Page 81
81 Sending (DUMP)and loading (LOAD)edit data to an external component RS-232C The edit data stored in the EDL memory can be sent to and loaded from an external component using the EDL connector on the unit’s rear panel. Outputting data to a computer, for instance, and loading data from a computer enables a wide range of systems to be run and managed in the following ways.OData can be edited off-line by the unit, and the edit data can be used by an on-line system. OThe edit data can be stored on a hard...
Page 82
82 Sending (DUMP)and loading (LOAD)edit data to an external component Pin No.SignalPin No.Signal 1 DCD 1 DCD RD 2 RD TD 3 TD DTR 4 DTR GND 5 GND DSR 6 DSR RTS 7 RTS CTS 8 CTS =9 = 2 3 4 5 6 7 8 9 2Press the LOAD ([SHIFT] + [2]) button. The VTR1 button LED flashes to indicate that the data reception mode is now established. 3Data is now loaded from the computer or other external component. The number of the event being loaded appears on the event number display lamps. 4 OLoading is not possible if the...
Page 83
83 TITLE: PANASONIC EDITING CONTROLLER AG-A850 (AJ-LT95) EVENT REEL MODE TYPE RANS P-VTR IN P-VTR OUT R-VTR IN R-VTR OUT 0001 0001 ASMBL C 00:09:45:15 00:09:48:03 00:17:32.15 00:17:35.03 0002 0001 VA12 C 00:09:48:03 00:09:55:27 00:17:35.03 00:17:42.27 0003 AUDIO SPLIT REEL 0001 00:10:10:20 0003 0001 VA12 C 00:09:55:27 00:10:12:10 00:17:42.27 00:17:59:10 0004...
Page 84
84 Sending (DUMP)and loading (LOAD)edit data to an external component $CMX340 format OSome of the data is converted in this format so that it cannot be completely restored even when dumped data is loaded again. Event number:Deleted event numbers are packed and sent. During receiving, event numbers are ignored, and up to 200 events are received in sequence from the first event. Reel number:All reel numbers are received as “0001.” Editing mode:Assemble-edited data is converted into insert-edited data (V,...
Page 85
85 Superimposed screen Characters and symbols can be superimposed onto the output signals from the unit’s liquid crystal monitor or VIDEO MONITOR OUT connector. This superimpose function can be turned ON or OFF by pressing the DISP ([SHIFT] + [0]) button. The information to be superimposed and displayed can be selected using setup menu item No.002 (DISPLAY SEL). $TIME mode In this mode, the counter value is displayed on one line. TCR 12:34:56:21 $T&STA mode In this mode, the counter value and VTR’s...
Page 86
86 One of the following error messages is displayed when a problem has occurred in the unit. The VTR is set to the auto OFF mode (stop) or the power is forcibly turned off. Contact your dealer if the error display persists even when the power is turned off and turned back on again. Display tube Description dCondensation (dew) has formed. Leave the power on and wait until the error message is cleared. When OFF has been selected as the setup menu item No.170 (HUMID OPE) setting, “d” lights on the...
Page 87
87 Display tube Description E— 59Superimposed displayDRUM ROTA TOO SLOW VTR operation Auto OFF This appears when the cylinder motor’s rotation speed is abnormally low. E — 59DRUM ROTA TOO FASTAuto OFFThis appears when the cylinder motor’s rotation speed is abnormally high. E — 64 S REEL TOO FASTAuto OFFThis appears when the supply reel motor’s rotation speed is abnormally high. E — 67 T REEL TOO FASTAuto OFFThis appears when the take-up reel motor’s rotation speed is abnormally high. E — 69T REEL TORQUE...
Page 88
88 This unit is equipped with an auto head cleaning function which automatically reduces the amount of dirt on the video heads. However, in order to maximize the unit’s reliability, it is recommended that the video heads be cleaned as and when appropriate. For further details on how to actually clean the heads, consult one of our service companies or your dealer. Condensation Condensation forms according to the same principle by which droplets of water form on the window panes of heated rooms. It...
Page 89
89 Specifications [GENERAL] Supply voltage:DC 12 V Input current:12 A Ambient operating temperature: 41°F to 104°F (5°C to 40°C) Ambient operating humidity: 10% to 85% (no condensation) Weight: 28.38 lb (12.9 kg) Dimensions (Wa Ha D): 16 11/16˝a 4 3/4˝a 17 3/16˝ (424a 120a 435 mm) Recording format: DVCPRO 50 format/DVCPRO format selectable Video signals recorded: 525i/625i selectable (525i only with analog input signals) Audio signals recorded: DVCPRO 50: 48 kHz, 16 bits, 4 channels DVCPRO: 48 kHz, 16...
Page 90
90 [AUDIO] $Digital audio (same for VTR1, VTR2) Sampling frequency: 48 kHz Quantizing: 16 bits Frequency response: 20 Hz to 20 kHz ±1 dB (at reference level) Dynamic range: More than 85 dB (1 kHz, emphasis off, “A” weighted) Distortion: Under 0.1% (1 kHz, emphasis off, reference level) Crosstalk: Less than –80 dB (1 kHz, between 2 channels) Wow & flutter: Below measurable limits Headroom: 525i: 20 dB 625i: 18 dB Emphasis: T1 = 50 µs/T2 = 15 µs (on/off selectable) [ADJUSTMENTS] $Video output signals...