Page 61

2.Insert the new extension bolts (included with the card) into the holes on the card, and tighten them to secure
the card.Document Version  3.0  2010/06Installation Manual612.8.1 4-Port Digital Expansion Card (KX-TVA204)Extension Bolt  

Page 62

Installing Cards in Slot 5 or Slot 6
When installing a card in Slot 5 or 6, secure the card using the screws included with the card, instead of the
extension bolts.
Note
•The KX-TVA204 operates at SELV.
62Installation ManualDocument Version  3.0  2010/062.8.1 4-Port Digital Expansion Card (KX-TVA204)Screw  

Page 63

2.8.2  Modem Card (KX-TVA296)The KX-TVA296 allows the VPS to be accessed remotely for administration purposes.
Included Items
Screw  ´ 1
Installation 1.Insert the card between the guide rails and slide it down as shown.
2. Secure the latch by flipping it toward the center of the card and slightly pressing down on it.
CAUTION
When installing optional cards, do not put pressure on the main board. Doing so may result in damage
to the VPS.
3. Insert and tighten the screw as shown.
Note
•The KX-TVA296...

Page 64

2.9  PBX Connections
2.9.1  Connecting to the PBX One jack of the VPS can be connected to 1 jack of the PBX. For APT/DPT Integration, use a 4-conductor cable
to connect the VPS and PBX. For Inband or No Integration (KX-TVA50 only), use a 2-conductor (T and R)
cable.64Installation ManualDocument Version  3.0  2010/062.9.1 Connecting to the PBXYGRBYGRB
4-Conductor Cable
Modular Connection
Outer PinsInner Pins
B: BLACK
R: RED
G: GREEN
Y: YELLOW
L5 Terminal wire
RJ-11
T4
R3
H2
RJ-11  

Page 65

2.9.2  Modular Plug ConnectionInsert the modular plug of each telephone cord into an available modular jack of the VPS.
Note•Connections should be made using solid twisted pair copper conductors and a minimum of 24 gauge
cables that comply with the electrical specifications for Category 3 wiring as detailed in the ANSI/EIA/
TIA-570A Building Wiring Standards. The maximum length of each VPS-PBX connection should be
under 100 m (330 ft.).
KX-TVA50
KX-TVA200
Document Version  3.0  2010/06Installation...

Page 66

2.10  PC ConnectionA PC connected to the VPS can be used to program various VPS settings.
2.10.1  USB Connection An on-site PC can be connected to the VPS via USB.
Note•We recommend using a USB cable of no more than 5 m (16 ft. 5 in.) in length.
66Installation ManualDocument Version  3.0  2010/062.10.1 USB ConnectionPCTo USB port
KX-TVA200 KX-TVA50  

Page 67

2.10.2  LAN ConnectionAn on-site PC can be connected to the VPS over a local area network (LAN). For the KX-TVA50, an optional
LAN Interface Card must be installed in the VPS.
Note
•Use a category 5 cross cable (user-supplied) when connecting the VPS to a switching hub.
2.10.3  Modem Connection To connect an off-site PC to the VPS remotely via modem, an optional Modem Card must be installed in the
VPS and the off-site PC must also be equipped with a modem.
Note
•Do not connect the modem directly to the...

Page 68

remote PC are routed to the extension port connected to the VPS modem. Note that the effective data
transfer rate of the internal modem (maximum 33,600 bps) will be subject to the throughput limitations
of the PBX.68Installation ManualDocument Version  3.0  2010/062.10.3 Modem Connection 

Page 69

2.11  Frame Ground Connection
IMPORTANTConnect the frame of the main unit to ground. The grounding plug of the AC cable provides some
protection from external noise and lightning strikes, but it may not be enough to fully protect the
unit. A permanent connection between ground and the ground terminal of the unit must be made.
1. Loosen the screw.
2. Insert a grounding wire (user-supplied).
Note
•Green-and-yellow insulation is required, and the cross-sectional area of the conductor must be
more than 0.75...

Page 70

2.12  Connecting the AC Adaptor1.Plug the DC connector of the AC adaptor into DC IN.
KX-TVA50
KX-TVA200
70Installation ManualDocument Version  3.0  2010/062.12 Connecting the AC AdaptorAC AdaptorDC Connector
DC IN 
2
1 AC Adaptor
DC Connector
DC IN
2
1  