    							NDA-24233 Issue 2Page 3-25
    VisuaLink 128/384 Engineering Guide Console Command List
    MDRD Checking Speed Dial Registration 5-4
    Description: Checks the current registers speed dial number.
    Command Format: MDRD p1
    p1:  #xxx: speed dial number (xxx: speed number)
    Response: Normal Response: p1 p2 p3 p4 p5 
    OK
    p1: #xxx :  speed dial number (xxx: speed number 1-130)
    p2: 0-9 :  dial Number (within 20 digits)
           :  sub address (within 8 digits)
    * :  address/subaddress 
    **  :  Ch1/Ch2 separating code
    p3: B : 64 kbps
    2B : 2x64 kbps
    3B : 192 kbps
    4B : 256 kbps
    5B : 320 kbps
    6B : 384 kbps
    TEL : Telephone
    p4: 64 : Px64 Network
    56 : Px56 Network
    p5: xxx :  Remote Site Name (Shift JIS 8-character)
    Note 1:
      If p1 is omitted, all speed dials are displayed.
    Note 2: 
     If non-registration, only p1 is displayed.
    Note 3: 
     If p3 = TEL, p4 is omitted.
    Response:  ERR01
    ERR05  
    						
    							Page 3-26NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    NBZS Setting Incoming Call Buzzer 5-6
    Note: This command is ineffective when setting incoming mode is set to Automatic.  Utilize this command 
    only in the Manual Answer mode.
    NBZI Checking Incoming Call Buzzer Setting 5-7
    Description: Sets the incoming call buzzer in a communication using BRI ISDN, this 
    sets an incoming call bell to rumble when a request for a incoming call 
    from a remote office is received.  This setting is valid only when the 
    incoming call setting is manual.
    Command Format: NBZS  p1
    p1: ON : ring
    OFF : no ring
    Response: Normal Response:  OK
    Error Response:  ERR01
    ERR05 
    Description: Checks the current incoming call ring indication setting.
    Command Format: NBZI
    Response: Normal Response:  p1 OK
    p1: ON : ring
    OFF :  no ring
    Response:  ERR01
    ERR05  
    						
    							NDA-24233 Issue 2Page 3-27
    VisuaLink 128/384 Engineering Guide Console Command List
    SINC Setting Incoming Call Mode 5-8
    Description: Sets the incoming call mode.  There are three ways to receive an incoming 
    call: manual incoming call mode, automatic incoming call mode, and 
    selective incoming call mode.  In a manual incoming call mode, an 
    operation to receive a call is required.  In an automatic incoming call mode, 
    a communication starts when a request for an incoming call is received.  In 
    a selective incoming call mode, only those calls that are registered are 
    received.  All others are rejected.
    Command Format: SINC p1
    p1: M :  manual incoming call mode
    A :  automatic incoming call mode
    S :  selective incoming call mode
    Note 1:
    When p1 is omitted, the current setting status is displayed in a 
    normal response.
    Note 2:
    When p1 = S, an incoming call from the dial number other than 
    those ISDN numbers registered as speed dial numbers.
    Response: Normal Response: If p1 is set:
    OK
    If p1 is omitted:
    p1 OK
    p1: M :  manual incoming call mode
    A :  automatic incoming call mode
    S :  selective incoming call mode
    Error Response:  ERR01
    ERR05  
    						
    							Page 3-28NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    SRNG Setting/Checking Incoming Call Buzzer at Auto Answer Mode 5-9
    SPID Registering SPID 5-10
    Description:Setting ringing times of incoming call buzzer in auto answer mode or 
    selective answer mode
    Command Format:SRNG [p1]
     
    p1: 0-9 : 0: not ringing
    1-9: ringing times
    Note:
      When p1 is omitted, the current setting is reported.
    Response:Normal Response:
    If p1 is set:  OK
    If p1 is omitted:
    p1 OK
    p1: 0: not ringing
    1-9: ringing times
    Error Response:ERR01
    Description: Setting Service Profile ID (SPID)
    Command Format: SPID  p1 p2
    p1: L11 :  Line1 Channel1
    L12 :  Line1 Channel2
    L21 :  Line2 Channel1
    L22 :  Line2 Channel2
    L31 :  Line3 Channel1
    L32 :  Line3 Channel2
    p2 SPID: 0-9 (up to 20 digits)
    OFF: Delete
    Response: Normal Response:  OK
    Error Response:  ERR01
    Note:
      If VL128, setting L21 ~ L32 in p1 are not valid and will create an error. 
    						
    							NDA-24233 Issue 2Page 3-29
    VisuaLink 128/384 Engineering Guide Console Command List
    RPID Checking SPID 5-11
    Description: Reporting current SPID
    Command Format: RPID  p1 
    p1: L11 :  Line1 Channel1
    L12 :  Line1 Channel2
    L21 :  Line2 Channel1
    L22 :  Line2 Channel2
    L31 :  Line3 Channel1
    L32 :  Line3 Channel2
    Response: Normal Response:  p1 p2 OK
    p1:L11 :  Line1 Channel1
    L12 :  Line1 Channel2
    L21 :  Line2 Channel1
    L22 :  Line2 Channel2
    L31 :  Line3 Channel1
    L32 :  Line3 Channel2
    p2:SPID
    Error Response:  ERR01
    Note:
      If VL128, setting L21 ~ L32 in p1 are not valid and will create an error. 
    						
    							Page 3-30NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.6  Camera Related Registering/Setting Command
    CPPS Registering Camera Preset Position 6-1
    CPNS Registering Talker Name 6-2
    Description: Registers a camera preset position.
    Command Format: CPPS  p1 p2 p3 [p4]
    p1: L1-2 :  Local Camera Number
    R1-2 : Remote Camera Number
    p2: 1-9 :  Preset Number
    p3) ON :  Register
    OFF : Release
    p4: x ... x :  Talker Registration (alphabet 16-character)
    Note 1:
      When p3 is OFF, p4 is omitted.
    Note 2:
      A talker name is deleted in p4 = “ “
    Response: Normal Response: p1 OK
    Response:  ERR01
    ERR10 
    Description: Registers a preset talker name.
    Command Format: CPNS p1 p2 = [p3]
    p1: L1-2 :  Local Camera Number
    p2: 1-9 :  Talker Name Number
    p3: x ... x :  Talker Name Registration (alphabet 16-character)
    Note 1:
    When p2 is OFF, the contents of registration of a talker name 
    number is displayed.
    Note 2:
    A talker name is deleted in p2 = “ “
    Note 3:
    When p1 and p2 are omitted, all the registered contents are 
    displayed.  When a talker name is not registered, No Entry is 
    displayed.
    Response: Normal Response: OK
    Error Response:  ERR01
    ERR10 
    						
    							NDA-24233 Issue 2Page 3-31
    VisuaLink 128/384 Engineering Guide Console Command List
    SCMK Setting Camera Model 6-3
    RCMK Checking Camera Model Setting 6-4
    Description: Sets types of camera which will be controlled.
    Command Format: SCMK  p1
    p1: S : EVI-D30
    C : VC-C1
    Response: Normal Response: OK
    Error Response:  ERR01
    Description: Checks current camera control setting.
    Command Format: RCMK
    Response: Normal Response: p1 OK
    p1: S : EVI-D30
    C : VC-C1
    Error Response:  ERR01  
    						
    							Page 3-32NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.7  Communication Status Reading Command
    RMAC Read Manufacturer Code 7-1
    Description: Acquires manufacturer code of a remote site.
    Command Format: RMAC
    Response: Normal Response: p1 p2 p3 p4 p5 OK
    p1: 00-FF : Manufacturer code  49:  NEC
    Else: other vendor
    p2: 00-FF : Division code    00:  NEC
    Else:  other division of NEC
    p3: 00-FF : Unit code    01:  TC5000EX7/10
    02: MMVC
    03: VL128/384
    10: MCU5000A
    Else: Reserved
    p4: 00-FF : Own Capability code
    D0:  Kanji Display Capability  0:  Off (option)
    1:  On (option)
    D1:  Composite Screen Display Capability 0:  Off
    1: On
    D2:  H281 Camera Control Capability  0:  Off (option)
    1:  On (option)
    p5: 00-FF : Reserved
    Error Response:  ERR01
    ERR07
    ERR42
    ERR46
    ERR47
    ERR85
    ERR87
    D7 D6D5
    D4D3
    D2D1
    D0 
    						
    							NDA-24233 Issue 2Page 3-33
    VisuaLink 128/384 Engineering Guide Console Command List
    RMOD Read Common Mode During Communication 7-2
    Description: Reads negotiated parameter setting.
    Command Format: RMOD
    Response: Normal Response: p1 p2 p3 p4 p5 p6 p7 p8 OK
    p1: 64 : 56/64 kbps
    2x64 : 2x56/2x64 kbps
    192 : 168/192 kbps
    256 : 224/256 kbps
    320 : 280/320 kbps
    384 : 336/384 kbps
    p2: 56 : 56 kbps network
    64  :  64 kbps network
    p3: QCIF/FCIF  :  video format 
    p4: ULW/ SBA/ LDC/ OFF  : audio mode
    p5: 4.0/6.4/14.4/24.0/VMLP/Off  : MLP speed
    p6: On/Off  :  MBE capability
    p7: On/Off  : T120 capability
    p8: 1.2/4.8/9.6/14.4/OFF : LSD speed
    Error Response:  ERR01
    ERR07
    ERR42
    ERR46
    ERR47
    ERR85
    ERR87 
    						
    							Page 3-34NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    R221 Read H.221 Synchronous Status 7-3
    RPNA Read Remote Site Name (at Point-to-Point) 7-4
    Description: This reads a status of the H.221 frame specified in ITU-T 
    Recommendation
    Command Format: R221
    Response: Normal Response:  p1 OK
    p1: AI :  frame synchronization established
    p2: DI :  frame not in synchronization
    Error Response:  ERR01
    ERR07
    ERR42
    ERR46
    ERR47
    ERR85
    ERR87 
    Description: This reads the remote site name in Point-to-Point (P-P) connection.
    Command Format: RPNA
    Response: Normal Response: p1 OK
    p1: xx ... xx : alphabet location name (within 16 characters) 
    Error Response:ERR01  
    						