Page 201
2.9 [3] Group PC Programming Manual 201 Simplified Voice Message Tone Detection—Silence Enables the disconnection of an SVM-originated CO-to-CO line call by silence detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Simplified Voice Message Tone Detection—Continuous Enables the disconnection of an SVM-originated CO-to-CO line call by...
Page 202
2.9 [3] Group 202 PC Programming Manual Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Host PBX Access Code Group Name Specifies the name of the trunk group for programming reference. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References...
Page 203
2.9 [3] Group PC Programming Manual 203 Feature Manual References 1.8.5 Host PBX Access Code (Access Code to the Telephone Company from a Host PBX) 2.9.2 [3-1-2] Trunk Group—Local Access Priority Trunk groups can be assigned a priority for Idle Line Access. When making a CO line call by Idle Line Access, the PBX will search trunk groups for an idle CO line according to the priority assigned here. Trunk Group No. & Name Specifies the trunk group assigned to the corresponding priority level. Select the...
Page 204
2.9 [3] Group 204 PC Programming Manual Maintenance Console Location 2.9.3 [3-2] Extension Group Programming Manual References 2.9.4 [3-3] Call Pickup Group 2.9.6 [3-4] Paging Group 2.10.1 [4-1-1] Wired Extension—Extension Settings—Main—Extension Group 2.10.8 [4-2-1] Portable Station—Extension Settings—Main—Extension Group Feature Manual References 1.7.1 GROUP FEATURES Tenant Number Specifies the tenant to which the extension user group belongs. Default 1 Value Range 1–8 Maintenance Console Location...
Page 205
2.9 [3] Group PC Programming Manual 205 Value Range Max. 20 characters Maintenance Console Location 2.9.4 [3-3] Call Pickup Group Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES Pickup Group—1st–8th Selects the call pickup groups that the extension user group belongs to. One extension user group can be assigned to a maximum of 8 call pickup groups on this...
Page 206
2.9 [3] Group 206 PC Programming Manual Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.5 [3-3] Call Pickup Group—All Setting Programming Manual References 2.9.4 [3-3] Call Pickup Group Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES Extension Group 1–32 Specifies whether the extension user group belongs to the corresponding pickup group. Default ON for the same-numbered call pickup group Value Range ON (blue), OFF Maintenance Console Location 2.9.5...
Page 207
2.9 [3] Group PC Programming Manual 207 Extension Group Name Indicates the name of the extension user group (reference only). Default Extension User Group 1–32: Extension Group 01–32 Value Range Max. 20 characters Maintenance Console Location 2.9.6 [3-4] Paging Group Programming Manual References 2.9.3 [3-2] Extension Group—Extension Group Name Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging Paging Group—1st–8th Selects the paging groups that the extension user group belongs to. One...
Page 208
2.9 [3] Group 208 PC Programming Manual Paging Group Name Specifies the name of the paging group. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.7 [3-4] Paging Group—All Setting Programming Manual References 2.9.6 [3-4] Paging Group Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging Extension Group 1–32 Specifies whether the extension user group belongs to the corresponding paging group. Default ON for same numbered paging group Value Range ON, OFF...
Page 209
2.9 [3] Group PC Programming Manual 209 Paging Group Name Indicates the name of the paging group (reference only). Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.8 [3-4] Paging Group—External Pager Programming Manual References 2.9.7 [3-4] Paging Group—All Setting—Paging Group Name Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging External Pager 1 Specifies whether the external pager belongs to the corresponding paging group. Default ON Value Range ON...
Page 210
2.9 [3] Group 210 PC Programming Manual click Member List. For more information on ICD Groups, see 1.9.1 ICD GROUP FEATURES in the Feature Manual. Main Floating Extension Number Specifies the floating extension number of the incoming call distribution group. Note that groups that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Groups 001-064: 601–664 Groups 065-128: Not stored Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location...