    VisuaLink 128/384 Engineering Guide Console Command List
    RCST Read Participating Conference Status 7-5
    Description: This reads conference participating status.
    Command Format: RCST
    Response: Normal Response: p1 p2 OK
    p1: PP  :  point to point connection 
       MP  :  multi-point connection 
    p2: H243 :  multi-point conference based on ITU-T H243 
    MLP  :  NEC specific multi-point conference 
    Note: 
     When p1 = PP, p2 is omitted.
    Error Response:  ERR01  
    						
    							Page 3-36NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.8  Alarm Related Command
    CALM Read Alarm Status (1 of 2) 8-1
    Description: Acquires alarm status.  This is used to check the information of a generated 
    alarm and the loopback status.
    Command Format: CALM
    Response: Normal Response: p1 p2 p3 p4 p5 p6 OK
    p1: 00-FF :  CPU/ VIDEO alarm
    p2: 00-FF :  LINE alarm
    p3: 00-FF :  H221 alarm
    p4: 00-FF :  Bonding alarm
    p5: 00-FF :  TEST status
    p6: 00-FF :  TEST status 2
    p1: CPU/VIDEO alarm
    D0:  CPU alarm   0:  normal  1:  abnormal
    D1:  FAN alarm   0:  normal  1:  abnormal
    D2-3: Unused 0: fixed
    D4:  VIDEO alarm 0:  normal  1:  input cut
    D5-7:  Unused   0: fixed
    p2: LINE alarm
    D0-3: Unused   0: fixed
    D4:  Line 1 SYNC alarm 0:  normal  1:  abnormal
    D5: Line 2 SYNC alarm 0:  normal  1:  abnormal
    D6: Line 3 SYNC alarm 0:  normal  1:  abnormal
    D7:  Unused   0: fixed
    p3: H221 alarm
    D0:  REC alarm   0:  normal  1:  abnormal
    D1:  CRC alarm   0:  normal  1:  abnormal
    D2-7:  Unused   0: fixed
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0 
    						
    							NDA-24233 Issue 2Page 3-37
    VisuaLink 128/384 Engineering Guide Console Command List
    CALM Read Alarm Status (2 of 2) 8-1
    Response
    p4: Bonding alarm
    D0: Bonding frame loss  0: normal 1: abnormal
    D1: Bonding speed negotiation fail 0: normal 1: abnormal
    D2: Network type negotiation fail 0: normal 1: abnormal
    D3: Dialing number negotiation fail 0: normal 1: abnormal
    D4: Additional channel connection fail 0: normal 1: abnormal
    D5-7:Unused 0: fixed
    p5: TEST status
    D0-3:  Unused   0: fixed
    D4-5:  Local Loopback   00:  Off
    01: Video
    10: Audio
    11: LINE
    D6-7:  Unused   0: fixed
    p6: TEST status 2
    D0-1:  Video mute   0: OFF 1: ON
    D2-3: Unused 0: Fixed
    D4: Audio mute 0: OFF 1: ON
    D5: Line 1 loopback 0: OFF 1: ON
    D6: Line 2 loopback 0: OFF 1: ON
    D7: Line 3 loopback 0: OFF 1: ON
    Error Response:  ERR01
    ERR07
    ERR87
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0 
    						
    							Page 3-38NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.9  History Reading Command
    RLAM Read Communication/Alarm History 9-1
    Description: Acquires communication history and alarm history.
    Command Format: RLAM  p1 p2 p3
    p1: L : communication history
    A  :  alarm history
    p2: yyyy/mm/dd/hh:mm :  starting date
    p3: yyyy/mm/dd/hh:mm :  ending date
    yyyy: year
    mm: month
    dd: date
    hh: hour
    mm: minute
    Note: 
     p2 and p3 can be omitted.  If so, all the histories are output.
    Response: Normal Response: p1 p2 OK
    p1: [yyyy/mm/dd hh:mm]  :  date
    p2: xxxxxxxxxx : contents of history (xx is moved to 
    a new line after 50 byte) 
    Error Response:  ERR01
    Example 1:
     Communication history
    RLAM L
    [1997/10/20/09:46] NALT
    [1997/10/20/09:47] NONL 2B
    [1997/10/20/09:57] NDCI 00:10:00 ¥110#016#016
    OK
    Example 2:
    Alarm history
    RLAM A
    [1997/10/20/09:35] RALM 10 00 00 00 00 00
    [1997/10/20/09:37] RLAM 00 00 01 00 00 00
    [1997/10/20/09:38] RLAM 00 00 00 00 00 00
    OK 
    						
    							NDA-24233 Issue 2Page 3-39
    VisuaLink 128/384 Engineering Guide Console Command List
    3.10  Registering Local Location Name Command
    MRNS Registering Local Site Name 10-1
    Description: Registers a local site location name.
    Command Format: MRNS p1 p2
    p1: xxxxxxxx :  alphabet location name (within 16 characters)
    p2: XXXXXXXX :  character location name (within 16 characters)
    Note 1:
      When p1 is omitted, a location name is deleted.
    Note 2:
      When p1 is omitted, p2 is omitted.
    Response: Normal Response  : when parameter is specified OK
    : when parameter is omitted p1 p2 OK
    p1: xxxxxxxx :  alphabet location name (within 16 characters)
    p2: XXXXXXXX :  character location name (within 16 characters)
    Error Response:  ERR01 
    						
    							Page 3-40NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.11  Serial Port Control Command
    SSIO Setting Serial Port 11-1
    RSIO Checking Serial Port Setting 11-2
    Description: VisuaLink is equipped with two serial ports, and four possible settings:
    T120 data conference
    Camera control
    External console control
    User data (Not compliant to T.120)
    Command Format: SSIO   p1
    p1: 1 Serial 1 = T120  Serial 2 = Console
    2  Serial 1 = Camera  Serial 2 = Console
    3  Serial 1 = T120  Serial 2 = Camera
    4  Serial 1 = Console  Serial 2 = Camera
    5  Serial 1 = User data  Serial 2 = Console
    6  Serial 1 = User data  Serial 2 = Camera
    Response: Normal Response OK
    Error Response:ERR01
    Description: Checks the current serial port configuration.
    Command Format: RSIO
    Response: Normal Response p1 OK
    p1: 1  Serial 1 = T120   Serial 2 = Console
    2  Serial 1 = Camera  Serial 2 = Console
    3  Serial 1 = T120   Serial 2 = Camera
    4  Serial 1 = Console  Serial 2 = Camera
    5  Serial 1 = User data  Serial 2 = Console
    6  Serial 1 = User data  Serial 2 = Camera
    Error Response:ERR01 
    						
    							NDA-24233 Issue 2Page 3-41
    VisuaLink 128/384 Engineering Guide Console Command List
    3.12  Acquiring Version Command
    RVER Requesting Software Version 12-1
    Description: Acquires the VisuaLink software version.
    Command Format: RVER
    Response: Normal Response:p1 p2  OK
    p1: xxxxxxxx : F/W version
    p2: xxxxxxxxx : DSP version
    Error Response:  ERR01
    ERR07
    ERR87 
    						
    							Page 3-42NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.13  Maintenance Command
    SLLB Setting Local Loopback 13-1
    RLLB Checking Local Loopback Setting 13-2
    Description: Sets local loopback process.
    VisuaLink is equipped with a loopback test point inside a terminal for 
    autonomous diagnosis as a maintenance feature.  Loopback points are as 
    follows:
    AUDIO: analog audio section loopback
    VIDEO: analog video section loopback
    LINE: line interface section loopback
    Command Format: SLLB p1
    p1: Off : release
    AUDIO : audio loopback
    VIDEO :  video loopback
    LINE : line loopback
    Response: Normal Response  OK
    Error Response:ERR01
    ERR07
    ERR13
    ERR14
    ERR38
    ERR45
    ERR47
    ERR87
    Description: Checks the current loopback status.
    Command Format: RLLB
    Response: Normal Response: p1 OK
    p1: Off : release
    AUDIO: audio loopback
    VIDEO: video loopback
    LINE: line loopback
    Error Response:ERR01
    ERR87 
    						
    							NDA-24233 Issue 2  Page 3-43
    V isuaLin k 12 8/38 4 En gineerin g Guide   Conso le  Co mman d List
    3.14  Re port Response Cont rol Command 
    						
    							Page 3-44   NDA-24233 Issue 2
    Console Com mand  List   Vis uaLink  128/ 38 4  Engi neerin g Guide
    I243   H.243 Report Control   14-3 
    						