Page 41

41
Starting Up
1. Select Start – All Programs – Panasonic – WJ-
SX650 Series – WJ-SX650 Series Administrator
Console x.xx. (x.xx is the version number.) Then, run
the program.
WJ-SX650 Series Administrator Console will start up,
and the login window will be displayed on the PC
screen.
Note:When you select WJ-SX650 Series Administrator
Console x.xx (x.xx is the version number.) while
holding down the Ctrl key on the PC keyboard, the
language selection window will appear. (Keep hold-
ing down the Ctrl key...

Page 42

42
Reference No.
11
12
13
141 to 8: Camera unit number
Note:Camera unit number cannot be set for camera input channels accepting video input signals from
recorders. To activate RS-485 camera connections, set OFF for Control of these recorders in System
– Recorder.
ON: Overlap
OFF: Not overlap
S: Less than 400 m {1 300 ft}
M: 400 m {1 300 ft} to 700 m {2 300 ft}
L: 700 m {2 300 ft} to 900 m {3 000 ft}
Note:Refer to p. 27 for details on the cable length.
Tooltip Details
1
2
3
4
5
6
7
8
9
10Explanation
1...

Page 43

43
44 43
Reference No.
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
402005 to 2099: Year
1 to 12: Month
1 to 31: Day
[24-h time format] 0 to 23: Time
[12-h time format] 1 to 12: Time
00 to 59: Minute
AM, PM: Morning, Afternoon
DD/MM/YYYY, MM/DD/YYYY, YYYY/MM/DDDD, DD/Mmm/YYYY, Mmm/DD/YYYY: Date Format
Japanese, English, French*, Spanish*, German*, Italian*, and Russian*: Language
* In the actual display, these parameters are displayed in their own languages. 
[24-h] 0:00 to...

Page 44

64
44
Reference No.
46
47
48
49
50
51
52
53
541 to 1024: Alarm Output number
Alarm output signal is supplied from the ALARM OUT 1/2 port or the SERIAL port. (65 to 1024 are supplied
from the SERIAL port only as a serial command.)
Note:To activate serial command transmission, set Alarm Output to ON in Communication – Serial
Command.
Spot: Only the spot images can be activated for the alarm event.
Tour Sequence: Only tour sequences can be activated for the alarm event.
Group Sequence: Only group sequences...

Page 45

Display
Display
Date Format:Mmm/DD/YYYY
Time Format:12-h
Language:English*
DST/Summer Time
DST/Summer Time:ON*
Start Time:02:00 AM 
DST/Summer Time Table:The first Sunday in April to the
last Sunday in October 
Camera
Camera Title
Custom Chars: A to Z, a to f
Camera Position
Sequence
Tour Sequence
Tour Sequence 1:Images of LCN 1 to 32 are sequentially
switched for two seconds. 
Tour Sequence 2:Images of LCN 33 to 64 are sequentially
switched for two seconds. 
Tour Sequence 3:Images of LCN 65 to 96 are...

Page 46

46
Item Group Sequence
Group Sequence 1:4 cameras among LCN 1 to 64 are
sequentially switched for 2 seconds on Monitor 1 to 4.
Group Sequence 2:4 cameras among LCN 65 to 128 are
sequentially switched for 2 seconds on Monitor 5 to 8.
Group Sequence 3:8 cameras among LCN129 to 256 are
sequentially switched for 2 seconds on Monitor 9 to 16.
Group Sequence 4 to 8:No settings
Group Sequence 9:Spot image of LCN 1 to 16 are dis-
played on Monitor 1 to 16.
Group Sequence 10 to 32:No settings
Schedule
Timer...

Page 47

47
Controller
Monitor Access
Auto Login/Logout
Auto Login:All the ports are enabled. (Checked) (User ID:
650)
Auto Logout:All the ports are unabled. (Not Checked)
Key Assignment (Available for WV-CU950/650)
Communication
Serial Command
Alarm Notification:OFF
System Status Notification:OFF
Alarm Output:OFF
PS.Data
Unit Address: 1

Alarm Data: 1 sec
Retry Timing:OFF 

Recorder (HDR port):OFF
Whole PS.Data System (PSD port):OFF
Adjustment time:02:00 PM
Factory Default Settings of
SETUP MENU
SYSTEM...

Page 48

48
This chapter explains about SETUP MENU (On-screen
Display setup menu) of this unit.
Basic Operations
To control SETUP MENU, display SETUP MENU on a moni-
tor.
WV-CU950/650
1. Select a desired monitor. (Refer to p. 57 Monitor
Selection.)
2. Press the MENU button repeatedly until System Setup
appears on the LCD.
3. Press the F1 button. SETUP MENU will be displayed on
the selected monitor.
WV-CU360C/CJ
1. Select a desired monitor. (Refer to p. 57 Monitor
Selection.)
2. Press the SETUP button while...

Page 49

49
TIME & DATE
You will set the current time and date.
When you select TIME & DATE on the top menu, the follow-
ing menu is displayed.
Note:Display format setting is performed in Display –
Display of WJ-SX650 Series Administrator Console.
• Year
2005 to 2099
• Month
1 to 12 (When Date Format is set to DD/MM/YYYY,
MM/DD/YYYY, YYYY/MM/DDDD in WJ-SX650 Series
Administrator Console)
Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, Dec
(When Date Format is set to DD/Mmm/YYYY or
Mmm/DD/YYYY in WJ-SX650...

Page 50

50
• RECORDER ALARM
Select ON or OFF to accept or not accept recorder alarm
input signals. (The factory default is OFF.)
ON:Accepts recorder alarm input signals.
OFF:Not accepts recorder alarm input signals.
• SERIAL ALARM
Select ON or OFF to accept or not accept serial alarm input
signals. (The factory default is ON.)
ON:Accepts serial alarm input signals.
OFF:Not accepts serial alarm input signals.
• VIDEO LOSS
Select ON or OFF to accept or not accept video loss input
signals. (The factory default is...