    							NDA-24233 Issue 2Page 3-45
    VisuaLink 128/384 Engineering Guide Console Command List
    3.15  Maintenance and Other Command
    ISPR Setting Parameter Initialization 15-1
    CRAM Clearing Backup Memory 15-2
    RRST System Reset Request 15-3
    Description: Initializes all VisuaLink values to factory default.
    Command Format: ISPR
    Response: Normal Response  OK
    Error Response:  ERR01
    Description: Initializes registered data.
    Command Format: CRAM p1
    p1: T :  abbreviated speed dial registration
    S :  camera preset registration
    Note: 
     If not specified, both registered contents are initialized.
    Response: Normal Response  OK
    Error Response:  ERR01
    Description: Resets the VisuaLink. 
    Command Format: RRST
    Response: Normal Response  OK
    Error Response:  ERR01 
    						
    							Page 3-46NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    WCLK Setting System Clock 15-4
    RCLK Checking System Clock Setting 15-5
    Description: Sets the VisuaLink built-in system clock, date and time.
    Command Format: WCLK p1-p2-p3 p4:p5:p6 (p7)
    p1: yyyy :  year
    p2: 01-12 :  month
    p3: 01-31 :  date 
    p4: 01-24 :  hour
    p5: 00-59 :  minute
    p6: 00-59 :  second
    p7: xxx  :  day of the week
    (MON/ TUE/ WED/ THU/ FRI/ SAT/ SUN)
    Response: Normal Response  OK
    Error Response:  ERR01
    Description: Reads the VisuaLink built-in system clock, date and time.
    Command Format: RCLK 
    Response: Normal Response p1-p2-p3 p4:p5:p6 (p7) OK
    p1: yyyy :  year
    p2: 01-12 :  month
    p3: 01-31 :  date 
    p4: 01-24 :  hour
    p5: 00-59 :  minute
    p6: 00-59 :  second
    p7: xxx  :  day of the week
    (MON/ TUE/ WED/ THU/ FRI/ SAT/ SUN)
    Error Response:  ERR01 
    						
    							NDA-24233 Issue 2Page 3-47
    VisuaLink 128/384 Engineering Guide Console Command List
    3.16  Mutli-point Conference Status Command
    RMNA Read Multi-point Conference Participating Location Name 16-1
    Description: Acquires location name of all location participating locations in multi-
    point conference.
    Command Format: RMNA p1
    p1: 1-255 : conference room number (can be specified in 
    multiple)
    Response: Normal Response p1 p2 p3 OK
    p1: 1-999 : conference room number
    p2: xxxxxxxx  :  location name in alphabet 
    p3: XXXXXXXX  : location name in Japanese character
    Error Response:  ERR01
    ERR24 
    						
    							Page 3-48NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    RMST Read Multi-point Conference Operation Status (NEC Specific) 16-2
    Description: Acquires a status of a multi-point conference status when in activated for 
    NEC specific multi-point conference.
    Command Format: RMST p1 p2 p3 p4 p5 p6 ............ p18
    p1: 1-14  :  local site conference number
    p2: 0000-FFFF  :  conference participating status 1: participate 
    0: not participate
    p3: 0000-FFFF  :  terminal connection status 1: connect 
    0: not connected
    p4: 0000-FFFF  :  audio switch status 1: switch 0: not switch
    p5: 0000 : fixed
    p6 0000 : fixed
    p7: 1-14  :  operator conference room number 00: no 
    operator
    p8: 1-14  :  conference room number of the originator of 
    multiple address transmission
    p9: 1-14  :  conference room number of a location 
    receiving multiple address transmission.
    p10: 1-14  :  conference room number of the originator of a 
    transmission at a specify video reception.  It is 
    not a specific video reception if it is 00.
    p11: 0 : fixed
    p12: 0 : fixed
    p13: 0 : fixed
    p14: 0 : fixed
    p15: 0 : fixed
    p16: 0 : fixed
    p17: 1111 : fixed
    p18: 0-1  :  local office in transmission  0: not transmitting 
    1: transmitting
    Note 1:
    When p1 = 0, a local site withdraw from a multi-point 
    conference.
    Note 2:
    Bit assignment of 0000-FFFF is as 
    follows:
    XX
    14131211109876543 21
    Master Only
    Slave                                                Master 
    						
    							NDA-24233 Issue 2Page 3-49
    VisuaLink 128/384 Engineering Guide Console Command List
    RMPS Read Multi-point Conference Operation Status 16-3
    RMMD Read Multi-point Conference Mode Status 16-4
    Description: Acquires the multi-point conference status.
    Command Format: RMPS
    Response: Normal Response p1 p2 p3 p4 p5 p6 OK
    p1: 1-255  : local site conference room number
    p2: 0/1  :  status of acquisition of a right to operate in a local site 
    1: acquired 0: released 
    p3: 1-255  :  location number of a video being received
    p4: 0/1  :  local site video transmitting status 0: OFF 1: ON 
    p5: 1-255  :  a number of multi-point conference participants
    p6: 0/1  :  screen composite capability 0: none 1: yes 
    Error Response:  ERR01
    Description: Acquires the multi-point conference mode status.
    Command Format: RMMD
    Response: Normal Response p1 OK
    p1: 1 : audio switch
    2 :  local site video transmission
    3 : chairman control
    4 : selective receive
    5 :  a status of multiple address transmission by operator
    Error Response:ERR01 
    						
    							Page 3-50NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.17  Model Identification Command
    RMES Read Model Identification 17-1
    Description: Read model identification
    Command Format: RMES
    Response: Normal Response p1 p2 OK
    p1: TC2000_EC : VL128
    TC2000_6B : VL384
    p2: F/W version: ex. V01.01.01
    Error Response:ERR01 
    						
    							NDA-24233 Issue 2Page 3-51
    VisuaLink 128/384 Engineering Guide Console Command List
    3.18  Audio Training Command
    ECTS Audio Training Command 18-1
    Description: Initiate audio training.  White noise is generated while 7 seconds.
    Command Format: ECTS
    Response: Normal Response OK
    Error Response:ERR01 
    						
    							Page 3-52NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.19  ISDN Control Command
    NCRN Requesting Connection 19-1
    Description: Placing a BRI ISDN call.  A call can be requested by either directly 
    specifying a remote number or using an speed dial number.  If using an 
    speed dial number, it must be registered in advance with MDST command.
    Command Format: NCRN  p1 p2 p3
    p1: #xx  :  speed dial call (xx : speed dial number)
    0-9  :  dial number (within 20-digit)
       Sub address (within 8-digit)
    *  :  address/ sub address
    **  :  ch1/ ch2 separating code
    R : redial
    p2: B : 64 kbps
    2B :  2x64 kbps
    3B : 192 kbps
    4B : 256 kbps
    5B : 320 kbps
    6B : 384 kbps
    TEL :  telephone
    p3: 64  :  P x 64 k network
    56 :  P x 56 k network
    Note 1:
    With p1: speed dial, p2 and p3 are omitted.
    Note 2:
    When p3: is omitted, “64” is set.
    Note 3:
    When p3 = TEL, p4 is omitted.
    Response: Normal Response OK
    Error Response:  ERR01
    ERR05
    ERR33
    ERR34
    ERR35
    ERR41
    ERR43
    ERR44
    ERR45
    ERR47
    ERR48
    ERR86
    ERR87
    Note:
      If VL128, setting 3B - 6B in p1 results in error. 
    						
    							NDA-24233 Issue 2Page 3-53
    VisuaLink 128/384 Engineering Guide Console Command List
    NDSC Requesting Disconnection 19-2
    NCIC Incoming Call Permit/Reject 19-3
    Description: A disconnect in an BRI ISDN call.  This command is used to execute a 
    disconnection request and ending communication.
    Command Format: NDSC
    Response: Normal Response:  OK
    Error Response:  ERR01
    ERR41
    ERR46
    ERR48
    ERR87
    Description: Permits or rejects incoming call on the BRI ISDN live.  When a manual 
    incoming call mode is selected with a SINC command, NCIC command 
    permits or rejects an incoming call for NINC indication.
    Command Format: NCIC p1
    p1: YES : permit
    NO : reject
    Response: Normal Response:  OK
    Error Response:  ERR01
    ERR05
    ERR41
    ERR42
    ERR87 
    						
    							Page 3-54NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    NSTQ Communication Status Inquiry 19-4
    Description: Gives a status on the ISDN communication.
    Command Format: NSTQ 
    Response: Normal Response p1 p2 p3  p4 p5 p6 p7 OK
    p1: B : communication speed B
    2B :  communication speed 2B
    3B : communication speed 3B
    4B : communication speed 4B
    5B : communication speed 5B
    6B : communication speed 6B
    TEL :  communication speed TEL
    p2: xx  :  ch1 communication status (see below)    
    p3: xx  :  ch2 communication status (see below)  
    p4: xx  :  ch3 communication status (see below)  
    p5: xx  :  ch4 communication status (see below)  
    p6: xx  :  ch5 communication status (see below)  
    p7: xx  :  ch6 communication status (see below)  
    Communication Status xx =   01:  no communications
    02: dialing
    03: waiting to connect
    04: calling
    05:  checking a response
    06: communicating
    07: disconnecting
    Error Response:  ERR01
    ERR05
    ERR41
    ERR87
    Note:
      If VL128, p4 ~ p7 are not reported. 
    						