Have a look at the manual Panasonic System Controller Wv Cu360c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
42 @5Preset Position button (PRE - POSI) In combination with the numeric buttons and CAM (SET) button, moves the camera to the desired preset position. @6Still button (STILL) Freezes the picture on the multiscreen monitor. The indicator lights up when the still mode is selected. @7Camera Set buttons (CAMERA SET ON/OFF) Open or close the camera setup menu on the monitor screen. ON:Opens the selected camera setup menu on the monitor, if applicable. The indicator lights up when the camera setup menu is displayed. OFF:Closes the camera setup menu. @8Set Up button (SET UP ON/OFF) Opens or closes the WJ-FS616/FS616C setup menu on the monitor.
43 INSTALLATIONS (For WJ-FS616/FS616C) The installation should be made by qualified service personnel or system installers according to the following instructions. Warning! System Connections Connection Example The connection example shows cameras and an alarm sensor connected to the Video Multiplexer. A time lapse VCR will record pictures for later playback. The spot monitor and multiscreen monitor will display live and playback pictures while these devices are being operated from System Controller WV-CU360C. 481216 371115 261014 15913 PUSH OPEN16 POWERLOCKON OFF ALARMMULTI SCREENMULTISCREENSELECT RESET SPOT SEQUENCE VCR CAMCAMERA/PRESET POSITION Video Data RS-485 Video Multiplexer WJ-FS616C Time Lapse VCR Personal Computer (Software) System Controller WV-CU360CSpot Monitor Live 1-16chMultiscreen Monitor Live 1-16ch Playback 1-16ch RS-232C/WiredAlarm Sensor AUXAlarm System ControllerOPERATE LOCK ALARMSPOTAUTO/+IRISCLOSE OPEN NEAR FAR TELE WIDEFOCUSZOOM IRIS RESETVTR CAM MULTI SCREENSEQUENCEEL-ZOOMMULTI SELECTSTILLPRE-POSI ALTALM RESETALM SUSPENDFUNCTIONALL RESET CAMERA SETON OFF ON/OFFSETUPAUTO FOCUS HOME/-UNITCAM ESC SET UP LR DOWN UNITCAMERAFor MultiplexerWV-CU C360 T/L MODE CAMERA SITE CONTROL AUX 2AUX 1
44 DATA Port Connection (For Multiplexer) Data ports are connected with RS-485 cables among devices using the Camera Communication protocol as follows. Note:When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication. •Internal Diagram •Basic Connection DIP Switch Setting (For Multiplexer) An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an asterisk *. System Controller WV-CU360C D ATA RS-485 Cable Termination: ON Termination: ON TERM. OFF IN OUT OND ATA Video Multiplexer WJ-FS616C DC 9V IND ATA MODE CONTROLLER No.0987654321 SW position OFF Not used On* Administrator Not used Not used Function ON Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8Unit Version Unit Version Unit Version Reserved Line termination Operation mode Reserved Data transmissionSee Unit Version* See Unit Version* See Unit Version* Fixed to OFF* Off Operator* Fixed to OFF* Fixed to OFF* Data Flow – WJ-FS616C ← WV-CU360C WJ-FS616C ← WV-CU360C WJ-FS616C → WV-CU360C WJ-FS616C → WV-CU360C – 1 61 6 No.No. 11 22 33 44 55 66 Name GND TX(B) TX(A) RX(B) RX(A) GND Controller endTX (B) TX (A) RX (A) RX (B)
45 Controller Number Setting Set this switch always to 1 when using the System Controller in a system including a Multiplexer WJ- FS616/FS616C. Switch Setting Procedures 1. Remove the DC plug from the rear of the controller. 2. Set the MODE switch referring to the table. • The bit switches #1 to #3 should be set to positions that match the version of the Multiplexer installed in the sys- tem. • Bit 5 opens or terminates the communication chain. The switch should be set to OFF when the controller is locat- ed in an intermediate position of the chain. • Bit 6 specifies either Operator or Administrator as the operation mode. Set to Administrator when setting up the controller. • Bits 4, 7 and 8 are reserved. 3. Set the CONTROLLER NO. switch to 1. 4. Connect the DC plug to the controller. Unit Version The unit ID is defined by the upper 3 bits depending on the software version installed in the unit. •WJ-FS616 •WJ-FS616C MODE 123456 78 OFF ON MODE 123456 78 OFF ON 0987654321 CONTROLLER No.
46 SETUP PROCEDURES (For WJ-FS616/FS616C) To display the setup menus for the WV-CU360C System Controller on the LED display, set the MODE switch and power up the controller as described below. Prior to Setup Do the following before entering the setup mode. 1. Confirm that all necessary connections and switch set- tings are complete. 2. With the power turned off, move bit #6 of the MODE switch on the rear to ON (administrator) position. 3. Supply power to the controller. 4. Turn on the power of cameras and other system units. 5. The LCD displays [SEtUP]. The controller is ready to enter the setup mode. When setup is completed, restore the switch to its original position. 1. With the power turned off, move bit #6 of the MODE switch on the rear to OFF (operator) position. 2. Supply power to the controller. Buttons and Controls used for Setup The following buttons and joystick operations are used for setup. 0 9Numeric buttons: To select a parameter CAM/SET button: To execute modes and parameters To enter a submenu UNIT/ESC button: To return to the previous menu CAM SET UNIT ESC DOWN LRUP LR UP DOWNR UP DOWN LR Up: To select a setup menu Down: To select a setup menu Left: To decrease the parameter Right: To increase the parameter HOME/- AUX 1 AUTO/+ AUX 2 or or
47 Controller Setup Set up the baud rate and parity check mode for the controller while observing the LED on the front panel. Administrator Authorization 1. Press the CAM/SET button while [SEtUP] is displayed. The [- - - - -] prompt appears. 2. Enter a password with the numeric buttons, then press the CAM/SET button. The default setting is [12345]. 3. If the password entered is valid, [SPEED] appears. If password entry failed, the menu returns to [SEtUP]. Baud Rate In this menu, the communication speed (bps: bits per sec- ond) is selected. The communication speed should match that of the WJ-FS616/FS616C. 1. Display [SPEED] and press the CAM/SET button twice. 2. Select a parameter entering a bracket-enclosed num- ber, e.g., (3), moving the joystick to right and left, or pressing the [+] and [–] buttons. The default setting is 9 600 bps. (1) 2 400:2 400 bps (2) 4 800:4 800 bps (3) 9 600:9 600 bps (4) 19 200:19 200 bpsNote:Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an activated alarm is reset). 3. Press the CAM/SETbutton to validate the selection. 4. Press the ESCbutton to go back to the previous menu. Parity In this menu the parity check mode is selected. 1. Display [PrtY] and press the CAM/SETbutton twice. 2. Select a parameter with the joystick. The default setting is None. n:None E:Even parity 3. Press the CAM/SETbutton to validate the selection. Menu Selection Move Joystick UP and down to selectSetup Menus Parameter Selection (default*) LED Display blinking Setup Administrator Password Prompt Speed ParityInitial Display Authorization Baud Rate (bps)Press twice Parity Check CAM SET CAM SET MON ESC LED prompts you to enter pass- word Enter a 5-digit password, press (12345*) (1) 2 400 (2) 4 800 (3) 9 600* (4) 19 200 (1) None* (2) Even Reading Function OK No DOWN LRUP LR CAM SET
48 4. Press the ESCbutton to go back to the previous menu. Note:The baud rate and parity check mode of both the WJ-FS616/FS616C and the controller must be the same, otherwise data communications will not function. To confirm the WJ-FS616/FS616C setup, open the COM PORT SETUP window to check the DATA port column parameters. Refer to Multiplexer Setup for operation. COM PORT SETUP RS-232C DATA RS-485 DELAY OFF OFF OFF BAUD RATE 9600 9600 19200 WAIT TIME OFF OFF OFF DATA BIT 7 8 8 PARITY ODD NONE NONE STOP BIT 1 1 1 XON/XOFF - OFF OFF FULL/HALF - - FULL
49 OPERATING PROCEDURES (For WJ-FS616/FS616C System) Camera Selection One of the cameras connected to the system unit is select- ed. 1. Enter a camera number using the numeric buttons. The number appears on the LED display. 2. Press the CAM/SETbutton. Note:[--] appears in the camera section of the LED dis- play when an alarm is activated, when the multi- screen is displayed, or when sequence mode is run. The following functions of the camera are controlled. • Pan/tilt • Focus • Zoom • Iris • Defroster ON/OFF (camera housing) • Wiper ON/OFF (camera housing) • Preset Position (Combination Camera) • Home position (Combination Camera) • Auto pan (Combination Camera) The following additional functions can be controlled when using the WV-CS854 or later camera models. • Switching between color and B/W picture (Combination Camera) • Patrol Learn function (Combination Camera) • Camera functions (Combination Camera) Camera Control Cameras and their peripherals are controlled from the WV- CU360C as follows. Some of the descriptions may not be applicable if they refer to devices not equipped in your sys- tem. Pan/Tilt Control Proceed as follows to control an ordinary camera mounted on a pan/tilt head or a combination camera in manual or automatic panning mode. 1. Move the pan/tilt head in the desired direction with the joystick controller. 2. Press the AUTO/+button to activate a preset auto pan- ning. AUX Control This allows you to control an auxiliary device such as a buzzer or lamp connected to the Receiver or combination camera. 8Auxiliary 1/2 1. Press the ALTbutton to turn on the ALTindicator . 2. Press the AUX 1or AUX 2button to operate or cancel the auxiliary function for the selected camera. Note: For common operations to the controller and the WJ-FS616/FS616C, please refer to the manual included with the WJ-FS616/FS616C. The following pages describe only operations different from the WJ-FS616/FS616C. UNITCAM ESC SET CAM SET UP LR DOWN ALTAUTO/+ HOME/- AUX 2 AUX 1
50 Note:Auxiliary control may be ignored while zooming, focusing or panning/tilting is in operation. Alarm Operation When the WV-CU360C receives an alarm signal from the WJ-FS616/FS616C, the alarm indicator blinks. The alarm indicator changes from blinking to steady light when the alarm is automatically reset. The camera number appears in the camera section of the LED display. Alarm Reset 1. Press the ALM RESETbutton while the ALTindicator is not lit. An activated alarm is reset and the alarm indica- tor on the controller goes off. 2. To reset all alarms issued by the multiplexers connect- ed in a daisy chain, press the ALTbutton, then press theALM RESETbuttons. Alarm Suspension 1. Press the ALM SUSPENDbutton for more than 2 sec- onds to suspend the alarm. The ALM SUSPENDindi- cator lights up. 2. Press the ALM RESETbutton to reset alarm suspen- sion. The ALM SUSPENDindicator goes off. VTR (VCR) Control You can operate a VTR (VCR) connected to the Video Multiplexer from the controller using the buttons listed below with the ALT indicator lit. Function Rewind Pause Fast Forward Reverse Play Stop Playback T/L (time- lapse) Mode Down Up RecordingLogoNote e.g., change from 72H mode to 24H mode e.g., change from 24H mode to 72H mode ALM RESET ALL RESET ALM RESET ALL RESET ALM SUSPEND
51 Camera Setup The cameras connected to the WJ-FS616/FS616C are set up from the controller. Note: Make sure that the multiplexer and the controller are set to identical communication parameters. General Setup 1. Select a camera pressing the numeric buttons, then press the CAM/SET button. 2. Press the CAMERA SET ONbutton. The ON indicator is lit while the CAMERA SET UP MENU is displayed on the monitor. 3. Select a setup item by moving the joystick up and down. Select a parameter by moving the joystick to the right or left, then press the CAM/SETbutton to validate the selection or to enter a submenu. 4. Press the UNIT/ESCbutton to execute the selection and to return the menu to a higher layer. 5. Press the SEQUENCEbutton to enter the SPECIAL menu.6. Press the VTR/CAMbutton to reset all functions to the defaults, or press the SEQUENCEbutton to reset a selected function. 7. Press the CAMERA SET OFFbutton to close the cam- era setup menu. Shortcut for Preset Position Setup A shortcut can be created for setting a camera position without going through the whole presetting process. Shortcuts are applicable only to cameras having the preset- ting function. 1. Open the PRESET menu of the camera. 2. Press the ALTbutton while the position setting menu is displayed. 3. Move the camera with the joystick to the position you wish to preset. 4. Adjust the picture with the IRIS, FOCUSand ZOOM buttons. 5. Press the ALTbutton again. The preset conditions are registered, and the joystick function reverts to moving the cursor. CAMERA SET ON OFF T/L MODE UP R DOWN CAM SET L UNIT ESC SEQUENCE VTR CAM CAMERA SET ON OFF T/L MODE