    Have a look at the manual Panasonic System Controller Wv Cu360c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							73
    SETUP PROCEDURES (For System 850)
    To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the
    controller as described below.
    Prior to Setup
    Do the following before entering the setup mode.
    1. Confirm that all necessary connections and switch set-
    tings are complete.
    2. With the power turned off, move bit #6 of the MODE
    switch on the rear to ON (administrator) position.
    3. Supply power to the controller.
    4. Turn on the power of cameras and other system units.
    5. The LCD displays [SEtUP]. The controller is ready to
    enter the setup mode.
    When setup is completed, restore the switch to its original
    position.
    1. With the power turned off, move bit #6 of the MODE
    switch on the rear to OFF (operator) position.
    2. Supply the power to the controller.
    Buttons and Controls used for Setup
    The following buttons and joystick operations are used for
    setup.
    DC 9V IN
    MODE
    1 234 5678
    OFF
    ON
    MODE
    12345678
    OFF
    ON
    Operator mode
    Administrator mode
    0
    9Numeric buttons: To select a parameter
    CAM (ENTER) button: To execute modes
    and parameters
    To enter a submenu
    CLEAR (ESC) button: To return to the previ-
    ous menu
    CAMERA
    (ENTER)
    AUTO
    PA N
    DOWN LRUP
    LR
    UP
    DOWNR
    UP
    DOWN LR
    Up: To select a setup menu
    Down: To select a setup menu
    Left: To decrease the parameter
    Right: To increase the parameter 
    CLEAR
    (ESC)
    EXIT 
    						
    							74
    Setup Procedures
    Set up the baud rate and parity check mode for the controller while observing the LED on the front panel.
    Menu 
    Selection
    Move Joystick 
    UP and down 
    to selectSetup Menus
    Parameter Selection (default*)
    LED Display
    blinking
    Setup
    Administrator
    Password
    Prompt
    Speed
    ParityInitial
    Display
    Authorization
    Baud Rate
    (bps)Press
    twice
    Parity Check
    CAM
    SET
    CAM
    SET
    MON
    ESC
    LED prompts you to enter pass-
    word
    Enter a 5-digit password, 
    press                 (12345*)
    (1) 2 400  (2) 4 800  (3) 9 600*
    (4) 19 200
    (1) None*   (2) Even Reading Function
    OK No
    DOWN LRUP
    LR
    CAM
    SET
    Administrator Authorization
    1. Press the CAMERA (ENTER)button while [SEtUP] is
    displayed.  The [- - - - -] prompt appears.
    2. Enter a password using the numeric buttons, then press
    the CAMERA (ENTER)button.
    The default setting is [12345].
    3. If the password entered is valid, [SPEED] appears.  If
    password entry failed, the menu returns to [SEtUP].
    Baud Rate
    In this menu, the communication speed (bps: bits per sec-
    ond) is selected.  The communication speed should match
    that of the WJ-SX850.
    1. Display [SPEED], and press the CAMERA (ENTER)
    button twice.
    2. Select a parameter entering a bracket-enclosed num-
    ber, e.g., (3), moving the joystick.
    The default setting is 9 600 bps.
    (1) 2 400:2 400 bps
    (2) 4 800:4 800 bps
    (3) 9 600:9 600 bps
    (4) 19 200:19 200 bpsNote:Selecting a slower rate (e.g., 2 400 bps) will
    delay the response time (e.g., the time until an acti-
    vated alarm is reset).
    3. Press the CAMERA (ENTER)button to validate the
    selection.
    4. Press the CLEAR(ESC)button to return to the [SPEED]
    menu.
    Parity
    In this menu, the parity check mode is selected.
    1. Display [PrtY] and press the CAMERA (ENTER)button
    twice.
    2. Select a parameter with the joystick.
    The default setting is None.
    n:None
    E:Even parity
    3. Press the CAMERA (ENTER)button to validate the
    selection.
    4. Press the CLEAR(ESC)button to return to the [SPEED]
    menu.
    Note:The baud rate and parity check mode of the WJ-
    SX850 and the controller must be the same, otherwise
    data communications will not function. 
    						
    							75
    OPERATING PROCEDURES (For System 850)
    Login & Logout
    Login
    1. Turn on the power switches of all system components.
    2. Turn on the power of the WV-CU360C System Controller
    by connecting the AC adapter to the AC outlet.
    The OPERATE indicator lights up and “NO USER” will
    appear on the LED display of the System Controller.
    3. Enter your registered Operator ID number (up to 5 dig-
    its) using the numeric buttons, then press the [CAM-
    ERA (ENTER)]button.  The underline appears on the
    LED display.
    4. Enter your registered Password (up to 5 digits) using
    the numeric buttons, then press the [CAMERA
    (ENTER)]button.
    If the operator ID and password entered are valid, the
    LED will display “READY”.Note:If login has failed (operator or password error), the
    PROHIBITED indicator on the controller will light up and
    “NO ACCESS” will blink on the LED display for about 3
    seconds. Then the login procedure returns to the start.
    Logout
    1. While holding down the LOG OUTbutton, press the
    [CAMERA (ENTER)]button . 
    “NO USER” is displayed on the LED display.
    PROGRAM
    PRESET
    CALL
    PRESET
    AUX1 OFF
    CAM ID
    AUX1 ON
    GEN
    WIPER
    AUX2 OFF
    MON STATUS
    AUX2 ON
    ALL
    SHIFTCLEAR
    (
    ESC)DEF OFFDEF ONCAMERA
    (
    ENTER)
    AUTO
    PA N
    123
    456
    78
    09
    PROGRAM
    PRESET
    CALL
    PRESET
    AUX1 OFF
    CAM ID
    AUX1 ON
    GEN
    WIPER
    AUX2 OFF
    MON STATUS
    AUX2 ON
    ALL
    SHIFTCLEAR
    (
    ESC)DEF OFFDEF ONCAMERA
    (
    ENTER)
    AUTO
    PA N
    123
    456
    78
    09
    LOG OUTCAMERA
    (ENTER)
    AUTO
    PA N
    Note: This section describes only some important operations such as login, logout, and different operations from the front
    panel of the System 850. Please refer to the manual included with the System 850 for further information on camera
    selection, monitor selection and so forth. 
    						
    							78
    
    Power Source: 9 V DC, 400 mA (Use the supplied AC Adapter only)
    Data Output/Input Port: 6-conductor modular jack (RS-485, Full Duplex) x2
    Switching Functions : Camera selection, Monitor Selection/Sequence
    Switching of Live and Playback/Changing the Multiscreen Picture Layout/
    Still/Electronic Zoom/Sequence (available for WJ-FS309/316/409/416/616/
    616C)
    Controller Number 1-8 (Rotary Switch)
    Unit Address Selection: 1-99 (for PS
    •Data), 1-16 (WJ-FS616/616C)
    Monitor Number Selection: 1-99 (for PS
    •Data)
    Camera Number Selection: 1-199 (for PS
    •Data)
    Lens Functions: Iris: Open/Close/Preset (only with DC control lens)
    Focus: Near/Far/Auto Focus
    Zoom: Wide/Tele
    Housing: Defroster: On/Off 
    Wiper: On/Off
    Auxiliary 1: On/Off
    Auxiliary 2: On/Off
    Pan/Tilt: Manual Pan: Right/Left
    Manual Tilt: Up/Down
    Auto Pan, Auto Sort, Auto Sequence, Random Pan, Preset Position, Home
    Position, Camera Patrol
    Other Camera Controls: Camera Setup
    Camera Function
    System Operation: Alarm (Display/Suspend/Recall/Reset)
    Setup
    Ambient Operating Temperature: –10˚C - +50˚C (14˚F - 122˚F)
    Ambient Operating Humidity:  Less than 90 %
    Dimensions: 300 (W) mm x 74 (H) mm x 177 (D) mm
    [11-13/16” (W) x 2-15/16” (H) x 6 15/16” (D)]
    Weight: 1.3 kg(2.9 lbs.)
    
    Input
    Power Source: 120 V AC, 60 Hz
    Power Consumption: 10 W
    Output
    Power Source: 9 V DC
    Power Consumption: 400 mA
    Dimensions and weight are approximate.
    Specifications are subject to change without notice.
    SPECIFICATIONS
    STANDARD ACCESSORIES
    AC Adapter ......................................................................1 pc
    6-conductor Modular Cable Assembly ............................1 pcPanel Template for WJ-FS616/616C ................................1 pc
    Panel Template for WJ-SX350 .........................................1 pc
    Panel Template for System 850 .......................................1 pc 
    						
    							79
    The System Controller WV-CU360C can be reset to the
    default settings.
    1. Remove the DC plug of the AC adapter from the con-
    troller.
    2. While pressing numeric buttons 2, 4and 6simultane-
    ously, plug in the DC plug.
    3. When all indicators light up, resetting is completed.
    Note:Keep the DC plug connected to the controller
    until the reset procedure is completed. 
    123
    46
    789
    0
    5
    PROGRAM
    PRESET ESC HOME
    SET PRESET
    ALL RESET 
    						
    							N1001-0 V8QA5880BN Printed in Japan
    N19 Imprimé au Japon 2001 © Matsushita Communication Industrial Co., Ltd.  All rights reserved.Panasonic Canada Inc.
    5770 Ambler Drive, Mississauga,
    Ontario, L4W 2T3 Canada (905)624-5010
    Panasonic Sales Company
    Division of Matsushita Electric of Puerto Rico Inc.
    Ave. 65 de Infanteria. Km. 9.5
    San Gabriel Industrial Park, Carolina,
    Puerto Rico 00985 (809)750-4300
    Panasonic Security and Digital Imaging Company
    A Division of Matsushita Electric Corporation of America
    Executive Office:One Panasonic Way 3E-7, Secaucus, New Jersey 07094
    Regional Offices:
    Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303
    Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838
    Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211
    Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic System Controller Wv Cu360c Operating Instructions