Home > Panasonic > Projector > Panasonic DLP Projector PT-DZ21K2 PT-DS20K2 PT-DW17K2 PT-DZ16K2 Operating Instructions

Panasonic DLP Projector PT-DZ21K2 PT-DS20K2 PT-DW17K2 PT-DZ16K2 Operating Instructions

Here you can view all the pages of manual Panasonic DLP Projector PT-DZ21K2 PT-DS20K2 PT-DW17K2 PT-DZ16K2 Operating Instructions. The Panasonic manuals for Projector are available online for free. You can easily download all the documents as PDF.

Page 81

Chapter 4 Settings — Menu navigation
ENGLISH - 81
Sub-menu itemFactory defaultPage
[WAVEFORM MONITOR] [OFF]123
[CUT OFF] ―125
*1 Only for PT-DZ21K2, PT- DS20K2, PT- DZ16K2
[PROJECTOR SETUP] 
Sub-menu item Factory defaultPage
[PROJECTOR ID] [ALL]126
[PROJECTION METHOD] [FRONT/FLOOR]126
[LAMP SELECT] [QUAD]126
[LAMP RELAY] [OFF]127
[BRIGHTNESS CONTROL] ―128
[STANDBY MODE] [NORMAL]133
[SCHEDULE] [OFF]133
[INITIAL STARTUP] [LAST MEMORY]135
[STARTUP INPUT SELECT] [LAST USED]135
[RS-232C] ―135
[STATUS] ―137...

Page 82

Chapter 4 Settings — Menu navigation
82 - ENGLISH
[NETWORK] 
Sub-menu itemFactory defaultPage
[DIGITAL LINK MODE] [AUTO]154
[DIGITAL LINK SETUP] ―154
[DIGITAL LINK STATUS] ―155
[NETWORK SETUP] ―155
[NETWORK CONTROL] ―156
[NETWORK STATUS] ―156
[DIGITAL LINK MENU] ―157
[Art-Net SETUP] [OFF]157
[Art-Net CHANNEL SETTING] [2]157
[Art-Net STATUS] ―158
Note
 fSome items may not be adjusted or used for certain signal formats to be \
input to the projector .
When the items cannot be adjusted or used, the items in...

Page 83

Chapter 4 Settings — [PICTURE] menu
ENGLISH - 83
[PICTURE] menu
On the menu screen, select [PICTURE] from the main menu, and select an item from the sub-menu.
Refer to “Navigating through the menu” (x
  page   77) for the operation of the menu screen.
[PICTURE MODE]
You can switch to the desired picture mode suitable for the image source \
and the environment in which the 
projector is used.
1)
 
Press 
 as to select [PICTURE MODE].
2)
 
Press 
 qw.
 fThe 

[PICTURE MODE] individual adjustment screen is...

Page 84

Chapter 4 Settings — [PICTURE] menu
84 - ENGLISH
Attention
 fAdjust [BRIGHTNESS] first when you need to adjust the black level.
[BRIGHTNESS]
You can adjust the dark (black) part of the projected image.
1)
 
Press 
 as to select [BRIGHTNESS].
2)
 
Press 
 qw or the  button.
 fThe 

[BRIGHTNESS] individual adjustment screen is displayed.
3)
 
Press 
 qw to adjust the level.
Operation AdjustmentRange of adjustment
Press w. Increases the brightness of the dark (black) parts of the screen.
-31 - +31
Press q....

Page 85

Chapter 4 Settings — [PICTURE] menu
ENGLISH - 85
[USER1]Adjusts white balance as desired. Refer to “Adjusting desired white balance” ( x
  page   85) for 
details.
[USER2]
[3200K] - [9300K] Allows you to set in increments of 100
  K. Select so that images become natural.
Note
 fWhen [PICTURE MODE] ( x   page   83) is set to [USER] or [DICOM SIM.], [DEFAULT] cannot be selected. fWhen [COLOR MA
TCHING] (x   page   108) adjustment is set to other than [OFF], [COLOR TEMPERATURE] is fixed to [USER1].
 fThe...

Page 86

Chapter 4 Settings — [PICTURE] menu
86 - ENGLISH
6) Press the  button.
 fThe confirmation screen is displayed.
7)

 
Press 
 qw to select [OK], and press the  button.
 fThe [USER1] or [USER2] data is overwritten.
 fIf you press 

qw to select [CANCEL] and then press the  button, the data will not be overwritten.
 fThe 

[WHITE BALANCE HIGH] screen is displayed.
8)
 
Press 
 as to select [RED], [GREEN], or [BLUE].
9)
 
Press 
 qw to adjust the level.
Note
 f Adjust [COLOR  TEMPERATURE] correctly. All...

Page 87

Chapter 4 Settings — [PICTURE] menu
ENGLISH - 87
Note
 fDICOM is an abbreviation of “Digital Imaging and COmmunication in Medicine” and is a standard for medical imaging devices.  Although the 
DICOM name is used, the projector is not a medical device, and should not be used for purposes such as diagnosis of display images.
Changing the name of [USER1] or [USER2]
1) Press  as to select [GAMMA].
2)  
Press 
 qw or the  button.
 fThe 

[GAMMA] individual adjustment screen is displayed.
3)
 
Press 
 qw to...

Page 88

Chapter 4 Settings — [PICTURE] menu
88 - ENGLISH
[NOISE REDUCTION]
You can reduce noises when the input image is degraded and noise is occur\
ring in the image signal.
1) 
Press 
 as to select [NOISE REDUCTION].
2)
 
Press 
 qw or the  button.
 fThe 

[NOISE REDUCTION] individual adjustment screen is displayed.
3)
 
Press 
 qw to switch the item.
 fThe items will switch each time you press the button.
[OFF] No correction.
[1] Slightly corrects the noise.
[2] Moderately corrects the noise.
[3] Strongly...

Page 89

Chapter 4 Settings — [PICTURE] menu
ENGLISH - 89
ItemAdjustment
[DYNAMIC GAMMA] (Adjustment of signal  compensation) [OFF]
No correction.
[1] Slightly compensates the signal.
[2] Moderately compensates the signal.
[3] Strongly compensates the signal.
Note
 fWhen [DYNAMIC GAMMA] is set to [3], the contrast will be maximized. fBrightness control and dynamic iris operate simultaneously
, but the iris is fully open and does not operate while the brightness i\
s being 
measured.
[SYSTEM SELECTOR]
The...

Page 90

Chapter 4 Settings — [PICTURE] menu
90 - ENGLISH
sRGB-compliant video
sRGB is an international standard (IEC61966-2-1) for color reproduction defined by IEC (International 
Electrotechnical Commission).
Set according to the following steps to reproduce more faithful, sRGB compliant colors.
1)
 
Set [COLOR MA
 TCHING] to [OFF].
 fRefer to [COLOR MA

TCHING] (x   page   108).
2)
 
Display the [PICTURE] menu.
 fRefer to “[PICTURE] menu” (

x   page   83).
3)
 
Press 
 as to select [PICTURE MODE].
4)
 
Press...
Start reading Panasonic DLP Projector PT-DZ21K2 PT-DS20K2 PT-DW17K2 PT-DZ16K2 Operating Instructions

Related Manuals for Panasonic DLP Projector PT-DZ21K2 PT-DS20K2 PT-DW17K2 PT-DZ16K2 Operating Instructions

All Panasonic manuals