Home > Panasonic > Wireless PBX > Panasonic Kx Taw848 Programing Manual

Panasonic Kx Taw848 Programing Manual

Here you can view all the pages of manual Panasonic Kx Taw848 Programing Manual. The Panasonic manuals for Wireless PBX are available online for free. You can easily download all the documents as PDF.

Page 271

2.10 [4] Extension
PC Programming Manual 271
Default
Not stored.
Value Range
Max. 20 characters
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
None
Call Pickup Deny
Specifies whether calls can be picked up by other extensions.
Default
Disable
Value Range
Disable: Allows other extension users to pick up calls to your extension
Enable: Prevents other extension users from picking up calls to your extension...

Page 272

2.10 [4] Extension
272 PC Programming Manual
Programming Manual References
None
Feature Manual References
1.5.3 Executive Busy Override
Absent Message
Specifies the Personal Absent Message which, unlike the System Absent Message, can be 
customized for each extension.
Default
Not stored.
Value Range
Max. 16 characters
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
1.1.1 Absent Message
Intercom Call by Voice...

Page 273

2.10 [4] Extension
PC Programming Manual 273
Option 4
Slot
Indicates the slot position of each extension card (reference only).
Default
Current slot number
Value Range
Slot number
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
None
Por t
Indicates the por t number (reference only).
Default
Current port number
Value Range
Port number
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings...

Page 274

2.10 [4] Extension
274 PC Programming Manual
When changing the extension number, make sure that the extension port is not in use. If the extension 
number is changed while the port is in use, the new extension number will not come into effect.
Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
numbers of 2–4 digits.
Default
Starting at 101
(For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent 
extensions by...

Page 275

2.10 [4] Extension
PC Programming Manual 275
Value Range
No Line: No line is seized.
Idle: An idle CO line is seized automatically from the programmed trunk groups.
ICM: An extension line is seized.
F-1–F-36: A CO line programmed for a flexible CO button (F-1–F-36) is seized. A flexible CO button 
customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
2.10.4 [4-1-4]...

Page 276

2.10 [4] Extension
276 PC Programming Manual
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
1.3.9 Call Waiting Tone
LCS Recording Mode
Specifies whether to continue or stop recording the message in the extensions mailbox when the 
extension user answers a call that was being monitored.
Default
Stop Record
Value Range
Stop Record, Keep Record
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension...

Page 277

2.10 [4] Extension
PC Programming Manual 277
1.19.4 Voice Mail DPT (Digital) Integration
Option 5
Slot
Indicates the slot position of each extension card (reference only).
Default
Current slot number
Value Range
Slot number
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
None
Por t
Indicates the por t number (reference only).
Default
Current port number
Value Range
Port number
Maintenance Console Location
2.10.1...

Page 278

2.10 [4] Extension
278 PC Programming Manual
2.Set the status of the extension port to OUS, then INS.
When changing the extension number, make sure that the extension port is not in use. If the extension 
number is changed while the port is in use, the new extension number will not come into effect.
Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
numbers of 2–4 digits.
Default
Starting at 101
(For port 01 of the first extension card that is installed....

Page 279

2.10 [4] Extension
PC Programming Manual 279
Value Range
Language1–Language5
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
1.4.7 Display Information
Incoming Call Display
Selects which caller information is shown on the first line of the extensions display.
Default
Caller ID Name
Value Range
Caller ID Name, CO Line Name
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming...

Page 280

2.10 [4] Extension
280 PC Programming Manual
Feature Manual References
1.4.7 Display Information
Key Pad Tone
Specifies whether key pad tones are heard when dialing.
Default
On
Value Range
Off, On
Maintenance Console Location
2.10.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
None
Automatic Answer for CO Call
Enables the extension to answer an incoming CO line call automatically after a cer tain number of 
rings without going off-hook, when...
Start reading Panasonic Kx Taw848 Programing Manual