Panasonic System Controller Wv Cu360c Operating Instructions
Have a look at the manual Panasonic System Controller Wv Cu360c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
63 Pan/Tilt Control (Auto/Random Panning) 1. Select the desired monitor and camera. 2. Type 1using the numeric button, then press the PAN button to toggle the Auto Panning function on the selected camera On and Off. 3. Type 2using the numeric button, then press the PAN button to toggle the Random Panning function on the selected camera On and Off. Note:Moving the Joystick Control will stop Auto or Random panning. Camera Housing Control Wiper control 1. Select the desired monitor and camera. 2. Type 3using the numeric button, then press the AUX button to toggle the power of the Wiper on the selected camera On and Off. Note:To prevent premature wearing of the wiper blades, be sure to turn off the wiper when it is not needed or before selecting another camera for viewing. MONCAM ESC SET PA N 123 456 78 09 MONCAM ESC SET AUX 123 456 78 09 Defroster Control 1. Select the desired monitor and camera. 2. Type 4using the numeric button, then press the AUX button to toggle the power of the Defroster on the selected camera On and Off. Auxiliary Control The following function is available only when the WV-RC100 or WV-RC150 Receiver is included in the system. 1. Select the desired monitor and camera. 2. Type 1using the numeric button, then press the AUX button to toggle the user Auxiliary Switch 1 of the Receiver On and Off. 3. Type 2using the numeric button, then press the AUX button to toggle the user Auxiliary Switch 2 of the Receiver On and Off. MONCAM ESC SET AUX 123 456 78 09 MONCAM ESC SET AUX 123 456 78 09
64 System Status Display 1. Select a monitor to display the System Status Table. 2. Press the ALTbutton (indicator light on), then press the STATUSbutton to toggle the display of the System Status Table on the selected monitor On and Off. ALTSTATUS
66 MAJOR OPERATING CONTROLS & THEIR FUNCTIONS Front View (Template for System 850 Matrix Switcher) qOperate indicator (OPERATE) Is lit while power is supplied to the System Controller. wLink indicator (LINK) Lights up when communication is established with the Main CPU. eAlarm indicator (ALARM) Lights up when an alarm condition exists. Select the alarm number using the numeric buttons, then press the ALARM button and the RESET button to turn off the indicator. rMonitor indicator (MONITOR) Lights up when the monitor number is displayed on the LED display. tLED Display Displays the number of monitors and cameras currently controlled. It also displays numeric input, error status, etc.yCamera indicator (CAMERA) Lights up when the camera number is displayed on the LED display. uBusy indicator (BUSY) Lights up when you attempt to control a monitor or cam- era that is already used by a higher priority operator, or when the higher priority operator selects the camera or monitor you are currently operating. Operations from the System Controller are disabled until this indicator goes off. iProhibited indicator (PROHIBITED) This indicator lights up for 3 seconds when an attempt is made to gain access to a function that is prohibited by the partition. AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELE FOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ALARM DISARM ACKRESET GROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICE CAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFT DEF OFFDEF ON AUX2 OFFAUX2 ON AUX1 OFFAUX1 ON CAM ID OPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUS WIPER GEN ALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAUTO PA N UP LR DOWN MONITOR CAMERA For Matrix Switcher (System 850) WV-CU C360 CAMERA SITE CONTROL System Controller !9 @0 @1 @2 @3 @4 @5 @6 @7 @8 qwetryui o!0!2!1!3!4!5!6!7!8#2#1@9#0
67 oJoystick Controller (UP/DOWN/L/R) Used to manually operate the Pan/Tilt Head, or move the cursor in the camera menu on the active monitor screen. UP: Upward DOWN: Downward L: Left R: Right !0Iris buttons (IRIS, CLOSE/OPEN) Closes or opens the lens iris of cameras equipped with the specified lens. When these buttons are pressed at the same time, the lens iris is reset to the factory default setting. !1Focus buttons (FOCUS, NEAR/FAR) Adjusts the lens focus of cameras equipped with the specified lens. When these buttons are pressed at the same time, the lens focus is set automatically if the specified camera with the auto focus feature is equipped. !2Zoom buttons (ZOOM, WIDE/TELE) Zoom the image in or out if the camera is equipped with the specified lens. !3Programme Preset button (PROGRAM PRESET) In combination with the numeric buttons and CAMERA (ENTER) button, saves a preset position of the camera in a system equipped with the specified cameras. To save a preset position, move the camera to the posi- tion to be preset and select a preset number by press- ing the numeric buttons. Hold down the PROGRAM PRESET button, then press the CAMERA (ENTER) but- ton. !4Call Preset button (CALL PRESET) In combination with the numeric buttons, moves the pan/tilt head of the selected camera to a preset position in a system equipped with the specified cameras. !5Camera/Enter button [CAMERA (ENTER)] CAMERA:Used for camera selection. Select a camera by pressing the corresponding numeric buttons, fol- lowed by the CAMERA (ENTER) button. ENTER:In combination with the numeric buttons, enter numeric input, such as operator ID and password. It is also used to execute the currently highlighted selection and enter a submenu of the camera menu. Pressing CAMERA (ENTER) while holding down the SHIFT button will activate the auto panning function of the selected camera (AUTO PAN).!6Clear/Escape button [CLEAR (ESC)] Clear:Clears numeric input from the LED display. Escape:Escapes from the currently highlighted selec- tion and return to the previous page of the camera menu. This button is also used to exit from alarm selection mode to normal operation mode. !7Numeric buttons (0 - 9) Used for numeric input into the system such as the camera and monitor number, sequence number, preset position, etc. Pressing the buttons shown below while holding down the SHIFT button will select special functions. 1:Turns off the user auxiliary 1 switch of the receiver. (AUX1 OFF) 2:Turn on the user auxiliary 1 switch of the receiver. (AUX1 ON) 3:Turns on the housing wiper of the camera until these buttons are released. (WIPER) 4:Turns off the user auxiliary 2 switch of the receiver. (AUX2 OFF) 5:Turns on the user auxiliary 2 switch of the receiver. (AUX2 ON) 7:Turns off the housing defroster of the camera. (DEF OFF) 8:Turns on the housing defroster of the camera. (DEF ON) !8Shift button (SHIFT) Pressing this button in combination with buttons to which a special function has been assigned will acti- vate these functions. !9Alarm button (ALARM), Disarm indicator (DISARM) In combination with the Numeric buttons, selects an alarm. To select an activated alarm, press the numeric buttons, followed by the ALARM button. Pressing this button repeatedly enables or disables the cameras and monitor assigned to perform the alarm activities. The DISARM indicator next to the button is lit while alarm activities are disabled. @0Alarm Acknowledge button (ACK) Acknowledge an activated alarm. Select the alarm by pressing the numeric buttons, followed by the ALARM button. Select the desired alarm action number by pressing the numeric buttons, then press the ACK but- ton. The ACK indicator will light. After acknowledging the alarm, press the RESET button to reset the alarm. The ACK indicator will go off.
68 @1Alarm Reset button (RESET) Cancels an activated alarm. Press this button to reset an alarm activated in the cur- rently active unit. Pressing this button while holding down the SHIFT but- ton cancels all currently activated alarms at a time (ALL RESET). Pressing RESET in the camera menu will reset the para- meter of a selected item or open the Special camera menu when the cursor is positioned on SPECIAL in the menu. Pressing it while holding down the SHIFT button will restore all factory default settings. @2Group Preset button (GROUP PRESET) In combination with the numeric buttons, activates a previously programmed Group Preset function. Pressing this button while holding down the SHIFT but- ton will display the Operator ID number on the LED Display for about 3 seconds (OPE ID). @3Previous button (PREV) Moves a Tour Sequence one step backward from the step that was previously paused on the active monitor by pressing the PAUSE button. This button is also used to select a camera. Pressing PREV while holding down the CAMERA (ENTER) button will replace the currently selected camera with the next lower camera number, if the active monitor is in Spot mode. Similarly pressing PREV while holding down the MONI- TOR button will select the next lower monitor number. When selecting alarms, pressing PREV while holding down the ALARM button will select the previous alarm. Pressing this button while holding down the SHIFT but- ton will display the Controller ID number on the LED Display for about 3 seconds (S-CTL ID). @4Next button (NEXT) Moves a Tour Sequence one step forward from the step that was previously paused on the active monitor by pressing the PAUSE button. The button is also used to select a camera. Pressing NEXT while holding down the CAMERA (ENTER) button will replace the currently selected camera with the next higher camera number, if the active monitor is in Spot mode. Similarly pressing NEXT while holding down the MONI- TOR button will select the next higher monitor number. When selecting alarms, pressing NEXT while holding down the ALARM button will select the next alarm. @5Log Out button (LOG OUT) In combination with the CAMERA (ENTER) button, logs out from the system. To prevent a log-out error, press CAMERA (ENTER) while holding down the LOG OUT button.@6Pause button (PAUSE) Pauses a Tour or Group Sequence that is being run on the active monitor. Pressing PAUSE while holding down the SHIFT button will close the camera menu on the active monitor. The STOP indicator will go off. (CAM MENU OFF) @7Stop button (STOP) Ends a Tour Sequence that is being run on the active monitor. To end a Group Sequence, select one of the monitors that displays the selected sequence, then press this button. Pressing STOP while holding down the SHIFT button will open the camera menu on the active monitor. The STOP indicator will light. (CAM MENU ON) @8Function buttons (F1, F2) Provide access to camera attributes and operating functions. F1:Reserved for future use. F2:Pressing this button will select the mode for control- ling selected camera functions (CAM FUNC). @9Group Sequence button (GROUP SEQ) In combination with the numeric buttons, runs a Group Sequence on the assigned monitors. Pressing GROUP SEQ will restart a forward sequence from the next step that was previously paused by pressing the PAUSE button. #0Tour Sequence button (TOUR SEQ) In combination with the numeric buttons, runs a Tour Sequence on the active monitor. Pressing TOUR SEQ will restart a forward sequence from the next step that was previously paused by pressing the PAUSE button. #1OSD (On Screen Display) button (OSD) Displays or hide some of the information on the screen of the selected monitor. Press the numeric buttons shown below, then press the OSD button. 1:Clock Display (T&D) 2:Camera Title Display (CAM ID) 3:General Status Display (GEN) 5:Monitor Status Display (MON STATUS) 6:All Displays except clock (ALL)
69 #2Monitor/Monitor Lock/OSD service button (MONITOR/OSD SERVICE), Lock indicator (LOCK) Selects a monitor by entering a monitor number with the numeric buttons, and then pressing this button. To lock or unlock the currently selected monitor, press this button while holding down the SHIFT button. While the LOCK indicator is lit, other operators will be barred from accessing the monitor. To access OSD service, press the numeric buttons shown below, then press this button. 1:ALMS, Alarm status 2:VLDS, Video loss detection status 3:SYS S, System status 4:ALM H, Alarm history 5:VLDH, Video loss detection history
70 INSTALLATIONS (For System 850) The installation should be made by qualified service personnel or system installers according to the following instructions. CAUTION System Connections Connection Example The connection example shows a large-scale system having a number of cameras, alarm sensors, monitors and so forth con- nected to the System 850 Matrix Switcher. The System Controller WV-CU360C provides major operating functions to control the system. Cameras Combination Cameras Video Monitors Time Lapse VCRs Sensors System 850 Matrix Switcher System Controllers AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAUTO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAUTO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAUTO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAUTO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAU TO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAU TO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAUTO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller AUTO FOCUS OPERATE LINK ALARMBUSYPROHIBITED IRIS CLOSE OPEN NEAR FAR WIDE TELEFOCUS ZOOM IRIS RESET PREV SEQ SEQTOURGROUP ARARMDISARMACKRESETGROUP PRESET NEXT LOG OUT PAUSE STOP F1 F2 MONITOR CAM FUNC LOCK OSD SERVICECAMERA (ENTER) CLEAR (ESC)CALL PRESET PROGRAM PRESET SHIFTDEF OFFDEF ONAUX2 OFFAUX2 ONAUX1 OFFAUX1 ONCAM IDOPE IDS-CTL ID OSD CAM MENU OFFCAM MENU ON ALL RESET MDN STATUSWIPERGENALL EXIT BLK VLD H ALM HVLD S SYS S ALM SAUTO PA N UP LR DOWN MONITOR CAMERAFor Matrix Switcher (System 850)WV-CU C360CAMERA SITE CONTROLSystem Controller System Controller WU-CU 850
71 DC 9V IND ATA MODE CONTROLLER No.0987654321 DC 9V IND ATA MODE CONTROLLER No.0987654321DC 9V IND ATA MODE CONTROLLER No.0987654321 DC 9V IND ATA MODE CONTROLLER No.0987654321 PARALLELSATELLITE MODE REDUNDANT CPU ETHERNET 1 CAMERA CROSS POINT OSD SYSTEM CONTROLLER DATA 6 DATA 5 DATA 4 DATA 3 DATA 2 DATA 1 PERIFERAL INTERFACE ( RS– 232C)( RS– 485) SYSTEM CONTROLLER2 3SATELLITE STANDALONEYES NO AC IN Central Processing Unit 125V 3.0A SIGNAL GND Main CPU DATA Port Connection Data ports are connected with RS-485 cables among devices using Camera Communication protocol as follows. Note:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication. •Internal Diagram •Basic Connection Data Flow – Main CPU ← WV-CU360C Main CPU ← WV-CU360C Main CPU → WV-CU360C Main CPU → WV-CU360C – 1 61 6 No.No. 11 22 33 44 55 66 Name GND TX(B) TX(A) RX(B) RX(A) GND Controller endTX (B) TX (A) RX (A) RX (B)
72 Controller Number Setting Set this switch always to 1 when using the System Controller in a System 850. Switch Setting Procedures Set the MODE DIP switch and CONTROLLER NO. switch as follows. 1. Remove the DC plug from the rear of the controller. 2. Set the switches as follows. • Bit 1 should be set to OFF*. • Bit 2 should be set to ON. • Bit 3 should be set to OFF*. • Bit 4 should be set to OFF*. • Bit 5 should be set to ON* when connecting with a System 850 in a home run (one to one) fashion. • Bit 6 should be set to OFF* (Operator) normally, or ON (Administrator) when setting up the controller. • Bit 7 should be set to ON. The baud rate is selected in the controller setup. • Bit 8 should be set to OFF* normally. 3. Connect the DC plug to the controller. SW position OFF See below See below See below Not used On* Administrator Set up from CU360 3 times Function ON Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8System ID System ID System ID Reserved Line termination Operation mode Baud Rate Selection Repeat Transmissions* * * * Off Operator* Auto-selection* 1 time* MODE 123456 78 OFF ON 0987654321 CONTROLLER No. DIP Switch Setting An 8-bit DIP switch mounted on the rear panel specifies communication mode, etc. The default position is marked with an asterisk *. DC 9V IND ATA MODE CONTROLLER No.0987654321