NEC Visualink 128/384 Engineering Guide
Have a look at the manual NEC Visualink 128/384 Engineering Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NDA-24233 Issue 2Page 4-1 VisuaLink 128/384 Engineering Guide Error Response Table 4: Error Response Table If a command input from console is not understandable or has a different configuration, an error response is transmitted to the console. Error responses are shown in the following table. Table 4-1: Error Response Table (1/2) ERR Number Contents Countermeasures ERR01 Syntax error. Check the format of a command ERR05 It is a command that cannot be accepted by the current system.Check current system settings ERR06 It is during an initial setting. Try again ERR07 Time out Try again ERR09 It is a command that cannot be executed in the current mode.Check current system settings ERR10 A camera is not connected. Check current system settings ERR11 This is not a preset camera. Check current system settings ERR12 The displayed screen is not a received video, so a remote camera control cannot be performed.Check current system settings ERR16 NEC specific features cannot be performed.Check current system settings ERR17 The remote terminal has no capability to perform this command.It is impossible in the current configuration ERR18 Cannot be controlled for it is set for a pass-through mode.VL is in remote maintenance. ERR20 MLP port has not yet been established. Check communication status and execute command again. ERR21 Error in data speed setting combination. Check current system settings ERR22 The local site is not participating in the conference room.Check communication status ERR23 A specified conference room is not participating in a multi-point conference.Check communication status and execute command. ERR24 Multi-point command is either invalid or overlapping.Check communication status and execute command. ERR26 VL is not in multi-point conference. Check communication status and execute command. ERR32 It cannot be set in the current network. Check communication status and execute command. ERR37 The remote terminal cannot be recognized as a NEC model.Check communication status and execute command. ERR38 Local loopback cannot be done since it is processing a remote loopback.Execute a command after release of the remote loopback. ERR 40 It is in a telephone communication mode.Command to execute is impossible. ERR41 Network in use is not an ISDN line. Check current system settings ERR42 No incoming call Check communication status and execute command. ERR43 Currently originating a call. Check communication status and execute command. ERR44 Incoming call Check communication status and execute command. ERR45 On line. Check communication status and execute command again.
Page 4-2NDA-24233 Issue 2 Error Response Table VisuaLink 128/384 Engineering Guide Figure 4-1: Error Response Table (2/2) ERR Number Contents Countermeasures ERR46 Off line. Check communication status and execute command again. ERR47 Currently processing. Try again ERR48 Disconnecting. Check communication status and execute command again. ERR49 Specified delay time is not in decimal. Check the format of command. ERR50 Specified delay time is not in 10 ms step.Check the format of command. ERR51 It cannot be executed since a command generator is in execution.Try again ERR85 Execution is impossible. Re-start VL unit ERR86 File overflow of the command generator Try again ERR87 CODEC processing. Try again ERR88 Exchanging capabilities. Try again ERR90 Command not currently supported. Command to execute is impossible.
NDA-24233 Issue 2Page 5-1 VisuaLink 128/384 Engineering Guide Factors of Disconnections 5: List of Factors for Disconnection in Table Location of Factors for Disconnection LU: Local User LN: Local Network TN: Transit Network RU: Remote User RN: Remote Network Number Message Factors for Disconnection Countermeasure (Example) Location # 1 Unassigned numberCall cannot come in since it is currently a unassigned number. Check the remote number. LN/RU # 2 No route to specified transit networkSpecified transit network cannot be recognized.Check the remote number. TN/LN # 3 No route to destinationNo route to remote site. Check the remote number. LN/RU # 6 Cancel unacceptableA channel cannot be accepted in a network.After a while, retry connection. LN # 7 Remote is busy Connected channel is used. After a while, retry connection. LN # 16 Normal is busy A restoration of a disconnection of a call is requested.Try again RU # 17 User busy It is currently in a communication with others.After a while, make a connection again.RU/RN # 18 No user response No response Check status of remote unit. RN # 19 User alerting, no answerNo response after a call message is received.Check status of remote unit. RN # 21 Call rejected Communication is rejected. Check status of remote unit. RU # 22 Number changedRemote terminal number has been changed.Check remote number, make another connection.LN/RU # 26 Non-selected user clearingNo incoming bell After a while, retry. LN # 27 Destination out of orderRemote terminal is OFF Check status of remote unit. RU # 28 Invalid number format (address incomplete)Invalid format or incomplete number.Check remote number and retry.LN/RU/ RN # 29 Facility rejected Requested facility is not allowed. Check remote number. LN/RU/ RN # 30 Response to STATus ENquiryInquiry for status was received. Check remote number and retry.LU/LN # 31 Normal, unspecifiedNormal status was reported. After a while, retry. RN # 34 Circuit/channel congestionNo line or channel is available. Check communication status. LN/RN/TN # 38 Line failure Network is not functioning normally. After a while, retry. LU/LN/RU # 41 Temporary failure Network is temporarily not available. After a while, retry. RN # 42 Switching equipment congestionSwitch is busy. After a while, retry. # 43 Access information discardedRequested information element cannot be transmitted to a remote.After a while, retry. # 44 Requested channel not availableReported line or channel cannot be provided.After a while, retry. LN/RU # 47 Resource unavailable, unspecifiedReport status that other network is busy.Contact a retailer or a service center. # 49 This service is currently not availableQOS cannot be provided. RU/RN/ LN
Page 5-2NDA-24233 Issue 2 Factors of Disconnections Number Message Factors for Disconnection Countermeasure (Example) Location # 50 Requested facility not subscribedProcedure for a requested facility is not taken.Contact a retailer or a service center.LN # 57 Bearer capability not authorizedUnauthorized transmission capability was requested.Contact a retailer or a service center.LN # 58 Bearer capability not presently availableTransmission capability currently not available for use.Contact a retailer or a service center.LN # 63 Service or option not availableReport that other services cannot be used.Contact a retailer or a service center.LN # 65 Bearer capability not implementedRequested transmission capability is not supported.Contact a retailer or a service center. # 66 This service is currently not availableRequested channel class is not supported.Contact a retailer or a service center.RU/RN/ LN # 69 Requested facility not implementedRequested additional service is not supported.Contact a retailer or a service center. # 70 A connection could not be madeLimited digital transmission capability among requested transmission capabilities is supported.Contact a retailer or a service center.LU/LN # 79 Service or option not implementedReport that a service cannot be provided.After checking a remote number, retry. # 81 Invalid call reference valueDifferent dial number from the currently used number is used.After checking a remote number, retry.LN # 82 Please dial again Invalid channel number is used. After checking a remote number, retry.LN # 83 A connection could not be madeA different number from the interrupt call discriminating number is used.After checking a remote number, retry.LN # 84 A connection could not be madeThe interrupt call discriminating number currently in use is used.After checking a remote number, retry.LN # 85 A connection could not be madeCall discriminating number is not used.After checking a remote number, retry.RU # 86 A connection could not be madeInterrupt call has already been disconnected.After checking a remote number, retry.TN/ LN # 88 Incompatible destinationAttribute of a terminal unit does not match.After checking a remote number, retry.LN # 91 No available line for useFormat of a transit network is not normal.After checking a remote number, retry. # 95 A connection could not be madeReport of other invalid messages. # 96 Mandatory information element is missingRequired information element is in short.Contact a retailer or a service center.LU/ LN # 97 A connection could not be madeUndefined or not-provided message is received.Contact a retailer or a service center.LU/ LN # 98 A connection could not be madeMessage mismatch. Contact a retailer or a service center.LU/ LN # 99 A connection could not be madeInformation element is undefined. Contact a retailer or a service center.LU/ LN # 100 Invalid information element contentsThe contents of information element is invalid.Contact a retailer or a service center.LU/LN # 101 Message not compatible with call stateReceived message and a call status mismatch.After checking a remote number, retry.LU/LN # 102 Recovery on timer expiryRestoration due to an expiration of timer.After checking a remote number, retry.LU/LN
NDA-24233 Issue 2Page 5-3 VisuaLink 128/384 Engineering Guide Factors of Disconnections Number Message Factors for Disconnection Countermeasure (Example) Location # 111 Protocol error, unspecifiedReport of other protocol error. After checking a remote number, retry.RN # 127 Interworking, unspecifiedInter-work occurrence in a network that cannot display a reason for operation.After checking a remote number, retry. # 901 No response from the remote terminalAutomatic Dial timed out Check a remote unit status. # 903 Network failure Line (layer 1) failure (Physical connection error).Contact a retailer or a service center. # 904 Network failure Line (layer 2) failure (Electric interface error)Contact a retailer or a service center. # 905 Network failure or wrong contactTEI error Contact a retailer or a service center. # 906 Network failure Layer 3 (Appreciation layer) calling timed outContact a retailer or a service center. # 907 Disconnected by initializationNot used # 908 Disconnected by initializationNot used Contact a retailer or a service center. # 909 Disconnected by initializationNot used Contact a retailer or a service center. # 912 Disconnected by initializationMessage inconsistent with the current condition is received.After a while, retry. # 913 Disconnected by initializationConnect and disconnect during a re- start response waiting.After a while, retry. # 914 Network failure Lower layer in failure # 915 network failure Lower layer in failure # 916 The provisioned communication time expiredCalling condition is NG # 917 A connection could not be madeLayer 3 initialization not completed # 918 A connection could not be madeLayer 3 initialization missed # 919 A connection could not be madeCES pointing error # 980 Disconnected VCP (Video chip hang-up) After a while, retry.
Page 5-4NDA-24233 Issue 2 Factors of Disconnections This page is for your notes.
NDA-24233 Issue 2Page A-1 VisuaLink 128/384 Engineering Guide Appendix A Appendix A: Pin-out Specification Pin-out specifications for all the VL 128/384 connectors. SERIAL 1 PORT Note: The signal direction shown is seen from the VisuaLink 128 (DTE). SERIAL 2 PORT Note: The signal direction shown is seen from the VisuaLink 128 (DTE). Headset MIC Connection (1 - 3) NO Symbol Direction Function 1 RS OUT Request to Send 2 CS IN Clear to Send 3 SD OUT Send Data 4 GND - Ground 5 RD IN Receive Data 6- - 7 ER OUT Data Terminal Ready 8 DR IN Data set Ready NO Symbol Direction Function 1 RS OUT Request to Send 2 CS IN Clear to Send 3 SD OUT Send Data 4 GND - Ground 5 RD IN Receive Data 6+5V OUT 7 ER OUT Data Terminal Ready 8 DR IN Data set Ready Name Function TIP Input from microphone RING Output to ear piece SLEEVE Ground Name Function Polarity TIP Input from microphone + RING Output to ear piece - SLEEVE Ground 8 PIN MIN DIN FEMALE 8 PIN MIN DIN FEMALE RING TIP SLEEVE HEADSET JACK RING TIP SLEEVE MIC JACK
Page A-2NDA-24233 Issue 2 Appendix A VisuaLink 128/384 Engineering Guide S/T Line (ISDN Connection) Note 1: The signal direction shown is seen from the VisuaLink 128 (DTE). Note 2: Pins 1, 2, 7, and 8 are not used. Telephone Connection S-Video Socket Input/Output PIN # Symbol Function Polarity 1a 2b 3 c Transmit Tip + 4dReceive Tip + 5 e Receive Ring - 6fTransmit Ring - 7g 8h NO Symbol Function 1 2 3 L2 2W RING PIN 4 L1 2W TIP PIN 5 6 NO PIN NAME A1 AG (Analog GND) A2 AG (Analog GND) A3 Y Signal IN A4 O Signal IN B1 AG (Analog GND) B2 AG (Analog GND) B3 Y Signal OUT B4 O Signal OUT RJ45 FEMALE 8 7 6 5 4 3 2 1 RJ11 FEMALE 6 5 4 3 2 1 O U T I N B4 B3 SOCKET B (Output) VIDEO2 B2 B1 A3A4 A1A2 SOCKET A (Input)
NDA-24233 Issue 2Page B-1 VisuaLink 128/384 Engineering Guide Appendix B Appendix B: Line Speed Specifications X : cannot set D: can set but video is not transmitting : snapshot not available X : cannot set1B (64kbps) Line Speed Audio AlgorithmsG.711 m-Law PCMG.722 SB-ADPCMG.728 LD-CELPMute Audio Byte Rate (kbps)56.048.016.00.0 MLP OFF6.4 14.4 46.462.4 MLP 4kbps2.4 10.4 42.458.4 MLP 6.4kbpsD8.0 40.056.0 MLP 14.4 kbpsXD32.0 48.0 MLP 24kbpsXX22.4 38.4 2B (128kbps) Line Speed Audio AlgorithmsG.711 m-Law PCMG.722 SB-ADPCMG.728 LD-CELPMute Audio Byte Rate (kbps)56.048.016.00.0 MLP OFF68.876.8108.8124.8 MLP 4kbps64.872.4104.8120.8 MLP 6.4kbps62.470.4102.4118.4 MLP 14.4 kbpsX62.494.4110.4 MLP 24kbpsXX84.8100.8
Page B-2NDA-24233 Issue 2 Appendix B VisuaLink 128/384 Engineering Guide This page is for your notes.