Page 181
9.2 Extension [2] Programming Manual 181 Jack Indicates the jack number (reference only). Value Range 01–24 Extension Indicates the extension number and name (reference only). Value Range Extension no. and name specified in Ext. no. and Name on the 9.1.3 Numbering Plan [1-3] screen Programming Manual References 9.1.3 Numbering Plan [1-3]—Ext. no., Name Group No. Selects the extension group to which the extension belongs. Default All jacks: Group No. 1 Value Range 1–8 Programming Manual References [600]...
Page 182
9.3 CO [3] 182 Programming Manual Default All Group Numbers: Off [Terminated (when checked)] Value Range set, type set: On (checked), Off (unchecked) type: Circular (Circulates until the call is answered), Terminated (Terminates at the last extension) Programming Manual References [100] Hunting Group Set [101] Hunting Type Feature Manual References 1.1.67 Idle Extension Hunting 9.3 CO [3] 9.3.1 Line Mode [3-1] The distribution method of incoming outside (CO) line calls can be programmed for each outside...
Page 183
9.3 CO [3] Programming Manual 183 Value Range Normal, DIL (Jack 01–24), DISA (OGM 1–8), Modem, BV (BV 01–24) Programming Manual References [414-416] CO Line Mode—Day/Night/Lunch Feature Manual References 1.1.8 Built-in Voice Message (BV) 1.1.40 Direct In Line (DIL) 1.1.41 Direct Inward System Access (DISA) 1.1.99 PC Programming 9.3.2 Incoming / Outgoing [3-2] The authorization to make or receive outside (CO) line calls can be programmed for each extension. The extension settings of an outside (CO) line...
Page 184
9.3 CO [3] 184 Programming Manual Value Range 01–24 Extension Indicates the extension number and name (reference only). Value Range Extension no. and name specified in Ext. no. and Name on the 9.1.3 Numbering Plan [1-3] screen Programming Manual References 9.1.3 Numbering Plan [1-3]—Ext. no., Name Ringing for incoming CO calls—Day, Night, Lunch Selects whether the extension will ring or not for incoming outside (CO) line calls in each time service mode. If the extension is set to ring, the ring delay...
Page 185
9.3 CO [3] Programming Manual 185 Programming Manual References [405-407] Flexible Outward Dialing—Day/Night/Lunch Feature Manual References 1.1.71 Line Access, Outside (CO) Line—SUMMARY 1.1.76 Line Preference—Outgoing 9.3.3 Detail [3-3] Various settings can be programmed for each outside (CO) line. CO Indicates the outside (CO) line port number (reference only). Value Range 1–8 Connection Specifies which outside (CO) lines are connected to the PBX. Note that the numbers of unconnected outside (CO) lines...
Page 186
9.3 CO [3] 186 Programming Manual Programming Manual References [400] CO Line Connection Feature Manual References 1.1.71 Line Access, Outside (CO) Line—SUMMARY 1.1.76 Line Preference—Outgoing Dial Mode Selects the type of signal used to dial out using an outside (CO) line. Default All outside (CO) lines: DTMF Value Range DTMF, Pulse, Call Blocking Programming Manual References [401] Dial Mode Feature Manual References 1.1.39 Dial Type Selection Pulse Speed Selects the speed at which pulse signals are...
Page 187
9.3 CO [3] Programming Manual 187 Value Range Max. 8 codes (1 or 2 digits consisting of 0–9, , and #) Programming Manual References [403] Host PBX Access Code Feature Manual References 1.1.65 Host PBX Access Code (Access Code to the Telephone Company from a Host PBX) CO Line Group Selects the outside (CO) line group that each outside (CO) line is assigned to. Default CO 1–8 = CO Line Group 1–8 (e.g., CO 1: CO Line Group 1, CO 2: CO Line Group 2) Value Range 1–8 Programming Manual References [404] CO...
Page 188
9.3 CO [3] 188 Programming Manual Default All outside (CO) lines: 600 ms Value Range 80 ms, 100 ms, 160 ms, 300 ms, 600 ms, 900 ms, 1200 ms Programming Manual References [418] Flash/Recall Time Feature Manual References 1.1.56 External Feature Access (EFA) 1.1.60 Flash/Recall Automatic Line Access Specifies which outside (CO) line is seized automatically when an extension user dials the Automatic Line Access number (9). Default All outside (CO) lines: On Value Range On (checked), Off (unchecked)...
Page 189
9.3 CO [3] Programming Manual 189 CPC Signal Detection—Outgoing Enables the PBX to detect a CPC signal from outgoing outside (CO) line calls. If disabled, CPC signal detection is only activated during an incoming outside (CO) line call. Default All outside (CO) lines: Off Value Range On (checked), Off (unchecked) Programming Manual References [421] CPC Signal Detection—Outgoing Feature Manual References 1.1.31 Calling Party Control (CPC) Signal Detection Disconnect Time Selects the length of the...
Page 190
9.3 CO [3] 190 Programming Manual 9.7.2 Others [7-2]—Doorphone Ring Tone Pattern—Door 1–4 Feature Manual References 1.1.108 Ring Tone Pattern Selection 9.3.4 Local Carrier-based VM [3-4] The PBX supports voice mail service, which is an answering system offered by the telephone company, that can notify the called party of a message waiting. The settings of an outside (CO) line can be copied to other outside (CO) lines. Select the outside (CO) line whose settings you want to copy to other outside (CO)...