    							NDA-24233 Issue 2Page 3-75
    VisuaLink 128/384 Engineering Guide Console Command List
    CSPI Multiple Address Transmission Report 32-4
    CRPI Specific Picture Reception Report 32-5
    CVCI Talker Detection Control Report 32-6
    Description: This is to report the completion of a simulcast transmission.
    Command Format: CSPI p1 
    p1: 0-255, * :  conference room number
    Note 1:
    When p1 = 0, it indicates a release of a multiple address 
    transmission in H.243 multi-point conference.
    Note 2:
    When p1 = *, it indicates a screen composition. 
    Description: This report on a completion of specific video reception process.
    Command Format: CRPI p1 p2 p3
    p1: 1-255  :  reception side conference room number
    p2: 1-255/*  :  transmission side conference room number
    p3: ON/OFF  :  reception selection setting/ release
    Note 1:
    In a NEC specific multi-point conference, 1-14 only can be 
    specified. 
    Note 2:
    In p2, * indicates a screen composition. 
    Description: This report the execution of an audio switch process.
    Command Format: CVCI p1 p2 
    p1: 0-255  :  audio switch control conference room number
    p2: ON/OFF  :  audio switch execution/ release
    Note: 
     When p1 = 0, it indicates a general setting.  
    						
    							Page 3-76NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    CSSC SnapShot Transmission Permit Report 32-7
    CMPI Multiple Address Originator Monitor Video Switch Report 32-8
    CJNI Terminal Connection Report 32-9
    Description: This report is a request to transmit a snapshot.
    Command Format: CSSC p1 
    p1: 1-255 :  conference room number where a still-picture 
    transmission request was made.
    Description: This report a conference room number for a monitor of a simulcast 
    transmission originator.
    Command Format: CMPI p1 p2 
    p1: 1-255/* :  conference room number of simulcast 
    transmission originator
    p2: 1=255/*:  conference room number to be monitored by 
    simulcast transmission originator
    Note:
      In p1 and p2, * indicates screen composition. 
    Description: This is a terminal connection report.
    Command Format: CJNI p1
     
    p1: 1-255 :  conference room number of participating terminal 
    						
    							NDA-24233 Issue 2Page 3-77
    VisuaLink 128/384 Engineering Guide Console Command List
    CSTI Conference Status Report 32-10
    Description: This is to report the multi-point conference status.  This is reported only in 
    a NEC specific multi-point conference.
    Command Format: CSTI p1 p2 p3 p4 p5 p6 ............ p18
    p1: 1-14  :  local site conference number
    p2: 0000-FFFF  :  conference participating status 1: participate 
    0: not participate
    p3: 0000-FFFF  :  terminal connection status 1: connect 
    0: not connected
    p4: 0000-FFFF  :  audio switch status 1: switch 0: not switch
    p5: 0000 : fixed
    p6: 0000 : fixed
    p7: 1-14  :  operator conference room number 
    00: no operator
    p8: 1-14 :  conference room number of the originator of 
    multiple address transmission
    p9: 1-14  :  conference room number of a location 
    receiving multiple address transmission.
    p10: 1-14  :  conference room number of the originator of 
    a transmission at a specified video reception.  
    It is not a specific video reception if it is 00.
    p11: 0 : fixed
    p12: 0 : fixed
    p13: 0 : fixed
    p14: 0 : fixed
    p15: 0 : fixed
    p16: 0 : fixed
    p17: 1111 : fixed
    p18: 0-1  :  local site in transmission  0: not transmitting 
    1: transmitting
    Note 1:
    When p1 = 0, a local office withdraw from a multi-point 
    conference.
    Note 2:
    Bit assignment of 0000-FFFF is as follows.
    XX
    14131211109876543 21
    Master Only
    Slave                                        Master 
    						
    							Page 3-78NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.33  Multi-Screen Related Report Command
    XMII Composite Screen Setting Report 33-1
    XMCI Standard Display Screen Setting Report 33-2
    Description: Reports a composite screen setting.
    Command Format: XMII p1 p2/p3 p4=p5: p6
    p1: Composite Screen Status
    D7-D5  :  0 fixed
    D4-D3  :  re-lineup 00: none 10: in the order of terminal number
    D2  :  speaker display 0: none 1: yes
    D1-D0  :  0 fixed
    p2 : Number of Composite Screen : 04: 4 screens 09: 9 screens 
    16: 16 screens
    p3 : Composite Pattern : A fixed
    p4 : Composite Screen Position : 01~16 
    p5 : MCU number : 00-FF
    p6 : Terminal number : 00-FF 
    Example:
    XMII
    00 04/A 01=01:01 02=01:02 03=01:03
    Note:
      p4=p5:p6 is reported only when received from a MCU.
    Description: Reports a standard display screen setting.
    Command Format: XMCI p1
     
    p1: S :  single screen 
    M  :  multiple composite screen
    D7 D6D5
    D4D3
    D2D1
    D0 
    						
    							NDA-24233 Issue 2Page 3-79
    VisuaLink 128/384 Engineering Guide Console Command List
    XSCI Response to Composite Screen Setting Request 33-3
    Description: This is a response report of composite screen setting/acquisition request.
    Command Format: XSCI  p1 
    p1: OK : normal 
    ERRxx :  NG 
    						
    							Page 3-80NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.34  Microphone Command
    PPNI Voice Activate Microphone Report 34-1
    Description: Report microphone that inputs the voice
    Command Format: PPNI p1
    p1: 1 to 3 
    						
    							NDA-24233 Issue 2Page 3-81
    VisuaLink 128/384 Engineering Guide Console Command List
    3.35  System Error Command
    ERRI System Error Report 35-1
    Description: Report system error
    Command Format: ERRI p1
    p1: [S_RAM] BACKUP ERROR: SRAM error
    [SYSTEM] BACKUP ERROR: System parameter error
    [M_DIAL] BACKUP ERROR: Speed dial information error
    [S_NAME] BACKUP ERROR: Preset talker name error
    [C_PRIS] BACKUP ERROR: VC-C1 preset error
    [CG FILE] BACKUP ERROR: CG file error
    [S_PRIS BACKUP ERROR: EVI-D30 preset error
    [R_DIAL] BACKUP ERROR: Redial information error
    [AEC_7K] INITIAL ERROR: Echo canceller initialize failure 
    						
    							Page 3-82NDA-24233 Issue 2
    Console Command List VisuaLink 128/384 Engineering Guide
    3.36  On-Screen Command
    SOSD Setting On-Screen Display 36-1
    Description: Sets the On-Screen displays for the VisuaLink
    Command Format: SOSD p1
    p1: ON: Activates the On-Screen Message
    OFF: Deactivates the On-Screen Message
    Response: Normal Response:   OK
    Error Response:  ERR01 
    ERR07
    ERR85
    ERR87 
    						
    							NDA-24233 Issue 2Page 3-83
    VisuaLink 128/384 Engineering Guide Console Command List
    3.37  Current Power OFF Condition
    CSTB Current Power OFF Condition 37-1
    Description: Set and read the current Power OFF Condition.  The CODEC outputs black video 
    when no user intervention has been acted on for a period of time.
    Command Format: CSTB p1
    p1: 00 - 10: up to 10 minutes with one minute intervals
    CSTB
    Response: Normal Response:   OK