NEC Neax2000 Ivs Small Platform System Manual
Here you can view all the pages of manual NEC Neax2000 Ivs Small Platform System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 61
ND-46551 (E) CHAPTER 3 Page 49 Revision 2.0 NAP-200-003 Sheet 19/21 Installation of Main Equipment (2) Connect the RACK PARTS to each other. Note :This installation procedure is required when the system is 3 modules (PIM + MDFM + BATTM). Figure 003-17 Connection of RACK PARTS RACK PARTS REAR RACK PARTS BASE
Page 62
CHAPTER 3 ND-46551 (E) Pag e 5 0 Revision 2.0 NAP-200-003 Sheet 20/21 Installation of Main Equipment (3) Connect the PIM to the RACK PARTS using the 4 screws provided with the RACK PARTS. Note :This installation procedure is required when the system is 3 modules (PIM + MDFM + BATTM). Figure 003-18 Connection of the PIM and the RACK PARTS REAR PIM Note BASE Note :The BATTM and the MDFM can be installed in the same manner as the PIM.
Page 64
CHAPTER 3 ND-46551 (E) Pag e 5 2 Revision 2.0 NAP-200-004 Sheet 1/5 Connection of Battery 1. BATTERY CONNECTION CAUTION 1:24V batteries must be used in this system. CAUTION 2:If battery terminals (+, –) contact with the module under connecting the battery cable to the PZ- PW86 card, the PZ-PW86 card or the BWB may be broken. Therefore, the installer must per- form work in accordance with the following steps when mounting or removing the batteries. • When mounting batteries: (1) Connect the battery cable...
Page 65
ND-46551 (E) CHAPTER 3 Page 53 Revision 2.0 NAP-200-004 Sheet 2/5 Connection of Battery CAUTION 3:Battery Replacement Table and Battery Warnings The label, which shows battery replacement table and battery warnings, is attached to the re- verse side of Front Cover for PIM and BATTM. During the battery installation process, always observe the warning statements. When replacing batteries, adhere to the battery replacement table to increase battery life and to insure safe op- eration. 25° C ~ 30° C 2.0 ~...
Page 66
CHAPTER 3 ND-46551 (E) Pag e 5 4 Revision 2.0 NAP-200-004 Sheet 3/5 Connection of Battery 1.1 Internal Battery Connection (1) Mount the battery unit (24 V DC, 3.4 AH) into the PIM. Figure 004-1 Internal Battery Mounting FRONT 67mmDIMENSION OF BATTERY BATTERY UNIT (24V DC, 3.4AH) (LOCALLY PROVIDED) (2.6 inch) 134mm (5.3 inch) 60mm (2.4 inch) PIM BASE
Page 70
CHAPTER 3 ND-46551 (E) Pag e 5 8 Revision 2.0 NAP-200-005 Sheet 2/5 Cable Running to the MDF 2. INSTALLATION OF EXTERNAL MDF • Secure the external MDF onto the floor or mount the MDF onto the wall. • Mount the required MDF components. • If required, install the cable ducts for the cables to be laid between the MDF and the Main Equipment. In this case, confirm the locations of the cable holes for the Main Equipment. See Figure 005-2. Figure 005-2 Cable Hole Location FRONT 430 mm (16.9 inch) RACK PARTS...