E- EXTENSIONS E9- ATTENDANT (OPERATOR) ASSIGNMENT
Description
Use this option to assign an attendant to an extension.  This assignment is:
•The extension reached when the Intercom user dials 0 (refer to the Intercom feature)
•The attendant that can activate night mode Toll Restriction for the extension (if applicable)1
•The DSS Console owner (for DSS Consoles only)
When programming Tenant Service, assign the same operator to each extension in the tenant group.
For Automatic Ringdown, enter the ringdown...

Page 382

E9- RING DOWN
Description
Use this option to enable (Y) or disable (N) Automatic Ringdown for ASI/OPX and ESL extensions.  You
should only do this if you have entered an Automatic Ringdown destination in E9- Attendant (Operator) Assign-
ment.
This option applies only to ASI/OPX and ESL extensions.
Conditions
None
Default Value
Automatic Ringdown disabled (N).
Feature Reference
Automatic Ringdown
Instructions
To enter data on the PRF:
1. For each OPX/ASI and ESL extension on Table 3, enter N (to disable)...

Page 383

EA- UCD GROUP MASTER EXTENSION NUMBER
Description
Use this option to assign an ACD or UCD master extension number.
When programming an ACD group, assign the master extension number to:
•Each member agent
•The supervisor extension
•The ACD group master extension
When programming a UCD group (for Extension Hunting or Voice Mail applications), assign the master exten-
sion number to:
•Each group member
•The master extension number
This option appears for DISA trunks.  For DISA, use this option to assign the...

Page 384

EB- PERSONAL SPEED DIAL BLOCK
Description
Use this option to assign a Speed Dial block to an extension for Extension Speed Dial.  You can assign only one
block to an extension, but more than one extension can share the same block. This lets the users share Extension
Speed Dial numbers.  Do not, however, assign an extension one of the System Speed Dial blocks.
When assigning blocks, you normally assign the highest available block to the lowest extension number.  Con-
tinue assigning blocks in decreasing...

Page 385

EC- EXTENSION CALL PICKUP GROUP
Description
Use this option to assign an extension to a Call Pickup Group (01-23).  To assign a trunk to a Call Pickup
Group, refer to E- Trunks, EC- Trunk Call Pickup Group.
For DISA, refer to E- Trunks, EC- Trunk Call Pickup Group.
Conditions 
This option does not apply to DSS Consoles or Modem Pooling ports.
Default Value
Extensions not assigned to Call Pickup Groups (00).
Feature Reference
Group Call Pickup
Silent Monitor
Instructions
To enter data on the PRF:
1. Enter...

Page 386

EC- PRIVACY RELEASE GROUP
Description
Use this option to assign a keyset to a Privacy Release Group (01-99).
Conditions 
None
Default Value
Keyset not assigned to a Privacy Release Group (00).
Feature Reference
Privacy Release Groups
Telemarketing Dial
Instructions
To enter data on the PRF:
1. Enter the Privacy Release Group number for each extension on Table 3. To assign no group number, en-
ter 00.
To enter data at the programming terminal:
1. After programming Call Pickup Group, you see:  PRVCY RLS...

Page 387

ED- TRUNK CONTROL, RING CONTROL
Description
Use ED- Ring Control to set ringing options for each trunk at each keyset.  The options are:
•R – Immediate Ringing
Phone starts ringing as soon as line key begins to flash
•D – Delayed Ringing
Phone starts ringing after the delayed ring interval (the line key flashes immediately).  Refer to
QT- System Timers, Delayed Ring Interval when setting the delayed ring interval.
•L – Lamp Only (no ringing)
Phone never rings (line key only flashes)
•N – Night Ring
Phone...

Page 388

Instructions
To enter data on the PRF:
1. For each extension, enter each trunk’s Ring Control option on Table 5.
To enter data at the programming terminal:
1. Type ED.  You see:  EXT 300
2. Press RETURN to program extension 300.
OR
Enter another extension number and press RETURN.  In either case, you see: RING CONTROL - -
COPY?
The Copy option lets you copy the key programming from another extension.
3.
-To copy another extension’s keys, enter Y and the extension number.
After you enter the extension...

Page 389

ED- TRUNK CONTROL, ACCESS CONTROL
Description
Use ED- Access Control to set the access options for each trunk at each extension.  If allowed in other program-
ming, an extension can place and answer calls on trunks to which it has access.
Keep the following features in mind when programming Access Control:
•Call Parking
An extension can only pick up parked calls on trunks to which it has access.
•Central Office Calls, Answering and Placing
Assign access for the trunks the extension should be able to...

Page 390

Instructions
To enter data on the PRF:
1. For each extension, enter Y on Table 5 for each trunk that should have access enabled.  Enter N for each
trunk that should not have access.
To enter data at the programming terminal:
1. After programming ED- Ring Control for a trunk, you see:  ACCESS CONTROL - COPY?
The Copy option lets you copy the key programming from another extension.
2.
-To copy another extension’s keys, enter Y and the extension number.
After you enter the extension number, you skip to ED-...