Panasonic Matrix Switcher Wj Sx650p Operating Instructions
Here you can view all the pages of manual Panasonic Matrix Switcher Wj Sx650p Operating Instructions. The Panasonic manuals for Recording Equipment are available online for free. You can easily download all the documents as PDF.
Page 31
31 LCN LCN 1 to 16 17 to 32 33 to 48 49 to 64 65 to 80 81 to 96 97 to 112 113 to 128Recorder number (Unit Address (System)) Recorder number (Unit Address (System)) 1 2 3 4 5 6 7 8129 to 144 9 145 to 160 10 161 to 176 177 to 19211 12 VIDEO OUT 3 VIDEO OUT 4 VIDEO OUT 2IN X-2VIDEO OUT 1ALARM IN IN X-116 32 15 31 30 14 1329 28 12 1127 26 10 925CAMERA IN 24 8723 22 6521 20 4319 18 2117 EXTENSION 3 INEXTENSION 2 IN 4 MODERS485 (CAMERA) RS485 (CAMERA) 3 MODE MODE MODE 21 IN C-3 Unit Address (System): 1• •...
Page 32
32 Recorder number (Unit Address (System)) VIDEO OUT 3 VIDEO OUT 4 VIDEO OUT 2IN X-2VIDEO OUT 1ALARM IN IN X-116 32 15 31 30 14 1329 28 12 1127 26 10 925CAMERA IN 24 8723 22 6521 20 4319 18 2117 EXTENSION 3 INEXTENSION 2 IN 4 MODERS485 (CAMERA) RS485 (CAMERA) 3 MODE MODE MODE 21 IN C-3 BNC cable D-sub/BNC Video Cable WJ-CA68 32 31 30 25 24 17 16 9 8 1 RecorderRecorder Video input signals are supplied from recorders to the CAMERA IN 31 and 32. Video input board LCN: 17 to 32 Unit Address (System):...
Page 33
33 1 2 IN OUTCASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)D ATAAC IN SIGNAL GND1 42 1 2 IN OUTCASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)D ATAAC IN SIGNAL...
Page 34
34 Recorder Settings Be sure to perform the settings for connected recorders in SETUP MENU of recorders. You can set wto tafter connections. However, you must set qseparately for each recorder before connections. The settings are performed in SETUP MENU (Advanced) of each recorder. qUnit Address (System) Set the Unit Address (System) for each recorder in Comm – PS.Data Setup. 001 to 016 are available. (Up to 16 recorders can be connected.) The unit address setting must be different from each other....
Page 35
35 PS·Data Mode Connection To apply the PS·Data mode, connect the system controllers as follows. 1. Connect the system controllers to the DATA 1 port of Video Output Board 1. Notes: •In the factory default, the DATA 1 port is set for the ter- minal mode connection. To apply the PS·Data mode connection, perform the DATA port settings in DATA PORT of SETUP MENU (refer to p. 52) or System – DATA Port of WJ-SX650 Series Administrator Console. •Both of terminal mode and PS·Data system controllers cannot be...
Page 36
36 Alarm Sensor Connections Alarm input signals can be supplied by alarm sensors con- nected to the ALARM IN port at the video input board. The following are the ALARM IN port details. Notes: • Perform the setting of each signal polarity in TERMINAL ALARM of SETUP MENU (refer to p. 50) or Alarm – Alarm Mode – Terminal Setup of WJ-SX650 Series Administrator Console. •Perform the setting of each alarm event in Alarm – Alarm Event of WJ-SX650 Series Administrator Console. External Device Connections With...
Page 37
Time Adjust Input Time Adjust Output 37 Terminal Duration Remarks Alarm Output 1 to 32Until reset Open Collector output, 24 V, 100 mA maximum Alarm Recover Input 1 to 16100 or more msNon-voltage make con- tact output 1 second• Open Collector out- put, 24 V, 100 mA maximum • Signal is output every hour on the hour. 100 or more ms• Non-voltage make contact input • Signal input is accept- ed by up to ± 30 sec- onds every hour on the hour. Time is adjusted on the hour. Note:Alarm Recover Input 1 to 16 can be...
Page 38
38 Before operation, setup of this unit is required. Setup is per- formed from WJ-SX650 Series Administrator Console installed on a PC. (Some settings are available from SETUP MENU of this unit.) The following is an example of setup procedure. Notes: •Setup may differ depending on system composition. (Settings of Step 1 and 4 in the following procedure must be performed.) •For Step 2, 3, 5 and 6 in the following setup procedure, the factory default can be maintained. Example: camera x 150, recorder x 10,...
Page 39
39 VD2/DATA/CABLE COMPENSATION (Refer to p. 53.) 5. Perform the RS-485 camera settings. CAM001 to 150:If you use RS-485 cameras, select desired parameters for the RS-485 (CAMERA) ports and camera unit numbers. System – VD2/DATA/Cable Comp. – RS485 Camera RS485 CAMERA (Refer to p. 53.) 6. Perform the settings of cameras supplying video input signal to recorders. Recorder – LCN Setting (CAM 1 to 16):Set the LCNs of camera input connectors used for the loop-thru connections between the recorders and the...
Page 40
40 This chapter explains about WJ-SX650 Series Administrator Console. Before controlling WJ-SX650 Series Administrator Console, installation on the PC is required. System Requirements of a PC To install WJ-SX650 Series Administrator Console, the PC should meet the following requirements. OS: One of the following operating systems: Microsoft ®Windows®2000 Professional SP4 Microsoft®Windows®XP Professional SP2 Microsoft®Windows®XP Home Edition SP2 Note:To work WJ-SX650 Series Administrator Console on the...