Page 81
81 ■ Mode Switch RS485 interface is used to communicate between this unit and the PS·Data compatible system device. In this case, it is neces- sary to terminate both devices on both ends of the RS485 connection. The settings of the mode switch will be different depending on whether this unit is used as a receiver or a controller. When an RS 485 camera is connected to this unit, it is necessary to terminate both devices on both ends of the connection. •When connecting this unit with the system controller...
Page 82
@5 Pin No. 82 ■ How to Use the Terminals of the ALARM/CONTROL Connector These terminals are used for emergency recording, auto time adjustment (Auto Adjust Time), taking measures against power outages (Shutdown Time), and when installing a buzzer, a lamp, or similar alarm device. They are also used to synchronize with the sequential display changeover. The terminal pin array and connections are shown below. The con- nector used should be compatible with the pin configuration. Pin array The pin array is...
Page 83
83 ● Connection for emergency recording When the external switch is turned ON, emergency recording will be started. Resolution, recording time, recording rate and quality for emergency recording can differ according to the settings of Emergency REC of Recording on the SETUP MENU. (Refer to page 98.) ● Connection for external recording changeover When the external switch is turned ON, the recording program changeover is effected for recording. The recording program can be set for EXT. with the Time Table...
Page 84
84 ● Connection for the Auto Adjust Time function • When Auto Adjust Time of System on the SETUP MENU is set to MASTER Time Adjust Output becomes available and the clock of this unit can be applied to other units. • When Auto Adjust Time of Systemon the SETUP MENU is set to SLAVE Time Adjust Input becomes available. When a signal output from other equipment is supplied to the time adjust I/O terminals between 00 minutes 00 seconds and 14 minutes 59 seconds every hour or between 45 minutes 00 seconds and...
Page 85
85 ● Connection with the Uninterruptible Power System (UPS) This is an example of connection with the uninterruptible power system (UPS) to be installed to protect from a power outage. When a signal is supplied to the outage detection I/O terminals from the uninterruptible power system (UPS), internal process- ing (stops recording safely) will be started to shut off the power supply for this unit. After completing the internal processing, a signal will be supplied from the outage processing end output...
Page 86
■ How to Use the Terminals of the ALARM Connector These terminals are used to connect the alarm devices, such as sensors, door switches, etc. The pin configurations of these terminals are as shown below. The connector used should be compatible with the pin configu- ration. Pin Configuration The pin array is different from other disk recorders. Make sure that the connection is correct referring to the following. 86 Pin No. q Pin No. Ch 1 alarm input Operation Event action will be performed according to...
Page 87
87 ● Alarm connection When a signal is supplied to the alarm input terminals of CH 1-16, recording and displaying of camera images will be per- formed according to the settings. When an alarm device such as a buzzer, a lamp, etc., is installed outside, connect them to the alarm output terminals (pin nos. 9 - 12, pin nos. 23 - 25) or to the alarm output terminals (pin nos. 1 - 9) of the ALARM/CONTROL terminal. Alarming devices Relay, etc. Alarming devices Install according to your needs.Relay, etc. (GND)...
Page 88
88 ■How to Use the SERIAL Connector This connector is compliant with the RS232C Standard, and is used to communicate with a connected PC. A connection example and the pin configuration of the SERIAL connector are as shown below. Important: •When using the SERIAL connector, it is necessary to perform the settings with RS232C Setup of Comm on the SETUP MENU for the communication functions. (Page 117) ●Pin Configuration ●Connection example 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109...
Page 89
89 SETUP To operate this unit, it is necessary to set each item of the SETUP MENU in advance. Perform the settings for each item of the SETUP MENU by displaying the SETUP MENU on monitor 2. Settings items are as below. ■Item list of the SETUP MENU Maintenance REC Rate Display the recording rate for each recording mode and image quality for each camera channel in list form. Disk Info Display hard disk information such as the available disk space on the built-in hard disk and the connected optional...
Page 90
90 Switcher Monitor1 Perform the settings for the image switching on monitor 1 such as the setting of the sequential display or the screen to be displayed at login on monitor 1. Monitor 2 Perform the settings for the image switching on monitor 2 such as the setting of the sequential display or the screen to be displayed at login on monitor 2. Display OSD Setup Perform the display settings such as the settings for the display position of the camera title and the time. Monitor1 Perform the display settings...