73 SETUP PROCEDURES (For System 850) To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the controller as described below. Prior to Setup Do the following before entering the setup mode. 1. Confirm that all necessary connections and switch set- tings are complete. 2. With the power turned off, move bit #6 of the MODE switch on the rear to ON (administrator) position. 3. Supply power to the controller. 4. Turn on the power of cameras and other system units. 5. The LCD displays [SEtUP]. The controller is ready to enter the setup mode. When setup is completed, restore the switch to its original position. 1. With the power turned off, move bit #6 of the MODE switch on the rear to OFF (operator) position. 2. Supply the power to the controller. Buttons and Controls used for Setup The following buttons and joystick operations are used for setup. DC 9V IN MODE 1 234 5678 OFF ON MODE 12345678 OFF ON Operator mode Administrator mode 0 9Numeric buttons: To select a parameter CAM (ENTER) button: To execute modes and parameters To enter a submenu CLEAR (ESC) button: To return to the previ- ous menu CAMERA (ENTER) AUTO PA N DOWN LRUP LR UP DOWNR UP DOWN LR Up: To select a setup menu Down: To select a setup menu Left: To decrease the parameter Right: To increase the parameter CLEAR (ESC) EXIT
74 Setup Procedures Set up the baud rate and parity check mode for the controller while observing the LED on the front panel. Menu Selection Move Joystick UP and down to selectSetup Menus Parameter Selection (default*) LED Display blinking Setup Administrator Password Prompt Speed ParityInitial Display Authorization Baud Rate (bps)Press twice Parity Check CAM SET CAM SET MON ESC LED prompts you to enter pass- word Enter a 5-digit password, press (12345*) (1) 2 400 (2) 4 800 (3) 9 600* (4) 19 200 (1) None* (2) Even Reading Function OK No DOWN LRUP LR CAM SET Administrator Authorization 1. Press the CAMERA (ENTER)button while [SEtUP] is displayed. The [- - - - -] prompt appears. 2. Enter a password using the numeric buttons, then press the CAMERA (ENTER)button. The default setting is [12345]. 3. If the password entered is valid, [SPEED] appears. If password entry failed, the menu returns to [SEtUP]. Baud Rate In this menu, the communication speed (bps: bits per sec- ond) is selected. The communication speed should match that of the WJ-SX850. 1. Display [SPEED], and press the CAMERA (ENTER) button twice. 2. Select a parameter entering a bracket-enclosed num- ber, e.g., (3), moving the joystick. The default setting is 9 600 bps. (1) 2 400:2 400 bps (2) 4 800:4 800 bps (3) 9 600:9 600 bps (4) 19 200:19 200 bpsNote:Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an acti- vated alarm is reset). 3. Press the CAMERA (ENTER)button to validate the selection. 4. Press the CLEAR(ESC)button to return to the [SPEED] menu. Parity In this menu, the parity check mode is selected. 1. Display [PrtY] and press the CAMERA (ENTER)button twice. 2. Select a parameter with the joystick. The default setting is None. n:None E:Even parity 3. Press the CAMERA (ENTER)button to validate the selection. 4. Press the CLEAR(ESC)button to return to the [SPEED] menu. Note:The baud rate and parity check mode of the WJ- SX850 and the controller must be the same, otherwise data communications will not function.
75 OPERATING PROCEDURES (For System 850) Login & Logout Login 1. Turn on the power switches of all system components. 2. Turn on the power of the WV-CU360C System Controller by connecting the AC adapter to the AC outlet. The OPERATE indicator lights up and “NO USER” will appear on the LED display of the System Controller. 3. Enter your registered Operator ID number (up to 5 dig- its) using the numeric buttons, then press the [CAM- ERA (ENTER)]button. The underline appears on the LED display. 4. Enter your registered Password (up to 5 digits) using the numeric buttons, then press the [CAMERA (ENTER)]button. If the operator ID and password entered are valid, the LED will display “READY”.Note:If login has failed (operator or password error), the PROHIBITED indicator on the controller will light up and “NO ACCESS” will blink on the LED display for about 3 seconds. Then the login procedure returns to the start. Logout 1. While holding down the LOG OUTbutton, press the [CAMERA (ENTER)]button . “NO USER” is displayed on the LED display. PROGRAM PRESET CALL PRESET AUX1 OFF CAM ID AUX1 ON GEN WIPER AUX2 OFF MON STATUS AUX2 ON ALL SHIFTCLEAR ( ESC)DEF OFFDEF ONCAMERA ( ENTER) AUTO PA N 123 456 78 09 PROGRAM PRESET CALL PRESET AUX1 OFF CAM ID AUX1 ON GEN WIPER AUX2 OFF MON STATUS AUX2 ON ALL SHIFTCLEAR ( ESC)DEF OFFDEF ONCAMERA ( ENTER) AUTO PA N 123 456 78 09 LOG OUTCAMERA (ENTER) AUTO PA N Note: This section describes only some important operations such as login, logout, and different operations from the front panel of the System 850. Please refer to the manual included with the System 850 for further information on camera selection, monitor selection and so forth.
78 Power Source: 9 V DC, 400 mA (Use the supplied AC Adapter only) Data Output/Input Port: 6-conductor modular jack (RS-485, Full Duplex) x2 Switching Functions : Camera selection, Monitor Selection/Sequence Switching of Live and Playback/Changing the Multiscreen Picture Layout/ Still/Electronic Zoom/Sequence (available for WJ-FS309/316/409/416/616/ 616C) Controller Number 1-8 (Rotary Switch) Unit Address Selection: 1-99 (for PS •Data), 1-16 (WJ-FS616/616C) Monitor Number Selection: 1-99 (for PS •Data) Camera Number Selection: 1-199 (for PS •Data) Lens Functions: Iris: Open/Close/Preset (only with DC control lens) Focus: Near/Far/Auto Focus Zoom: Wide/Tele Housing: Defroster: On/Off Wiper: On/Off Auxiliary 1: On/Off Auxiliary 2: On/Off Pan/Tilt: Manual Pan: Right/Left Manual Tilt: Up/Down Auto Pan, Auto Sort, Auto Sequence, Random Pan, Preset Position, Home Position, Camera Patrol Other Camera Controls: Camera Setup Camera Function System Operation: Alarm (Display/Suspend/Recall/Reset) Setup Ambient Operating Temperature: –10˚C - +50˚C (14˚F - 122˚F) Ambient Operating Humidity: Less than 90 % Dimensions: 300 (W) mm x 74 (H) mm x 177 (D) mm [11-13/16” (W) x 2-15/16” (H) x 6 15/16” (D)] Weight: 1.3 kg(2.9 lbs.) Input Power Source: 120 V AC, 60 Hz Power Consumption: 10 W Output Power Source: 9 V DC Power Consumption: 400 mA Dimensions and weight are approximate. Specifications are subject to change without notice. SPECIFICATIONS STANDARD ACCESSORIES AC Adapter ......................................................................1 pc 6-conductor Modular Cable Assembly ............................1 pcPanel Template for WJ-FS616/616C ................................1 pc Panel Template for WJ-SX350 .........................................1 pc Panel Template for System 850 .......................................1 pc
79 The System Controller WV-CU360C can be reset to the default settings. 1. Remove the DC plug of the AC adapter from the con- troller. 2. While pressing numeric buttons 2, 4and 6simultane- ously, plug in the DC plug. 3. When all indicators light up, resetting is completed. Note:Keep the DC plug connected to the controller until the reset procedure is completed. 123 46 789 0 5 PROGRAM PRESET ESC HOME SET PRESET ALL RESET
N1001-0 V8QA5880BN Printed in Japan N19 Imprimé au Japon 2001 © Matsushita Communication Industrial Co., Ltd. All rights reserved.Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905)624-5010 Panasonic Sales Company Division of Matsushita Electric of Puerto Rico Inc. Ave. 65 de Infanteria. Km. 9.5 San Gabriel Industrial Park, Carolina, Puerto Rico 00985 (809)750-4300 Panasonic Security and Digital Imaging Company A Division of Matsushita Electric Corporation of America Executive Office:One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838 Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840