Page 61
,.............................- until the desired memory code number (01 through 20) appears , I _ .............................. ..- CDE= exchange code with 3 digits Nothing is stored -......-defaul t (all 20 memory codes) AB= ml[ : memory code 01 [?ll: memory code 20 Description The exchange code and area code usually differ for local and non-local calls, but in some circumstances an area code may be the same as a local exchange code. These are important when Type B or Type C is selected...
Page 62
~...-....,.............,....... until the desired memory number (01 through 20) appears _ . . . . . . . . . . . . . . . . . . . . CDE = area code with 3 digits Nothing is stored ‘.....,defauIt (all 20 memory numbers) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AB= ml] : memory number 01 for storage of an area code memory number 20 for storage of an area code Description For Service Class 3 (see “Toll Restriction” on page 3-li’), up to 20 area codes can be...
Page 63
,,........,..................... A= 111 : to select boundary class I+..... default 121: class 2 131: class 3 q 4 :class4 151: class 5 q 6 :class6 171: class 7 q : class 8 Description “Toll Restriction”, if it is programmed, prohibits CO Operator Calls. However, the desired extensions can be permitted to call to CO Operator by programming a boundary number of service class. CO Operator Calls are allowed at all the extension from service class 1 to the same service class number as the...
Page 64
,....................... until the desired mode appears Restriction : will be restricted by a Service Class.........default No Restriction: will not be restricted. Description Through programming, Toll restrictions (service classes 1 through 8) set for each extension can be applied to speed dialing, too. In the “Restriction” mode, Speed dialing is restricted by the Service Class. In the “No Restriction” mode, Speed dialing is not restricted by the Service Class. Programming 1. Dial (12)....
Page 65
~.............................. until the desired memory number (01 through 20) appears : ........................ CDE = exchange code with 3 digits Nothing is stored ......... default (all 20 memory numbers) I................................... AB=llb]: memory number 01 for storage of exchange code memory number 20 for storage of exchange code Description For Service Class 5 (See “Toll Restriction” on page 3-17) up to 20 exchange codes can be selected for use in local dialing (charged). All...
Page 66
:‘............................. until the desired memory number (01 through 20) appears :........................... CDE = exchange code with 3 digits Nothing is stored,-....default (all 20 memory numbers) i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AB=lO(r/: memory number 01 for storage of exchange code pi-q : memory number 20 for storage of exchange code Description For Service Class 7 (See “Toll Restriction” on page 3-17) up to 20 exchange codes can be...
Page 67
*.......................................... A= 111: to sound after 1 minute cl 2 :after 2 minutes 0: 3 after 3 minutes . . . . . . . ..default 141 : after 4 minutes 151 :after 5 minutes 0 6 : after 6 minutes 171 : after 7 minutes cl 8 :after 8 minutes q 9 :after 9 minutes Description An alarm tone indication will be heard at the holding extension to remind the user that he still has a call on hold. The reminder will sound after 3 minutes but can be changed. There are 9 choices ranging...
Page 68
_............................................. I until the desired time appears 30sec--default 1 min. 1.5min. 2min. _ Disable Description Example: When the handset of the holding extension is replaced back on call, you may have the automatic hold recall after the desired time elapses. 1.5 minutes= ~INIKFj~ jIzGFlMEMoRVI(ENDI The hold recall time set can be removed or Programming Table added at the customer’s request. See page 7-6. Programming 1. 2. 3. 4. 5. Dial (18). “Hold Recall...
Page 69
until the desired mode appears Description Programming If a call is transferred to an extension, and the other extension does not answer the transferred call within 30 seconds, the call will return to you. The time may be changed to 15 seconds. Refer to “Call Transfer-To Extension” on page 4- 18. 1. 2. 3. 4. 5. Dial (19). “Transfer Recall” will be displayed. Press NEXT button. “Time: 30 set” will be displayed and the “30” will blink. Press the SELECT button to alternate between “15 set”...
Page 70
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . until the desired time appears 1 ring delay 2rings delay 3rings delay _. default 4rings delay Description Enables programming the call forwarding delayed start time (after 1, 2, 3, or 4 rings) in case of no receiving the call when the “Call Forwarding-Busy or No Answer” (on page 4-26) feature is set. Programming 1. Dial (20). “Call FWD Delay” will be displayed. 2. Press the NEXT button. “3 rings delay” will be...