Home > Panasonic > Laptop > Panasonic Aj Lt95 Operating Instructions Manual

Panasonic Aj Lt95 Operating Instructions Manual

Here you can view all the pages of manual Panasonic Aj Lt95 Operating Instructions Manual. The Panasonic manuals for Laptop are available online for free. You can easily download all the documents as PDF.

Page 31

The underlining indicates the factory setting.30 MENU LOCK
0000
0001OFFONThis selects the setup menu lock mode.
0: The lock is released (enabling changes to be made).
1: The lock is engaged (prohibiting changes).
70 P.ON LOAD
0000
0001OFFONThis is for establishing the setting that changes the setup menu
settings to the user’s initial settings when the power is turned on.
0: The setup menu settings remain unchanged.
1: The setup menu settings are changed. 11 SYS SC 0000
0127
0255–127
0
128This is for...

Page 32

[ [[
The underlining indicates the factory setting.001 LOCAL ENA
0000
0001
DIS
ST&EJ
This selects the switches which can be operated on the control
panel when the CONTROL switch has been set to the REMOTE
position.
0: None of the switches or buttons can be operated.
1: Only the STOP (ALL STOP) and EJECT buttons can be
operated.
003 REMAIN SEL
0000
0001
OFF
ON
This selects whether the REMAIN (remaining tape time) display is
to be superimposed on the MONITOR OUT connectors and liquid
crystal monitor...

Page 33

The underlining indicates the factory setting.[[ 100 SEARCH ENA
0000
0001DIALKEYThis selects the direct search operation.
0: Direct search mode
1: Non-direct search mode (search dial operations are
acknowledged only in the STILL mode).
102 FF. REW MAX
0000
0001
0002x16
x32x50This selects the maximum speed of fast forwarding and rewinding.
0: 16 times normal speed
1: 32 times normal speed
2: 50 times normal speed 101 SHTL MAX
0000
0001
0002x8.4
x16x32This selects the maximum speed in the shuttle mode.
0:...

Page 34

OPERATION menu
The underlining indicates the factory setting.170 HUMID OPE
0000
0001OFFONThis selects whether the unit is to continue operating when
condensation has formed.
0: The unit does not operate.
1: It operates even when condensation has formed but no
guarantees are made for its operation.

Since tape damage or other problems may occur when “1: ON”
has been selected, the “0: OFF” setting should normally be used.
171 ALL STOP SEL
0000
0001STOPSTILLThis selects the unit’s mode to be established...

Page 35

270
The underlining indicates the factory setting.202 ID SEL
0000
0001OTHERDVCPROThis selects the ID information to be returned to the controller.
0: 20 25H (525i mode) is returned.
1: The DVCPRO’s own ID and F0 33H (525i mode) is returned.

This operation is not performed in the 625i mode.
207 STOP BIT
0000
000112This selects the RS-232C (EDL) stop bit.
0: 1 bit
1: 2 bits[ 205 BAUD RATE 0000
0001
0002
0003
00041200
2400
4800
960019200This selects the RS-232C (EDL) transfer (baud) rate.
[ [[
208 PARITY...

Page 36

The underlining indicates the factory setting.[[ 303 STD/NON-STD
0000
0001
0002AUTOSTD
N-STDThis selects the STD or NON-STD to match the composite input
signals.
0: The standard/non-standard signals are automatically identified
and processed.
1: The standard signals are processed.  (Forced STD)
2: The non-standard signals are processed.  (Forced NON-STD)

This operation is not performed in the 625i mode.
304 SERVO REF
0000
0001AUTOEXTThis selects the servo synchronizing signals.
0: During recording or...

Page 37

The underlining indicates the factory setting.[ 311 AUD EDIT IN
0000
0001
CUT
FADEThis selects how to join audio edit IN points.
0: Cut editing
1: Fade editing
313 AUTO ENTRY
0000
0001
0002
0003OFFREC1
REC2
ALLThis selects whether a previous edit OUT point is to be registered
automatically in the setting as the next edit IN point after
automatic editing.
0: No automatic setting
1: Automatic setting for VTR2 only
2: Automatic setting for VTR2 only (with compensation of –12
frames)
3: Automatic setting for...

Page 38

The underlining indicates the factory setting.370 BEEP
0000
0001
0002
0003OFF
ENTRY
ALL1ALL2This selects whether the confirmation tone is to be sounded.
0: The confirmation tone does not sound.
1: The confirmation tone is sounded when registering is performed
or when an error or warning has occurred.
2: The confirmation tone is sounded when registering is
performed, when an edit IN or OUT point is passed or when an
error or warning has occurred.
3: The confirmation tone is sounded when registering is...

Page 39

The underlining indicates the factory setting.379 1ST-E TITLE
This selects the title screen characters (3 lines a
20 characters)
which is to be superimposed onto the black burst signal during
1ST EDIT.
Characters:
ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789
,.:;?!/
’()+–±¢
=

OThis item takes effect when ON has been selected as the setup
menu item No.380 (1ST E-DISP) setting.
OThis operation is not performed in the 625i mode.
380 1ST-E DISP
0000
0001OFFONThis sets whether the title screen is to be superimposed...

Page 40

The underlining indicates the factory setting.400 STILL TIMER 0000
0001
0002
0003
0004
0005
0006
0007
0008
0.5s
5s
10s
20s
30s
40s
50s
1min
2minThis selects the time taken for the unit to be set to the tape
protection mode when it has been left standing in the STOP or
search STILL (JOG, VAR or SHTL) mode.
(Units: s = second, min = minute)
403 STOP PROTECT
0000
0001
STEP
HALF
This selects the tape protection mode operation when the unit has
been left standing in the STOP mode.
0: Step FWD 
1: Half...
Start reading Panasonic Aj Lt95 Operating Instructions Manual