    							NDA-24233 Issue 2Page 3-65
    VisuaLink 128/384 Engineering Guide Console Command List
    3.25  Alarm Status Report Command
    RALM Alarm Status Change Report (1 of 2) 25-1
    Description: Reports the VisuaLink alarm status.  This is reported when alarm and loopback 
    status is changed.
    Command Format: RALM p1 p2 p3 p4 p5 p6 
    p1: 00-FF :  CPU/ VIDEO alarm
    p2: 00-FF :  LINE alarm
    p3: 00-FF :  H221 alarm
    p4: 00-FF :  Bonding alarm
    p5: 00-FF :  TEST status
    p6: 00-FF :  TEST status 2
    p1: CPU/ VIDEO alarm
    D0 :  CPU alarm   0: normal  1: abnormal
    D1 :  FAN alarm   0: normal  1: abnormal
    D2-3 :  Unused   0: fixed
    D4 :  VIDEO alarm  0: normal  1: input cut
    D5-7 :  Unused   0 fixed
    p2: LINE alarm
    D0-3 :  Unused   0 fixed
    D4 :  SYNC alarm  0: normal  1: abnormal
    D5 : SYNC alarm 0: normal 1: abnormal
    D6 : SYNC alarm 0: normal 1: abnormal
    D7 :  Unused   0 fixed
    p3: H221 alarm
    D0 :  REC alarm   0: normal  1: abnormal
    D1 :  CRC alarm   0: normal  1: abnormal
    D2-7 :  Unused   0 fixed
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0 
    						
    							Page 3-66NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    RALM Alarm Status Change Report (2 of 2) 25-1
    p4: Bonding alarm
    D0 :  Bonding frame loss   0: normal  1: abnormal
    D1 :  Bonding speed negotiation fail 0: normal  1: abnormal
    D2 : Bonding type negotiation fail 0: normal 1: abnormal
    D3 :  Dial number negotiation fail   0: normal 1: abnormal
    D4 :  Additional channel connecting error 0: normal  1: abnormal
    D5-7 :  Unused   0: fixed
    p5: TEST status
    D0-3 :  Unused  0 fixed
    D4-5 :  Local Loopback   00:  Off
    01: Video
    10: Audio
    11: LINE
    D6-7 :  Unused   0  fixed
    P6: TEST status 2
    D0-1 :  Video mute   0: normal  1: abnormal
    D2-3 :  Unused 0: fixed
    D4 : Audio mute 0: normal 1: abnormal
    D5 :  Line 1 loopback   0: OFF 1: ON
    D6 :  Line 2 loopback 0: OFF  1: ON
    D7 :  Line 3 loopback 0: OFF  1: ON
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0
    D7 D6D5
    D4D3
    D2D1
    D0 
    						
    							NDA-24233 Issue 2Page 3-67
    VisuaLink 128/384 Engineering Guide Console Command List
    3.26  Video Status Report Command
    RVSR Incoming Video Synchronous Status Report 26-1
    Description: VisuaLink monitors a synchronization status of a received video, and a 
    report is made when a received video synchronization status changes.
    Command Format: RVSR p1 
    p1: AI :  synchronization established
    DI :  out of synchronization 
    						
    							Page 3-68NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.27  Participating Status Report Command
    ICST Participating Conference Status Report 27-1
    Description: Reports participating conference status.
    Command Format: ICST p1 p2 
    p1: PP  :  point – point connection 
       MP  :  multipoint connection 
    p2: H243  :  multi-point conference based on ITU-T H243 
    MLP  :  NEC specific multi-point conference 
    Note:
      When p1 = PP, p2 is omitted. 
    						
    							NDA-24233 Issue 2Page 3-69
    VisuaLink 128/384 Engineering Guide Console Command List
    3.28  ISDN Report Command
    NALT Display During Calling 28-1
    NINC Incoming Call Report 28-2
    NONL On-line Report 28-3
    Description: Call report status an origination point.  This means calling to remote site.
    Command Format: NALT
    Description: Incoming call report.  This is a report to indicate a request for connection 
    from a remote unit has been received.
    Command Format: NINC p1 p2 p3
    p1: M :  manual incoming call mode
    A :  automatic incoming call mode
    S :  selective incoming call mode 
    p2: Remote site number
    p3: B : 64 kbps
    TEL :  TEL
    Description: This is an on-line report.  This report to shows the VisuaLink is in 
    communications.
    Command Format: NONL p1
    p1: B : 64 kbps 
       2B  :  2x64 kbps 
    3B : 192 kbps
    4B : 256 kbps
    5B : 320 kbps
    6B : 384 kbps
    TEL :  TEL  
    						
    							Page 3-70NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    NDCI Disconnection Report 28-4
    Description: Reports disconnecting the ISDN line.  This is a report to show that 
    communication is disconnected.  Section 9 describes the disconnection 
    reason.
    Command Format: NDCI p1 p2 p3 p4 p5 p6 p7 p8
    p1: hh:mm:ss :  communication time (hour: minute: seconds)
    p2: xxxxx  :  communication fee (0-99, 999)
    p3: #000-#999  :  Reason for CH1 disconnection
    p4: #000-#999  :  Reason for CH2 disconnection
    p5: #000-#999  :  Reason for CH3 disconnection
    p6: #000-#999  :  Reason for CH4 disconnection
    p7: #000-#999  :  Reason for CH5 disconnection
    p8: #000-#999  :  Reason for CH6 disconnection
    Note:
      If VL128, p5 ~ p8 do not apply. 
    						
    							NDA-24233 Issue 2Page 3-71
    VisuaLink 128/384 Engineering Guide Console Command List
    3.29  Camera Control Report Command
    CAMI Camera Status Report 29-1
    CPNI Talker Name Display Report 29-2
    Description: This is a status report on the remote camera condition.  (When remote 
    camera control is used)
    Command Format: CAMI p1
    p1: 0 :  not connected 
       1 :  fixed camera
    3 :  preset camera
    Description: This is a report on a conference room number of a remote camera and a 
    preset talker name.
    Command Format: CPNI p1 p2
    p1: 0-99  :  conference room number 
    p2: xxxxx  :  preset talker name (alphabet 16-character) 
    						
    							Page 3-72NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.30  Option Control Report Command
    STEI SnapShot Transmission Ending Report 30-1
    RFVR SnapShot Reception Report 30-2
    Description: This is a report notifying a snapshot transmission is completed.
    Command Format: STEI p1
    p1: OK :  normal ending 
       NG :  failure
    Description: This is a report when receiving a snapshot picture.
    Command Format: RFVR p1
    p1: 01: receiving
       00:  receiving is completed 
    						
    							NDA-24233 Issue 2Page 3-73
    VisuaLink 128/384 Engineering Guide Console Command List
    3.31  Other Report Command
    CGSI Automatic Activation File Starting Report 31-1
    CGEI Automatic Activating File Ending Report 31-2
    Description: This is a report to show the start of auto executed file.
    Command Format: CGSI p1
    p1: 0-7 : number of file for auto executed file
    Description: This is a report to show the completion of auto executed file.
    Command Format: CGEI p1 p2
    p1: 0-7  :  number of file for auto executed file     
    p2: xxxxx : ending result
    xxxx :  OK  :  normal ending
    EMPTY : no data
    EX ERR  :  access error
    CMD ERR  :  command execution error 
    						
    							Page 3-74NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.32  Multi-Point  Related Report Command
    IMPS Multi-point Conference Operation Status Report 32-1
    IMMD Multi-point Conference Mode Status Report 32-2
    COPI Acquisition of Right to Operate Report 32-3
    Description: This is a report on the status of multi-point conference.
    Command Format: IMPS  p1 p2 p3 p4 p5 p6
    p1: 1-255  :  local site conference room number
    p2: 0/1  :  status of acquisition of a right to operate in a local site 
    1: acquired 0: released 
    p3: 1-255  :  location number of a video transmitting
    p4: 0/1  :  local site transmitting status 0: OFF 1: ON 
    p5: 1-255  :  a number of multi-point conference participants
    p6: 0/1  :  screen composite capability 0: none 1: yes
    Description: This is a report on the status of multi-point conference mode.
    Command Format: IMMD  p1 
    p1: 1: audio switch
    2:  local site transmission
    3: operator
    4: reception selection
    5:  a status of multiple address transmission by operator
    Description: This is a report on the acquisition or release of right of chairman mode.
    Command Format: COPI p1 p2 
    p1: 1-255 : conference room number
    p2: ON/OFF  :  acquire/ release 
    						