2.9 [3] Group
PC Programming Manual 221
Value Range
None, 1–15
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.9.3 ICD Group Features—Log-in/Log-out
Maximum No. of Busy Extensions
Specifies the number of extensions that can accept calls simultaneously in the incoming call 
distribution group.
Default
Max.
Value Range
Max: Call arrives at an idle extension.
1–32 : Call will not arrive at an idle...

Page 222

2.9 [3] Group
222 PC Programming Manual
Programming Manual References
None
Feature Manual References
1.9.3 ICD Group Features—Log-in/Log-out
VIP Call Mode
Enables VIP Call mode, to prioritize calls received from multiple incoming call distribution groups.
Default
Disable
Value Range
Disable, Enable
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.9.6 ICD Group Features—VIP Call
Programmed Mailbox No....

Page 223

2.9 [3] Group
PC Programming Manual 223
Floating Extension Number
Specifies the floating extension number of the incoming call distribution group.
Note that groups that will have a mailbox using a VM in DPT integration must have extension numbers 
of 2–4 digits.
Default
Groups 001-064: 601–664
Groups 065-128: Not stored
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual...

Page 224

2.9 [3] Group
224 PC Programming Manual
Value Range
0–100
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.3.3 Call Log, Incoming
Group FWD Call from CO—Setting
Indicates the current FWD status for incoming CO line calls directed to the incoming call distribution 
group (reference only).
Default
Off
Value Range
Off, On
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group...

Page 225

2.9 [3] Group
PC Programming Manual 225
Feature Manual References
1.6.6 FWD (Call Forwarding)
Group FWD Call from Extension—Setting
Indicates the current FWD status for incoming intercom calls directed to the incoming call distribution 
group (reference only).
Default
Off
Value Range
Off, On
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.6.6 FWD (Call Forwarding)
Group FWD Call from...

Page 226

2.9 [3] Group
226 PC Programming Manual
2.9.10 [3-5-2] Incoming Call Distribution Group—Queuing Time 
Ta b l e
A Queuing Time Table can contain up to 16 sequences which control how calls waiting in a queue are 
handled. A maximum of 64 Queuing Time Tables can be programmed.
Queuing Sequence—Sequence 01–16
Specifies the command activated by the corresponding sequence.
Default
None
Value Range
None: Redirects the call to the next sequence
Overflow: Redirects the call to the overflow destination when there...

Page 227

2.9 [3] Group
PC Programming Manual 227
Value Range
Disable, Enable
Maintenance Console Location
2.9.11 [3-5-3] Incoming Call Distribution Group—Miscellaneous
Programming Manual References
None
Feature Manual References
1.9.1 ICD GROUP FEATURES
2.9.12 [3-5-4] Incoming Call Distribution Group—Member
Each incoming call distribution group can have a maximum of 32 members (extensions) assigned to 
it, and each member can have its own delayed ringing and Wrap-up time settings. An extension can 
be a member of...

Page 228

2.9 [3] Group
228 PC Programming Manual
Value Range
Max. 20 characters
Maintenance Console Location
2.9.12 [3-5-4] Incoming Call Distribution Group—Member
Programming Manual References
2.9.21 [3-9] PS Ring Group—Group Name
2.10.1 [4-1-1] Wired Extension—Extension Settings—Main—Extension Name
2.10.8 [4-2-1] Portable Station—Extension Settings—Main—Extension Name
Feature Manual References
1.9.1 ICD GROUP FEATURES
Delayed Ring
Specifies the delayed ringing setting of each member. (Applicable when the call...

Page 229

2.9 [3] Group
PC Programming Manual 229
Default
Not stored.
Value Range
Max. 20 characters
Maintenance Console Location
2.9.13 [3-6] Extension Hunting Group
Programming Manual References
None
Feature Manual References
1.9.7 Idle Extension Hunting
Hunting Type
Specifies the hunting type for the hunting group.
Default
Circular
Value Range
Circular: Circulates until the call is answered or overflowed
Terminated: Terminates at the last extension
Maintenance Console Location
2.9.13 [3-6] Extension Hunting...

Page 230

2.9 [3] Group
230 PC Programming Manual
Maintenance Console Location
2.9.13 [3-6] Extension Hunting Group
Programming Manual References
None
Feature Manual References
1.9.7 Idle Extension Hunting
2.9.14 [3-6] Extension Hunting Group—Member List
Each hunting group can contain up to 16 extensions. Select the hunting group to program from the 
Hunting Group No. list.
To assign members to the group, enter the extension numbers in Extension Number or click 
Extension Number Setting (see 2.1.6 Extension Number...