET button to validate the selection.
    4. Press the ESC button to go back to the previous menu.
    The following two menus should be maintained in the
    default condition.
    Controller Unit-Group Address
    [CU-gr] appears on the Setup menu, but leave the
    default as it is.
    System Unit-Group Address
    [SU-gr] appears on the Setup menu, but leave the
    default as it is. 
    						
    							20
    Unit A button Assignment
    In this menu, a maximum of 9 system units is assigned to
    numeric buttons 1-9 regardless of unit address. 
    This is to avoid double-digit unit addresses which can
    occur in a large system with many units connected and
    could confuse operators.
    A frequently used system unit can be easily selected in nor-
    mal operation by pressing one numeric button and then the
    UNIT A button.
    1. Display [UA-no] and press the CAM/SET button. The
    LED displays [A1-01] while “1” following A blinks.
    The first 2 digits from A1 to A9, “A numbers”, stand for
    numeric buttons from 1 to 9 to be pressed prior to UNIT
    A button in normal operation. The next 2 digits are the
    unit address assigned in the following procedures.
    The default setting is shown below.
    A1-01
    A2-02
    A3-03
    A1-04
    A5-05
    A6-06
    A7-07
    A8-08
    A9-09
    2. Select an “A number” entering a number from 1 to 9,
    then press the CAM/SET button. The LED displays “A
    number” A3 when numeric button 3 is entered for
    example.
    Available A numbers:1-9
    3. Press the CAM/SET button to validate the selection. The
    LED displays [A3-03] while the next two digits are blink-
    ing.
    4. Enter a 2-digit unit address that you wish to assign to
    the “A number” (e.g., A3), then press the CAM/SET but-
    ton. The LED displays [A3-99], for example, when you
    enter unit address 99.
    Available addresses:01-99
    5. Press the CAM/SET button to validate the selection.
    Repeat above the steps 2 to 5 as needed.
    6. Press the ESC button to go back to the previous menu.
    Unit B button Assignment
    The UNIT B button is set up in the same way as the UNIT A
    button for use in normal operation.  Refer to the above
    description for Unit A button Assignment.
    User Password
    In this menu, a 5-digit password for user authorization is
    registered.
    1. Display [UsrP ] and press the CAM/SET button. The
    LED displays the registered password.
    2. Enter a 5-digit password with the numeric buttons. 
    The default setting is [12345].
    Available password digits: 00000-99999
    3. Press the CAM/SET button to validate the selection.
    4. Press the ESC button to go back to the previous menu.
    Administrator Password
    In this menu, a 5-digit password for administrator certifica-
    tion is registered.
    1. Display [SUsrP] and press the CAM/SET button. The
    LED displays the registered password.
    2. Enter a 5-digit password with the numeric buttons. 
    The default setting is [12345].
    Available password digits:00000-99999
    3. Press the CAM/SET button to validate the selection.
    4. Press the ESC button to go back to the previous menu.
    User Password Certification
    In this menu, password certification in normal operation is
    enabled or disabled.
    1. Display [USr-C] and press the CAM/SET button. The
    LED displays [UC-on] or [UC-oF].
    2. Select On or Off with the joystick controller. 
    The default setting is On.
    on:Password certification enabled.
    oF:Password certification disabled.
    3. Press the CAM/SET button to confirm the selection.
    4. Press the ESC button to go back to the previous menu. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic System Controller Wv Cu360c Operating Instructions