NEC Visualink 128/384 Engineering Guide
Have a look at the manual NEC Visualink 128/384 Engineering Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
NDA-24233 Issue 2Page 3-25 VisuaLink 128/384 Engineering Guide Console Command List MDRD Checking Speed Dial Registration 5-4 Description: Checks the current registers speed dial number. Command Format: MDRD p1 p1: #xxx: speed dial number (xxx: speed number) Response: Normal Response: p1 p2 p3 p4 p5 OK p1: #xxx : speed dial number (xxx: speed number 1-130) p2: 0-9 : dial Number (within 20 digits) : sub address (within 8 digits) * : address/subaddress ** : Ch1/Ch2 separating code p3: B : 64 kbps 2B : 2x64 kbps 3B : 192 kbps 4B : 256 kbps 5B : 320 kbps 6B : 384 kbps TEL : Telephone p4: 64 : Px64 Network 56 : Px56 Network p5: xxx : Remote Site Name (Shift JIS 8-character) Note 1: If p1 is omitted, all speed dials are displayed. Note 2: If non-registration, only p1 is displayed. Note 3: If p3 = TEL, p4 is omitted. Response: ERR01 ERR05
![](/img/blank.gif)
Page 3-26NDA-24233 Issue 2 Console Command List VisuaLink 128/384 Engineering Guide NBZS Setting Incoming Call Buzzer 5-6 Note: This command is ineffective when setting incoming mode is set to Automatic. Utilize this command only in the Manual Answer mode. NBZI Checking Incoming Call Buzzer Setting 5-7 Description: Sets the incoming call buzzer in a communication using BRI ISDN, this sets an incoming call bell to rumble when a request for a incoming call from a remote office is received. This setting is valid only when the incoming call setting is manual. Command Format: NBZS p1 p1: ON : ring OFF : no ring Response: Normal Response: OK Error Response: ERR01 ERR05 Description: Checks the current incoming call ring indication setting. Command Format: NBZI Response: Normal Response: p1 OK p1: ON : ring OFF : no ring Response: ERR01 ERR05
![](/img/blank.gif)
NDA-24233 Issue 2Page 3-27 VisuaLink 128/384 Engineering Guide Console Command List SINC Setting Incoming Call Mode 5-8 Description: Sets the incoming call mode. There are three ways to receive an incoming call: manual incoming call mode, automatic incoming call mode, and selective incoming call mode. In a manual incoming call mode, an operation to receive a call is required. In an automatic incoming call mode, a communication starts when a request for an incoming call is received. In a selective incoming call mode, only those calls that are registered are received. All others are rejected. Command Format: SINC p1 p1: M : manual incoming call mode A : automatic incoming call mode S : selective incoming call mode Note 1: When p1 is omitted, the current setting status is displayed in a normal response. Note 2: When p1 = S, an incoming call from the dial number other than those ISDN numbers registered as speed dial numbers. Response: Normal Response: If p1 is set: OK If p1 is omitted: p1 OK p1: M : manual incoming call mode A : automatic incoming call mode S : selective incoming call mode Error Response: ERR01 ERR05
![](/img/blank.gif)
Page 3-28NDA-24233 Issue 2 Console Command List VisuaLink 128/384 Engineering Guide SRNG Setting/Checking Incoming Call Buzzer at Auto Answer Mode 5-9 SPID Registering SPID 5-10 Description:Setting ringing times of incoming call buzzer in auto answer mode or selective answer mode Command Format:SRNG [p1] p1: 0-9 : 0: not ringing 1-9: ringing times Note: When p1 is omitted, the current setting is reported. Response:Normal Response: If p1 is set: OK If p1 is omitted: p1 OK p1: 0: not ringing 1-9: ringing times Error Response:ERR01 Description: Setting Service Profile ID (SPID) Command Format: SPID p1 p2 p1: L11 : Line1 Channel1 L12 : Line1 Channel2 L21 : Line2 Channel1 L22 : Line2 Channel2 L31 : Line3 Channel1 L32 : Line3 Channel2 p2 SPID: 0-9 (up to 20 digits) OFF: Delete Response: Normal Response: OK Error Response: ERR01 Note: If VL128, setting L21 ~ L32 in p1 are not valid and will create an error.
![](/img/blank.gif)
NDA-24233 Issue 2Page 3-29 VisuaLink 128/384 Engineering Guide Console Command List RPID Checking SPID 5-11 Description: Reporting current SPID Command Format: RPID p1 p1: L11 : Line1 Channel1 L12 : Line1 Channel2 L21 : Line2 Channel1 L22 : Line2 Channel2 L31 : Line3 Channel1 L32 : Line3 Channel2 Response: Normal Response: p1 p2 OK p1:L11 : Line1 Channel1 L12 : Line1 Channel2 L21 : Line2 Channel1 L22 : Line2 Channel2 L31 : Line3 Channel1 L32 : Line3 Channel2 p2:SPID Error Response: ERR01 Note: If VL128, setting L21 ~ L32 in p1 are not valid and will create an error.
![](/img/blank.gif)
Page 3-30NDA-24233 Issue 2 Console Command List VisuaLink 128/384 Engineering Guide 3.6 Camera Related Registering/Setting Command CPPS Registering Camera Preset Position 6-1 CPNS Registering Talker Name 6-2 Description: Registers a camera preset position. Command Format: CPPS p1 p2 p3 [p4] p1: L1-2 : Local Camera Number R1-2 : Remote Camera Number p2: 1-9 : Preset Number p3) ON : Register OFF : Release p4: x ... x : Talker Registration (alphabet 16-character) Note 1: When p3 is OFF, p4 is omitted. Note 2: A talker name is deleted in p4 = “ “ Response: Normal Response: p1 OK Response: ERR01 ERR10 Description: Registers a preset talker name. Command Format: CPNS p1 p2 = [p3] p1: L1-2 : Local Camera Number p2: 1-9 : Talker Name Number p3: x ... x : Talker Name Registration (alphabet 16-character) Note 1: When p2 is OFF, the contents of registration of a talker name number is displayed. Note 2: A talker name is deleted in p2 = “ “ Note 3: When p1 and p2 are omitted, all the registered contents are displayed. When a talker name is not registered, No Entry is displayed. Response: Normal Response: OK Error Response: ERR01 ERR10
![](/img/blank.gif)
NDA-24233 Issue 2Page 3-31 VisuaLink 128/384 Engineering Guide Console Command List SCMK Setting Camera Model 6-3 RCMK Checking Camera Model Setting 6-4 Description: Sets types of camera which will be controlled. Command Format: SCMK p1 p1: S : EVI-D30 C : VC-C1 Response: Normal Response: OK Error Response: ERR01 Description: Checks current camera control setting. Command Format: RCMK Response: Normal Response: p1 OK p1: S : EVI-D30 C : VC-C1 Error Response: ERR01
![](/img/blank.gif)
Page 3-32NDA-24233 Issue 2 Console Command List VisuaLink 128/384 Engineering Guide 3.7 Communication Status Reading Command RMAC Read Manufacturer Code 7-1 Description: Acquires manufacturer code of a remote site. Command Format: RMAC Response: Normal Response: p1 p2 p3 p4 p5 OK p1: 00-FF : Manufacturer code 49: NEC Else: other vendor p2: 00-FF : Division code 00: NEC Else: other division of NEC p3: 00-FF : Unit code 01: TC5000EX7/10 02: MMVC 03: VL128/384 10: MCU5000A Else: Reserved p4: 00-FF : Own Capability code D0: Kanji Display Capability 0: Off (option) 1: On (option) D1: Composite Screen Display Capability 0: Off 1: On D2: H281 Camera Control Capability 0: Off (option) 1: On (option) p5: 00-FF : Reserved Error Response: ERR01 ERR07 ERR42 ERR46 ERR47 ERR85 ERR87 D7 D6D5 D4D3 D2D1 D0
![](/img/blank.gif)
NDA-24233 Issue 2Page 3-33 VisuaLink 128/384 Engineering Guide Console Command List RMOD Read Common Mode During Communication 7-2 Description: Reads negotiated parameter setting. Command Format: RMOD Response: Normal Response: p1 p2 p3 p4 p5 p6 p7 p8 OK p1: 64 : 56/64 kbps 2x64 : 2x56/2x64 kbps 192 : 168/192 kbps 256 : 224/256 kbps 320 : 280/320 kbps 384 : 336/384 kbps p2: 56 : 56 kbps network 64 : 64 kbps network p3: QCIF/FCIF : video format p4: ULW/ SBA/ LDC/ OFF : audio mode p5: 4.0/6.4/14.4/24.0/VMLP/Off : MLP speed p6: On/Off : MBE capability p7: On/Off : T120 capability p8: 1.2/4.8/9.6/14.4/OFF : LSD speed Error Response: ERR01 ERR07 ERR42 ERR46 ERR47 ERR85 ERR87
![](/img/blank.gif)
Page 3-34NDA-24233 Issue 2 Console Command List VisuaLink 128/384 Engineering Guide R221 Read H.221 Synchronous Status 7-3 RPNA Read Remote Site Name (at Point-to-Point) 7-4 Description: This reads a status of the H.221 frame specified in ITU-T Recommendation Command Format: R221 Response: Normal Response: p1 OK p1: AI : frame synchronization established p2: DI : frame not in synchronization Error Response: ERR01 ERR07 ERR42 ERR46 ERR47 ERR85 ERR87 Description: This reads the remote site name in Point-to-Point (P-P) connection. Command Format: RPNA Response: Normal Response: p1 OK p1: xx ... xx : alphabet location name (within 16 characters) Error Response:ERR01