NDA-24248 Revision 1.0Page 11-5 VisuaLink 128/384 Director Guide Chapter 11 11.1.3 Data Setting Use this function to set the data communication speed. Select Maintenance | Environment to display Environment dialog, then Data tab. Figure 11-5: Data Setting A. MLP Speed You can set the MLP speed that is used for the data conference, NEC proprietary conference, and NEC proprietary camera control. Default value is 4.0 kbps. B. LSD Speed You can set the LSD speed that is used for the data transfer, and ITU-T standard camera control. Default value is 1.2 kbps. A B

Page 11-6NDA-24248 Revision 1.0 Chapter 11 VisuaLink 128/384 Director Guide 11.1.4 User 1 Setting Use this function to set the user information and call receiving. Select Maintenance | Environment to display Environment dialog, then User 1 tab. Figure 11-6: User 1 Setting A. Phone Number You can enter your own phone number (dial/sub address). Only numerical texts are available for the phone number entry. Maximum characters are 20 for the phone number and 8 for the sub address. No registered data appears for the default. B. Location You can enter own location. Data entry is not available when you activate Delete Own Information . No registered data appears for the default. C. Delete Own Information Check this checkbox when you wish to delete your registered phone number and location. D. Reception Mode Use this section to specify the call receiving mode. Default value is Auto. E. Call Notification Check this checkbox to activate a buzzer when you receive a call. Default is unchecked. F. Number of Rings Set the number of rings that are required before call is answered. A BC D E F

NDA-24248 Revision 1.0Page 11-7 VisuaLink 128/384 Director Guide Chapter 11 Note: You cannot set Phone Number , Receiving Mode , and Call Notification when the basic proprietary line. 11.1.5 User 2 Setting Use this function to set the start-up information setting for VisuaLink Director. Select Maintenance | Environment to display Environment dialog, then User 2 tab. Figure 11-7: User 2 Setting A. Display Password dialog Check this checkbox to display Confirm Password dialog for each VisuaLink Director start-up operation. Default is unchecked (hide Confirm Password dialog). B. Display Run dialog Check this checkbox to display Run dialog for each VisuaLink Director start-up operation. Default is checked (display Run dialog). C. Video Capture Application Check this checkbox to start the video capture application from a default path. Default is unchecked (deactivate video capture application). D. Video Capture Application Path To change a path, you can manually type a path of the video capture application. E. Data Conference Application Check this checkbox to start the data conference application from a default path. Default is unchecked (deactivate data conference application). F. Data Conference Application Path To change a path, you can manually type a path of the data conference application. A B C D E FG H

Page 11-8NDA-24248 Revision 1.0 Chapter 11 VisuaLink 128/384 Director Guide G. [Reference…] button To change a path, you can also click this button to display Select Path dialog that allows you to select a path visually. H. PC COM Port for VisuaLink buttons Select the correct COM port that is connected to the VisuaLink. 11.1.6 Line Setting Use this function to set the start-up information setting for VisuaLink Director. Select Maintenance | Environment to display Environment dialog, then Line tab. Figure 11-8: Line Setting A. Network Use this field to select a network type for the conference capability of call receiving. Default is Px64. B. Communication Speed Use this field to select a communication speed for the conference capability of call receiving. Default is 2B. C. Line Type Use this field to select a line type for the conference capability of call receiving. Default is National ISDN (NI1). A B C

NDA-24248 Revision 1.0Page 11-9 VisuaLink 128/384 Director Guide Chapter 11 11.1.7 Serial Setting Use this function to set the Serial Port 1. Select Maintenance | Environment to display Environment dialog, then Serial tab. Figure 11-9: Serial Setting A. Serial Port 1 Use this field to select a hardware that you wish to connect to VisuaLink. Default is Camera (EVI-D30). B. Camera Control Use this field to select a remote camera control method. To activate this item, you need to select Camera (EVI-D30) or Camera (VC-C1) on Serial Port 1 field. Default is Auto. AB

Page 11-10NDA-24248 Revision 1.0 Chapter 11 VisuaLink 128/384 Director Guide 11.2 Changing Your PasswordFollow the operation below to change the registered password. Operation Select Maintenance | Change Password from the Main Menu . Figure 11-10: Change Password Menu Change Password dialog appears. Figure 11-11: Change Password A. Current Password Type the currently registered password. “*” will appear as you type. B. New Password Type new password that you wish to register. You can enter up to 16 characters. “*” will appear as you type. Spacing is not available. C. Cancel button Click this button to close Change Password dialog and quit this function. Type both Current Password and New Password , then click OK . Password Confirmation dialog appears when current password and registered password match. If you enter an incorrect password, you are prompted to reenter the password correctly. Type the new password that you registered, then click OK . When the new and registered password are matched, system updates the password and closes both A B C

NDA-24248 Revision 1.0Page 11-11 VisuaLink 128/384 Director Guide Chapter 11 Password Confirmation dialog and Change Password . If entered password is incorrect, you need to reenter the correct password. Click Cancel to close Password Confirmation dialog, then quit this function.

Page 11-12NDA-24248 Revision 1.0 Chapter 11 VisuaLink 128/384 Director Guide 11.3 Starting a Loopback TestYou can test the system operation by executing the remote/local loopback test. Follow the operation below to start the loopback test. Operation Select Maintenance | Loopback Test from the Main Menu . Figure 11-12: Maintenance Menu Loopback Test dialog appears. Select a test method that you wish to manipulate. Figure 11-13: Loopback Test A. Local Loopback Test You can select the test items. You cannot start this test when the conference is in process. B. Remote Loopback Test You can start the Remote Loopback Test. You cannot start this test when the conference is not in process. C. Test Window Displays the progress of the loopback test being performed. D. Release button Press the Release button to cancel the loopback test. A CD EB

NDA-24248 Revision 1.0Page 11-13 VisuaLink 128/384 Director Guide Chapter 11 E. Finish button Click Finish . If you click this button during the testing, the system aborts the test and closes Loopback Test dialog.

Page 11-14NDA-24248 Revision 1.0 Chapter 11 VisuaLink 128/384 Director Guide 11.4 Viewing a Communication HistoryYou can confirm the previous communication history. Follow the operation below to view the history. Operation Select Maintenance | Communication History View from the Main menu . Figure 11-14: Maintenance Menu