Home > Panasonic > Controller > Panasonic System Controller Wv Cu360c Operating Instructions

Panasonic System Controller Wv Cu360c Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic System Controller Wv Cu360c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							53
    For WJ-SX350 Matrix
    Switcher System 
    						
    							54
    MAJOR OPERATING CONTROLS & THEIR FUNCTIONS
    Front View (Template for WJ-SX350)
    SEQ
    HISTORY
    AUTO FOCUS
    OPERATELOGIN ALARMBUSYPROHIBITED
    AUXIRIS
    CLOSE OPEN
    NEAR FAR
    TELE WIDE
    FOCUS
    ZOOM IRIS RESET
    BACK
    -1 CAM 
    DEC+1 CAM 
    INC
    FWD
    BACK
    ALT PAUSE FUNCTION
    ACK/RESET FWD
    ALL RESET
    RECALL
    STATUSPRESET
    POSIPA N
    MONCAM
    ESC SET
    CAM
    POSI
    UP
    LR
    DOWN
    MONITORCAMERA
    For Matrix Switcher
    WV-CU C360
    CAMERA SITE CONTROL
    System Controller
    SET UPCAMMENU
    !7
    !8
    !9
    @0
    @1
    @2
    @3
    @4
    @5
    @6
    @7
    @8
    @9
    #0
    #1
    qwerty
    u
    i!0o!1!2!3!4!5!6
    qOperate indicator (OPERATE)
    Is lit while power is supplied to the System Controller.
    wLog-in indicator (LOGIN)
    Lights up when login has been successfully finished.
    eAlarm indicator (ALARM)
    Blinks when an alarm condition exists.
    It changes to steady light when the alarm is reset auto-
    matically.
    To turn off the indicator, press the ACK/RESET or ALL
    RESET button.
    rLED Display (MONITOR CAMERA)
    Displays the number of monitors and cameras currently
    controlled.tBusy indicator (BUSY)
    Blinks or lights up when you attempt to control a certain
    monitor (or a camera) that is already used by a higher
    priority operator, or when the higher priority operator
    chooses the camera or monitor you are currently oper-
    ating.
    Blinking: Monitor Busy
    Steady light: Camera Busy
    yProhibited indicator (PROHIBITED)
    Lights up for two seconds when an invalid operator
    number or password is used to log in.  The indicator
    also blinks when an attempt is made to access a func-
    tion that is prohibited for the given operator level. 
    						
    							55
    uJoystick Controller (UP/DOWN/L/R)
    Used to operate the Pan/Tilt Head manually, or to move
    the cursor to the desired position on the SETUP MENU
    of the Matrix Switcher.
    UP: Upward
    DOWN: Downward
    L: Left
    R: Right
    iIris buttons (IRIS CLOSE/OPEN)
    Close or open the lens iris of cameras equipped with
    the specified lens.
    When these buttons are pressed at the same time, the
    lens iris is reset to the factory setting.
    oFocus buttons (FOCUS NEAR/FAR)
    Adjust the lens focus of cameras equipped with the
    specified lens.
    When these buttons are pressed at the same time, the
    lens focus is set automatically when the specified cam-
    era, such as the WV-CS854, is used.
    !0Zoom buttons (ZOOM TELE/WIDE)
    Zoom the image in or out if the camera is equipped with
    the specified lens.
    !1Auxiliary button (AUX)
    In combination with the number buttons 1 to 4, controls
    the Auxiliary switches for the Receiver, Wiper and
    Defroster.
    Press the numeric button, then press this button to turn
    the Auxiliary switches for the Wiper or Defroster On or
    Off.
    1:Auxiliary Switch 1
    2:Auxiliary Switch 2
    3:Wiper
    4:Defroster
    !2Panning button (PAN)
    In combination with the numeric button 1 or 2, is used
    to control the panning mode of the Pan/Tilt Head.
    Press the numeric button, then press this button to turn
    the Panning mode On and Off.
    1:Auto Panning Mode
    2:Random Panning Mode
    !3Preset Position button (PRESET POSI/CAM POSI)
    In combination with the numeric buttons, moves the
    camera to the desired preset position.  Also selects a
    camera position by a serial number assigned indepen-
    dently of the camera number.  Specify a number, then
    press ALT and finally this button.!4Camera/Set button (CAM (SET))
    CAM:Used for camera selection.  To select a camera,
    enter the desired camera number with the numeric
    buttons, and then press this button.
    SET:Executes the currently highlighted setting in the
    setup menu of the Matrix Switcher and opens a
    submenu.
    !5Numeric buttons (0 - 9)
    These buttons are used for numerical input such as
    camera and monitor selection, sequence and preset
    position, etc.
    Buttons 2, 4, 6 and 8 are also used to move the cursor
    to the desired position on the Camera’s Set Up Menu.
    !6Monitor/Escape button (MON (ESC))
    MON:Used for monitor selection.  To select a monitor,
    enter the monitor number with the numeric buttons,
    and then press this button.
    ESC:Escapes from or executes the currently highlight-
    ed selection in the setup menu of the matrix switch-
    er.
    !7Alternate button (ALT)
    Alternates the function of dual-function buttons between
    the normal and the alternate function.  It also enables
    the CAM MENU button and SET UP button to display
    the assigned menu or setup table on the selected moni-
    tor.
    The indicator is lit while the function mode is selected.
    !8Sequence Pause button (PAUSE)
    Pauses a sequence that is being run on the selected
    monitor.
    !9Function button (FUNCTION)
    Pressing this button in combination with another opera-
    tion button activates a specific function.
    @0Alarm Acknowledgment and Reset button
    (ACK/RESET)
    Cancels an activated alarm.  To cancel the alarm, the
    monitor must first be selected.
    Press this button once to acknowledge the activated
    alarm (the indicator blinks rapidly), then press it again
    to reset the alarm. 
    						
    							56
    @1@2Backward/Forward Sequence button
    (SEQ BACK/FWD)
    BACK:In combination with the numeric buttons, runs a
    Tour or Group sequence backward on the selected
    monitor.
    It is also used to continue a sequence backward,
    that was previously paused on that monitor by
    pressing the PAUSE button.
    FWD:In combination with the numeric buttons, runs a
    Tour or Group sequence forward on the selected
    monitor.
    It is also used to continue a sequence forward, that
    was previously paused on that monitor by pressing
    the PAUSE button.
    @3All Alarms Reset button (ALL RESET)
    Cancels all active alarms at a time.
    To reset all alarms, first select the alarmed monitor
    (Monitor 1 for Alarm Mode 1, any of four monitors for
    Alarm Mode 2), and then press this button.
    Note:To cancel all alarms without first selecting the
    monitor, press this button in combination with the
    ALT button.
    @4@5Decrement/Increment button 
    (–1CAM DEC, +1CAM INC)
    –1CAM DEC:Moves a sequence one step backward
    from the step that was previously paused on the
    selected monitor by pressing the PAUSE button.
    Also, when the selected monitor is in the spot
    mode, pressing this button will replace the currently
    selected camera with the next lower number cam-
    era.
    +1CAM INC:Moves a sequence one step forward from
    the step that was previously paused on a monitor
    by pressing the PAUSE button.
    Also, when the selected monitor is in the spot
    mode, pressing this button will replace the currently
    selected camera with the next higher number cam-
    era.
    @6Alarm Recall button (RECALL)
    Recalls the Alarm Log (record of activated alarms).
    Select the desired monitor to display the alarm records,
    then press this button to toggle the display of alarm
    records On and Off on the selected monitor.
    @7@8Backward/Forward History button 
    (HISTORY BACK/FWD)
    BACK:Displays the previous camera picture on the
    selected monitor.  Each operation of this button
    backs up the camera picture by one.
    In the SETUP MENU, selects the previous page or
    step of the setup tables.
    FWD:Moves the camera picture forward on the select-
    ed monitor after the HISTORY BACK button has
    been used.
    In the SETUP MENU, selects the next page or step
    of the setup tables.@9Status button (STATUS)
    Toggles the display of the Camera Site Status Table on
    the selected monitor On and Off.
    Note:To toggle the display of the System Status Table
    on the selected monitor On and Off, press this but-
    ton in combination with the ALT button.
    #0Camera Menu button (CAM MENU)
    In combination with the ALT button, toggles the display
    of the selected Camera’s Setup Menu On and Off.
    The indicator lights up when the camera setup mode is
    selected.
    #1Set Up button (SET UP)
    In combination with the ALT button, toggles the display
    of the SETUP MENU of the Matrix Switcher On and Off.
    The indicator lights up when the setup mode is select-
    ed. 
    						
    							57
    INSTALLATIONS (For WJ-SX350)
    The installation should be made by qualified service personnel or system installers according to the following instructions.
    CAUTION
    System Connections
    Connection Example
    The example below shows a typical system connection.
    LOGIN
    BUSYPROHIBITED STATUS
    ALARM ALARMSEQUENCE
    ACK/RESET
    OPERATE
    ALL RESETRECALL
    CAM
    MENUSET UP
    PAUSEBACK
    SEQFWD
    SEQ
    −1 CAM
    DEC
    DEC+1 CAM
    INC
    321654987
    FWD
    ALTSHIFTAUTO FOCUS
    FUNCTIONONOFF
    PRESET
    POSI
    CAM
    POSIBACKCAM0MONSET ESCHISTORY
    AUTO PANRANDM PAN
    AUX 1WIPER
    AUX 2DEF
    IRISCLOSE
    NEAR FAROPENIRIS RESET
    FOCUS
    TELE WIDELEFTUP
    DOWN ZOOM
    MATRIX  SWITCHER  WJ-SX350
    CAMERA SITE CONTROL
    Video
    Data RS-485 Up to 32 Cameras
    32-Alarm Input
    System Controller
    (Max.4 Units) Video Monitor(Max.8 Outputs)Time Lapse VCR
    (Max.8 Control Outputs)
    Matrix Switcher
    WJ-SX350
    L
    CLOSEOPEN IRIS
    RUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM
    0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL
    L
    CLOSEOPEN IRIS
    RUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM
    0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL
    L
    CLOSEOPEN IRIS
    RUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM
    0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL
    L
    CLOSEOPEN IRIS
    RUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM
    0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL 
    						
    							58
    DATA Port Connection (For WJ-SX350)
    Data ports are connected with RS-485 cables among devices as follows.
    Note:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485
    communication.
    •Internal Diagram
    DIP Switch Setting (For WJ-SX350)
    An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an
    asterisk *.•Basic Connection
    Data Flow
    –
    WJ-SX350 ← WV-CU360C
    WJ-SX350  ← WV-CU360C
    WJ-SX350  → WV-CU360C
    WJ-SX350  → WV-CU360C
    –
    1
    61
    6
    No.No.
    11
    22
    33
    44
    55
    66
    Name
    GND
    TX(B)
    TX(A)
    RX(B)
    RX(A)
    GND
    Controller end
    1234
    DATA IN
    Matrix Switcher
    WJ-SX350
    LCLOSEOPEN IRISRUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL
    LCLOSEOPEN IRISRUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL
    LCLOSEOPEN IRISRUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL
    LCLOSEOPEN IRISRUP
    DOWNNEARFAR FOCUS
    BUSY
    TELEWIDE ZOOM0987654321
    ALARM MONITOR CAMERALOCKPOWERPROHIBITED
    CAMERA SITE CONTROL
    SW position
    OFF
    See the next page
    See the next page
    See the next page
    Not used
    On*
    Administrator
    Set up from CU360
    3 times Function
    ON
    Bit 1
    Bit 2
    Bit 3
    Bit 4
    Bit 5
    Bit 6
    Bit 7
    Bit 8System Unit Version
    System Unit Version
    System Unit Version
    Reserved
    Line termination
    Operation mode
    Baud Rate Selection
    Repeat Transmissions*
    *
    *
    *
    Off
    Operator*
    Auto-selection*
    1 time*
    TX (B) 
    TX (A)
    RX (A)
    RX (B)
    DC 9V IND ATA MODE CONTROLLER No.0987654321 
    						
    							59
    Controller Number Setting
    Set this switch always to 1 when using the System
    Controller with the WJ-SX350.
    Switch Setting Procedures
    Set the MODE DIP switch and CONTROLLER NO. switch as
    follows.
    1. Remove the DC plug from the rear of the controller.
    2. Set the MODE switches.
    Bit 1 through 3 should match the version of the WJ-
    SX350 installed in your system. Open the SETUP MENU
    of the WJ-SX350 and check the version shown in the
    upper right corner of the menu.
    For version 6.00 or later, set the switches as shown
    below.
    • Bit 1 should be set to OFF*.
    • Bit 2 should be set to ON.
    • Bit 3 should be set to ON.
          S E T U P   M E N U            6.xx/1.xx  
        
        P R O G R A M
        O P E R A T O R
        S Y S T E M
        C A M   D A T A  L O A D
        C A M E R A  T I T L E
        C A M – P O S I  M A P
        F U N C T I O N  K E Y 
    MODE
    123456 78
    OFF
    ON
    For version 1.xx, set the switches as shown below.
    • Bit 1 should be set to OFF*.
    • Bit 2 should be set to ON.
    • Bit 3 should be set to OFF*.
    Bits 4 through 8 are not version related.
    • Bit 4 should be set to OFF*.
    • Bit 5 should be set to ON*.
    • Bit 6 should be set to OFF* (Operator) normally, or
    ON (Administrator) when setting up the controller.
    • Bit 7 should be set to OFF*. Baud rate selection is
    automatic. 
    • Bit 8 should be set to OFF* normally.
    3. Connect the DC plug to the controller.
    MODE
    123456 78
    OFF
    ON
    0987654321
    CONTROLLER No. 
    						
    							60
    CONTROLLER SETUP PROCEDURES (For WJ-SX350)
    Prior to Setup
    Do the following before entering the setup mode.
    1. Confirm that all necessary connections and switch set-
    tings are complete.
    2. With the power turned off, move bit #6 of the MODE
    switch on the rear to ON (administrator) position.
    3. Supply power to the controller.
    4. Turn on the power of cameras and other system units.
    5. The LCD displays [SEtUP]. The controller is ready to
    enter the setup mode.
    When setup is completed, restore the switch to its original
    position.
    1. With the power turned off, move bit #6 of the MODE
    switch on the rear to OFF (operator) position.
    2. Supply power to the controller.
    DC 9V IN
    Buttons and Controls used for Setup
    The following buttons and joystick operations are used for
    setup.
    0
    9Numeric buttons: To select a parameter
    CAM/SET button: To execute modes and
    parameters
    To enter a submenu
    MON/ESC button: To return to the previous
    menu
    CAM
    SET
    DOWN LRUP
    LR
    UP
    DOWNR
    UP
    DOWN LR
    Up: To select a setup menu
    Down: To select a setup menu
    Left: To decrease the parameter
    Right: To increase the parameter MODE
    1 234 5678
    OFF
    ON
    MODE
    12345678
    OFF
    ON
    Operator mode
    Administrator mode
    MON
    ESC
    To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the
    controller as described below. 
    						
    							61
    Setup Procedures
    Set up the baud rate and parity check mode for the controller while observing the LED on the front panel.
    Administrator Authorization
    1. Press the CAM/SETbutton while [SEtUP] is displayed.
    The [- - - - -] prompt appears.
    2. Enter a password using the numeric buttons, then press
    the CAM/SETbutton.
    The default setting is [12345].
    3. If the password entered is valid, [SPEED] appears.  If
    password entry failed, the menu returns to [SEtUP].
    Baud Rate
    When bit 7 of the MODE switch is in the ON position, you
    need to select the communication speed manually to match
    that of the WJ-SX350.
    1. Display [SPEED], and press the CAM/SETbutton twice.
    2. Select a parameter entering a bracket-enclosed num-
    ber, e.g., (3), or moving the joystick.
    The default setting is 9 600 bps. 
    (1) 2 400:2 400 bps
    (2) 4 800:4 800 bps
    (3) 9 600:9 600 bps *
    (4) 19 200:19 200 bpsNote:Selecting a slower rate (e.g., 2 400 bps) will
    delay the response time (e.g., the time until an acti-
    vated alarm is reset).
    3. Press the CAM/SETbutton to validate the selection.
    4. Press the MON/ESCbutton to return to the [SPEED]
    menu.
    Parity
    The parity check mode is selected in this menu.
    1. Display [PrtY] and press the CAM/SETbutton twice.
    2. Select a parameter with the joystick.
    The default setting is None.
    n:None
    E:Even parity
    3. Press the CAM/SETbutton to confirm the selection.
    4. Press the MON/ESCbutton to return to the [SPEED]
    menu.
    Note:The baud rate and parity check mode of the WJ-
    SX350 and the controller must be the same, otherwise
    data communications will not function.
    Menu 
    Selection
    Move Joystick 
    UP and down 
    to selectSetup Menus
    Parameter Selection (default*)
    LED Display
    blinking
    Setup
    Administrator
    Password
    Prompt
    Speed
    ParityInitial
    Display
    Authorization
    Baud Rate
    (bps)Press
    twice
    Parity Check
    CAM
    SET
    CAM
    SET
    MON
    ESC
    LED prompts you to enter pass-
    word
    Enter a 5-digit password, 
    press                 (12345*)
    (1) 2 400  (2) 4 800  (3) 9 600*
    (4) 19 200
    (1) None*   (2) Even Reading Function
    OK No
    DOWN LRUP
    LR
    CAM
    SET 
    						
    							62
    OPERATING PROCEDURES (For WJ-SX350)
    This section describes only some important operations
    such as login, logout, and different operations from the front
    panel of the WJ-SX350. 
    Please refer to the manual included with the WJ-SX350 for
    further information on camera selection, monitor selection
    and so forth.
    Login & Logout
    Login
    1. Type your registered operator number (a maximum of
    15 digits) using the numeric buttons, then press the
    CAM/SETbutton. If login has been successful, the
    LOGIN indicator lights up. If it has failed, another
    attempt can be made when the PROHIBITED indicator
    goes off after 2 seconds.
    2. Type your registered password (a maximum of 5 digits)
    using the numeric buttons, then press the CAM/SET
    button. If password entry has been successful, the
    LOGIN indicator changes from blinking to steady light.
    If it has failed, another attempt can be made when the
    PROHIBITED indicator goes off after 2 seconds.
    Logout
    1. Type 00 using the numeric button, then press the
    FUNCTIONbutton. The LOGIN indicator turns off.
    Lens Control (Auto Focus Operation)
    The following function requires the use of a camera with
    auto focus capability, such as the Panasonic WV-CS854.
    1. Select the desired monitor and camera.
    2. Press the FOCUS NEARand FARbuttons simultane-
    ously to automatically adjust the lens focus on the
    selected camera.
    Pan/Tilt Control (Camera Position
    Operation)
    The following function requires the use of a camera with
    preset panning capability, such as the Panasonic WV-
    CS854.
    1. Select the desired monitor.
    2. Select a registered camera position number using the
    numeric buttons.
    3. Press the ALTbutton (indicator light on), then press the
    PRESET POSIbutton to activate the camera to move to
    the preset position.
    LOGIN
    MONCAM
    ESC SET
    123
    456
    78
    09
    LOGIN
    MONCAM
    ESC SET
    123
    456
    78
    09
    FUNCTION
    AUTO FOCUS
    NEAR FAR
    FOCUS
    ALT
    CAMPOSI
    PRESET
    POSI 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic System Controller Wv Cu360c Operating Instructions