    							NDA-24233 Issue 2Page 4-1
    VisuaLink 128/384 Engineering Guide Error Response Table
    4:  Error Response Table
    If a command input from console is not understandable or has a different configuration, an error response is 
    transmitted to the console.  Error responses are shown in the following table.
    Table 4-1: Error Response Table (1/2)
    ERR Number Contents Countermeasures
    ERR01 Syntax error. Check the format of a command 
    ERR05 It is a command that cannot be 
    accepted by the current system.Check current system settings
    ERR06 It is during an initial setting. Try again
    ERR07 Time out Try again
    ERR09 It is a command that cannot be 
    executed in the current mode.Check current system settings
    ERR10 A camera is not connected. Check current system settings
    ERR11 This is not a preset camera. Check current system settings
    ERR12 The displayed screen is not a received 
    video, so a remote camera control 
    cannot be performed.Check current system settings
    ERR16 NEC specific features cannot be 
    performed.Check current system settings
    ERR17 The remote terminal has no capability 
    to perform this command.It is impossible in the current configuration
    ERR18 Cannot be controlled for it is set for a 
    pass-through mode.VL is in remote maintenance.
    ERR20 MLP port has not yet been established. Check communication status and execute 
    command again.
    ERR21 Error in data speed setting combination. Check  current  system  settings
    ERR22 The local site is not participating in the 
    conference room.Check communication status
    ERR23 A specified conference room is not 
    participating in a multi-point 
    conference.Check communication status and execute 
    command.
    ERR24 Multi-point command is either invalid or 
    overlapping.Check communication status and execute 
    command.
    ERR26 VL is not in multi-point conference. Check communication status and execute 
    command.
    ERR32 It cannot be set in the current network. Check communication status and execute 
    command.
    ERR37 The remote terminal cannot be 
    recognized as a NEC model.Check communication status and execute 
    command.
    ERR38 Local loopback cannot be done since it 
    is processing a remote loopback.Execute a command after release of the 
    remote loopback.
    ERR 40 It is in a telephone communication 
    mode.Command to execute is impossible.
    ERR41 Network in use is not an ISDN line. Check current system settings
    ERR42 No incoming call Check communication status and execute 
    command.
    ERR43 Currently originating a call. Check communication status and execute 
    command.
    ERR44 Incoming call Check communication status and execute 
    command.
    ERR45 On line. Check communication status and execute 
    command again. 
    						
    							Page 4-2NDA-24233 Issue 2
    Error Response Table VisuaLink 128/384 Engineering Guide
    Figure 4-1:  Error Response Table (2/2)
    ERR Number Contents Countermeasures
    ERR46 Off line. Check communication status and execute 
    command again.
    ERR47 Currently processing. Try again
    ERR48 Disconnecting. Check communication status and execute 
    command again.
    ERR49 Specified delay time is not in decimal. Check the format of command.
    ERR50 Specified delay time is not in 10 ms 
    step.Check the format of command.
    ERR51 It cannot be executed since a command 
    generator is in execution.Try again
    ERR85 Execution is impossible. Re-start VL unit
    ERR86 File overflow of the command generator  Try again
    ERR87 CODEC processing. Try again
    ERR88 Exchanging capabilities. Try again
    ERR90 Command not currently supported.  Command to execute is impossible. 
    						
    							NDA-24233 Issue 2Page 5-1
    VisuaLink 128/384 Engineering Guide Factors of  Disconnections
    5:  List of Factors for Disconnection in Table
    Location of Factors for Disconnection
    LU: Local User LN: Local Network TN: Transit Network RU: Remote User RN: Remote Network
    Number Message Factors for Disconnection Countermeasure (Example) Location
    # 1 Unassigned 
    numberCall cannot come in since it is 
    currently a unassigned number. Check the remote number. LN/RU
    # 2 No route to 
    specified transit 
    networkSpecified transit network cannot be 
    recognized.Check the remote number. TN/LN
    # 3 No route to 
    destinationNo route to remote site. Check the remote number. LN/RU
    # 6 Cancel 
    unacceptableA channel cannot be accepted in a 
    network.After a while, retry connection. LN
    # 7 Remote is busy Connected channel is used. After a while, retry connection. LN
    #  16 Normal  is busy A restoration of a disconnection of a 
    call is requested.Try again RU
    # 17 User busy It is currently in a communication 
    with others.After a while, make a 
    connection again.RU/RN
    # 18 No user response No response Check status of remote unit. RN
    # 19 User alerting, no 
    answerNo response after a call message is 
    received.Check status of remote unit. RN
    # 21 Call rejected Communication is rejected. Check status of remote unit. RU
    # 22
    Number changedRemote terminal number has been 
    changed.Check remote number, make 
    another connection.LN/RU
    # 26 Non-selected user 
    clearingNo incoming bell After a while, retry. LN
    # 27 Destination out of 
    orderRemote terminal is OFF Check status of remote unit. RU
    # 28 Invalid number 
    format (address 
    incomplete)Invalid format or incomplete 
    number.Check remote number and 
    retry.LN/RU/
    RN
    # 29 Facility rejected Requested facility is not allowed. Check remote number. LN/RU/
    RN
    # 30 Response to 
    STATus ENquiryInquiry for status was received. Check remote number and 
    retry.LU/LN
    # 31 Normal, 
    unspecifiedNormal status was reported. After a while, retry. RN
    # 34 Circuit/channel 
    congestionNo line or channel is available. Check communication status. LN/RN/TN
    # 38 Line failure Network is not functioning normally. After a while, retry. LU/LN/RU
    # 41 Temporary failure Network is temporarily not available. After a while, retry. RN
    # 42 Switching 
    equipment 
    congestionSwitch is busy. After a while, retry.
    # 43 Access information 
    discardedRequested information element 
    cannot be transmitted to a remote.After a while, retry.
    # 44 Requested channel 
    not availableReported line or channel cannot be 
    provided.After a while, retry. LN/RU
    # 47 Resource 
    unavailable, 
    unspecifiedReport status that other network is 
    busy.Contact a retailer or a service 
    center.
    # 49 This service is 
    currently not 
    availableQOS cannot be provided. RU/RN/
    LN 
    						
    							Page 5-2NDA-24233 Issue 2
    Factors of  Disconnections
    Number Message Factors for Disconnection Countermeasure (Example) Location
    # 50 Requested facility 
    not subscribedProcedure for a requested facility is 
    not taken.Contact a retailer or a service 
    center.LN
    # 57 Bearer capability 
    not authorizedUnauthorized transmission 
    capability was requested.Contact a retailer or a service 
    center.LN
    # 58 Bearer capability 
    not presently 
    availableTransmission capability currently 
    not available for use.Contact a retailer or a service 
    center.LN
    # 63 Service or option 
    not availableReport that other services cannot be 
    used.Contact a retailer or a service 
    center.LN
    # 65 Bearer capability 
    not implementedRequested transmission capability 
    is not supported.Contact a retailer or a service 
    center.
    # 66 This service is 
    currently not 
    availableRequested channel class is not 
    supported.Contact a retailer or a service 
    center.RU/RN/
    LN
    # 69 Requested facility 
    not implementedRequested additional service is not 
    supported.Contact a retailer or a service 
    center.
    # 70 A connection could 
    not be madeLimited digital transmission 
    capability among requested 
    transmission capabilities is 
    supported.Contact a retailer or a service 
    center.LU/LN
    # 79 Service or option 
    not implementedReport that a service cannot be 
    provided.After checking a remote 
    number, retry.
    # 81 Invalid call 
    reference valueDifferent dial number from the 
    currently used number is used.After checking a remote 
    number, retry.LN
    # 82 Please dial again Invalid channel number is used. After checking a remote 
    number, retry.LN
    # 83 A connection could 
    not be madeA different number from the interrupt 
    call discriminating number is used.After checking a remote 
    number, retry.LN
    # 84 A connection could 
    not be madeThe interrupt call discriminating 
    number currently in use is used.After checking a remote 
    number, retry.LN
    # 85 A connection could 
    not be madeCall discriminating number is not 
    used.After checking a remote 
    number, retry.RU
    # 86 A connection could 
    not be madeInterrupt call has already been 
    disconnected.After checking a remote 
    number, retry.TN/ LN
    # 88 Incompatible 
    destinationAttribute of a terminal unit does not 
    match.After checking a remote 
    number, retry.LN
    # 91 No available line for 
    useFormat of a transit network is not 
    normal.After checking a remote 
    number, retry.
    # 95 A connection could 
    not be madeReport of other invalid messages.
    # 96 Mandatory 
    information element 
    is missingRequired information element is in 
    short.Contact a retailer or a service 
    center.LU/ LN
    # 97 A connection could 
    not be madeUndefined or not-provided message 
    is received.Contact a retailer or a service 
    center.LU/ LN
    # 98 A connection could 
    not be madeMessage mismatch. Contact a retailer or a service 
    center.LU/ LN
    # 99 A connection could 
    not be madeInformation element is undefined. Contact a retailer or a service 
    center.LU/ LN
    # 100 Invalid information 
    element contentsThe contents of information element 
    is invalid.Contact a retailer or a service 
    center.LU/LN
    # 101 Message not 
    compatible with call 
    stateReceived message and a call status 
    mismatch.After checking a remote 
    number, retry.LU/LN
    # 102 Recovery on timer 
    expiryRestoration due to an expiration of 
    timer.After checking a remote 
    number, retry.LU/LN 
    						
    							NDA-24233 Issue 2Page 5-3
    VisuaLink 128/384 Engineering Guide Factors of  Disconnections
    Number Message Factors for Disconnection Countermeasure (Example) Location
    # 111 Protocol error, 
    unspecifiedReport of other protocol error. After checking a remote 
    number, retry.RN
    # 127 Interworking, 
    unspecifiedInter-work occurrence in a network 
    that cannot display a reason for 
    operation.After checking a remote 
    number, retry.
    # 901 No response from 
    the remote terminalAutomatic Dial timed out Check a remote unit status.
    # 903 Network failure Line (layer 1) failure (Physical 
    connection error).Contact a retailer or a service 
    center.
    # 904 Network failure Line (layer 2) failure (Electric 
    interface error)Contact a retailer or a service 
    center.
    # 905 Network failure or 
    wrong contactTEI error Contact a retailer or a service 
    center.
    # 906 Network failure Layer 3 (Appreciation layer) calling 
    timed outContact a retailer or a service 
    center.
    # 907 Disconnected by 
    initializationNot used
    # 908 Disconnected by 
    initializationNot used Contact a retailer or a service 
    center.
    # 909 Disconnected by 
    initializationNot used Contact a retailer or a service 
    center.
    # 912 Disconnected by 
    initializationMessage inconsistent with the 
    current condition is received.After a while, retry.
    # 913 Disconnected by 
    initializationConnect and disconnect during a re-
    start response waiting.After a while, retry.
    # 914 Network failure Lower layer in failure
    # 915 network failure Lower layer in failure
    # 916 The provisioned 
    communication 
    time expiredCalling condition is NG
    # 917 A connection could 
    not be madeLayer 3 initialization not completed
    # 918 A connection could 
    not be madeLayer 3 initialization missed
    # 919 A connection could 
    not be madeCES pointing error
    # 980 Disconnected VCP (Video chip hang-up) After a while, retry. 
    						
    							Page 5-4NDA-24233 Issue 2
    Factors of  Disconnections
    This page is for your notes. 
    						
    							NDA-24233 Issue 2Page A-1
    VisuaLink 128/384 Engineering Guide Appendix A
    Appendix A:  Pin-out Specification
    Pin-out specifications for all the VL 128/384 connectors.
    SERIAL 1 PORT
    Note:
      The signal direction shown is seen from the VisuaLink 128 (DTE).
    SERIAL 2 PORT
    Note:
      The signal direction shown is seen from the VisuaLink 128 (DTE).
    Headset
    MIC Connection (1 - 3)
    NO Symbol Direction Function
    1 RS OUT Request to Send
    2 CS IN Clear to Send
    3 SD OUT Send Data
    4 GND - Ground
    5 RD IN Receive Data
    6- -
    7 ER OUT Data Terminal Ready
    8 DR IN Data set Ready
    NO Symbol Direction Function
    1 RS OUT Request to Send
    2 CS IN Clear to Send
    3 SD OUT Send Data
    4 GND - Ground
    5 RD IN Receive Data
    6+5V OUT
    7 ER OUT Data Terminal Ready
    8 DR IN Data set Ready
    Name Function
    TIP Input from microphone
    RING Output to ear piece
    SLEEVE Ground
    Name Function Polarity
    TIP Input from microphone +
    RING Output to ear piece -
    SLEEVE Ground
    8 PIN MIN DIN FEMALE
    8 PIN MIN DIN FEMALE
    RING
    TIP
    SLEEVE
    HEADSET JACK
    RING
    TIP
    SLEEVE
         MIC JACK 
    						
    							Page A-2NDA-24233 Issue 2
    Appendix A VisuaLink 128/384 Engineering Guide
    S/T Line (ISDN Connection)
    Note 1:
      The signal direction shown is seen from the VisuaLink 128 (DTE).
    Note 2: 
     Pins 1, 2, 7, and 8 are not used.
    Telephone Connection
    S-Video Socket Input/Output
    PIN # Symbol Function Polarity
    1a
    2b
    3 c Transmit Tip +
    4dReceive Tip +
    5 e Receive Ring -
    6fTransmit Ring -
    7g
    8h
    NO Symbol Function
    1
    2
    3 L2 2W RING PIN
    4 L1 2W TIP PIN
    5
    6
    NO PIN NAME
    A1 AG (Analog GND)
    A2 AG (Analog GND)
    A3 Y Signal IN
    A4 O Signal IN
    B1 AG (Analog GND)
    B2 AG (Analog GND)
    B3 Y Signal OUT
    B4 O Signal OUT
    RJ45 FEMALE
    8 7 6 5 4 3 2 1
    RJ11 FEMALE
    6 5 4 3 2 1
    O
    U
    T
    I
    N B4
    B3
    SOCKET B (Output)
    VIDEO2 B2
    B1
    A3A4
    A1A2
    SOCKET A (Input) 
    						
    							NDA-24233 Issue 2Page B-1
    VisuaLink 128/384 Engineering Guide Appendix B
    Appendix B:  Line Speed Specifications
    X : cannot set
    D:
    can set but video is not transmitting
    : snapshot not available
    X : cannot set1B (64kbps) Line Speed
    Audio AlgorithmsG.711 m-Law PCMG.722 SB-ADPCMG.728 LD-CELPMute
    Audio Byte Rate (kbps)56.048.016.00.0
    MLP OFF6.4 14.4 46.462.4
    MLP 4kbps2.4 10.4 42.458.4
    MLP 6.4kbpsD8.0 40.056.0
    MLP 14.4 kbpsXD32.0 48.0
    MLP 24kbpsXX22.4 38.4
    2B (128kbps) Line Speed
    Audio AlgorithmsG.711 m-Law PCMG.722 SB-ADPCMG.728 LD-CELPMute
    Audio Byte Rate (kbps)56.048.016.00.0
    MLP OFF68.876.8108.8124.8
    MLP 4kbps64.872.4104.8120.8
    MLP 6.4kbps62.470.4102.4118.4
    MLP 14.4 kbpsX62.494.4110.4
    MLP 24kbpsXX84.8100.8 
    						
    							Page B-2NDA-24233 Issue 2